TÜV Rheinland Test Report: IKEA LED Light Chain J2507

Test Report Number: CN24DX3G 001

Client Reference Number: 1288983

Client: IKEA of Sweden AB

Test Item: LED light chain

Identification / Type No.: J2507

Order Date: 2024-07-24

Issue Date: 2025-01-09

1 Test Sites

1.1 Test Facilities

Laboratory: TÜV Rheinland (Shanghai) Co., Ltd.

Address: Workshop14, North Half of Workshop 10 and Workshop 16, Pingqian (Taicang) Modern Industrial Park, No.525, Yuewang Lingang South Road, Shaxi, Taicang, Jiangsu, China

The test equipment used complies with CISPR 16-1 series standards for radio interference measurement.

2 General Product Information

2.1 Product Function and Intended Use

The Equipment Under Test (EUT) is an LED light chain intended for general lighting and similar applications. For detailed information, refer to the user's manual.

2.2 Ratings and System Details

2.3 Independent Operation Modes

The basic operation modes are: "lighting on", "flashing", and "off".

2.4 Description of Interconnecting Cables

No. Interface and Name Shielded or Not Specified Length (m)
1 AC power line of LED driver Unshielded 0.95
2 DC power line of LED driver Unshielded 5.1

2.5 Noise Generating and Noise Suppressing Parts

Refer to the circuit diagram for details.

2.6 Highest Frequency Generated or Used

The highest frequency used in the EUT is 24 MHz.

2.7 Submitted Documents

Circuit diagram, user's manual, and rating label.

3 Test Set-up and Operation Modes

3.1 Principle of Configuration Selection

For emission testing, the EUT was configured to achieve its highest possible emission level. Test conditions were adapted based on the instructions for use. Radiated emission tests were performed on 2024-12-31, and conducted emission tests were performed on 2025-01-02.

3.2 Equipment and Cable Arrangement

Block diagrams illustrating the test setups for conducted and radiated emission tests are provided. The conducted emission setup involves the EUT, EMI receiver, LISN, transformer, power supply, and computer. The radiated emission setup includes the EUT, antenna, EMI receiver, and computer, with the EUT placed on a wooden support at a specified distance from the antenna.

3.3 Test Software

No special test software was utilized during the tests.

3.4 Special Accessories and Auxiliary Equipment

None were used.

3.5 Countermeasures to achieve EMC Compliance

No specific measures were employed to achieve compliance beyond standard setup procedures.

4 Conformity Decision Rule

For all EMI tests in this report, compliance is determined by comparing measurement results directly with the specified limits. Measurement uncertainties are considered less than the values given in CISPR 16-4-2, and therefore, they are not factored into the compliance determination.

5 Test Results: Emission

5.1 Emission in the Frequency Range up to 30 MHz (Conducted Emission)

Test Procedure: FCC 47 CFR Part 15, Subpart B:2023, ICES-005:2018, ANSI C63.4-2014, CISPR 16-2-1

Frequency Range: 0.15 - 30 MHz

Limits:

Bandwidth of EMI receiver: 9 kHz

Measurement time: 1 s

Kind of test site: Shielded room

Input voltage: AC 120 V, 60 Hz

Ambient condition: Temperature: 24.1 °C; Relative humidity: 47.2 %

Expanded measurement uncertainty (k=2): 2.33 dB

The minimum margin to the limit was 6.61 dB at 0.159000 MHz, which is higher than the expanded measurement uncertainty.

Mode 1: Lighting On

Quasi-Peak Measurements
Frequency (MHz) QuasiPeak (dBuV) Limit (dBuV) Margin (dB) Meas. Time (ms) Bandwidth (kHz) Line
0.156750 58.41 65.63 7.22 1000.0 9.000 L1
0.586500 36.91 56.00 19.09 1000.0 9.000 L1
0.690000 30.46 56.00 25.54 1000.0 9.000 L1
1.171500 31.83 56.00 24.17 1000.0 9.000 L1
2.501250 32.26 56.00 23.74 1000.0 9.000 L1
9.330000 34.31 60.00 25.69 1000.0 9.000 L1
Average Measurements
Frequency (MHz) CAverage (dBuV) Limit (dBuV) Margin (dB) Meas. Time (ms) Bandwidth (kHz) Line
0.159000 48.72 55.52 6.80 1000.0 9.000 L1
0.534750 23.75 46.00 22.25 1000.0 9.000 L1
0.588750 25.55 46.00 20.45 1000.0 9.000 L1
2.501250 21.22 46.00 24.78 1000.0 9.000 L1
4.107750 20.38 46.00 25.62 1000.0 9.000 L1
9.332250 25.17 50.00 24.83 1000.0 9.000 L1

