25HCE4 Comfort™ 14 Heat Pump

with Puron® Refrigerant

1-1/2 to 5 Nominal Tons

Product Data

Carrier heat pumps with Puron® refrigerant provide a collection of features unmatched by any other family of equipment. The 25HCE4 has been designed utilizing Carrier's non-ozone depleting Puron® refrigerant.

NOTE: Ratings contained in this document are subject to change at any time. Always refer to the AHRI directory (www.ahridirectory.org) for the most up-to-date ratings information.

INDUSTRY LEADING FEATURES / BENEFITS

Efficiency

Sound

Comfort

Reliability

Durability

WeatherArmor™ protection package:

Applications

Model Number Nomenclature

The model number nomenclature provides a breakdown of unit features. For example, the first digit "N" indicates the product series, "25" indicates HP (Heat Pump), "H" indicates RES HP, "C" indicates Comfort Series, "E" indicates Puron refrigerant, and "4" indicates 14 SEER.

1 2 3 4 5 6 7 8 9 10 11 12 13
N N A A A/N N N N A/N A/N A/N N N
25 H C E 4 3 6 A 0 0 3 0 0
Product Series Product Family Tier Major Series SEER Cooling Capacity Grille Variations Open Outdoor Tube Voltage Minor Series
25 = HP H = RES HP C=Comfort E = Puron 4=14 SEER (Capacity in kBTU/hr) A=Dense Grille 0=Not Defined 0=Copper L = Aluminum 3=208-230-1 5=208/230-3 6=460/3 (Model specific)

Certifications: Puron®, AHRI Certified™ Mark, UL Listed, C-UL Listed.

Standard Features

Feature 18 24 30 36 42 48 60
Puron Refrigerant X X X X X X X
Scroll Compressor X X X X X X X
Field Installed Filter Drier X X X X X X X
Front Seating Service Valves X X X X X X X
Internal Pressure Relief Valve X X X X X X X
Internal Thermal Overload X X X X X X X
Long Line capability X X X X X X X
Low Ambient capability with Kit X X X X X X X
Suction Line Accumulator X X X X X X X
High Pressure Switch X X X X X X X
Loss of Charge Switch X X X X X X X

X = Standard

Physical Data

This section details the physical characteristics and refrigerant requirements for various unit sizes.

UNIT SIZE - Voltage, Series Compressor Type REFRIGERANT Control Outdoor Heating Piston # Charge lb (kg) COND FAN Motor HP Motor RPM CFM VALVE CONNECT. (In. ID) Vapor VALVE CONNECT. (In. ID) Liquid REFRIGERANT TUBES* (In. OD) Rated Vapor REFRIGERANT TUBES* (In. OD) Max Liquid Line
18-30 Scroll Puron® (R-410A) TXV (Puron Hard Shutoff) 42 5.30 (2.4) Forward Swept or Propeller Type, Direct Drive 1/12 1100 1700 5/8 3/8 5/8 3/8
24-30 Scroll Puron® (R-410A) TXV (Puron Hard Shutoff) 46 5.60 (2.5) Forward Swept or Propeller Type, Direct Drive 1/10 1100 2195 5/8 3/8 5/8 3/8
30-30 Scroll Puron® (R-410A) TXV (Puron Hard Shutoff) 49 6.40 (2.9) Forward Swept or Propeller Type, Direct Drive 1/4 1100 3365 3/4 3/8 3/4 3/8
36-31, 51, 61
36-L30
Scroll Puron® (R-410A) TXV (Puron Hard Shutoff) 57 7.67 (3.48) Forward Swept or Propeller Type, Direct Drive 1/5 1100 3165 3/4 3/8 3/4 3/8
42-30
42-L30
Scroll Puron® (R-410A) TXV (Puron Hard Shutoff) 61 8.25 (3.74) Forward Swept or Propeller Type, Direct Drive 1/4 1100 3800 7/8 3/8 7/8 3/8
48-30, 50, 60 Scroll Puron® (R-410A) TXV (Puron Hard Shutoff) 65 8.68 (3.94) Forward Swept or Propeller Type, Direct Drive 1/4 800 4470 7/8 3/8 1-1/8 3/8
60-30 Scroll Puron® (R-410A) TXV (Puron Hard Shutoff) 78 10.60 (4.81) Forward Swept or Propeller Type, Direct Drive 1/4 800 4470 7/8 3/8 1-1/8 3/8
60-50, 60 Scroll Puron® (R-410A) TXV (Puron Hard Shutoff) 78 10.60 (4.81) Forward Swept or Propeller Type, Direct Drive 1/4 800 4470 7/8 3/8 1-1/8 3/8

*Units are rated with 25 ft (7.6 m) of lineset length. See Vapor Line Sizing and Cooling Capacity Loss table when using other sizes and lengths of lineset.

Note: See unit Installation Instruction for proper installation.

Vapor Line Sizing and Cooling Capacity Loss

Acceptable vapor line diameters provide adequate oil return to the compressor while avoiding excessive capacity loss. The suction line diameters shown in the chart below are acceptable for HP systems with Puron refrigerant:

Vapor Line Sizing and Cooling Capacity Losses - Puron® Refrigerant 1- Stage Heat Pump Applications

Unit Nominal Size (Btuh) Acceptable Vapor Line Diameters (In. OD) Cooling Capacity Loss (%) Total Equivalent Line Length (ft)
Standard Application 25 (7.62) 50 (15.2) 80 (24.4) 80+ (24.4+) 100 (30.48) 125 (38.10) 150 (45.72) 175 (53.34) 200 (60.96) 225 (68.58) 250 (76.20)
18,000 1/2 1 2 3 3 4 6 7 8 9 10 12
5/8 0 0 1 1 1 1 2 2 3 3 3
24,000 5/8 0 1 1 1 2 3 3 4 4 5 6
3/4 0 0 0 0 0 1 1 1 1 1 2
30,000 5/8 1 2 3 3 3 4 5 6 7 8 9
3/4 0 0 1 1 1 1 2 2 2 3 3
7/8 0 0 0 0 0 1 1 1 1 1 1
36,000 5/8 1 2 4 4 5 6 7 9 10 11 13
3/4 0 0 1 1 1 2 2 3 3 4 4
7/8 0 0 0 0 0 1 1 1 1 2 2
42,000 3/4 0 1 2 2 2 3 4 4 5 6 6
7/8 0 0 1 1 1 1 2 2 2 3 3
48,000 3/4 0 1 2 2 3 4 5 5 6 7 8
7/8 0 0 1 1 1 2 2 2 3 3 4
60,000 3/4 1 2 4 4 5 6 7 9 10 11 12
7/8 0 1 2 2 2 3 4 4 5 5 6
1 1/8 0 0 0 0 1 1 1 1 1 1 2

Standard Length = 80 ft. (24.4 m) or less total equivalent length.

Applications in this area are long line. Accessories are required as shown recommended on Long Line Application Guidelines.

Applications in this area may have height restrictions that limit allowable total equivalent length, when outdoor unit is below indoor unit. See Long Line Application Guidelines.

Refrigerant Piping Length Limitations

Maximum Line Lengths for Heat Pump Applications

MAXIMUM ACTUAL LENGTH ft (m) MAXIMUM EQUIVALENT LENGTH† ft (m) MAXIMUM VERTICAL SEPARATION ft (m)
Units on equal level 200 (61) 250 (76.2) N/A
Outdoor unit ABOVE indoor unit 200 (61) 250 (76.2) 200 (61)
Outdoor unit BELOW indoor unit See Table 'Maximum Total Equivalent Length: Outdoor Unit BELOW Indoor Unit'

† Total equivalent length accounts for losses due to elbows or fitting. See the Long Line Guideline for details.

