Aeotec TriSensor 8

SKU: AEOEZWA045

Quickstart

This is a secure Sensor for Europe. To run this device, please insert fresh 1 * CR123A batteries. Please ensure the internal battery is fully charged. If your Z-Wave gateway supports SmartStart, you can scan the QR code on the TriSensor 8 to automatically pair the sensor if your Z-Wave hub supports this.

Important Safety Information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor, and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

What is Z-Wave?

Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section. Z-Wave ensures reliable communication by reconfirming every message (two-way communication), and every mains-powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.

This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin, as long as both are suited for the same frequency range. If a device supports secure communication, it will communicate with other devices securely as long as this device provides the same or a higher level of security. Otherwise, it will automatically turn into a lower level of security to maintain backward compatibility.

For more information about Z-Wave technology, devices, white papers, etc., please refer to www.z-wave.info.

Product Description

Aeotec TriSensor 8 was developed to detect ambient values and movement and to transmit them with Z-Wave Plus. It is powered by Aeotec's Gen8 technology. You can find out more about TriSensor 8 by following that link. To see whether TriSensor 8 is known to be compatible with your Z-Wave system or not, please reference our Z-Wave gateway comparison listing. The technical specifications of TriSensor 8 can be viewed at that link.

Prepare for Installation / Reset

Please read the user manual before installing the product. In order to include (add) a Z-Wave device to a network, it must be in factory default state. Please make sure to reset the device to factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation; however, it is recommended to use the primary controller of the previous network to ensure the device is excluded properly from that network.

Reset to factory default

This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.

  1. Make sure the device has been powered.
  2. Press and hold the button for 12+ seconds, then release the action button.

Safety Warning for Batteries

The product contains batteries. Please remove the batteries when the device is not used. Do not mix batteries of different charging levels or different brands.

Installation

Placement Considerations

There are some placement considerations when using the TriSensor 8 as a motion sensor. The diagrams below show the distance at which wall or ceiling installations can perform based on the height TriSensor 8 is installed, as well as the angle.

Diagram Description:

Ceiling installation should be at least 3m height to the floor for the most optimal motion detection. Wall installation should be at least 2.5m height to the floor, angled downwards at 45 degrees.

Diagram Description (Sensor Layout):

Installation Positioning Advice

Inclusion/Exclusion

On factory default, the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion. Devices can also be removed from a network; this process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion or inclusion mode. Inclusion and Exclusion are then performed by a special manual action on the device.

Inclusion

  1. Set your Z-Wave hub to connect new Z-Wave devices.
  2. Tap the TriSensor 8 action button 3 times within 1.5 seconds.
  3. If prompted, scan the QR code or enter the 5-digit DSK code.

Exclusion

  1. Set your Z-Wave gateway into Z-Wave unpair (exclusion) mode.
  2. Tap the action button 3 times within 1.5 seconds; the red LED will light up.

Product Usage

Power up TriSensor 8

TriSensor 8 can only be battery-powered. You must first power up your TriSensor before you can pair it and use it in your Z-Wave network.

Steps

Diagram Description (Device Components):

  1. Remove the battery cover by sliding the Unlock button LEFT, then pull the cover off.
  2. Insert 1x CR123A lithium batteries, oriented according to the diagram within your sensor. Try inserting the batteries flat rather than at an angle. WARNING: Not compatible with rechargeable CR123A batteries (3.6V).
  3. You can close up the TriSensor 8 by placing the cover back on at an angle, but it is recommended to do this once you are done pairing the sensor to your Z-Wave network. Hold off on doing this so that you can reach the Action button on the TriSensor 8.

Node Information Frame (NIF)

The Node Information Frame (NIF) is the business card of a Z-Wave device. It contains information about the device type and its technical capabilities. The inclusion and exclusion of the device are confirmed by sending out a Node Information Frame. It may also be needed for certain network operations to send out a Node Information Frame. To issue a NIF, execute the following action: Press button 3 times.

Communication to a Sleeping Device (Wakeup)

This device is battery-operated and enters a deep sleep state most of the time to save battery life. Communication with the device is limited. In order to communicate with the device, a static controller C is needed in the network. This controller will maintain a mailbox for the battery-operated devices and store commands that cannot be received during deep sleep state. Without such a controller, communication may become impossible and/or the battery life time is significantly decreased.

This device will wake up regularly and announce its wakeup state by sending out a so-called Wakeup Notification. The controller can then empty the mailbox. Therefore, the device needs to be configured with the desired wakeup interval and the node ID of the controller. If the device was included by a static controller, this controller will usually perform all necessary configurations. The wakeup interval is a tradeoff between maximal battery life time and the desired responses of the device. To wake up the device, please perform the following action: Press and hold the button for 3 seconds.

Quick Troubleshooting

Here are a few hints for network installation if things do not work as expected:

  1. Make sure a device is in a factory reset state before including. In doubt, exclude before including.
  2. If inclusion still fails, check if both devices use the same frequency.
  3. Remove all dead devices from associations. Otherwise, you will see severe delays.
  4. Never use sleeping battery devices without a central controller.
  5. Do not poll FLIRS devices.
  6. Make sure to have enough mains-powered devices to benefit from meshing.

