Carrier GH5S Single-Stage Heat Pump

1-1/2 To 5 Tons

Brand: Carrier

Product Type: Single-Stage Heat Pump

Product Overview

This unit is designed utilizing Carrier's non-ozone depleting Puron® refrigerant. Heat pumps with Puron® refrigerant provide a collection of features unmatched by any other family of equipment.

Note: Ratings contained in this document are subject to change at any time. Always refer to the AHRI directory (www.ahridirectory.org) for the most up-to-date ratings information.

Industry Leading Features / Benefits

Efficiency

Sound

Comfort

Reliability

Durability

Applications

Model Number Nomenclature & Ordering

Model Number Nomenclature

The model number is structured to indicate various features and specifications. Key components include:

Catalog Ordering Numbers

SizeModel Number
18GH5SAN41800A
24GH5SAN42400A
30GH5SAN43000A
36GH5SAN43600A
42GH5SAN44200A
48GH5SAN44800A
60GH5SAN46000A

Standard Features

Feature18243036424860
Puron RefrigerantXXXXXXX
Scroll CompressorXXXXXXX
Field Installed Filter DrierXXXXXXX
Front Seating Service ValvesXXXXXXX
Internal Pressure Relief ValveXXXXXXX
Internal Thermal OverloadXXXXXXX
Long Line capabilityXXXXXXX
Low Ambient capability with KitXXXXXXX
Suction Line AccumulatorXXXXXXX
Loss of Charge SwitchXXXXXXX

X = Standard

Tested AHRI Combination Ratings: Ratings are subject to change; refer to AHRI directory (www.ahridirectory.org) and MyCarrierRatings.com for details.

Physical Data

Unit SizeCompressor TypeRefrigerantControlCharge (lb)Outdoor Htg. Piston #Cond FanAir DischargeAir Qty (CFM)Motor HPMotor RPMCond Coil Face Area (Sq ft)Fins per In.RowsCircuitsValve Connect (In. ID) VaporValve Connect (In. ID) LiquidRefrigerant Tubes* (In. OD) Rated Vapor (0-80 Ft Tube Length)Refrigerant Tubes* (In. OD) Rated Liquid Line (0-80 Ft Tube Length)
18ScrollTXV (Hard Shutoff)5.942Forward Swept or Propeller Type, Direct DriveVertical23461/1280015.020165/85/85/85/8
24ScrollTXV (Hard Shutoff)6.346Forward Swept or Propeller Type, Direct DriveVertical26521/1082517.220165/83/8"5/83/4
30ScrollTXV (Hard Shutoff)9.052Forward Swept or Propeller Type, Direct DriveVertical26521/1082515.020275/83/8"3/43/4
36ScrollTXV (Hard Shutoff)9.057Forward Swept or Propeller Type, Direct DriveVertical35501/4111015.020273/43/8"3/47/8
42ScrollTXV (Hard Shutoff)9.961Forward Swept or Propeller Type, Direct DriveVertical37161/4111017.2202103/43/8"7/87/8
48ScrollTXV (Hard Shutoff)10.865Forward Swept or Propeller Type, Direct DriveVertical37161/4111019.3202127/83/8"7/81 1/8
60ScrollTXV (Hard Shutoff)13.776Forward Swept or Propeller Type, Direct DriveVertical47791/482525.1202127/83/8"1 1/8

Vapor Line Sizing and Cooling Capacity Loss

Acceptable vapor line diameters provide adequate oil return to the compressor while avoiding excessive capacity loss. The suction line diameters shown in the chart below are acceptable for HP systems with Puron® refrigerant.

Unit Nominal Size (Btuh)Acceptable Vapor Line Diameters (In. OD)Standard ApplicationLong Line Application Requires Accessories
25 (7.62)50 (15.2)80 (24.4)80+ (24.4+)100 (30.48)125 (38.10)150 (45.72)175 (53.34)200 (60.96)225 (68.58)250 (76.20)
18,0001/21233467891012
5/801112334456
24,0005/8012333456789
3/400000111112
30,0005/812333456789
3/400111122233
7/800000111111
36,0005/812445679101113
3/400111223344
7/800000111122
42,0003/401222344566
7/800111122233
48,0003/401223455678
7/800111222334
60,0003/412445679101112
7/801222344556
1 1/800001111112

Standard Length = 80 ft. (24.4 m) or less total equivalent length.

Applications in this area are long line. Accessories are required as shown recommended on Long Line Application Guidelines.