Maximum Total Equivalent Length† - Outdoor Unit BELOW Indoor Unit

HP with Puron® Refrigerant - Maximum Total Equivalent Length†

Size Liquid Line Diameter w/ TXV Vertical Separation ft (m) Outdoor unit BELOW indoor unit;
0-20 (0-6.1) 21-30 (6.4-9.1) 31-40 (9.4-12.2) 41-50 (12.5-15.2) 51-60 (15.5-18.3) 61-70 (18.6-21.3) 71-80 (21.6-24.4)
18,000 3/8 250* 250* 250* 250* 250* 250* 250*
24,000 3/8 250* 250* 250* 250* 250* 250* 250*
30,000 3/8 250* 250* 250* 250* 250* 250* 250*
36,000 3/8 250* 250* 250* 250* 250* 250* 250*
42,000 3/8 250* 250* 250* 250* 250* 250* 150
48,000 3/8 250* 250* 250* 250* 230 160 -
60,000 3/8 250* 225* 190 150 110 - -

* Maximum actual length not to exceed 200 ft (61 m).

† Total equivalent length accounts for losses due to elbows or fitting. See the Long Line Guideline for details.

LONG LINE APPLICATIONS

An application is considered Long Line when the refrigerant level in the system requires the use of accessories to maintain acceptable refrigerant management for systems reliability. Defining a system as long line depends on the liquid line diameter, actual length of the tubing, and vertical separation between the indoor and outdoor units.

For Heat Pump systems, the chart below shows when an application is considered Long Line. Beyond these lengths, long line accessories are required:

HP WITH PURON® REFRIGERANT LONG LINE DESCRIPTION ft (m)

Beyond these lengths, long line accessories are required:

Liquid Line Size Units On Same Level Outdoor Below Indoor Outdoor Above Indoor
3/8 80 (24.4) 20 (6.1) vertical or 80 (24.4) total 80 (24.4)

Note: See Long Line Guideline for details.

Accessories

A variety of accessories are available to enhance unit performance and functionality.

ORDER NUMBER KIT DESCRIPTION 18-3 24-3 30-3 36-3 36-L3 36-5 36-6 42-3 42-L3 48-3 48-5 48-6 60-3 60-5 60-6
KAACH1601AAA CRANKCASE HTR X X X X
KAACH1701AAA CRANKCASE HTR X X X S S S S S S S S S
KAACS0201PTC KIT PTC X X X X X X X X X X X X X X X
KAATD0101TDR TIME DELAY RELAY X X X X X X X X X X X X X X X
KHAIR0201AAA ISOLATION RELAY X X X X X X X X X X X X X X X
KHALS0401LLS SOLENOID VALVE X X X X X X X X X X X X X X X
KHASS0606MPK SNOW STAND X X X X X X X X X X X X X X X
KSACY0101AAA CYCLE PROT X X X X X X X X X X X X X X X
KSAFT0101AAA FREEZE TSTAT X X X X X X X X X X X X X X X
KSAHS2501AAA HARD START X X X X X
KSAHS2701AAA HARD START X X X X X X X X X
KSALA0301410 LOW AMBIENT X X X X X X X X X X X X X X X
KSALA0601AAA MOTORMASTER X X X X X X X X X X X X X X X
KSALA0701AAA MOTORMASTER X X X
KSASF0201AAA SUPPORT FEET X X X X X X X X X X X X X X X
KSASH2301COP SOUND BLANKET X X X X X X
KSASH2401COP SOUND BLANKET X X
KSATX0201PUR TXV KIT X
KSATX0301PUR TXV KIT X X X X
KSATX0401PUR TXV KIT X X X X X
KSBTX0201PUR TXV KIT X
KSBTX0301PUR TXV KIT X X
KSBTX0401PUR TXV KIT X X

X = Accessory, S = Standard

Accessory Thermostats

Part Number Description Gas Electric Heat Pump Heat Stages Cooling Stages
TP-WEM01 CÔR™, Wi-Fi Programmable Relative Humidity Thermostat X X X 4 2
TP-PRH01-A edge™ Programmable Relative Humidity Thermostat X X X 3 2
TP-PHP01 edge™ Programmable Thermostat (HP or AC) X X 3 2
TP-NRH01 edge™ Non-Programmable Relative Humidity Thermostat X X X 3 2
TP-NHP01 edge™ Non-Programmable Thermostat (HP or AC) X X 3 2
TC-WHS01 Wi-Fi® Programmable X X X 3 2
TC-PHP01 Programmable Thermostat (HP or AC) X X 3 2
TC-NHP01 Non-Programmable Thermostat (HP or AC) X X 3 2
TB-PHP01 Programmable Thermostat (HP or AC) X X 2 1
TB-NHP01 Non-Programmable Thermostat (HP or AC) X X 2 1

Thermostat Accessories

Part Number Description Used With
TP-EXP EXP® Card for Programmable Thermostats TP-Pxx
TSTATXXCNV10 Thermostat Conversion Kit (4 to 5 wire) 10 pack All Carrier branded thermostats
TX-LBP01 Large Decorative Backplate TP-Pxx, TP-Nxx, TC-Pxx
TX-MBP01 Medium Decorative Backplate TC-Nxx, TB-Pxx
TX-SBP01 Small Decorative Backplate TB-Nxx

Accessory Usage Guideline

Accessory REQUIRED FOR LOW-AMBIENT COOLING APPLICATIONS (Below 55°F / 12.8°C) REQUIRED FOR LONG LINE APPLICATIONS* REQUIRED FOR SEA COAST APPLICATIONS (Within 2 miles / 3.22 km)
Accumulator Standard Standard Standard
Ball Bearing Fan Motor Yes† Yes** No‡
Compressor Start Assist Capacitor and Relay Yes** No** No‡
Crankcase Heater Yes‡ Yes‡ No‡
Evaporator Freeze Thermostat Yes No No
Hard Shutoff TXV Yes Yes No
Isolation Relay No Yes No
Liquid Line Solenoid Valve Yes See Long-Line Application Guideline No
Motor Master® Control or Low Ambient Switch Yes No No
Support Feet Recommended No Recommended

* For tubing line sets between 80 and 200 ft. (24.38 and 60.96 m) and/or 20 ft. (6.09 m) vertical differential, refer to Residential Split-System Longline Application Guideline.

† Additional requirement for Low-Ambient Controller (full modulation feature) MotorMaster® Control.

