760146100 | P-001-SP-8W-F16SL
Fiber indoor cable, TeraSPEED® 1.6 mm Plenum, 1 fiber, Singlemode G.652.D and G.657.A1, Feet jacket marking, Slate jacket color
Product Classification
Regional Availability: Asia, Australia/New Zealand, Latin America, Middle East/Africa, North America
Portfolio: CommScope®
Product Type: Fiber indoor cable
Product Series: P-SP
General Specifications
Cable Type | Cordage |
---|---|
Construction Type | Non-armored |
Subunit Type | Gel-free |
Jacket Color | Slate |
Jacket Marking | Feet |
Total Fiber Count | 1 |
Dimensions
Diameter Over Jacket: 1.7 mm | 0.067 in
Cable Structure Description
The cable structure consists of an outer jacket, aramid yarn for strength, a 900 µm tight buffer, and a 250 µm optical fiber.
Mechanical Specifications
Specification | Value | Test Method |
---|---|---|
Minimum Bend Radius, loaded | 38 mm | 1.496 in | |
Minimum Bend Radius, unloaded | 15 mm | 0.591 in | |
Tensile Load, long term, maximum | 29 N | 6.519 lbf | |
Tensile Load, short term, maximum | 98 N | 22.031 lbf | |
Compression | 10 N/mm | 57.101 lb/in | |
Compression Test Method | FOTP-41 | IEC 60794-1 E3 | |
Flex | 300 cycles | |
Flex Test Method | FOTP-104 | IEC 60794-1 E6 | |
Impact | 0.74 N-m | 6.55 in lb | |
Impact Test Method | FOTP-25 | IEC 60794-1 E4 | |
Strain | See long and short term tensile loads | |
Strain Test Method | FOTP-33 | IEC 60794-1 E1 | |
Twist | 10 cycles | |
Twist Test Method | FOTP-85 | IEC 60794-1 E7 | |
Vertical Rise, maximum | 500 m | 1,640.42 ft |
Optical Specifications
Fiber Type: G.652.D and G.657.A1, TeraSPEED®
Environmental Specifications
Specification | Value |
---|---|
Installation temperature | 0 °C to +70 °C (+32 °F to +158 °F) |
Operating Temperature | -20 °C to +70 °C (-4 °F to +158 °F) |
Storage Temperature | -40 °C to +70 °C (-40 °F to +158 °F) |
Cable Qualification Standards | ANSI/ICEA S-83-596 | Telcordia GR-409 |
Environmental Space | Plenum |
Flame Test Listing | NEC OFNP (ETL) and c(ETL) |
Flame Test Method | NFPA 130 | NFPA 262 |
Environmental Test Specifications
Test | Value | Test Method |
---|---|---|
Heat Age | -20 °C to +85 °C (-4 °F to +185 °F) | IEC 60794-1 F9 |
Low High Bend | -20 °C to +70 °C (-4 °F to +158 °F) | FOTP-37 | IEC 60794-1 E11 |
Temperature Cycle | -20 °C to +70 °C (-4 °F to +158 °F) | FOTP-3 | IEC 60794-1 F1 |
Packaging and Weights
Cable weight: 3 kg/km | 2.016 lb/kft
Included Products
- CS-8W-TB - TeraSPEED® Singlemode Fiber
Footnotes
* Operating Temperature Specification applicable to non-terminated bulk fiber cable