Installation Manuals Available
- INSTALLATION MANUAL (EN)
- INSTALLATIONSHANDBUCH (DE)
- MANUEL D'INSTALLATION (FR)
- MANUAL DE INSTALACIÓN (ES)
- MANUALE DI INSTALLAZIONE E USO (IT)
Company Information
DOMUS LINE Srl
Via Maestri del Lavoro, 1
33080 PORCIA _ PN _ Italy
Phone: 0039 0434 595911
Fax: 0039 0434 923345
E-mail: info@domusline.com
Website: www.domusline.com
Ref. 3480900 r9
Product Information and Safety
Device in insulation class II: Connection to the earthing circuit is not necessary.
Lamp power supply unit thermally protected at 110°C
Independent transformer: Specially designed to be installed "visible" (can be used without supplementary protective case and without being integrated into lights).
SELV Symbol (Safety Extra Low Voltage): Indicates a transformer where touching the secondary circuit outputs, even with no lamps connected, does not constitute a hazard.
Disposal: The product must be disposed of separately from urban waste at designated collection centers. Proper waste collection prevents negative environmental and health effects and promotes reuse/recycling. Improper disposal may result in administrative sanctions.
Specifications
Input voltage | X-DRIVER 15Watt: 100-120VAC, 220-240Vac X-DRIVER 30Watt: 100-120VAC, 220-240Vac (100-120VAC for North America only) X-DRIVER 60Watt: 100-120VAC, 220-240Vac X-DRIVER 96Watt: 100-120VAC, 220-240Vac |
Input frequency | 50/60Hz |
Input current | X-DRIVER 15Watt: 0.25A for 100-120Vac, 0.12A for 220-240Vac X-DRIVER 30Watt: 0.40A for 100-120Vac, 0.20A for 220-240Vac X-DRIVER 60Watt: 0.80A for 100-120Vac, 0.35A for 220-240Vac X-DRIVER 96Watt: 0.90A for 100-120Vac, 0.45A for 220-240Vac |
Output voltage | X-DRIVER 15Watt: 12-24Vdc X-DRIVER 30Watt: 12-24Vdc X-DRIVER 60Watt: 12-24Vdc X-DRIVER 96Watt: 24Vdc |
Rated output power | X-DRIVER 15Watt: 0-15W X-DRIVER 30Watt: 0-30W X-DRIVER 60Watt: 0-60W X-DRIVER 96Watt: 0-96W |
Dimming range | 2%-100% |
Operation mode | PWM+PFM |
Ambient temperature | -20...+40°C |
IP protection | IP20 |
Optional Accessories
Type | MODULE CM1-XD | MODULE CM2-XD | MODULE CM3-XD | MODULE CM4-XD | Input Cable |
---|---|---|---|---|---|
Picture | [Diagram of CM1-XD module] | [Diagram of CM2-XD module] | [Diagram of CM3-XD module] | [Diagram of CM4-XD module] NOT FOR X-DRIVER 15W | [Diagram of input cable] OR |
RADIO RECEIVER FOR LIGHTING CONTROL | - | Radio receiver for lighting control Model: CM2-XD RECEIVER CONTROLLER IC: 26990-CM2 FCC ID: 2AX76-CM2 |
Radio receiver for lighting control Model: CM3-XD RECEIVER CONTROLLER IC: 26990-CM3 FCC ID: 2AX76-CM3 |
Radio receiver for lighting control Model: CM4-XD RECEIVER CONTROLLER IC: 26990-CM4 FCC ID: 2AX76-CM4 |
- |
Function Characteristics | IR/IFR | IR/IFR/2.4G | IR/IFR/BT | ONLY APP | - |
Functional Fittings | [Diagram of IR XD] [Diagram of PIR XD] |
[Diagram of IR XD] [Diagram of PIR XD] Call-ME V17 Rc3 Rc1 |
[Diagram of IR XD] [Diagram of PIR XD] APP DOMUS 4 U WIFI |
[Diagram of PIR XD] APP DOMUS 4 U |
- |
Module Installation
SERIES: X-DRIVER 15-30-60Watt
[Diagram showing connection of IR XD and PIR XD sensors to the X-DRIVER unit]
[Diagram showing the process of opening the X-DRIVER unit for module installation]
[Diagram showing the installation of a module into the X-DRIVER unit]
Modules: CM1-XD, CM2-XD, CM3-XD, CM4-XD (NOT FOR X-DRIVER 15W)
IR-XD LSW and IR-XD DSW Operation
IR-XD LSW Installation: [Diagram showing installation of IR-XD LSW, including placement relative to a surface, with dimensions min. 1mm and max. 2-10cm]
IR-XD DSW Dimming Control:
- 100% to 0%: [Diagram showing a hand adjusting a dimmer, transitioning from 100% brightness to 0%]
- 2% to 100%: [Diagram showing a hand adjusting a dimmer, transitioning from 2% brightness to 100%]
- 100% to 2%: [Diagram showing a hand adjusting a dimmer, transitioning from 100% brightness to 2%]
Material Specifications:
Material | Finish | H max. | H min. |
---|---|---|---|
laminate | dark oak | 20-30mm | 1mm |
varnished | bright white | 80-100mm | 1mm |
wood | natural | 60-80mm | 1mm |
PIR XD Sensor Operation
[Diagram illustrating the PIR XD sensor activation sequence. Upon detection (indicated by a blue light), the light turns on for a set duration (e.g., 10 sec, 3 min, 10 min). The sequence shows multiple activation possibilities with different durations.]