Applications in this area may have height restrictions that limit allowable total equivalent length, when outdoor unit is below indoor unit. See Long Line Application Guidelines.

Refrigerant Piping Length Limitations

The maximum allowable total equivalent length for heat pumps varies depending on the vertical separation. Tables provide allowable lengths based on unit level, outdoor unit above, or outdoor unit below indoor unit.

Maximum Line Lengths for Heat Pump Applications

MAXIMUM ACTUAL LENGTH* ft (m)MAXIMUM EQUIVALENT LENGTH{ ft (m)MAXIMUM VERTICAL SEPARATION ft (m)
Units on equal level200 (61)250 (76.2)N/A
Outdoor unit ABOVE indoor unit200 (61)250 (76.2)200 (61)
Outdoor unit BELOW indoor unit

* Maximum actual length not to exceed 200 ft (61 m).

Maximum Total Equivalent Length* { - Outdoor Unit BELOW Indoor Unit

HP with Puron® Refrigerant - Maximum Total Equivalent Length

SizeLiquid Line Diameter w/ TXVVertical Separation ft (m) Outdoor unit BELOW indoor unit;
0-20 (0 - 6.1)21-30 (6.4 - 9.1)31-40 (9.4 - 12.2)41-50 (12.5 - 15.2)51-60 (15.5 - 18.3)61-70 (18.6 - 21.3)71-80 (21.6 - 24.4)
18,0003/8250*250*250*250*250*250*250*
24,0003/8250*250*250*250*250*250*250*
30,0003/8250*250*250*250*250*250*250*
36,0003/8250*250*250*250*250*250*250*
42,0003/8250*250*250*250*250*250*150
48,0003/8250*250*250*250*230160--
60,0003/8250*225*190150110----

*.Total equivalent length accounts for losses due to elbows or fitting. See the Long Line Guideline for details. -- = outside acceptable range

Long Line Applications

An application is considered Long Line when the refrigerant level in the system requires the use of accessories to maintain acceptable refrigerant management for systems reliability. Defining a system as long line depends on the liquid line diameter, actual length of the tubing, and vertical separation between the indoor and outdoor units.

For Heat Pump systems, the chart below shows when an application is considered Long Line. Beyond these lengths, long line accessories are required:

Liquid Line SizeUnits On Same LevelOutdoor Below IndoorOutdoor Above Indoor
3/880 (24.4)20 (6.1) vertical or 80 (24.4) total80 (24.4)

Note: See Long Line Guideline for details.

Accessories

The following accessories are available for the GH5S unit, indicated by 'X' for availability by unit size:

KIT NUMBERKIT NAME18243036424860
KAACH1701AAACrankcase HeaterXXXX
KAACH1601AAACrankcase HeaterXXS
KAATD0101TDRTime Delay RelayXXXXXXX
KHAIR0201AAAIsolation RelayXXXXXXX
KHALS0401LLSSolenoid Valve KitXXXXXXX
KHASS0606MPKSnow StandXXXXXXX
KSACY0101AAACycle ProtectorXXXXXXX
KSAFT0101AAAEvaporator Freeze StatXXXXXXX
KSAHI0401PURHigh Pressure Switch KitXXXXXXX
KSAHS2501AAAHard StartXXXXXXX
KSALA0301410Low Ambient Cooling Pressure SwitchXXXXXXX
KSALA1001AAAMotorMasterXXXXXXX
KSATX0201PURTXV KitXXX
KSATX0301PURTXV KitXX
KSATX0401PURTXV KitXX
KSBTX0201PURTXV KitXXX
KSBTX0301PURTXV KitXXX
KSBTX0401PURTXV KitXXXX
KSASH2301COPSound BlanketXXXX
KSASH2401COPSound BlanketXXX
KSASF0201AAASupport FeetXXXXXXX
KSALN0199CACBadge KitXXXXXXX
KSALN0199BRYBadge KitXXXXXXX

X = Accessory, S = Standard

Accessory Usage Guideline

This table outlines accessory requirements for Low-Ambient Cooling, Long Line Applications, and Sea Coast Applications.

