AC110-220V 10A STC-3028 Dual LED Temperature Humidity Control Thermostat+Probe
Description
- Power supply: AC 110-220V, 50/60Hz
- Measurement temperature range: -20 °C ~ +80 °C
- Measuring humidity range: 00%RH ~ +100%RH
- Accuracy: ±1°C, 0.1%RH
- Relay output contact capacity: 10A
- Integrated sensor, line length 1 meter
- Shell material: Gray ABS flame retardant plastic shell
- Net weight: 120g, Gross weight: 140g
Specifications and Size
Front panel size: 75(L) x 34.5(W) mm
Mounting size: 71(L) x 29(W) mm
Product size: 75(L) x 34.5(W) x 85(D) mm
Sensor length: 1m (includes the probe)
The device features a dual LED display showing current temperature and humidity. It has control buttons for adjustment and setting.
Wiring Diagram and Connections
The STC-3028 controller has a terminal block for connections:
- Terminals 1-2: Power Supply (Supports 110V/AC220V, 12V, 24V options)
- Terminals 3-4: Humidity sensor connection
- Terminals 5-6: Relay output for Heating (10A/220VAC)
- Terminals 7-8: Relay output for Cooling (10A/220VAC)
Important Notes for Wiring:
- Strictly distinguish the interface of relay, sensor, and power supply.
- Ensure correct connection of sensor and power.
- Keep the sensor down-lead and power wire at a proper distance to avoid interference.
Application Examples
This thermostat is suitable for various applications requiring temperature and humidity control, including:
- Refrigerators
- Fans
- Water heaters
- Other environmental control systems
Temperature and Humidity Settings
Temperature Setting:
- To set the starting temperature: Long press the [up-arrow] button for 3 seconds. The value flashes (default 20°C). Use the [up-arrow] or [down-arrow] buttons to adjust. Long press the [up-arrow] button again for 3 seconds to stop flashing (default 30°C). Use the [up-arrow] or [down-arrow] buttons to adjust.
- To set the stop temperature: Long press the [down-arrow] button for 3 seconds. The value flashes (default 40°C). Use the [up-arrow] or [down-arrow] buttons to adjust. Long press the [down-arrow] button again for 3 seconds to stop flashing (default 60°C). Use the [up-arrow] or [down-arrow] buttons to adjust.
- Pressing the [down-arrow] button for 3 seconds resets the factory settings.
The device supports Heating mode (setting start/stop temperatures) and Cooling mode (setting start/stop temperatures).
Humidity Setting:
- To set the starting humidity: Long press the [up-arrow] button for 3 seconds. The value flashes (default 45.0%RH). Use the [up-arrow] or [down-arrow] buttons to adjust. Long press the [up-arrow] button again for 3 seconds to stop flashing (default 50.0%RH). Use the [up-arrow] or [down-arrow] buttons to adjust.
- To set the stop humidity: Long press the [down-arrow] button for 3 seconds. The value flashes (default 80.0%RH). Use the [up-arrow] or [down-arrow] buttons to adjust. Long press the [down-arrow] button again for 3 seconds to stop flashing (default 80.0%RH). Use the [up-arrow] or [down-arrow] buttons to adjust.
The device supports Humidity mode (setting start/stop humidity) and Dehumidification mode (setting start/stop humidity).
Calibration
Temperature Calibration: Simultaneously press the [up-arrow] and [down-arrow] buttons to access the temperature calibration setting (default 0.0°C). Adjust the flashing value by 0.1 using the [up-arrow] and [down-arrow] arrows.
Humidity Calibration: Simultaneously press the [up-arrow] and [down-arrow] buttons to access the relative humidity calibration setting (default 0.0% RH). Adjust the flashing value by 0.1 using the [up-arrow] and [down-arrow] arrows.