Remote Control Operation
Remote Control Matched Transmitter:
- [Diagram showing a remote control (RC3) being paired with the X-DRIVER unit. The process involves pressing buttons on the remote and observing indicator lights (blue) on the unit. The control allows for brightness adjustment and ON/OFF functions.]
- For detail instruction: Please see the manual of Remote controller dimmer or Remote controller 3 channels. Max. number of controllers connected for one smart driver: 7pcs.
PAY ATTENTION FIRST CONNECTION:
- [Diagram showing a 60-second delay before the device operates, indicated by a STOP symbol and LED.]
- [Diagram showing pairing of RC3, RC1, and CALL-ME V17 with the X-DRIVER, with some pairings indicated as incorrect (X symbol).]
Remote controller RC1: [Diagram showing pairing of RC1 with the X-DRIVER, involving a 5-second delay and observing blue indicator lights. Max. number of controllers connected for one smart driver: 7pcs.]
Remote controller dimmer CALL-ME V17: [Diagram showing pairing of CALL-ME V17 with the X-DRIVER, involving a 1-second delay and 2x button presses, observing blue indicator lights. Max. number of controllers connected for one smart driver: 7pcs.]
Reset Matched Transmitter
[Diagram showing the process to reset the transmitter. This involves pressing a button on the X-DRIVER unit with a screwdriver multiple times (1x or 3x) while observing blue indicator lights.]
Available Transmitters: Call-ME V17, RC1, RC3
Remote Control Function Details
Single Remote (e.g., CALL-ME V17):
- ON/OFF: [Diagram showing an ON/OFF button on a remote.]
- Brightness Control: [Diagrams showing a circular control on a remote. Pressing the control increases brightness from 10% to 100% and decreases from 100% to 10%.]
Multiple Remotes (e.g., RC1, RC3):
- ON/OFF: [Diagram showing an ON/OFF button on a remote.]
- Brightness Control: [Diagrams showing buttons on a remote. Pressing one button increases brightness, and another decreases it.]
Call-ME V17 Specific Control: [Diagram showing the ON/OFF button and a control for increasing/decreasing brightness on the Call-ME V17.]
App. DOMUS 4U
Download APP: Scan QR codes to download the app from the App Store or Google Play.
[QR code for App Store download] [QR code for Google Play download]
Search for Devices: The DOMUS4U application uses LE Bluetooth technology to find Domus Line X-DRIVER devices. It allows users to switch on/off and adjust brightness or color of connected devices.
Device Management: Users can store and rename devices (e.g., Kitchen lights, Bathroom lights).
Video Tutorials: Links and text provided for installation video tutorials in multiple languages (Italian, English, German, French, Spanish).
App Interface: [Screenshot of the DOMUS 4U app interface showing 'USE' and 'CONFIGURATION' sections, with options like Lighting, Rooms, News, Info.]
DOMUS 4U Wi-Fi
Compatibility: APP compatible with X-DRIVER and CM4-XD to manage lights from smartphones.
Download the App:
[App Store download button] [Google Play download button]
[QR code for App Store download] [QR code for Google Play download]
Links: http://bit.ly/domus4uwifi, http://bit.ly/domus4uwifigoogleplay
General Installation and Safety Warnings
WARNING: Follow instructions carefully. Installation may require qualified personnel. Ensure environmental conditions are suitable. Disconnect mains power before any operation.
INTRODUCTION: Power supply is designed exclusively for LED lamps. Can be used with control modules, IR/PIR sensors, remote controls, and the APP.
Protection Circuit: Built-in circuit turns off power during short circuit, overload, or overheating. X-DRIVER restarts automatically after the problem is resolved.
WARRANTY: Warranty is valid only if powered by a DOMUS Line power supply. General terms and conditions available at www.domusline.com.
FCC Compliance: This device complies with Part 15 of the FCC Rules. Operation is subject to two conditions: (1) no harmful interference, and (2) acceptance of any received interference. Changes not expressly approved may void user's authority to operate.
FCC Note: Tested and complies with Class B digital device limits for reasonable protection against harmful interference in residential installations. May cause interference if not installed per instructions. If interference occurs, try relocating the antenna, increasing separation, or connecting to a different circuit. Consult dealer or technician if needed.
FCC Warning: This equipment complies with FCC radiation exposure limits for an uncontrolled environment. Install and operate with minimum 20cm distance between radiator and body.
IC Warning: Complies with Industry Canada licence-exempt RSS standard(s). Operation subject to two conditions: (1) no interference, and (2) acceptance of any interference. User must not compromise the device's function.