AccessoryREQUIRED FOR LOW-AMBIENT COOLING APPLICATIONS (Below 55°F / 12.8°C)REQUIRED FOR LONG LINE APPLICATIONS*REQUIRED FOR SEA COAST APPLICATIONS (Within 2 miles / 3.22 km)
AccumulatorStandardStandardStandard
Ball Bearing Fan MotorStandardStandardStandard
Compressor Start Assist Capacitor and RelayYesYesNo
Crankcase HeaterYesYesNo
Evaporator Freeze ThermostatYesNoNo
Hard Shutoff TXVYesYesNo
Isolation RelayYesNoNo
Liquid Line Solenoid ValveYesYesNo
Motor Master® Control or Low Ambient SwitchNoSee Long-Line Application GuidelineNo
Support FeetRecommendedRecommendedNo

* For tubing line sets between 80 and 200 ft. (24.38 and 60.96 m) and/or 20 ft. (6.09 m) vertical differential, refer to Residential Split-System Longline Application Guideline.

† Standard on 3 phase units only.

Accessory Description and Usage

1. Ball-Bearing Fan Motor

A fan motor with ball bearings which permits speed reduction while maintaining bearing lubrication.

2. Compressor Start Assist - Capacitor and Relay

Start capacitor and relay gives a "hard" boost to compressor motor at each start up. Usage Guideline: Required for single-phase scroll compressors in the following applications: Long line, Low ambient cooling. Suggested for all compressors in areas with a history of low voltage problems.

3. Crankcase Heater

An electric resistance heater which mounts to the base of the compressor to keep the lubricant warm during off cycles. Improves compressor lubrication on restart and minimizes the chance of liquid slugging. Usage Guideline: Required in low ambient cooling applications. Required in long line applications. Suggested in all commercial applications.

4. Cycle Protector

The cycle protector is designed to prevent compressor short cycling. This control provides an approximate 5-minute delay after power to the compressor has been interrupted for any reason, including power outage, protector control trip, thermostat jiggling, or normal cycling.

5. Evaporator Freeze Thermostat

An SPST temperature-actuated switch that stops unit operation when evaporator reaches freeze-up conditions. Usage Guideline: Required when low ambient kit has been added.

6. Low-Ambient Pressure Switch Kit

A long life pressure switch which is mounted to outdoor unit service valve. It is designed to cycle the outdoor fan motor in order to maintain head pressure within normal operating limits (approximately 100 psig to 225 psig). The control will maintain working head pressure at low-ambient temperatures down to 0°F (-18°C) when properly installed and also using wind baffles. Usage Guideline: A Low-Ambient Pressure Switch must be used when cooling operation is used at outdoor temperatures below 55°F (12.8°C).

7. MotorMaster® Low-Ambient Controller

A fan-speed control device activated by a temperature sensor, designed to control condenser fan motor speed in response to the saturated, condensing temperature during operation in cooling mode only. For outdoor temperatures down to 0°F/–17.8°C), it maintains condensing temperature at 100°F ±10°F (37.8°C ±5.5°C). Usage Guideline: A MotorMaster® Low Ambient Controller or Low-Ambient Pressure Switch must be used when cooling operation is used at outdoor temperatures below 55°F (12.8°C).

8. Outdoor Air Temperature Sensor

This device enables the thermostat to display the outdoor temperature. This device is also required to enable special thermostat features such as auxiliary heat lock out. Usage Guideline: Suggested for use with compatible thermostats.

9. Sound Hood

Wraparound sound reducing cover for the compressor. Reduces the sound level of the compressor. Usage Guideline: Suggested when unit is installed closer than 15 ft (4.57 m) to quiet areas, bedrooms, etc. Suggested when unit is installed between two houses less than 10 ft (3 m) apart.

10. Support Feet

Four or five stick-on plastic feet that raise the unit 4 in. (101.6 mm) above the mounting pad. This allows sand, dirt, and other debris to be flushed from the unit base, minimizing corrosion. Usage Guideline: Suggested in the following applications: Coastal installations, Windy areas or where debris is normally circulating, Rooftop installations, For improved sound ratings.

11. Thermostatic Expansion Valve (TXV)

A modulating flow-control valve which meters refrigerant liquid flow rate into the evaporator in response to the superheat of the refrigerant gas leaving the evaporator. Kit includes valve, adapter tubes, and external equalizer tube. Hard shut off types are available. Usage Guideline: Required to achieve AHRI ratings in certain equipment combinations. Refer to combination ratings. Hard shut off TXV or LLS required in air conditioner long line applications. Required for use on all zoning systems.