Mode 1: Lighting On (Neutral Line)

Quasi-Peak Measurements
Frequency (MHz) QuasiPeak (dBuV) Limit (dBuV) Margin (dB) Meas. Time (ms) Bandwidth (kHz) Line
0.156750 58.46 65.63 7.18 1000.0 9.000 N
0.591000 35.75 56.00 20.25 1000.0 9.000 N
2.091750 31.54 56.00 24.46 1000.0 9.000 N
2.145750 32.04 56.00 23.96 1000.0 9.000 N
9.339000 33.43 60.00 26.57 1000.0 9.000 N
18.802500 24.22 60.00 35.78 1000.0 9.000 N
Average Measurements
Frequency (MHz) CAverage (dBuV) Limit (dBuV) Margin (dB) Meas. Time (ms) Bandwidth (kHz) Line
0.159000 48.91 55.52 6.61 1000.0 9.000 N
0.534750 22.39 46.00 23.62 1000.0 9.000 N
0.588750 24.73 46.00 21.27 1000.0 9.000 N
2.091750 23.03 46.00 22.97 1000.0 9.000 N
2.568750 23.97 46.00 22.03 1000.0 9.000 N
9.300750 24.84 50.00 25.16 1000.0 9.000 N

Mode 2: Lighting On (Phase Line)

Quasi-Peak Measurements
Frequency (MHz) QuasiPeak (dBuV) Limit (dBuV) Margin (dB) Meas. Time (ms) Bandwidth (kHz) Line
0.163500 58.27 65.28 7.02 1000.0 9.000 L1
0.597750 39.36 56.00 16.64 1000.0 9.000 L1
2.024250 32.25 56.00 23.75 1000.0 9.000 L1
2.294250 41.86 56.00 14.14 1000.0 9.000 L1
4.983000 32.61 56.00 23.39 1000.0 9.000 L1
9.240000 36.83 60.00 23.17 1000.0 9.000 L1
Average Measurements
Frequency (MHz) CAverage (dBuV) Limit (dBuV) Margin (dB) Meas. Time (ms) Bandwidth (kHz) Line
0.161250 43.71 55.40 11.69 1000.0 9.000 L1
0.595500 30.14 46.00 15.86 1000.0 9.000 L1
2.024250 24.24 46.00 21.76 1000.0 9.000 L1
2.294250 36.98 46.00 9.02 1000.0 9.000 L1
4.983000 27.85 46.00 18.15 1000.0 9.000 L1
9.361500 28.96 50.00 21.04 1000.0 9.000 L1

Mode 2: Lighting On (Neutral Line)

Quasi-Peak Measurements
Frequency (MHz) QuasiPeak (dBuV) Limit (dBuV) Margin (dB) Meas. Time (ms) Bandwidth (kHz) Line
0.163500 57.03 65.28 8.25 1000.0 9.000 N
0.595500 39.04 56.00 16.96 1000.0 9.000 N
1.990500 31.75 56.00 24.25 1000.0 9.000 N
2.283000 41.04 56.00 14.96 1000.0 9.000 N
4.978500 34.01 56.00 21.99 1000.0 9.000 N
9.233250 36.72 60.00 23.28 1000.0 9.000 N
Average Measurements
Frequency (MHz) CAverage (dBuV) Limit (dBuV) Margin (dB) Meas. Time (ms) Bandwidth (kHz) Line
0.161250 44.09 55.40 11.31 1000.0 9.000 N
0.595500 29.21 46.00 16.79 1000.0 9.000 N
2.001750 24.74 46.00 21.26 1000.0 9.000 N
2.292000 37.20 46.00 8.80 1000.0 9.000 N
4.998750 28.54 46.00 17.46 1000.0 9.000 N
9.384000 29.78 50.00 20.22 1000.0 9.000 N

5.2 Emission in the Frequency Range above 30 MHz (Radiated Emission 30-1000 MHz)

Test Procedure: FCC 47 CFR Part 15, Subpart B:2023, ICES-005:2018, ANSI C63.4-2014, CISPR 16-2-3

Product Classification: Class B

Frequency Range: 30 – 1000 MHz

Limits (3 m distance):

Bandwidth of EMI receiver: 120 kHz

Measurement time: 1 s

Kind of test site: Semi-anechoic chamber

Input voltage: AC 120 V, 60 Hz

Ambient condition: Temperature: 24.6 °C; Relative humidity: 45.5 %

Expanded measurement uncertainty (k=2): 5.40 dB

The minimum margin to the limit was 8.1 dB at 31.091250 MHz.