‡ Standard for 3 phase units only

** Not required for 3-phase units.

Accessory Description and Usage (Listed Alphabetically)

  1. Ball-Bearing Fan Motor: A fan motor with ball bearings which permits speed reduction while maintaining bearing lubrication. Usage Guideline: Required on all units when using MotorMaster®.
  2. Compressor Start Assist - Capacitor and Relay: Start capacitor and relay gives a hard boost to compressor motor at each start up. Usage Guideline: Required for reciprocating compressors in the following applications: Long line, Low ambient cooling, Hard shut off expansion valve on indoor coil, Liquid line solenoid on indoor coil. Required for single-phase scroll compressors in the following applications: Long line, Low ambient cooling. Suggested for all compressors in areas with a history of low voltage problems.
  3. Compressor Start Assist - PTC Type: Solid state electrical device which gives a soft boost to the compressor at each start-up. Usage Guideline: Suggested for single phase unit installations with marginal power supply.
  4. Crankcase Heater: An electric resistance heater which mounts to the base of the compressor to keep the lubricant warm during off cycles. Improves compressor lubrication on restart and minimizes the chance of liquid slugging. Usage Guideline: Required in low ambient cooling applications. Required in long line applications. Suggested in all commercial applications.
  5. Evaporator Freeze Thermostat: An SPST temperature-actuated switch that stops unit operation when evaporator reaches freeze-up conditions. Usage Guideline: Required when low ambient kit has been added.
  6. Isolation Relay: An SPDT relay which switches the low-ambient controller out of the outdoor fan motor circuit when the heat pump switches to heating mode. Usage Guideline: Required in all heat pumps where low ambient kit has been added.
  7. Liquid-Line Solenoid Valve (LLS): An electrically operated shutoff valve which stops and starts refrigerant liquid flow in response to compressor operation. It is to be installed at the outdoor unit to control refrigerant off cycle migration in the heating mode. Usage Guideline: An LLS is required in all long line heat pump applications to control refrigerant off cycle migration in the heating mode. See Long Line Guideline.
  8. Low-Ambient Pressure Switch Kit: A long life pressure switch which is mounted to outdoor unit service valve. It is designed to cycle the outdoor fan motor in order to maintain head pressure within normal operating limits. The control will maintain working head pressure at low-ambient temperatures down to 0°F (-18°C) when properly installed. Usage Guideline: A Low-Ambient Pressure Switch or MotorMaster® Low-Ambient Controller must be used when cooling operation is used at outdoor temperatures below 55°F (12.8°C).
  9. MotorMaster® Low-Ambient Controller: A fan-speed control device activated by a temperature sensor, designed to control condenser fan motor speed in response to the saturated, condensing temperature during operation in cooling mode only. For outdoor temperatures down to -20°F (-28.9°C), it maintains condensing temperature at 100°F ±10°F (37.8°C ± 6.5°C). Usage Guideline: A MotorMaster® Low Ambient Controller or Low-Ambient Pressure Switch must be used when cooling operation is used at outdoor temperatures below 55°F (12.8°C). Suggested for all commercial applications.
  10. Outdoor Air Temperature Sensor: Designed for use with Carrier Thermostats listed in this publication. This device enables the thermostat to display the outdoor temperature. This device also is required to enable special thermostat features such as auxiliary heat lock out. Usage Guideline: Suggested for all Carrier thermostats listed in this publication.
  11. Outdoor Thermostat: An SPDT temperature-actuated switch which turns on supplemental electric heaters when outdoor air temperature drops below a user-selected set point. Usage Guideline: Electric supplemental heat applications in non-variable speed indoor units when electric heat staging is desired.
  12. Secondary Outdoor Thermostat: An SPDT temperature-actuated switch which turns on third-stage of supplemental electric heaters when outdoor air temperature drops below the second-stage set point. Usage Guideline: Outdoor thermostat applications where electric heater is capable of 3-stage operation.
  13. Snow Stand Rack: Coated wire rack which supports unit 18 in. (457.2 mm) above mounting pad to allow for drainage from unit base. Usage Guideline: Suggested in the following applications: Heat pump installations in heavy snowfall areas, Heat pump installations in snow drift locations, Heat pump installations in areas of prolonged subfreezing temperatures, All commercial installations.
  14. Sound Hood: Wraparound sound reducing cover for the compressor. Reduces the sound level by about 2 dBA. Usage Guideline: Suggested when unit is installed closer than 15 ft. (4.577 m) to quiet areas, bedrooms, etc. Suggested when unit is installed between two houses less than 10 ft. (3.05 m) apart.
  15. Thermostatic Expansion Valve (TXV) Bi-Flow: A modulating flow-control valve which meters refrigerant liquid flow rate into the evaporator in response to the superheat of the refrigerant gas leaving the evaporator. Usage Guideline: Accessory required to meet AHRI rating and system reliability, where indoor not equipped. Required in all heat pump applications designed with Puron refrigerant.
  16. Time-Delay Relay: An SPST delay relay which briefly continues operation of indoor blower motor to provide additional cooling after the compressor cycles off. Note: Most indoor unit controls include this feature. For those that do not, use the guideline below. Usage Guideline: Accessory required to meet AHRI rating, where indoor not equipped.

Electrical Data

This table provides electrical characteristics for various unit sizes and voltages.

UNIT SIZE --Voltage, Series V/PH OPER VOLTS* MAX MIN COMPR FAN MCA MAX FUSE** or CKT BRK AMPS
LRA RLA FLA
18-30 208-230-1 253 197 48.0 9.00 0.50 11.8 20
24-30 62.9 10.90 0.60 14.2 25
30-30 72.5 13.50 1.40 18.3 30
36-31, 36-L30 208-230-1 253 197 75.0 15.10 1.10 20.0 30
42-30, 42-L30 105.5 18.10 1.40 24.0 40
48-30 108.0 19.00 1.40 25.2 40
60-30 144.2 24.40 1.52 32.0 50
36-51 208/230-3 253 187 70.0 8.46 1.10 11.7 20
48-50 123.0 10.44 1.40 14.5 25
60-50 110.0 15.96 1.52 21.5 30
36-61 460-3 506 414 31.0 3.85 0.60 5.4 15
48-60 60.0 6.00 0.77 8.3 15
60-60 52.0 7.75 0.77 10.5 15

* Permissible limits of the voltage range at which the unit will operate satisfactorily.

** Time-Delay fuse.

FLA = Full Load Amps, LRA = Locked Rotor Amps, MCA = Minimum Circuit Amps, RLA = Rated Load Amps.

NOTE: Control circuit is 24-V on all units and requires external power source. Copper wire must be used from service disconnect to unit. All motors/compressors contain internal overload protection. Complies with 2007 requirements of ASHRAE Standards 90.1.

A-WEIGHTED SOUND POWER WITHOUT SOUND HOOD

UNIT SIZE-VOLTAGE, SERIES STANDARD RATING (dBA) TYPICAL OCTAVE BAND SPECTRUM (dB, without tone adjustment)
125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz
18-30 69 65 64 65 67 59 57 54
24-30 76 66 70 70 70 67 64 55
30-30 77 71 74 75 73 69 66 61
36-31, 51, 61, 36-L30 78 76 75 75 73 69 67 62
42-30, 42-L30 76 70 74 71 71 65 64 58
48-30, 50, 60 79 72 78 77 76 70 67 61
60-30 73 71 74 71 69 64 61 58
60-50, 60 76 73 74 72 72 69 64 63

NOTE: Tested in accordance with AHRI Standard 270-08 (not listed in AHRI).

A-WEIGHTED SOUND POWER WITH SOUND HOOD

UNIT SIZE-VOLTAGE, SERIES STANDARD RATING (dBA) TYPICAL OCTAVE BAND SPECTRUM (dB, without tone adjustment)
125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz
18-30 68 66 65 64 65 59 56 52
24-30 74 67 70 70 68 65 61 56
30-30 77 72 74 75 72 69 66 60
36-31, 51, 61, 36-L30 78 76 76 76 73 69 65 60
42-30, 42-L30 74 71 74 70 70 65 62 56
48-30, 50, 60 79 73 79 77 75 70 67 61
60-30 73 72 75 70 68 63 60 55
60-50, 60 76 72 72 71 72 69 64 63

NOTE: Tested in accordance with AHRI Standard 270-08 (not listed in AHRI).