12. Time-Delay Relay

An SPST delay relay which briefly continues operation of indoor blower motor to provide additional cooling after the compressor cycles off. NOTE: Most indoor unit controls include this feature. For those that do not, use the guideline below. Usage Guideline: For improved efficiency ratings for certain combinations of indoor and outdoor units. Refer to AHRI Directory of Certified Product Performance (AHRI Directory). When a Time-Delay Relay (TDR) is called for in the AHRI Directory, use a 30 second TDR for MicroChannel Indoor units and use a 90 second TDR for Round Tube Plate Fin Indoor units.

13. Winter Start Control

This control is designed to alleviate nuisance opening of the low-pressure switch by bypassing it for the first 3 minutes of operation.

Electrical Data

UNIT SIZEV/PHOPER VOLTS* MAXMINCOMPR RLALRAFAN FLAMCAMAX FUSE or CKT BRK AMPS
1810.345.70.5013.420
2411.159.50.6014.525
3014.167.90.6018.230
36208-230-125319715.383.11.2020.330
4218.6110.01.4024.740
4825.0120.01.5232.850
6025.6150.01.2033.250

* Permissible limits of the voltage range at which the unit will operate satisfactorily. † Time-Delay fuse. FLA=Full Load Amps, LRA=Locked Rotor Amps, MCA=Minimum Circuit Amps, RLA=Rated Load Amps.

NOTE: Control circuit is 24-V on all units and requires external power source. Copper wire must be used from service disconnect to unit. All motors/compressors contain internal overload protection. Complies with requirements of ASHRAE Standards 90.1. Short Circuit Current Rating (SCCR): 5kA rms.

Sound Power Level Without Sound Hood

UNIT SIZESTANDARD RATING (dBA)1252505001000200040008000
187170.266.465.167.462.858.252.5
247666.368.469.467.764.461.455.9
307670.171.370.869.664.060.654.9
367674.072.571.770.566.161.755.6
427672.172.670.067.662.960.556.0
487675.572.471.468.363.160.555.5
607665.267.067.470.062.659.755.5

NOTE: Tested in compliance with AHRI 270 but not listed with AHRI.

Sound Power Level With Sound Hood

UNIT SIZESTANDARD RATING (dBA)1252505001000200040008000
186970.666.264.865.761.257.551.3
247466.768.168.766.563.160.053.1
307471.470.570.568.363.460.353.5
367474.772.771.868.664.359.051.6
427472.873.770.367.362.659.853.4
487476.371.971.068.162.960.053.9
607365.467.567.568.861.558.552.9

NOTE: Tested in compliance with AHRI 270 but not listed with AHRI.

Charging Subcooling (TXV-Type Expansion Device)

UNIT SIZE-VOLTAGEREQUIRED SUBCOOLING °F (°C)
187 (3.9)
247 (3.9)
3012 (6.7)
3612 (6.7)
4210 (5.6)
4813 (7.2)
6010 (5.6)

HP Only Replacement with Piston Indoors

This heat pump may only be installed with piston metered indoor units as replacement components in a piston system. When installing a non-rated heat pump with a piston indoor unit, the correct piston must be installed, which should be listed in the indoor unit Installation Instructions or Product Data. Replacement pistons can be ordered from Replacement Components (RC).

Dimensions

Detailed dimensions for various GH5S models are provided in the table below. These include measurements for A through K, operating weight, and shipping weight.