Firmware-Update over the Air (OTA)

This device is capable of receiving new firmware 'over the air'. The update function needs to be supported by the central controller. Once the controller starts the update process, perform the following action to confirm the firmware update: You can find OTA Update by Aeotec.

Association - One Device Controls Another Device

Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g., button pressed, sensor triggers, ...). In case the event happens, all devices stored in the respective association group will receive the same wireless command, typically a 'Basic Set' Command.

Association Groups:

Group Number Maximum Nodes Description
1 5 Lifeline
2 5 Motion (Basic Set)
3 5 Over Heat (Basic Set)
4 5 Under Heat (Basic Set)
5 5 Over light (Basic Set)
6 5 Under Light (Basic Set)
7 5 Temperature (Multisensor)

Configuration Parameters

Z-Wave products are supposed to work out of the box after inclusion; however, certain configurations can adapt the function better to user needs or unlock further enhanced features.

IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128...255, the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200, it may be needed to set a value of 200 minus 256 = minus 56. In case of a two-byte value, the same logic applies: Values greater than 32768 may need to be given as negative values too.

Parameter 3: Motion Untrigger Time

Timeout configuration set in seconds for TriSensor to send no trigger status.

Size: 2 Byte, Default Value: 60

Setting Description
30 - 3600 seconds

Parameter 4: Motion Sensitivity

Set the sensitivity of TriSensor.

Size: 1 Byte, Default Value: 2

Setting Description
0 disable
1 - 3 Sensitivity

Parameter 7: Motion Group Control (Group2)

Set control of other devices on group2 based on motion trigger.

Size: 1 Byte, Default Value: 0

Setting Description
0 Send BASIC_SET (0xFF) when motion is triggered to associated device; Send BASIC_SET (0x00) when motion is untriggered to associated device.
1 Send BASIC_SET (0x00) when motion is triggered; Send BASIC_SET (0xFF) when motion is untriggered.
2 Send BASIC_SET (0xFF) when motion is triggered; Nothing when motion untriggered.
3 Send BASIC_SET (0x00) when motion is triggered; Nothing when motion untriggered.
4 Send BASIC_SET (0x00) when motion is untriggered; Nothing when motion triggered.
5 Send BASIC_SET (0xFF) when motion is untriggered; Nothing when motion triggered.
6 Send BASIC_SET (value is configured by parameter 8) when motion is triggered to associated devices. Send BASIC_SET (value is configured by parameter 8) when motion is untriggered.

Parameter 8: Motion Group Value Setting

Set Basic Set value for Group2. The MSB will act as the basic set value when motion trigger. The LSB will act as the basic set value when motion untrigger. E.g. value=0x0A00, then BASIC_SET(0x0A) will be sent when motion trigger, BASIC_SET(0x00) will be sent when motion untrigger.

Size: 2 Byte, Default Value: 65280

Setting Description
0 - 30000 Value

Parameter 9: Motion Group Control Requirement

Set threshold of Light/Lux when devices associated in group2 should be triggered by motion. Associated device only receive BASIC_SET command when light <= (this value).

Size: 2 Byte, Default Value: 30000

Setting Description
0 - 30000 Value

Parameter 10: Over Heat Group Threshold (Group3)

Set threshold of temperature. Designed to control Air Conditioners or temperature controllers ON or OFF. If measured temperature >= (this value, Scale is determined by Param24) send BASIC_SET (0xFF) to associated devices. If measured temperature < (this value) send BASIC_SET (0x00) to associated devices. E.g. Value 239 means 23.9 °C. Value 750 means 75.0 °F.

Size: 2 Byte, Default Value: 270

Setting Description
270 - 850 °C
806 - 1850 °F

Parameter 11: Under Heat Group Threshold (Group4)

Set threshold of temperature. Designed to control Air Conditioners or temperature controllers ON or OFF. If measured temperature <= (this value, Scale is determined by Param24) send BASIC_SET (0xFF) to associated devices. If measured temperature > (this value) send BASIC_SET (0x00) to associated devices. E.g. Value 155 means 15.5 °C. Value 600 means 60.0 °F.

Size: 2 Byte, Default Value: 155

Setting Description
-100 - 155 °C
140 - 600 °F
0 disable

Parameter 12: Over Light Group Threshold (Group5)

Set threshold of Light/Lux. If measured light/lux >= (this value) send BASIC_SET (0xFF) to associated devices. If measured light < (this value) send BASIC_SET (0x00) to associated devices.

Size: 2 Byte, Default Value: 2000

Setting Description
0 disable
1 - 30000 Lux

Parameter 13: Under Light Group Threshold (Group6)

Set threshold of Light/Lux. If measured light/lux <= (this value) send BASIC_SET (0xFF) to associated devices. If measured light/lux > (this value) send BASIC_SET (0x00) to associated devices.

