Aeotec TriSensor 8 User Guide

This guide provides detailed information on setting up, operating, and troubleshooting the Aeotec TriSensor 8, a Z-Wave Plus device designed for detecting ambient values and movement.

Get to Know Your TriSensor 8

Your TriSensor comes packaged with accessories to aid in its installation and operation.

Package Contents:

  • TriSensor 8
  • Battery Cover
  • Double-Sided Tape
  • Screws (x2)
  • Back Arm Mount
  • Warranty Card
  • Quick Start Guide

Button Functions

The Action button and LED indicator provide feedback on the TriSensor 8's status.

Action / Button PressLED StatusFunction
When batteries are inserted (factory reset)Blinks between rainbow colorsIndicates it is factory reset and ready to be paired.
When batteries are inserted (paired)Blinks Green ?Indicates it is paired to a Z-Wave network.
1x Tap (factory reset)Blinks Red ?Indicates it is factory reset and ready to be paired.
1x Tap (paired)Blinks Green ?Indicates it is paired to a Z-Wave network.
3x Tap (factory reset)Flashes Red ?Enters Z-Wave pair mode, flashes green ? 5 times upon success.
3x Tap (already paired)Flashes Red ?Sends NIF / Excludes device. If the Z-Wave controller is in unpair mode, TriSensor will flash Red ?.
Press and hold [1-2 seconds]No LEDLED will disappear as soon as you release the button.
Press and hold [3 seconds]Blinks Blue ? onceThe TriSensor 8 will immediately send a wakeup report to your Z-Wave Controller to take in any queued Z-Wave commands.
Press and hold [3-11 seconds]No LEDRelease here to cancel Factory Reset.
Press and hold [12+ seconds]Flashes red/green ?? upon release.Factory Reset Complete.

Important Safety Information

Please read this and other device guides carefully. Failure to follow the recommendations set forth by Aeotec Limited may be dangerous or cause a violation of the law. Aeotec, its importers, distributors, and resellers are not responsible for any loss or damage resulting from not following instructions in this guide or other materials.

  • TriSensor 8 is intended for use in dry locations only. Do not use in damp, moist, and/or wet locations.
  • Do not use rechargeable CR123A batteries.
  • Keep product and batteries away from open flames and extreme heat. Avoid direct sunlight or heat exposure.
  • Always remove all batteries from products that are being stored and not used. Batteries may damage the appliance if they leak.
  • Ensure correct polarity when inserting batteries. Improper battery use may damage the product.
  • Contains small parts; keep away from children.

Quick Start

Power Up TriSensor 8

TriSensor 8 is battery-powered. You must power it up before pairing and using it in your Z-Wave network.

  1. Remove the battery cover by sliding the unlock button to the left [left arrow] and then pulling the cover off.
  2. Insert 1x CR123A lithium battery, orienting it according to the diagram inside the sensor. Warning: Not compatible with rechargeable CR123A batteries (3.6V).
  3. You can close the TriSensor 8 by placing the cover back on at an angle. However, it is recommended to wait until after pairing is complete so you can easily access the Action button.

Connect TriSensor to a Hub

Follow these steps to connect your TriSensor 8 to your Z-Wave hub. Refer to specific hub instructions for more detailed guidance.

  1. Aeotec Smart Home Hub / SmartThings:
    • Open the SmartThings app.
    • Tap '+' (at the top right corner).
    • Tap 'Add' (next to Partner devices).
    • Select 'Aeotec' in the catalog.
    • Tap 'Add without QR Code' -> 'Motion Sensor' or 'Multipurpose Sensor' (either will work).
    • Tap the Action button 3 times within 1.5 seconds on your TriSensor 8.
    • Select 'Secure Setup' when prompted.
    • Scan the QR code or choose to enter the 5-digit DSK code.
  2. Home Assistant / Z-WaveJS:
    • Open Home Assistant.
    • Click 'Configuration' (bottom left).
    • Click 'Integrations'.
    • Click 'Configure'.
    • Click 'ADD NODE'.
    • Click 'START INCLUSION'.
    • Tap the TriSensor 8 Action button 3 times within 1.5 seconds to pair it.
  3. Hubitat:
    • Open your Hubitat interface.
    • Click 'Devices'.
    • Click 'Discover Devices'.
    • Click 'Z-Wave'.
    • Click 'Start Z-wave Inclusion'.
    • Tap the TriSensor 8 Action button 3 times within 1.5 seconds to pair it.
  4. SmartStart QR Code Scanning:
    • If your Z-Wave gateway supports SmartStart, scan the QR code on the TriSensor 8 for automatic pairing if your hub supports this feature.
  5. For most other hubs:
    • Set your Z-Wave hub to connect new Z-Wave devices.
    • Tap the TriSensor 8 Action button 3 times within 1.5 seconds.
    • If prompted, scan the QR code or enter the 5-digit DSK code.

Placement Considerations

Proper placement is crucial for optimal motion detection and accurate environmental readings.

Motion Detection Placement:

  • Ceiling Installation: For the most optimal motion detection, install the TriSensor 8 at a height of at least 3 meters (approximately 10 feet) from the floor.
  • Wall Installation: For wall installations, a height of at least 2.5 meters (approximately 8 feet) from the floor is recommended, with the sensor angled downwards at 45 degrees.
  • The motion sensor's longest detection range is oriented towards the side of the battery compartment.
  • Install the TriSensor 8 pointed towards the area with the most foot traffic ?‍♂️.