CHARGING SUBCOOLING (TXV-TYPE EXPANSION DEVICE)

UNIT SIZE-VOLTAGE REQUIRED SUBCOOLING °F (°C)
18-3 11 (6.1)
24-3 11 (6.1)
30-3 10 (5.6)
36-3, 36-L3 10 (5.6)
36-51, 61 11 (6.1)
42-3, 42-L3 10 (5.6)
48-3, 5, 6 14 (7.8)
60-3, 5, 6 15 (8.3)

HP ONLY REPLACEMENT WITH PISTON INDOORS

When the 25HCE4 is used as a replacement component in a system with a piston fan coil, use the indoor piston size specified below:

UNIT SIZE FB4CNF PISTON SIZE FFM FPMA
18 0.052 0.050 0.050
24 0.057 0.057 0.056
30 0.067 0.070 0.067
36 0.070 0.072 0.069
42 0.078
48 0.084
60 = N/A

Dimensions

The following table provides the physical dimensions for various 25HCE4 unit models. A diagram illustrating these dimensions is also provided.

Diagram Description: A diagram showing the side and top views of the outdoor heat pump unit, with labels indicating dimensions A through K. Key dimensions like height, width, depth, and connection sizes are detailed.

UNIT SERIES ELECTRICAL CHARACTERISTICS A B C D E F G H I J K OPERATING WEIGHT SHIPPING WEIGHT SHIPPING LENGTH / WIDTH (Sq.) SHIPPING HEIGHT
INCH MM INCH MM INCH MM INCH MM INCH MM INCH MM INCH MM INCH MM INCH MM INCH MM INCH MM Lbs Kgs Lbs Kgs INCH MM INCH MM
25HCE418A0030011 0 Y N N N 23 1/8 587.3 35 1/2 902.0 5/8 15.9 4 7/16 113.0 18 1/16 459.0 7 13/16 197.9 1 1/8 28.2 3 13/16 97.4 11 279.4 15 3/4 400.1 12 304.8 136 61.7 166 75.3 25 1/4 641.5 40 1015.8
25HCE424A0030011 0 Y N N N 25 3/4 654.0 35 1/2 901.4 5/8 15.9 4 7/16 113.0 21 1/4 539.9 9 1/8 231.3 1 1/8 28.2 3 13/16 97.4 12 304.8 13 1/4 336.6 13 1/2 342.9 144 65.3 175 79.4 27 7/8 708.2 40 1015.8
25HCE430A0030011 0 Y N N N 31 3/16 792.5 32 1/16 815.1 3/4 19.1 6 9/16 166.1 24 11/16 626.3 9 1/8 231.3 1 1/8 28.2 3 13/16 97.4 15 381.0 11 279.4 16 406.4 158 71.7 180 81.6 33 5/16 846.6 36 5/8 929.5
25HCE436A0031011 1 Y N N N 31 3/16 792.5 28 11/16 728.7 3/4 19.1 6 9/16 166.1 24 11/16 626.3 9 1/8 231.3 1 1/8 28.2 3 13/16 97.4 15 3/4 400.1 14 355.6 10 3/4 273.1 170 77.1 201 91.2 33 5/16 846.6 33 3/16 843.1
25HCE436A0L30011 0 Y N N N 31 3/16 792.5 28 11/16 728.7 3/4 19.1 6 9/16 166.1 24 11/16 626.3 9 1/8 231.3 1 1/8 28.2 3 13/16 97.4 15 3/4 400.1 14 1/4 362.0 12 1/2 317.5 170 76.9 202 91.4 33 5/16 846.6 33 3/16 843.1
25HCE436A0051011 1 N Y N N 31 3/16 792.5 28 11/16 728.7 3/4 19.1 6 9/16 166.1 24 11/16 626.3 9 1/8 231.3 1 1/8 28.2 3 13/16 97.4 15 3/4 400.1 14 355.6 10 3/4 273.1 170 77.1 201 91.2 33 5/16 846.6 33 3/16 843.1
25HCE436A0061011 1 N N Y N 31 3/16 792.5 28 11/16 728.7 3/4 19.1 6 9/16 166.1 24 11/16 626.3 9 1/8 231.3 1 1/8 28.2 3 13/16 97.4 15 3/4 400.1 14 355.6 10 3/4 273.1 170 77.1 201 91.2 33 5/16 846.6 33 3/16 843.1
25HCE442A0030011 0 Y N N N 31 3/16 792.5 38 7/8 987.8 7/8 22.2 6 9/16 166.1 24 11/16 626.3 9 1/8 231.3 1 1/8 28.2 3 13/16 97.4 15 1/2 393.7 13 1/2 342.9 14 355.6 201 91.2 235 106.6 33 5/16 846.6 43 3/8 1102.2
25HCE442A0L30011 0 Y N N N 31 3/16 792.5 38 7/8 987.8 7/8 22.2 6 9/16 166.1 24 11/16 626.3 9 1/8 231.3 1 1/8 28.2 3 13/16 97.4 14 5/8 371.5 16 1/8 409.6 17 431.8 190 86.0 225 101.8 33 5/16 846.6 43 3/8 1102.2
25HCE448A0030011 0 Y N N N 31 3/16 792.5 28 11/16 728.7 7/8 22.2 6 9/16 166.1 24 11/16 626.3 9 1/8 231.3 1 1/8 28.2 3 13/16 97.4 16 1/2 419.1 11 1/2 292.1 15 381.0 197 89.4 232 105.2 33 5/16 846.6 33 3/16 843.1
25HCE448A0050011 0 N Y N N 31 3/16 792.5 28 11/16 728.7 7/8 22.2 6 9/16 166.1 24 11/16 626.3 9 1/8 231.3 1 1/8 28.2 3 13/16 97.4 16 1/2 419.1 11 1/2 292.1 15 381.0 197 89.4 232 105.2 33 5/16 846.6 33 3/16 843.1
25HCE448A0060011 0 N N Y N 31 3/16 792.5 28 11/16 728.7 7/8 22.2 6 9/16 166.1 24 11/16 626.3 9 1/8 231.3 1 1/8 28.2 3 13/16 97.4 16 1/2 419.1 11 1/2 292.1 15 381.0 197 89.4 232 105.2 33 5/16 846.6 33 3/16 843.1
25HCE460A0030011 0 Y N N N 31 3/16 792.5 32 1/16 815.1 7/8 22.2 6 9/16 166.1 24 11/16 626.3 9 1/8 231.3 1 1/8 28.2 3 13/16 97.4 14 3/4 374.7 15 3/4 400.1 16 1/4 412.8 212 96.2 248 112.5 33 5/16 846.6 36 5/8 929.5
25HCE460A0050011 0 N Y N N 31 3/16 792.5 32 1/16 815.1 7/8 22.2 6 9/16 166.1 24 11/16 626.3 9 1/8 231.3 1 1/8 28.2 3 13/16 97.4 14 3/4 374.7 15 3/4 400.1 16 1/4 412.8 212 96.2 248 112.5 33 5/16 846.6 36 5/8 929.5
25HCE460A0060011 0 N N Y N 31 3/16 792.5 32 1/16 815.1 7/8 22.2 6 9/16 166.1 24 11/16 626.3 9 1/8 231.3 1 1/8 28.2 3 13/16 97.4 14 3/4 374.7 15 3/4 400.1 16 1/4 412.8 212 96.2 248 112.5 33 5/16 846.6 36 5/8 929.5

