Outdoor SPA
Installation & Usage Manual
Menu
- Description on Computer Control System
- MX-(01,02,03,04)-CH(1,2)FM
- Declaration for Electrical Equipment
- Description of Installation & Maintenance
- Using Maintaining For SPA
- Instructions on Repairing
- Troubleshooting
- Warning
Description on Computer Control System
The control system features the following functions:
- On and off key: Press to control the on and off of the control system.
- Pump 1: Press to turn on/off single-speed pump 1. For double-speed pumps, press to switch between low speed, high speed, and off. Pump 1 turns off automatically after a set period.
- Pump 2: Press to turn on/off pump 2. Pump 2 turns off automatically after 30 minutes.
- Blower: Press to turn on/off the blower. The blower turns off automatically after 30 minutes.
- Lamp: Press to control the lamp. Press for 2 seconds to turn off quickly. The lamp turns off automatically after 2 hours. The lamp has two modes: on/off and RGB mode with 9 states (automatic color change, red, green, yellow, blue, purple, cyan, white, turning off).
- Timing water cycle: Allows setting two time ranges for water cycle. The function starts within the set time ranges.
- Ozone: The ozone generator activates automatically when the heating cycle pump or timing water cycle is turned on, provided pumps and blowers are off. It turns off when all other functions are off.
- Heating: Allows setting two time ranges for heating. The heating function starts within the set time ranges, with the heater activating shortly after the heating cycle pump.
- Freeze proof: If the water temperature drops below 6°C (43°F), the heating function starts. It turns off when the temperature reaches 10°C (50°F).
Setting
- Temperature unit: Press the SET button for 8 seconds within 5 minutes of powering on to change the temperature unit. A buzzer will indicate the change.
- Temperature setting: Press SET until the temperature unit flashes. Use the left and right arrow buttons to adjust the temperature between 10-40°C (50-104°F). Alternatively, when the system is not in setting mode, use the arrow buttons directly to adjust.
- Clock setting: Press SET until the hour value flashes. Use the arrow buttons to adjust the hour. Press SET again until the minute value flashes. Use the arrow buttons to adjust the minute.
- Timing heating time range: Set start and end times for two heating time ranges using the SET and arrow buttons. The system saves the settings automatically.
- Timing water cycle time range setting: Set start and end times for two water cycle time ranges using the SET and arrow buttons. The system saves the settings automatically.
System Fault Table
Malfunction Code | Malfunction Description | Handle Method |
---|---|---|
E1 | Temperature sensor malfunction | Check the temperature sensor and its connection. Replace if necessary. |
E2 | Temperature exceeds the normal range | Indicates the sensor is sensing overheating. May occur if the heater starts with no or low water flow. Ensure sufficient water in the tub. Contact service provider if frequent. Pay attention to freeze proof when temperature is too low. |
E4 | Thermostat disconnect | Indicates the heater is overheated. May occur with no or low water flow. Contact service provider if frequent. |
E5 | Panel and control box communication malfunction | Check the cable between the control panel and control box. Replace if necessary. |
Attention
To ensure product function, prolong lifetime, and safety, please read the following items carefully before using:
- Follow wiring diagrams and parameters for load installation.
- Connect ground wiring to normal-running supply circuits.
- Use appropriate power supply cables (3 x 8mm² or wider) and sockets (80A or above).
- Install an 80A or above air-break or leakage switch.
- Check power supply wiring before powering on.
- Do not install equipment from illegal factories.
- Wire power box connections correctly to avoid short-circuits.
- Cut off power after use to prevent aging.
- Controller installation must be done by qualified personnel.
- Do not attempt to repair or modify controller parts; high voltage can be dangerous. All maintenance by qualified personnel.
Declaration for Electrical Equipment
- Maintenance or repairing should be handled by authorized personnel. Otherwise, free maintenance is void.
- This manual is for reference; modifications may occur without notice. Explaining rights belong to the manufacturer.
- Electric parameters: Rated voltage: 220VAC/50Hz (110VAC/60Hz); Isolative resistance: >=200MΩ; Water resistance grade: IPX5; Electric shock resistance: first grade.
