GIMA Alternating Pressure Mattress

User Manual

Introduction

All serious accidents concerning the medical device supplied by GIMA must be reported to the manufacturer and competent authority of the member state where your registered office is located.

The Alternating Pressure Mattress consists of two parts: the mattress and the pump. The pump utilizes a small compressor to remain quiet and energy efficient. The control panel is simple and very user friendly. The mattress relieves pressure by sequentially deflating and inflating alternate air cells on approximately 12 minutes timed intervals. It is widely recognized that constant pressure to a bony prominence is the leading cause of skin breakdown. The continuous movement supplied by the unit lessens the areas of constant pressure and enhances circulation.

Operation

  1. Place the mattress on the bed frame with the hose end at the foot section of the bed frame.
  2. Using the integrated hooks, securely hang the pump on the bed end at the foot end or place on a smooth flat surface.
  3. Connect the air hoses from the mattress to the pump.
  4. Plug the pump into a wall outlet. Be sure the power cord is safely away from possible hazards.
  5. Turn on the power switch on the control panel of the pump. The pump will begin to inflate the mattress.
  6. After inflation, adjust the mattress using the dial on the pump.

Caution

  1. Do not smoke on or near the pump.
  2. Keep the pump away from heated surfaces.
  3. Explosion risk if used in the presence of flammable anesthetics.
  4. Replace fuse as marked: T1A 250V. Power Input: ~ 220 V - 50 Hz - 0,1 A

Product Specifications

CategoryDetails
Maximum patient weight331lbs (150kg)
Operating power~ 220 V 50 Hz 0,1 A max.
FusesT1A 250 V

Environmental Conditions

Condition TypeOperating ConditionsStorage and Shipping Conditions
Ambient Temperature10°C to 40°C (50°F to 104°F)-18°C to +43°C (0°F to 110°F)
Relative Humidity10% to 75%10% to 95%

Compliance and Disposal

Symbols and Compliance:

  • ♻️ WEEE disposal: The product must not be disposed of along with other domestic waste. Users must bring this equipment to a specific recycling point for electric and electronic equipment.
  • ☀️ Keep away from sunlight.
  • ⚠️ Caution: read instructions (warnings) carefully.
  • CE: Medical Device compliant with Regulation (EU) 2017/745.
  • MD: Medical Device.
  • ? Follow instructions for use.
  • Type BF applied part.
  • Class II applied.

Warranty and Product Information

GIMA Warranty Terms: The Gima 12-month standard B2B warranty applies.

Product Code: REF 28575

Manufacturer: Gima S.p.A.

Address: Via Marconi, 1 - 20060 Gessate (MI) Italy

Contact: gima@gimaitaly.com - export@gimaitaly.com

Website: www.gimaitaly.com

Origin: Made in China

Models: Alternating Pressure Mattress

File Info : application/pdf, 2 Pages, 227.90KB

PDF preview unavailable. Download the PDF instead.

m28575en Adobe InDesign CC 13.1 (Macintosh) Adobe PDF Library 15.0

Related Documents

Preview GIMA Pressure Activated Safety Lancets (PA) - Medical Device for Capillary Blood Sampling
Information on GIMA Pressure Activated Safety Lancets (Model PA), a sterile, single-use device for capillary blood sampling. Includes intended use, instructions, warnings, storage, and disposal.
Preview GIMA Madrid Aneroid Sphygmomanometer - Professional Medical Product Information
Comprehensive guide to the GIMA Madrid Aneroid Sphygmomanometer (Model HS-201Q3), detailing its features, usage instructions, specifications, and maintenance. This document provides essential information for healthcare professionals and users.
Preview GIMA KD-595 Talking Automatic Blood Pressure Monitor User Manual
Comprehensive user manual for the GIMA KD-595 Talking Automatic Blood Pressure Monitor. Learn about setup, operation, specifications, troubleshooting, maintenance, and warranty.
Preview GIMA ARM-30E+ Blood Pressure Monitor User Manual
Comprehensive user manual for the GIMA ARM-30E+ upper arm blood pressure monitor, detailing setup, operation, safety precautions, troubleshooting, and technical specifications.
Preview GIMA ABPM50 Ambulatory Blood Pressure Monitor Technical Specifications
Detailed technical specifications for the GIMA ABPM50 Ambulatory Blood Pressure Monitor, including manufacturer information, power requirements, and safety class.
Preview GIMA ARM-30E+ Digital Blood Pressure Monitor User Manual
User manual for the GIMA ARM-30E+ digital blood pressure monitor, providing instructions on usage, safety precautions, maintenance, and troubleshooting.
Preview GIMA KURA TENS AD-2126 User Manual and Operation Guide
Comprehensive user and operation guide for the GIMA KURA TENS AD-2126 device, detailing intended use, specifications, setup, operation, troubleshooting, and maintenance for pain relief.
Preview GIMA Sterile Insulin Pen Needles: Instructions for Use, Specifications, and Safety
Comprehensive guide to GIMA sterile insulin pen needles (34G-28G). Learn about specifications, usage, safety precautions, contraindications, and storage for single-use insulin injection.