UNIT SIZEA (INCH/MM)B (INCH/MM)C (INCH/MM)D (INCH/MM)E (INCH/MM)F (INCH/MM)G (INCH/MM)H (INCH/MM)K (INCH/MM)OPERATING WEIGHT Lbs/KgsSHIPPING WEIGHT Lbs/KgsSHIPPING LENGTH/WIDTH (Sq.) INCH/MMSHIPPING HEIGHT INCH/MM
GH5SA*41800A31 3/16 (792.5)28 1/4 (718.0)5/8 (15.9)6 9/16 (166.1)24 11/16 (626.3)9 1/8 (231.3)1 1/8 (28.2)3 13/16 (97.4)13 3/4 (349.3)135 / 61.1152 / 69.132 3/16 (817.9) / 29 7/8 (758.5)14 3/4 (374.7)
GH5SA*42400A31 3/16 (792.5)31 11/16 (804.3)5/8 (15.9)6 9/16 (166.1)24 11/16 (626.3)9 1/8 (231.3)1 1/8 (28.2)3 13/16 (97.4)14 (355.6)153 / 69.1162 / 73.532 3/16 (817.9) / 29 7/8 (758.5)14 1/2 (368.3)
GH5SA*43000A31 3/16 (792.5)28 1/4 (718.0)3/4 (19.1)6 9/16 (166.1)24 11/16 (626.3)9 1/8 (231.3)1 1/8 (28.2)3 13/16 (97.4)13 3/4 (349.3)173 / 78.4190 / 86.432 3/16 (817.9) / 29 7/8 (758.5)15 1/2 (393.7)
GH5SA*43600A31 3/16 (792.5)28 1/4 (718.0)3/4 (19.1)6 9/16 (166.1)24 11/16 (626.3)9 1/8 (231.3)1 1/8 (28.2)3 13/16 (97.4)14 1/2 (368.3)173 / 78.4208 / 94.432 3/16 (817.9) / 33 1/4 (844.9)12 1/4 (311.2)
GH5SA*44200A31 3/16 (792.5)31 11/16 (804.3)7/8 (22.2)6 9/16 (166.1)24 11/16 (626.3)9 1/8 (231.3)1 1/8 (28.2)3 13/16 (97.4)14 1/2 (368.3)173 / 78.4222 / 100.732 3/16 (817.9) / 33 1/4 (844.9)12 1/2 (317.5)
GH5SA*44800A31 3/16 (792.5)35 1/16 (890.7)7/8 (22.2)6 9/16 (166.1)24 11/16 (626.3)9 1/8 (231.3)1 1/8 (28.2)3 13/16 (97.4)15 (381.0)190 / 86.4235 / 106.832 3/16 (817.9) / 36 11/16 (931.3)14 3/4 (374.7)
GH5SA*46000A35 (889.0)38 7/8 (987.8)7/8 (22.2)6 9/16 (166.1)28 7/16 (722.8)9 1/8 (231.3)1 1/8 (28.2)3 13/16 (97.4)16 1/2 (419.1)202 / 91.4253 / 114.832 3/16 (817.9) / 40 9/16 (1030.4)17 1/2 (444.5)

Diagram Description: The diagram illustrates the unit's dimensions and key reference points (A-K) for measurements, along with connection types and locations.

Pad Application Dimensions: Tables specify minimum ground and roof-top mounting pad dimensions based on unit size.

Clearances

Clearance requirements are illustrated with various examples for wall installations. Recommended clearances include:

Important Note: When installing multiple units in an alcove, roof well, or partially enclosed area, ensure there is adequate ventilation to prevent re-circulation of discharge air.

Balance Point Worksheet

This graph illustrates the relationship between outdoor temperature (°F) and the unit's integrated heating capacity (MBTUH and kW). It helps determine the balance point where heating needs match the unit's output, based on indoor air at 70°F and rated CFM.

The graph displays multiple lines, each representing a different model combination (e.g., GH5SAN418**A FJ4DNXA18L*).

Detailed Cooling Capacities & Heat Pump Heating Performance

The document includes extensive tables detailing the cooling capacities and heat pump heating performance across a range of operating conditions. These tables provide data for various:

These tables are crucial for selecting the appropriate unit and verifying performance under specific environmental conditions.

Guide Specifications

General

System Description

An outdoor-mounted, air-cooled, split-system heat pump unit suitable for ground or rooftop installation. It comprises a hermetic compressor, an air-cooled coil, a propeller-type condenser fan, and a control box. The unit discharges supply air upward and is designed for integration with packaged fan coil or coil units.

Quality Assurance

Delivery, Storage, and Handling

Shipped as a single package; storage and handling follow manufacturer's recommendations.

Warranty

U.S. and Canada only (for inclusion by specifying engineer).

PRODUCTS

Equipment

Factory-assembled, single-piece, air-cooled heat pump unit containing all factory wiring, piping, controls, compressor, refrigerant charge (Puron®), and special features required for field start-up.

Unit Cabinet

Constructed of galvanized steel, coated with pre-paint. Available with dense grille only.

Fans

Direct-drive propeller type condenser fan discharging air upward. Motors are totally enclosed, 1-phase, class B insulated, permanently lubricated, with corrosion-resistant shafts. Fan blades are statically and dynamically balanced. Openings have steel wire safety guards.

Compressor

Hermetically sealed, mounted on rubber vibration isolators.

Condenser Coil

Air-cooled; constructed of aluminum fins mechanically bonded to copper or aluminum tubes, then cleaned, dehydrated, and sealed.

Refrigeration Components

Include liquid-line and vapor-line shutoff valves (sweat connections), Puron® refrigerant charge, POE compressor oil, accumulator, and reversing valve.