NOTES:

  1. ALLOW 24" (609.6) CLEARANCE TO SERVICE SIDE OF UNIT, 48" (1219.2) ABOVE UNIT, 6" (152.4) ON ONE SIDE, 12" (304.8) ON REMAINING SIDE, AND 24" (609.6) BETWEEN UNITS FOR PROPER AIRFLOW.
  2. CENTER OF GRAVITY .
  3. SERIES DESIGNATION IS THE 13TH POSITION OF THE UNIT MODEL NUMBER.
UNIT SIZE "X" MINIMUM GROUND MOUNTING PAD APPLICATION DIMENSIONS "Y" MINIMUM ROOF-TOP MOUNTING PAD APPLICATION DIMENSIONS
INCH MM INCH MM
18 23 1/8 587.3 17 7/8 454.6
24 25 3/4 654.0 20 7/16 518.5
30,36,42,48,60 31 3/16 792.5 22 15/16 583.2
- 35 889.0 26 3/4 679.7

NOTE: ALL DIMENSIONS IN INCH (MM)

U.S. ECCN: Not Subject to Regulation (N.S.R.)

Clearances

Diagram Description: Diagrams illustrating recommended clearances around the outdoor unit for proper installation and airflow. Clearances are shown for service access, sides, and between multiple units.

Note: Numbers in () = mm

IMPORTANT: When installing multiple units in an alcove, roof well, or partially enclosed area, ensure there is adequate ventilation to prevent re-circulation of discharge air.

Balance Point Worksheet

Diagram Description: A graph titled "BALANCE POINT WORKSHEET" plotting Building Heat Loss and Unit Integrated Heating Capacity (MBTUH) against Outdoor Temperature (°F and °C). Several curves represent different model numbers (e.g., 25HCE460, 25HCE448, etc.), showing their heating capacity at various outdoor temperatures. The graph is based on indoor entering air at 70°F (21.1°C) and at rated CFM.

Tested AHRI Combination Ratings

NOTE: Ratings contained in this document are subject to change at any time.

For AHRI ratings certificates, please refer to the AHRI directory www.ahridirectory.org

Additional ratings and system combinations can be accessed via the Carrier database at: www.MyCarrierRatings.com

For performance data at specific application &/or design conditions with various indoor unit combinations, the equipment performance calculator can be accessed at : http://rpmob.wrightsoft.com/

Model Number Indoor Coil Model Number Cooling Capacity EER SEER High Temp HSPF Low Temp
E Capacity E COP H Capacity H COP
25HCE418A**30 FB4CNP018L 17,800 11.5 14 17,600 3.72 8.2 10,400 2.40
25HCE424A**30 FB4CNP030L 22,200 11.5 14 22,200 3.84 8.2 13,200 2.54
25HCE430A**30 FB4CNP030L 28,600 11.5 14 28,600 3.62 8.2 17,100 2.44
25HCE436A**31 FB4CNP036L 33,000 11.5 14 33,800 3.62 8.2 20,800 2.40
25HCE436A*L30 FB4CNP036L 33,000 11.5 14 33,800 3.62 8.2 20,800 2.44
25HCE436A**51, 61 FB4CNP036L 33,000 11.0 14 33,000 3.64 8.2 20,800 2.46
25HCE442A**30 FB4CNP042L 40,000 11.5 14 41,000 3.62 8.2 25,200 2.50
25HCE448A**30, 50, 60 FB4CNP048L 46,000 11.5 14 45,500 3.64 8.2 27,800 2.56
25HCE460A**30, 50, 60 FX4DN(B,F)061L 57,000 11.5 14 54,500 3.70 8.2 33,000 2.56

Cooling Standard: 80°F (27°C) db 67°F (19°C) wb indoor entering air temperature and 95°F (35°C) db air entering outdoor unit.

High-Temp Heating Standard: 70°F (21°C) db indoor entering air temperature and 47°F (8°C) db 43°F (6°C) wb air entering outdoor unit.

Low-Temp Heating Standard: 70°F (21°C) db indoor entering air temperature and 17°F (-8°C) db 15°F (-9°C) wb air entering outdoor unit.

COP - Coefficient of Performance

EER - Energy Efficiency Ratio

HSPF - Heating Seasonal Performance Factor

SEER - Seasonal Energy Efficiency Ratio

Detailed Cooling Capacities

This section provides detailed cooling capacity data for various unit configurations under different indoor and outdoor air conditions.