Size: 2 Byte, Default Value: 100

Setting Description
0 disable
1 - 30000 Lux

Parameter 14: Low Battery Threshold

Configure low battery report threshold; sends low battery report via notification and battery report when battery level drops under setting. Unit %.

Size: 1 Byte, Default Value: 20

Setting Description
10 - 50 %

Parameter 15: Threshold Check Enable/Disable

Size: 1 Byte, Default Value: 0

Setting Description
0 disable
1 enable

Parameter 16: Temperature Threshold

Size: 1 Byte, Default Value: 30

Setting Description
0 disable
1 - 255 Value x 0,1

Parameter 17: Lux Threshold

Size: 2 Byte, Default Value: 250

Setting Description
0 disable
0 - 10000 Lux

Parameter 18: Threshold Check Time

Set threshold check time in seconds.

Size: 2 Byte, Default Value: 900

Setting Description
60 - 65535 Time in seconds

Parameter 19: Sensor Limit Control

This value is a bit mask. Used to enable/disable measurement reports for various sensors that are more than the upper limit value or less than the lower limit value. (1+2=3)

Size: 1 Byte, Default Value: 0

Setting Description
0 Disable
1 Temperature upper level
2 Lux upper level
4 Temperature lower level
8 Lux lower level

Parameter 20: Temperature Upper Limit

Set upper limit level for temperature set in scale of 0.1. Scale is determined by Param23. If (Current measurement) > (Upper Limit), then report sensor.

Size: 2 Byte, Default Value: 280

Setting Description
280 - 1000 °C
824 - 2120 °F

Parameter 21: Temperature Lower Limit

Set lux upper limit level. If (Current measurement) > (Upper Limit), then report sensor.

Size: 2 Byte, Default Value: 0

Setting Description
-400 - 0 °C
-400 - 320 °F

Parameter 22: Lux Upper Limit

Set Lux upper limit level. If (Current measurement) > (Upper Limit), then report sensor.

Size: 2 Byte, Default Value: 1000

Setting Description
0 - 30000 Lux

Parameter 23: Lux lower limit level.

Set Lux lower limit level. If (Current Measurement) < (Lower limit), then report sensor.

Size: 2 Byte, Default Value: 100

Setting Description
0 - 30000 Lux

Parameter 24: Temperature Scale

Set the scale for temperature when reports.

Size: 1 Byte, Default Value: 0

Setting Description
0 °C
1 °F

Parameter 25: Automatic Interval Time

Interval time set in seconds to check the sensor report. Multilevel Sensor Report will be sent when timeout.

Size: 2 Byte, Default Value: 3600

Setting Description
30 - 65535 Time in seconds

Technical Data

Dimensions 0.0450000x0.0450000x0.0400000 mm
Weight 22 gr
Hardware Platform EFR32ZG23
EAN 1220000017276
IP Class IP IP20
Battery Type 1 * CR123A
Device Type Sensor
Firmware Version 02.07
Z-Wave Version 07.12
Certification ID ZC14-24010390
Z-Wave Product Id 0371.0002.002d
Frequency Europe - 868,4 Mhz
Maximum transmission power 5 mW

Supported Command Classes

Explanation of Z-Wave Specific Terms

PDF preview unavailable. Download the PDF instead.

Aeotec-Trisensor-8-manual Mozilla/5.0 (Macintosh; Intel Mac OS X 10 15 7) AppleWebKit/537.36 (KHTML, like Gecko) Chrome/119.0.0.0 Safari/537.36 Skia/PDF m119

Related Documents

Preview Aeotec TriSensor 8 (ZWA045) User Manual - Smart Home Sensor
User manual for the Aeotec TriSensor 8 (ZWA045), a Z-Wave Plus smart home sensor with temperature, light, and motion detection. Learn about its features, specifications, and Z-Wave network integration.
Preview Aeotec TriSensor 8 User Guide: Setup, Features, and Safety
Comprehensive user guide for the Aeotec TriSensor 8, detailing its Z-Wave Plus functionality, installation steps, button operations, safety precautions, and advanced features for smart home automation.
Preview Aeotec MultiSensor 6 User Guide: Smart Home Z-Wave Sensor
Comprehensive user guide for the Aeotec MultiSensor 6, detailing setup, Z-Wave pairing, installation, advanced functions, and troubleshooting for this smart home sensor.
Preview Aeotec TriSensor ZWA005 User Manual and Specifications
Comprehensive guide to installing, configuring, and using the Aeotec TriSensor ZWA005 Z-Wave motion, temperature, and light sensor. Includes setup, association, parameter configuration, and safety information.
Preview Aeotec MultiSensor 7: Comprehensive User Guide for Z-Wave Smart Home Sensor
Learn how to install, configure, and use the Aeotec MultiSensor 7, a Z-Wave 700 series smart home sensor for detecting ambient values and movement. This guide covers package contents, button functions, safety information, quick start, network inclusion, resetting, and advanced settings.
Preview Aeotec TriSensor Z-Wave Conformance Statement
Official Z-Wave Protocol Implementation Conformance Statement for the Aeotec TriSensor (ZWA005-S), detailing its technical specifications, features, and Z-Wave network capabilities.