Product Specifications Table
Model | Rated Power | Current | Pillow (Each) | Air Bubble (Each) | Water pump (Each) | 0.5HP | 2HP | 3HP | Heater 3KW (Each) | Air Pump (Each) | Filter (Each) | Underwater Lamp (Each) | Ozone 15w (12V/8-15W) | Controller System (Set) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
JY8601 | 17300W/64.3A | 8 | 5 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | ||
JY8602 | 9800W/46.3A | / | 2 | 1 | / | 3 | 1 | 1 | 1 | 1 | 1 | 1 | ||
JY8603 | 9800W/46.3A | / | 2 | 1 | 1 | 2 | 1 | 1 | 1 | 1 | 1 | 1 | ||
JY8001 | 8900W/38.3A | 16 | 8 | 1 | 1 | 2 | 1 | 1 | 1 | 1 | 1 | 1 | ||
JY8002 | 7600W/34A | 10 | 6 | 1 | / | 2 | 1 | 1 | 1 | 1 | 1 | 1 | ||
JY8003 | 7600W/34A | 10 | 3 | 1 | / | 2 | 1 | 1 | 1 | 1 | 1 | 1 | ||
JY8009 | 6000W/27.3A | 14 | 1 | 1 | 1 | / | 1 | 1 | 1 | 1 | 1 | 1 | ||
JY8009 | 5000W/22.73A | / | 1 | / | 1 | / | / | 1 | 1 | 1 | 1 | 1 | ||
JY8010 | 6100W/28.5A | 10 | / | 1 | 1 | / | 1 | 1 | 1 | 1 | 1 | 1 | ||
JY8011 | 7600W/34A | 10 | 3 | 1 | 2 | / | 1 | 1 | 1 | 1 | 1 | 1 | ||
JY8012 | 7600W/34A | 10 | 3 | 1 | 2 | / | 1 | 1 | 1 | 1 | 1 | 1 | ||
JY8012E | 6000W/27.3A | / | 3 | 1 | 1 | / | 1 | 1 | 1 | 1 | 1 | 1 | ||
JY8013 | 6100W/28.5A | 6 | 3 | 1 | / | 1 | 1 | 1 | 1 | 1 | 1 | 1 | ||
JY8015 | 7600W/34A | 10 | 4 | 1 | 2 | / | 1 | 1 | 1 | 1 | 1 | 1 | ||
JY8016 | 7600W/34A | 10 | 3 | 1 | 2 | / | 1 | 1 | 1 | 1 | 1 | 1 | ||
JY8017 | 7600W/34A | 10 | 3 | 1 | 2 | / | 1 | 1 | 1 | 1 | 1 | 1 | ||
JY8018 | 7600W/34A | 10 | 3 | 1 | 2 | / | 1 | 1 | 1 | 1 | 1 | 1 |
Max Output loading indicate: Ozone: AC12V/15W; Radio: Frequency Range: FM: 87.0~108.0MHz; Maximum Output Power: 20W; Speaker: 8Ω damp proof speaker.
Description on Using Parts:
- Thermostat: Materials and structure: AC220-240V, 50/60HZ, 13.6A, 3000W, IPX4; Two sets of thermostats (max constant temperature 40°C-45°C, protection temperature 55-60°C); Pressure switch (water pressure ≥0.035Mpa). Performance Indicate: Power Deviation: Rated Power: 3000W ±5%-10%; Leakage Current under Work State: <0.5mA; Electric Strength under Room Temperature: Basic insulation of electric heating element can bear 1250V test voltage without breakdown for 1min, rated current is 5mA; Electric Strength under Damp State: <0.5mA after dampness test, test voltage is 1.06 times of rated voltage (233.2V). Correctly use: Set temperature not exceeding 40°C. Cautions: Start water pump; ensure no water leakage. Assure thermostat is installed at the positive pressure end of the water pump; dynamic pressure must exceed 0.035MPa. Power supply for thermostat: 220V 50/60HZ, max constant temperature 40-45°C, protection temperature 55-60°C. Do not heat in air manually; seek professional help for faults.
- Air pump (optional): Performance: Protection Grade: IPX5, Insulation class: B, Certification: CQC,CE; Air pump noise: ≤72dB with nozzle. Parts and materials: Pump: high temperature resistant engineering plastic; Carbon brush: imported materials. Correctly use: Normal work time 15-30 minutes; do not exceed 120 minutes continuously to avoid damage.
- Massage Water Pump and Circulation Water Pump: Performance: Protection Grade: IPX5; Insulation class: B; Certification: CQC.CE; Parts and materials: high temperature resistant engineering plastic. Correctly use: Water level shall be 1cm higher than the probe.
Description of Installation & Maintenance
Filter Element Daily Washing
Model 1#
- Remove the outer cover of the skimmer.
- Pull out the filtration tuck net.