CFM EWB °F (°C) 75 (23.9) 85 (29.4) 95 (35) 105 (40.6) 115 (46.1) 125 (51.7)
Capacity MBtuh Total Sens‡ Total Syst. KW** Capacity MBtuh Total Sens‡ Total Syst. KW** Capacity MBtuh Total Sens‡ Total Syst. KW** Capacity MBtuh Total Sens‡ Total Syst. KW** Capacity MBtuh Total Sens‡ Total Syst. KW** Capacity MBtuh Total Sens‡ Total Syst. KW**
25HCE418 ---30 Outdoor Section With FB4CNP018L Indoor Section
525 72 (22.2) 21.99 11.23 1.19 20.64 10.68 1.36 19.27 10.11 1.54 17.87 9.55 1.75 16.42 8.98 1.98 14.95 8.40 2.24
67 (19.4) 19.94 13.74 1.18 18.72 13.15 1.35 17.47 12.55 1.53 16.18 11.95 1.74 14.86 11.33 1.97 13.51 10.71 2.22
63 (17.2)†† 18.46 13.21 1.18 17.33 12.63 1.35 16.16 12.04 1.53 14.96 11.44 1.73 13.73 10.83 1.96 12.47 10.21 2.22
62 (16.7) 18.10 16.18 1.18 17.00 15.54 1.34 15.88 14.89 1.53 14.73 14.19 1.73 13.63 13.63 1.96 12.59 12.59 2.22
57 (13.9) 17.41 17.41 1.18 16.52 16.52 1.34 15.58 15.58 1.52 14.62 14.62 1.73 13.61 13.61 1.96 12.57 12.57 2.22
600 72 (22.2) 22.45 11.80 1.20 21.05 11.23 1.37 19.62 10.65 1.56 18.16 10.07 1.76 16.67 9.49 1.99 15.15 8.90 2.25
67 (19.4) 20.38 14.65 1.20 19.11 14.03 1.37 17.80 13.41 1.55 16.47 12.79 1.75 15.10 12.15 1.98 13.71 11.50 2.24
63 (17.2)†† 18.88 14.06 1.19 17.70 13.45 1.36 16.49 12.84 1.54 15.24 12.21 1.75 13.97 11.58 1.98 12.67 10.94 2.23
62 (16.7) 18.56 17.37 1.19 17.43 16.67 1.36 16.27 16.27 1.54 15.23 14.16 1.75 14.16 14.16 1.98 13.06 13.06 2.23
57 (13.9) 18.19 18.19 1.19 17.23 17.23 1.36 16.24 16.24 1.54 15.21 15.21 1.75 14.14 14.14 1.98 13.04 13.04 2.23
675 72 (22.2) 22.80 12.34 1.22 21.36 11.75 1.39 19.88 11.16 1.57 18.39 10.57 1.78 16.86 9.97 2.01 15.30 9.37 2.27
67 (19.4) 20.71 15.51 1.21 19.40 14.88 1.38 18.06 14.23 1.56 16.69 13.58 1.76 15.29 12.92 2.00 13.87 12.24 2.25
63 (17.2)†† 19.20 14.86 1.21 17.98 14.23 1.37 16.74 13.60 1.56 15.46 12.95 1.76 14.15 12.29 1.99 12.83 11.62 2.25
62 (16.7) 18.96 18.41 1.21 17.86 17.86 1.37 16.80 16.80 1.56 15.72 15.72 1.76 14.60 14.60 1.99 13.44 13.44 2.25
57 (13.9) 18.84 18.84 1.21 17.83 17.83 1.37 16.78 16.78 1.56 15.70 15.70 1.76 14.58 14.58 1.99 13.42 13.42 2.25
700 72 (22.2) 27.88 14.26 1.36 25.95 13.50 1.61 24.01 12.73 1.91 22.05 11.96 2.25 20.07 11.19 2.66 18.05 10.40 3.12
67 (19.4) 25.38 17.64 1.37 23.61 16.80 1.62 21.83 15.96 1.91 20.05 15.11 2.26 18.22 14.25 2.66 16.40 13.38 3.12
63 (17.2)†† 23.55 16.97 1.37 21.91 16.14 1.62 20.26 15.30 1.92 18.58 14.46 2.26 16.90 13.62 2.66 15.50 10.97 3.05
62 (16.7) 23.71 18.90 1.39 21.59 19.96 1.62 20.00 18.99 1.92 18.55 17.64 2.26 16.97 16.97 2.66 15.48 15.48 3.13
57 (13.9) 22.57 22.57 1.38 21.19 21.19 1.63 19.80 19.80 1.92 18.39 18.39 2.26 16.94 16.94 2.66 15.46 15.46 3.13
800 72 (22.2) 28.38 14.99 1.38 26.39 14.20 1.63 24.38 13.41 1.92 22.36 12.61 2.27 20.33 11.82 2.67 18.26 11.02 3.14
67 (19.4) 25.85 18.82 1.38 24.03 17.94 1.64 22.20 17.06 1.93 20.35 16.17 2.28 18.49 15.28 2.68 16.61 14.36 3.14
63 (17.2)†† 24.02 18.06 1.39 22.32 17.20 1.64 20.62 16.33 1.94 18.90 15.45 2.28 17.16 14.57 2.68 15.41 13.66 3.15
62 (16.7) 23.75 22.40 1.39 22.17 21.26 1.64 20.60 20.60 1.93 19.10 19.10 2.28 17.57 17.57 2.68 16.00 16.00 3.15
57 (13.9) 23.50 23.50 1.39 22.04 22.04 1.64 20.57 20.57 1.93 19.07 19.07 2.28 17.55 17.55 2.68 15.46 15.46 3.15
900 72 (22.2) 28.76 15.68 1.39 26.71 14.88 1.64 24.66 14.06 1.94 22.59 13.25 2.29 20.51 12.43 2.69 18.41 11.61 3.16
67 (19.4) 26.21 19.94 1.40 24.35 19.02 1.65 22.47 18.11 1.95 20.59 17.18 2.29 18.69 16.24 2.70 16.79 15.27 3.16
63 (17.2)†† 24.38 19.10 1.40 22.64 18.20 1.66 20.89 17.30 1.95 19.14 16.39 2.30 17.37 15.45 2.70 15.59 14.49 3.17
62 (16.7) 24.53 22.87 1.40 23.10 20.91 1.66 21.23 21.23 1.95 19.66 19.66 2.30 18.06 18.06 2.70 16.43 16.43 3.17
57 (13.9) 24.27 24.27 1.40 22.74 22.74 1.66 21.20 21.20 1.95 19.63 19.63 2.30 18.04 18.04 2.70 16.41 16.41 3.17
875 72 (22.2) 34.32 17.82 1.83 32.63 17.00 2.11 30.87 16.16 2.45 29.00 15.31 2.83 27.02 14.44 3.29 24.90 13.54 3.82
67 (19.4) 31.12 21.91 1.83 29.57 21.02 2.11 27.96 20.13 2.45 26.25 19.22 2.83 24.44 18.28 3.29 22.51 17.31 3.82
63 (17.2)†† 28.80 21.05 1.83 27.36 20.17 2.12 25.86 19.29 2.45 24.27 18.39 2.83 22.59 17.46 3.29 20.79 16.50 3.82
62 (16.7) 28.27 25.88 1.83 26.88 24.90 2.12 25.44 23.90 2.45 23.95 22.83 2.83 22.44 22.44 3.29 20.97 20.97 3.82
57 (13.9) 27.33 27.33 1.83 26.19 26.19 2.12 25.01 25.01 2.45 23.76 23.76 2.83 22.41 22.41 3.28 20.95 20.95 3.82
1050 72 (22.2) 35.21 19.02 1.86 33.42 18.16 2.15 31.57 17.30 2.49 29.61 16.42 2.88 27.53 15.51 3.33 25.31 14.58 3.87
67 (19.4) 31.94 23.85 1.87 30.30 22.92 2.15 28.60 21.97 2.49 26.81 21.01 2.88 24.92 20.01 3.33 22.91 18.98 3.86
63 (17.2)†† 29.58 22.85 1.87 28.06 21.93 2.15 26.47 21.00 2.49 24.81 20.04 2.88 23.05 19.06 3.33 21.19 18.04 3.87
62 (16.7) 29.18 28.33 1.87 27.76 27.51 2.15 26.36 26.36 2.49 24.99 24.99 2.87 23.53 23.53 3.33 21.94 21.94 3.86
57 (13.9) 28.84 28.84 1.87 27.62 27.62 2.15 26.33 26.33 2.49 24.96 24.96 2.87 23.50 23.50 3.33 21.91 21.91 3.87
1125 72 (22.2) 35.51 19.52 1.88 33.70 18.65 2.17 31.81 17.78 2.50 29.81 16.88 2.89 27.70 15.96 3.35 25.45 15.02 3.89
67 (19.4) 32.22 24.66 1.88 30.55 23.70 2.17 28.82 22.74 2.50 27.00 21.75 2.89 25.08 20.73 3.35 23.05 19.66 3.88
63 (17.2)†† 29.85 23.60 1.88 28.30 22.66 2.17 26.69 21.71 2.51 24.99 20.73 2.89 23.21 19.71 3.35 21.33 18.66 3.88
62 (16.7) 29.48 29.48 1.88 28.16 28.16 2.17 26.83 26.83 2.51 25.42 25.42 2.89 23.91 23.91 3.35 22.28 22.28 3.88
57 (13.9) 29.40 29.40 1.88 28.13 28.13 2.17 26.80 26.80 2.51 25.39 25.39 2.89 23.88 23.88 3.35 22.25 22.25 3.89
1350 72 (22.2) 41.05 21.62 2.40 39.08 20.92 2.67 37.03 20.21 2.95 34.89 19.47 3.26 32.64 18.70 3.58 30.29 17.91 3.93
67 (19.4) 37.13 27.29 2.36 35.32 26.58 2.64 33.44 25.84 2.92 31.48 25.07 3.22 29.43 24.25 3.55 27.31 23.39 3.90
63 (17.2)†† 34.94 27.70 2.34 32.87 26.63 2.61 30.80 25.58 2.89 28.69 24.49 3.18 26.47 23.37 3.53 24.16 22.17 3.88
62 (16.7) 34.52 34.22 2.34 32.84 32.10 2.61 30.87 30.87 2.89 29.10 29.10 3.21 27.23 27.23 3.59 25.22 25.22 3.89
57 (13.9) 34.18 34.18 2.33 32.52 32.52 2.60 30.83 30.83 2.89 29.07 29.07 3.21 27.20 27.20 3.59 25.20 25.20 3.89

See notes on page 15.