Environmental Readings Placement:

  • Avoid installing TriSensor 8 in locations near significant environmental changes such as air conditioners, fans, or heaters ??️, as these will greatly impact temperature sensor accuracy.
  • Install the TriSensor 8 on the opposite side of the room from such environmental changes if you wish to get the most accurate temperature reading for the overall room.
  • Ensure that there are no objects or obstacles ? in front of the sensor lens that can impact motion sensor tracking.
  • Avoid installing TriSensor 8 near any metal ?, as metal reflects wireless signals and can significantly impact the sensor's range.

Z-Wave Resetting TriSensor 8

Your TriSensor 8 can be removed from your Z-Wave network at any time using your Z-Wave network's main controller. Refer to your controller's manual for specific instructions on removing devices.

Using an Existing Gateway:

You may need to refer to your gateway's method of including devices if you do not know how to pair a Z-Wave device. Any gateway can be used to perform an unpair/removal, even if it's not the one the TriSensor 8 is currently paired to, to factory reset the device.

  1. Set your Z-Wave gateway into Z-Wave unpair (exclusion) mode.
  2. Tap the Action button 3 times within 1.5 seconds; the red LED indicator will light up ?.

Manual Hard Resetting TriSensor 8:

This method is not fully advised unless your gateway has failed. Performing these steps will factory reset your TriSensor 8 if it is paired to your network.

  1. Ensure the device is powered.
  2. Press and hold the Action button for 12+ seconds, then release it.
  3. If the reset was successful, the LED will flash red/green quickly ?? to indicate it has been factory reset.

Waking Up TriSensor 8

To configure TriSensor 8, you must wake it up using the button press function. This allows manual wake-up if you don't want to wait for the automatic cycle.

Typically, the TriSensor 8 wakes up automatically using the Wakeup command class, with a default timeframe of once every 43200 seconds (12 hours).

Quick Wakeup:

  1. Press and hold the TriSensor 8 Action button for 3 seconds.
  2. Wait until the LED flashes blue ?.
  3. Release the TriSensor 8 Action button. Any queued commands in your Z-Wave Controller will be sent.

Advanced Settings of TriSensor 8

Further advanced parameter settings and group association settings are available beyond what is detailed in this guide. An advanced engineering sheet for the TriSensor 8 provides all possible functions, including:

  • Parameter settings (Configuration Command Class)
  • Group Association (Association Command Class)

You may download the engineering sheet from the Aeotec website.

PDF preview unavailable. Download the PDF instead.

Aeotec ZWA045 TriSensor 8 Multi-Sensor User Manual Mozilla/5.0 (Windows NT 10.0; Win64; x64) AppleWebKit/537.36 (KHTML, like Gecko) Chrome/124.0.0.0 Safari/537.36 Skia/PDF m124

Related Documents

Preview Aeotec TriSensor 8 (ZWA045) User Manual - Smart Home Sensor
User manual for the Aeotec TriSensor 8 (ZWA045), a Z-Wave Plus smart home sensor with temperature, light, and motion detection. Learn about its features, specifications, and Z-Wave network integration.
Preview Aeotec TriSensor 8: Z-Wave Plus Multi-Sensor Manual and Configuration Guide
Comprehensive guide to the Aeotec TriSensor 8, a Z-Wave Plus multi-sensor detecting motion, temperature, and light. Includes quickstart, installation, safety, inclusion/exclusion, product usage, troubleshooting, association, configuration parameters, and technical data.
Preview Aeotec TriSensor ZWA005 User Manual and Specifications
Comprehensive guide to installing, configuring, and using the Aeotec TriSensor ZWA005 Z-Wave motion, temperature, and light sensor. Includes setup, association, parameter configuration, and safety information.
Preview Aeotec MultiSensor 6 User Guide: Smart Home Z-Wave Sensor
Comprehensive user guide for the Aeotec MultiSensor 6, detailing setup, Z-Wave pairing, installation, advanced functions, and troubleshooting for this smart home sensor.
Preview Aeotec MultiSensor 6 User Guide: Z-Wave Plus Smart Home Sensor
This user guide provides comprehensive instructions for setting up, installing, and using the Aeotec MultiSensor 6, a Z-Wave Plus enabled smart home device that detects motion, temperature, humidity, light, and UV. Learn about its features, safety precautions, pairing with Z-Wave networks, location selection, physical installation, advanced functions, troubleshooting, and firmware updates.
Preview Aeotec MultiSensor Manual: Installation and Operation Guide
Comprehensive guide to installing, configuring, and operating the Aeotec MultiSensor, including Z-Wave network integration, sensor range, and troubleshooting.
Preview Aeotec MultiSensor 7: Comprehensive User Guide for Z-Wave Smart Home Sensor
Learn how to install, configure, and use the Aeotec MultiSensor 7, a Z-Wave 700 series smart home sensor for detecting ambient values and movement. This guide covers package contents, button functions, safety information, quick start, network inclusion, resetting, and advanced settings.
Preview Aeotec Multisensor Z-Wave 4-in-1: Motion, Temperature, Humidity, Light Sensor User Manual
Comprehensive user manual and technical specifications for the Aeotec Multisensor, a versatile Z-Wave 4-in-1 sensor. Learn about its features, installation, Z-Wave pairing, operation, and warranty information.