- Circumvolve and take out the paper core.
- Wash the paper core with water, reset it after cleaning.
Model 2#
- Tear off the package of the paper core and put it inside the filtration bucket.
- Pull out the filtration tuck net.
- Match the paper core correctly inside and screw down it in sequence, then put the cover of filtration bucket on top.
Model 3#
- Use the key to open the service door and turn off the valve of the water pump.
- Turn on the decompressing valve, and turn on the drainage valve of the filter.
- Let the water in the filter drain out.
- Take away the cover of the filter.
- Take out the paper core.
- Clean the paper core with water, and put it inside.
Changed the fragrance species (option/according to system)
Diagram showing Aroma canister cover, Aroma canister, Sealing cover of canister, Aroma canister holder, and steps for changing fragrance.
Air Valve Instruction
Air controls affect jet pressure by adding air. Opening an air valve when the pump is on draws air into the water flow to increase massage strength.
Water Diverter Instruction
Rotating the water diverter redirects massage power to different seats.
Pillow maintenance
Pillows can be removed for cleaning. For fixed pillows, grab the lower edge and pull up. To reset, align inserts and push firmly.
Draining your SPA
Drain the SPA at least every 3 months, or more frequently if used more than three times a week. There are two types of drain valves: side drain valve and corner drain valve.
Model#1 Drainage: 1. Correct side and pull out. 2. Open the cover. 3. Close.
Model#2 Drainage: Turn on.
DISPOSAL OF WATER: Do not drain water onto lawns or plants unless bromine or chlorine has dissipated. Sunlight dissipates sanitizer.
OZONE disinfection: Ozone is an effective disinfectant, leaving no chemical trace and is odorless. The spa is equipped with an ozone generator (50mg/hour). It works automatically when the circulation pump is running. An indicator light shows operation.
Pump Maintenance (Air Locks)
If the pump runs but there is no water movement, an air lock may be present. Turn off the spa, locate the circulation pump, find the pipe entering the top, and undo the barrel union anti-clockwise until air escapes. Retighten when water flows. You may need to restart the pump.
To stop water flow, turn off the valve. Ensure the valve is on for normal operation.
Speaker Model (Option)
- Model 1#: Skirt speakers install on the spa skirt.
- Model 2#: Pop up speakers: press downwards from the top to pop up or close.
DVD and TV instruction & Maintenance
Instructions for connecting DVD with antenna function, including connecting audio-frequency, video frequency, and antenna plugs. A small control panel manages TV up/down functions.
IPOD/IPHONE DOCK: Refer to the user manual for detailed operation.
Spa Cover Instruction (Option)
Each insulation cover has a coded lock. Fix the male part with screws, set the password, and press buckles to open.
Spa Cover Lifter (Option)
Refer to the attachment manual for assembly instructions.
Assembly of Ladder for the spa(option)
The ladder is knocked-down for packing and can be assembled as shown.
LED Lights Maintenance(option)
If LED lights are not working or have incorrect colors, replace them. Follow steps to replace plug-in or buckle-style LED lights.
Electronic control system Installation: (220~240V/50HZ)
Diagram shows wiring connections for speaker, antenna, and electrical cabinets.
Description of SPA Installation
Confirm power supply switch and drainage positions according to the electric box and drainage on different SPA models. Spare wires with 3*6mm² long. Connect the drainage hole with a prepared 1.5-inch soft pipe while draining water.
Using Maintaining For SPA
- Clean the bathtub with neutral detergent and soft fabric. Avoid acetone, ammonia water, and organic solvents. Wipe adhesive stains with soft fabric and gasoline.
- For scratches, grind with 2000# grinding paper with water, then polish with toothpaste and soft fabric.
- Wipe water scale with a light acid detergent (citric acid, vinegar).
- Remove water-return unit and nozzle for cleaning.
- Avoid frequent wiping of gold and chrome-plated parts with organic solvents. Acid glass sealant may damage electroplating.
- Do not use rough tools, chemical solvents, or grain detergent.
- Do not knock or scratch the bathtub. Avoid contact with burning cigarettes or heat sources exceeding 600°C.
- For the water force massage system: fill with 40°C hot water to exceed nozzle surface, add detergent, run for 5 minutes, drain, refill with clear water, run for 3 minutes, drain, and clean. Drain water if not used for over 3 days. Do not add foaming materials or excessive vegetal cosmetics.
- Check leakage protection performance of the leakage switch every 2 months.
- Periodically check power core, switches, and connectors for damage.