Heat Pump Heating Performance

This section details the heating performance of the heat pump units under various indoor and outdoor air temperature conditions.

INDOOR AIR OUTDOOR COIL ENTERING AIR TEMPERATURES ° F (° C)
EDB CFM -3 (19.4) 7 (-13.9) 17 (-8.3) 27 (-2.i8) 37 (2.8) 47 (8.3) 57 (13.9) 67 (19.4)
Capacity MBtuh Total Integ* Total Syst. KW{ Capacity MBtuh Total Integ* Total Syst. KW{ Capacity MBtuh Total Integ* Total Syst. KW{ Capacity MBtuh Total Integ* Total Syst. KW{ Capacity MBtuh Total Integ* Total Syst. KW{ Capacity MBtuh Total Integ* Total Syst. KW{ Capacity MBtuh Total Integ* Total Syst. KW{ Capacity MBtuh Total Integ* Total Syst. KW{
25HCE418 ---30 Outdoor Section With FB4CNP018L Indoor Section
65 (18.3) 525 5.99 5.51 1.15 8.26 7.59 1.19 10.57 9.64 1.22 13.16 11.68 1.26 15.35 13.97 1.30 17.67 17.67 1.35 20.14 20.14 1.42 22.47 22.47 1.47
600 6.10 5.62 1.15 8.39 7.71 1.18 10.74 9.79 1.21 13.32 11.83 1.25 15.55 14.15 1.28 17.93 17.93 1.32 20.47 20.47 1.38 22.59 22.59 1.42
675 6.20 5.70 1.16 8.49 7.80 1.18 10.89 9.93 1.21 13.46 11.95 1.24 15.72 14.30 1.26 18.12 18.12 1.30 20.66 20.66 1.34 22.59 22.59 1.38
70 (21.1) 525 5.67 5.22 1.20 7.93 7.28 1.24 10.23 9.33 1.28 12.87 11.43 1.33 15.06 13.70 1.37 17.34 17.34 1.42 19.76 19.76 1.49 22.14 22.14 1.55
600 5.78 5.32 1.20 8.06 7.41 1.24 10.40 9.48 1.27 13.05 11.59 1.31 15.26 13.88 1.34 17.60 17.60 1.39 20.09 20.09 1.45 22.30 22.30 1.49
675 5.87 5.40 1.21 8.18 7.51 1.24 10.54 9.61 1.27 13.19 11.72 1.30 15.43 14.04 1.32 17.81 17.81 1.37 20.33 20.33 1.41 22.33 22.33 1.45
75 (23.9) 525 5.29 4.87 1.25 7.57 6.95 1.30 9.87 9.00 1.34 12.57 11.16 1.39 14.77 13.44 1.43 17.02 17.02 1.49 19.39 19.39 1.56 21.80 21.80 1.62
600 5.40 4.97 1.26 7.70 7.08 1.29 10.04 9.16 1.33 12.75 11.32 1.37 14.97 13.62 1.41 17.27 17.27 1.45 19.70 19.70 1.52 21.99 21.99 1.56
675 5.51 5.07 1.27 7.82 7.19 1.30 10.18 9.28 1.33 12.90 11.46 1.36 15.14 13.78 1.39 17.47 17.47 1.43 19.96 19.96 1.49 22.06 22.06 1.52
25HCE424 ---30 Outdoor Section With FB4CNP030L Indoor Section
700 65 (18.3) 8.29 7.62 1.37 10.72 9.85 1.41 13.41 12.23 1.46 16.45 14.61 1.53 19.28 17.54 1.58 22.32 22.32 1.65 25.61 25.61 1.71 28.37 28.37 1.77
70 (21.1) 7.86 7.23 1.42 10.31 9.48 1.47 13.00 11.86 1.53 16.17 14.36 1.60 18.96 17.25 1.66 21.92 21.92 1.73 25.22 25.22 1.80 28.24 28.24 1.86
75 (23.9) 7.43 6.84 1.48 9.90 9.10 1.54 12.60 11.49 1.60 15.87 14.10 1.68 18.65 16.97 1.74 21.63 21.63 1.81 24.81 24.81 1.88 27.89 27.89 1.95
800 65 (18.3) 8.42 7.75 1.37 10.88 10.00 1.42 13.64 12.43 1.46 16.64 14.77 1.51 19.50 17.74 1.56 22.57 22.57 1.62 25.83 25.83 1.67 28.66 28.66 1.72
70 (21.1) 8.00 7.36 1.43 10.47 9.62 1.48 13.20 12.04 1.52 16.35 14.52 1.58 19.18 17.46 1.64 22.20 22.20 1.69 25.48 25.48 1.75 28.34 28.34 1.81
75 (23.9) 7.56 6.96 1.49 10.06 9.25 1.54 12.79 11.66 1.59 16.06 14.27 1.66 18.86 17.16 1.71 21.87 21.87 1.78 25.11 25.11 1.84 28.00 28.00 1.90
900 65 (18.3) 8.54 7.86 1.38 11.02 10.13 1.42 13.81 12.59 1.46 16.80 14.92 1.50 19.69 17.92 1.55 22.80 22.80 1.60 25.95 25.95 1.64 28.64 28.64 1.69
70 (21.1) 8.12 7.47 1.44 10.62 9.76 1.48 13.36 12.18 1.52 16.50 14.65 1.58 19.36 17.62 1.62 22.42 22.42 1.67 25.64 25.64 1.72 28.35 28.35 1.77
75 (23.9) 7.68 7.07 1.50 10.20 9.37 1.54 12.95 11.80 1.59 16.22 14.40 1.65 19.04 17.32 1.70 22.06 22.06 1.76 25.29 25.29 1.81 28.05 28.05 1.86
875 65 (18.3) 10.53 9.68 1.83 13.53 12.44 1.89 17.14 15.63 1.97 20.47 18.18 2.05 24.29 22.11 2.15 28.57 28.57 2.26 33.43 33.43 2.39 37.94 37.94 2.49
70 (21.1) 10.06 9.26 1.90 13.08 12.02 1.97 16.80 15.32 2.06 20.12 17.87 2.14 23.88 21.73 2.24 28.09 28.09 2.35 32.89 32.89 2.49 37.51 37.51 2.60
75 (23.9) 9.59 8.82 1.98 12.62 11.60 2.05 16.06 14.65 2.13 19.77 17.56 2.23 23.47 21.36 2.33 27.62 27.62 2.45 32.35 32.35 2.59 37.03 37.03 2.71
1050 65 (18.3) 12.69 11.67 2.19 16.96 15.58 2.31 21.07 19.21 2.39 25.72 22.84 2.49 29.58 26.91 2.56 33.94 33.94 2.65 38.88 38.88 2.79 45.00 45.00 3.00
70 (21.1) 11.93 10.97 2.28 16.33 15.00 2.39 20.46 18.65 2.47 24.66 21.90 2.54 28.75 26.16 2.62 33.35 33.35 2.77 38.21 38.21 2.90 44.19 44.19 3.11
75 (23.9) 11.21 10.32 2.37 15.66 14.39 2.49 19.83 17.89 2.57 23.72 21.07 2.64 28.24 25.70 2.73 32.01 32.01 2.81 36.11 36.11 2.91 41.21 41.21 3.05
1200 65 (18.3) 13.11 12.06 2.21 17.18 15.79 2.30 21.15 19.29 2.37 25.69 22.82 2.46 29.27 26.63 2.51 33.08 33.08 2.57 37.32 37.32 2.68 42.38 42.38 2.84
70 (21.1) 12.29 11.30 2.29 16.40 15.07 2.39 20.41 18.61 2.47 24.66 21.90 2.54 28.75 26.16 2.62 32.54 32.54 2.69 36.71 36.71 2.79 41.68 41.68 2.95
75 (23.9) 11.40 10.49 2.38 15.58 14.32 2.49 19.62 17.89 2.57 23.72 21.07 2.64 28.24 25.70 2.73 32.01 32.01 2.81 36.11 36.11 2.91 41.21 41.21 3.05
1350 65 (18.3) 13.41 12.34 2.24 17.53 16.11 2.32 21.55 19.65 2.38 26.06 23.15 2.45 29.69 27.02 2.49 33.56 33.56 2.55 37.91 37.91 2.64 43.09 43.09 2.79
70 (21.1) 12.58 11.57 2.32 16.74 15.39 2.41 20.80 18.96 2.48 25.50 22.65 2.56 29.15 26.52 2.60 33.00 33.00 2.66 37.27 37.27 2.75 42.36 42.36 2.90
75 (23.9) 11.69 10.75 2.41 15.90 14.61 2.51 20.02 18.25 2.58 24.19 21.48 2.64 28.63 26.05 2.71 32.46 32.46 2.77 36.65 36.65 2.87 41.64 41.64 3.02

