760146092 | P-001-SP-8W-F16BR
Fiber indoor cable, TeraSPEED® 1.6 mm Plenum, 1 fiber, Singlemode G.652.D and G.657.A1, Feet jacket marking, Brown jacket color.
Product Classification
- Regional Availability
- Asia | Australia/New Zealand | Latin America | Middle East/Africa | North America
- Portfolio
- CommScope®
- Product Type
- Fiber indoor cable
- Product Series
- P-SP
General Specifications
- Cable Type
- Cordage
- Construction Type
- Non-armored
- Subunit Type
- Gel-free
- Jacket Color
- Brown
- Jacket Marking
- Feet
- Total Fiber Count
- 1
Dimensions
- Diameter Over Jacket
- 1.7 mm | 0.067 in
Cable Construction Description
The cable construction, as depicted visually, includes an Outer Jacket, Aramid Yarn for strength, a 900 µm Tight Buffer, and a 250 µm Optical Fiber at its core.
Mechanical Specifications
- Minimum Bend Radius, loaded
- 38 mm | 1.496 in
- Minimum Bend Radius, unloaded
- 15 mm | 0.591 in
- Tensile Load, long term, maximum
- 29 N | 6.519 lbf
- Tensile Load, short term, maximum
- 98 N | 22.031 lbf
- Compression
- 10 N/mm | 57.101 lb/in
- Compression Test Method
- FOTP-41 | IEC 60794-1 E3
- Flex
- 300 cycles
- Flex Test Method
- FOTP-104 | IEC 60794-1 E6
- Impact
- 0.74 N-m | 6.55 in lb
- Impact Test Method
- FOTP-25 | IEC 60794-1 E4
- Strain
- See long and short term tensile loads
- Strain Test Method
- FOTP-33 | IEC 60794-1 E1
- Twist
- 10 cycles
- Twist Test Method
- FOTP-85 | IEC 60794-1 E7
- Vertical Rise, maximum
- 500 m | 1,640.42 ft
Optical Specifications
- Fiber Type
- G.652.D and G.657.A1, TeraSPEED®
Environmental Specifications
- Installation temperature
- 0 °C to +70 °C (+32 °F to +158 °F)
- Operating Temperature
- -20 °C to +70 °C (-4 °F to +158 °F)
- Storage Temperature
- -40 °C to +70 °C (-40 °F to +158 °F)
- Cable Qualification Standards
- ANSI/ICEA S-83-596 | Telcordia GR-409
- Environmental Space
- Plenum
- Flame Test Listing
- NEC OFNP (ETL) and c(ETL)
- Flame Test Method
- NFPA 130 | NFPA 262
Environmental Test Specifications
- Heat Age
- -20 °C to +85 °C (-4 °F to +185 °F)
- Heat Age Test Method
- IEC 60794-1 F9
- Low High Bend
- -20 °C to +70 °C (-4 °F to +158 °F)
- Low High Bend Test Method
- FOTP-37 | IEC 60794-1 E11
- Temperature Cycle
- -20 °C to +70 °C (-4 °F to +158 °F)
- Temperature Cycle Test Method
- FOTP-3 | IEC 60794-1 F1
Packaging and Weights
- Cable weight
- 3 kg/km | 2.016 lb/kft
Included Products
CS-8W-TB = TeraSPEED® Singlemode Fiber
Footnotes
Operating Temperature Specification applicable to non-terminated bulk fiber cable.
For additional trademark information see https://www.commscope.com/trademarks.