Operating Characteristics

Details on unit capacity, power consumption, and system performance (SEER) under various conditions are specified (blanks indicate values to be filled in by engineer).

Electrical Requirements

Nominal unit electrical characteristics (voltage, phase, Hz) are specified, with acceptable voltage limits. Unit power is single-point connection; control circuit is 24v.

Special Features

Refer to literature for descriptions of specific features and available enhancements.

System Design Summary

  1. Intended for outdoor installation with free air inlet and outlet; outdoor fan external static pressure < 0.01-in. wc.
  2. Minimum outdoor operating air temperature without low-ambient accessory: 55°F (12.8°C).
  3. Maximum outdoor operating air temperature for cooling: 125°F (51.7°C).
  4. Minimum outdoor operating air temperature for heating: -10°F (-23.3°C).
  5. Maximum outdoor operating air temperature for heating: 66°F (18.9°C).
  6. Unit must be level in all horizontal planes for reliable operation.
  7. For tubing lengths > 80 ft (23.4 m) and/or elevation differences > 20 ft (6.1 m), consult Residential Piping and Longline Guideline and Service Manual.
  8. If refrigerant tubing is buried, provide a 6 in. (152.4 mm) vertical rise to valve connections. Buried lines up to 36 in. (914.4 mm) are permissible.
  9. Use only copper wire for electric connections; aluminum and clad aluminum are not acceptable.
  10. Do not apply capillary tube indoor coils to these units.
  11. Factory-supplied filter drier must be installed.

File Info : application/pdf, 18 Pages, 3.08MB

PDF preview unavailable. Download the PDF instead.

gh5s-01pd

References

Adobe PDF Library 15.0

Related Documents

Preview Carrier 25HCE4 Comfort 14 Heat Pump: Product Data, Specifications, and Performance
Comprehensive product data, features, specifications, installation guidelines, and performance ratings for the Carrier 25HCE4 Comfort 14 Heat Pump with Puron® Refrigerant. Includes details on efficiency, sound, comfort, reliability, durability, applications, accessories, electrical data, and AHRI ratings.
Preview Carrier Performance Series Horizontal Heat Pumps 38MURA - Efficient & Quiet Comfort
Discover the Carrier Performance Series horizontal heat pumps, model 38MURA. Featuring high SEER2 and HSPF2 ratings for energy efficiency, ultra-quiet operation, and durable design. Learn about Carrier's commitment to innovation and environmental responsibility.
Preview Carrier 26SCA5 Comfort™ Series Air Conditioner Product Data
Explore the Carrier 26SCA5 Comfort™ Series Single-Stage Air Conditioner, featuring Puron Advance™ Refrigerant. This document provides detailed product data, features, benefits, specifications, and performance ratings for various models.
Preview Carrier GH5S Single-Stage Heat Pump Installation Instructions
Comprehensive installation guide for the Carrier GH5S Single-Stage Heat Pump with R-410A Refrigerant, covering safety considerations, installation recommendations, piping connections, electrical wiring, startup procedures, and charging methods.
Preview Carrier 25TPA7 Performance Series 2-Stage Heat Pump Installation Guide
This document provides detailed installation instructions for the Carrier 25TPA7 Performance Series 2-Stage Heat Pump with Puron Refrigerant. It covers critical safety considerations, installation recommendations, step-by-step procedures for piping, electrical connections, evacuation, and refrigerant charging, along with operational sequences and basic troubleshooting tips.
Preview Carrier GA4S Single-Stage Air Conditioner Product Data and Specifications
Explore the Carrier GA4S single-stage air conditioner, featuring Puron® refrigerant, SEER2 ratings from 13.4 to 16.0, and capacities from 1-1/2 to 5 tons. This document provides detailed product data, specifications, and performance ratings.
Preview Carrier 50NT-B Heat Pump Installation Instructions
Comprehensive installation guide for the Carrier 50NT-B Comfort™ 13.4 SEER2 Single-Packaged Heat Pump System with Puron Advance™ (R-454B) refrigerant. Covers safety, receiving, installation, start-up, maintenance, troubleshooting, and decommissioning.
Preview Carrier GA5S Single-Stage Air Conditioner - Features, Specs, and Installation
Discover the Carrier GA5S single-stage air conditioner, featuring Puron refrigerant, scroll compressor, and high efficiency ratings (SEER2). This document provides detailed specifications, model information, installation guidelines, and performance data for the GA5S series.