- Periodically check water supply and drainage pipes for smooth flow.
- Do not upset or stack products; avoid storage with formate or formaldehyde.
- Handle with care to prevent heavy pressure, mechanical knock, or intensive vibration.
- Drain water if the bathtub will not be used for a long time. Keep the environment dry and ventilated.
- Clean the filter paper core weekly if the SPA is used frequently.
- The heat-preserving cover is foam plate; keep it away from children.
- Maintain water level 1cm higher than the probe.
- Do not start the machine without water or if the water level is below the probe. Do not turn on the underwater lamp without water.
- Lock the repairing door and keep the key safe.
- Cut off power supply before any maintenance.
- After maintenance, test according to normal operation procedures.
- All maintenance and repairing must be undertaken by qualified and professional technicians. Contact the distributor for service.
- Do not use volatile detergents on the acrylic tub to prevent cracking, wrinkles, and aging.
Instructions on Repairing
- Replace massage water pump: Cut off power, drain SPA, remove wires, open side plate, loosen bolts, remove pump. Install new pump, wires, and bolts. Add water, check for leaks, and reinstall side plate.
- Replace filter water pump: Cut off power, drain SPA, turn off valves, remove wires, open side plate, loosen bolts, remove pump. Install new pump, wires, and bolts. Add water, turn on valves, check for leaks, and reinstall side plate.
- Replace thermostat: Cut off power, drain SPA, turn off valves, remove wires, open side plate, loosen bolts, remove thermostat. Install new thermostat, wires, and bolts. Add water, turn on valves, check for leaks, and reinstall side plate.
- Replace filter core: Cut off power, open side plate, turn off valves, loosen bolts, remove filter, clean dirt.
- Anti-frozen of filter: In freezing areas, stop using the filter, remove and clean the core, store in a safe place or move indoors.
Troubleshooting
Faults | Reason | Solution |
---|---|---|
Nozzle doesn't spray water | 1. Power supply issue for water pump. 2. Water pump not started. 3. Massage water pump damaged. |
Check and connect power wire; Check the massage water pump; Replace the massage water pump. |
Underwater lamp doesn't light on | 1. Bulb damaged. 2. Fuse broken. |
Replace the bulb; Replace the fuse. |
Poor filtering effect | 1. Filter water pump not started. 2. Filter not cleaned. 3. Filter water pump damaged. |
Start the filter water pump; Clean the filter; Replace the filter water pump. |
Constant temperature effect is unavailable | 1. Thermostat damaged. 2. Power supply unavailable. 3. Filter jammed. |
Repair or replace the thermostat; Check the power supply; Clean or replace the filter paper core. |
Bathtub is scratched | Grind with 2000# grinding paper with water, then polish with toothpaste and soft fabric. |
Warning: Please read the following instructions before using the above products, it is the assurance for safety for the SPA users.
- Water temperature rises approx. 2°C/hour. Reaching 38°C from 25°C takes about 6 hours (with cover on).
- In cold weather, ensure SPA system preparation to prevent frost. Antifreeze may be used.
- Elderly, pregnant women, children, and individuals with heart disease or high blood pressure should be accompanied by an adult.
- Alcohol, narcotics, or drugs may cause danger.
- Strictly follow safety instructions.
- Ensure water flows smoothly from nozzles to prevent damage.
- Test water temperature before use to prevent scalding.
- Water temperature should not exceed 40°C. A safe range for humans is 30°C-40°C. For 10-15 minute use, lower the temperature. High temperatures are not beneficial for pregnant women. Keep temperature below 38°C for pregnant women.
- Consider the physical properties of any SPA medicine used.
- Do not use the SPA immediately after intensive exercise.
- Consult a doctor if feeling unwell during or after SPA use.
- Do not move or open the filter cover frequently.
- Avoid prolonged exposure to intensive sunlight, which may damage the SPA surface. Cover if necessary.
- Clean the filter paper core weekly if the SPA is used frequently.
- The heat-preserving cover is foam plate; keep it away from children.
- Water level should be 1cm higher than the probe.
- Do not start the machine without sufficient water or if the water level is below the probe. Do not turn on the underwater lamp without water.
- Lock the repairing door and keep the key safe.
- Cut off power supply before any maintenance.
- After maintaining, test according to normal operation procedures.
- All maintenance and repairing must be undertaken by qualified and professional technicians. Contact the distributor for service.
- Do not use volatile detergents on the acrylic tub to prevent cracking, wrinkles, and aging.