Compact Design for High-Performance Service
The new DC Wallbox 50 kW is a compact and high-efficiency charging solution for commercial sites, offering ≥ 96% efficiency in an ultra-compact format of only 25 cm depth. It enables simultaneous DC charging via two connectors, making it ideal for roadside parking, shopping centers, office buildings, and EV depots, without requiring major modifications to existing infrastructure.
This new generation integrates advanced features such as: Status indicators to easily guide the driver to an available charging point; an NFC bank card reader for pay-as-you-go (ad hoc) charging; certified energy meters; an innovative cable management system for simple, clean, and ergonomic connection.
Application Scenarios
The application scenarios illustrate how the charging network integrates with backend management and software applications. Charging Networks, serving [Parking], [Commercial Areas], and [Transport Hubs], connect to an EV Charging Network Management System. This system facilitates remote access via a mobile application and supports Software Applications for Energy Management, Member and User Management, and Site/Building Management.
Key Advantages
≥ 96% Efficiency and High Power Density
- Simultaneous charging up to 50 kW with 62% less energy loss, saving up to 7,300 kWh per year
- Reduced footprint (1200 x 650 x 250 mm), ideal for wall or pedestal installation
- Robust design for indoor and outdoor use (IP55 and IK10)
Multi-directional Cable Use with Extended Reach
- Easy access from both sides of the vehicle with space optimization thanks to flexible deployment
- New cable management system allowing easy handling, regardless of vehicle position
- Optimized cable radius of 3.9 m, for smooth and unconstrained use
OCPP Support and Network Connectivity for Seamless Integration
- OCPP 1.6J compatible (extendable to OCPP 2.0)
- Integrated Ethernet and mobile (3G / 4G) network connections
- Integrable with commercial and management systems for optimized operation
Product Overview
The product overview highlights key features:
- Network Connectivity: Supports Ethernet and Mobile (3G/4G).
- Protection Rating: IP55 for dust and water resistance, IK10 for impact resistance.
- Public Charging Features: Includes an RFID reader, payment terminal, and certified energy meters.
- User Interface: Features status indicators and an advanced cable management system for user experience.
- Charging Standards: Offers CCS2 or CHAdeMO interfaces (up to 50 kW) and a Type 2 AC socket (up to 22kW).
Specifications
Feature | Specification | ||
---|---|---|---|
Model | DC Wallbox 50 kW | ||
Input | |||
Network Connection | Three-phase power supply (L1, L2, L3, N, PE) | ||
AC Voltage | 230 V / 400 V | ||
Frequency | 50 Hz / 60 Hz | ||
Nominal Current | 110 A | ||
Maximum Current | 125 A | ||
Power Factor / THDu | 0.99 / 1% | ||
Terminal | Screw terminals for eyelet lugs | ||
Protection | Overcurrent and overvoltage protection (Class II) | ||
Output Power | |||
Total System Power | 72 kW | ||
Maximum Number of Charging Ports | 3 charging ports operating simultaneously (2 DC and 1 AC) | ||
DC Charging Port | CCS | CHAdeMO | |
Nominal Power | 50 kW | 50 kW | |
Nominal Current | 125 A to 400 A | 125 A to 400 A | |
Maximum Current | 166 A | 125 A | |
Voltage Range | 200 to 920 V | 200 to 500 V | |
Cable Length | 5 m (7 m, 9 m optional) | 4 m (7 m, 9 m optional) | |
Protection | Ground fault and insulation monitoring | Ground fault and insulation monitoring | |
Compliance | IEC 61851-23 / -24, IEC 62196-3, DIN 70121 | IEC 61851-23 / -24, JEVS G 105 (Rev. 1.2) | |
AC Charging Port | Nominal Power | 22 kW | |
Nominal Current | 32 A per phase | ||
Charging Voltage | 230 V / 400 V | ||
Connector Type | Type 2 Socket (IEC 62196-2) | ||
Protection | Type A residual current circuit breaker (30 mA AC) and RDC-DD (6 mA DC) | ||
Compliance | IEC 61851-1, IEC 62196-2 | ||
User Interface | |||
Display | 7" LCD Screen | ||
Languages | English (optional: up to four additional languages) | ||
Navigation | 5 context-sensitive illuminated buttons. Emergency stop (optional) | ||
Authentication | NFC RFID ISO/IEC 1443 A/B payment card terminal with LCD screen and PIN keypad - various models available | ||
Status Indicators | LED bands indicating the status of each DC charging point | ||
Network Interface | |||
Cellular | Number | 2 (1 x backend connection and 1 x service access) | |
Cellular Technology | 2G / 3G / 4G | ||
SIM Card Format | Mini-SIM (25 mm x 15 mm) | ||
Protocols and Applications | Backend connection via OCPP 1.5 and OCPP 1.6 (tested with OCTT). Separate service access | ||
Ethernet | Connector Type | RJ45 | |
Protocols and Applications | Backend connection via OCPP 1.5 and OCPP 1.6 (tested with OCTT). ModBus TCP for the energy management system | ||
Mechanical Properties | |||
Dimensions* (L x H x D) | 650 × 1200 × 250 mm | ||
Protection Rating (IEC 60529) | IP55 | ||
Impact Protection (IEC 62262) | Enclosure: IK10 / LCD Screen: IK08 | ||
Cooling | Forced air | ||
Weight* | 115-165 kg (depending on configuration) | ||
Cable Management System | Spring-loaded cable management system (optional) | ||
Environmental Conditions | |||
Operating Temperature Range | -25 °C to +50 °C | ||
Storage Temperature Range | -40 °C to +80 °C | ||
Humidity | 95% relative humidity, non-condensing | ||
Altitude | Up to 2000 m | ||
Compliance | |||
European Low Voltage Directive | IEC 61851-1, IEC 61851-22, IEC 61851-23, IEC 62479 | ||
European Directive on Electromagnetic Interference | EN 55011, IEC 61851-21-2 | ||
Accessibility | DIN 18040 |