Guide Specifications

GENERAL

System Description

Outdoor-mounted, air-cooled, split-system heat pump unit suitable for ground or rooftop installation. Unit consists of a hermetic compressor, an air-cooled coil, propeller-type condenser fan, and a control box. Unit will discharge supply air upward as shown on contract drawings. Unit will be used in a refrigeration circuit to match up to a packaged fan coil or coil unit.

Quality Assurance

Delivery, Storage, and Handling

Warranty (for inclusion by specifying engineer)

PRODUCTS

Equipment

Unit Cabinet

Fans

Compressor

Condenser Coil

Refrigeration Components

Operating Characteristics

The capacity of the unit will meet or exceed _____ Btuh at a suction temperature of _____ °F/°C. The power consumption at full load will not exceed _____ kW.

Combination of the unit and the evaporator or fan coil unit will have a total net cooling capacity of _____ Btuh or greater at conditions of _____ CFM entering air temperature at the evaporator at _____ °F wet bulb and _____ °F/°C dry bulb, and air entering the unit at _____ °F/°C.

The system will have a SEER of _____ Btuh/watt or greater at DOE conditions.

Electrical Requirements

Nominal unit electrical characteristics will be _____ v, single phase, 60 hz. The unit will be capable of satisfactory operation within voltage limits of _____ v to _____ v.

Special Features

Refer to section of this literature identifying accessories and descriptions for specific features and available enhancements.

System Design Summary

  1. Intended for outdoor installation with free air inlet and outlet. Outdoor fan external static pressure available is less than 0.01-in. wc.
  2. Minimum outdoor operating air temperature without low-ambient operation accessory is 55°F (12.8°C).
  3. Maximum outdoor operating air temperature for cooling mode is 125°F (51.7°C).
  4. Minimum outdoor operating air temperature for heating mode is –10°F (–23.3°C).
  5. Maximum outdoor operating air temperature for heating mode is 66°F (18.9°C).
  6. For reliable operation, unit should be level in all horizontal planes.
  7. For interconnecting refrigerant tube lengths greater than 80 ft (23.4 m) and/or elevation differences between indoor and outdoor units greater than 20 ft (6.1 m), consult Residential Piping and Longline Guideline and Service Manual available from equipment distributor.
  8. If any refrigerant tubing is buried, provide a 6 in. (152.4 mm) vertical rise to the valve connections at the unit. Refrigerant tubing lengths up to 36 in. (914.4 mm) may be buried without further consideration. Do not bury refrigerant lines longer than 36 in. (914.4 mm).
  9. Use only copper wire for electric connection at unit. Aluminum and clad aluminum are not acceptable for the type of connector provided.
  10. Do not apply capillary tube indoor coils to these units.
  11. Factory-supplied filter drier must be installed.

PDF preview unavailable. Download the PDF instead.

25HCE4-08PD Acrobat Distiller 11.0 (Windows)

Related Documents

Preview Carrier GH5S Single-Stage Heat Pump Product Data & Specifications
Comprehensive product data, features, specifications, and installation guidelines for the Carrier GH5S Single-Stage Heat Pump, designed with Puron® refrigerant for 1-1/2 to 5 tons applications.
Preview Carrier 25HNB6 Infinity 2-Stage Heat Pump with Puron Refrigerant
Detailed product data and specifications for the Carrier 25HNB6 Infinity 2-Stage Heat Pump, featuring Puron refrigerant and 2 to 5 nominal tons capacity. Includes information on energy efficiency, sound levels, reliability, durability, controls, and applications.
Preview Carrier 48SD/48SDN Single-Packaged Gas Heating/Electric Cooling Units - Product Data
Comprehensive product data for Carrier's 48SD/48SDN series of single-packaged gas heating and electric cooling units. This document details features, benefits, specifications, performance data, installation guidelines, electrical information, and options for residential and light commercial applications.
Preview Carrier GA4S Single-Stage Air Conditioner Product Data and Specifications
Explore the Carrier GA4S single-stage air conditioner, featuring Puron® refrigerant, SEER2 ratings from 13.4 to 16.0, and capacities from 1-1/2 to 5 tons. This document provides detailed product data, specifications, and performance ratings.
Preview Carrier 25HBC5 Heat Pump Product Data
Comprehensive product data for the Carrier 25HBC5 series heat pumps, detailing features, specifications, performance ratings, and accessories for efficient heating and cooling.
Preview Carrier 26SCA4 Comfort™ Series Air Conditioner Product Data
Detailed specifications, features, benefits, model nomenclature, electrical data, and application guidelines for the Carrier 26SCA4 Comfort™ Series single-stage air conditioner, featuring Puron Advance™ refrigerant (1.5 to 5 Tons).
Preview Carrier 26SCA5 Comfort™ Series Air Conditioner Product Data
Explore the Carrier 26SCA5 Comfort™ Series Single-Stage Air Conditioner, featuring Puron Advance™ Refrigerant. This document provides detailed product data, features, benefits, specifications, and performance ratings for various models.
Preview Carrier 50EZ-A and 50VT-A Heat Pump Owner's Information Manual
Owner's information manual for Carrier Comfort and Performance 13 and 14 SEER Single Packaged Heat Pump Systems (50EZ-A and 50VT-A) with Puron refrigerant. Covers operation, safety, maintenance, and troubleshooting.