The test was conducted in a semi-anechoic chamber with a 3 m test distance. The EUT was placed on an 80 cm wooden support and rotated 360°. Antenna height was varied from 1 m to 4 m. Tests were performed with the antenna in horizontal and vertical polarizations.

Mode 1: Lighting On (Horizontal Polarization)

Frequency (MHz) QuasiPeak (dBuV/m) Bandwidth (kHz) Height (cm) Pol Azimuth (deg) Corr. (dB/m) Margin - QPK (dB) Limit - QPK (dBuV/m)
31.818750 27.3 120.000 277 H 121 23.9 12.7 40.0
114.875000 21.9 120.000 114 H -26 18.8 21.6 43.5
141.913750 22.3 120.000 191 H -172 18.1 21.3 43.5
260.496250 23.9 120.000 269 H 128 20.8 22.2 46.0
619.881250 30.5 120.000 400 H 126 26.9 15.5 46.0
930.281250 33.3 120.000 391 H 103 28.9 12.7 46.0

Mode 1: Lighting On (Vertical Polarization)

Frequency (MHz) QuasiPeak (dBuV/m) Bandwidth (kHz) Height (cm) Pol Azimuth (deg) Corr. (dB/m) Margin - QPK (dB) Limit - QPK (dBuV/m)
30.242500 30.3 120.000 159 V 66 24.7 9.7 40.0
30.485000 30.5 120.000 247 V 59 24.6 9.5 40.0
31.091250 31.9 120.000 391 V -160 24.3 8.1 40.0
44.913750 30.3 120.000 256 V -53 17.2 9.7 40.0
111.358750 21.8 120.000 325 V 52 18.7 21.7 43.5
890.147500 33.3 120.000 156 V 27 28.7 12.7 46.0

Mode 2: Lighting On (Horizontal Polarization)

Frequency (MHz) QuasiPeak (dBuV/m) Bandwidth (kHz) Height (cm) Pol Azimuth (deg) Corr. (dB/m) Margin - QPK (dB) Limit - QPK (dBuV/m)
30.485000 28.0 120.000 384 H -27 24.6 12.0 40.0
135.002500 21.5 120.000 172 H 71 18.4 22.0 43.5
263.406250 23.9 120.000 297 H -96 20.8 22.1 46.0
411.816250 27.0 120.000 345 H 168 23.7 19.0 46.0
619.275000 30.4 120.000 281 H 36 26.9 15.6 46.0
960.836250 33.7 120.000 276 H -133 29.5 12.3 46.0

Mode 2: Lighting On (Vertical Polarization)

Frequency (MHz) QuasiPeak (dBuV/m) Bandwidth (kHz) Height (cm) Pol Azimuth (deg) Corr. (dB/m) Margin - QPK (dB) Limit - QPK (dBuV/m)
31.091250 31.7 120.000 259 V 3 24.3 8.3 40.0
31.455000 31.4 120.000 212 V -21 24.1 8.6 40.0
44.671250 31.7 120.000 117 V -125 17.3 8.3 40.0
45.035000 31.3 120.000 322 V 129 17.1 8.7 40.0
130.395000 21.8 120.000 127 V -100 18.7 21.7 43.5
888.571250 33.3 120.000 293 V 117 28.7 12.7 46.0

6 Photographs of the Test Set-Up

Photographs of the test set-up are available in a separate test setup file.

7 List of Test and Measurement Instruments

Equip. Description Model Manufacturer Last Date Due Date
9061503 Shielded enclosure 10.055x3.605x3.000 Frankonia 08.11.2023 08.11.2028
9023229 EMI test receiver ESR3 Rohde & Schwarz 03.08.2024 03.08.2025
G1830003 Artificial mains network ENV432 Rohde & Schwarz 11.10.2024 11.10.2025
G1824248 Dual display multimeter F45 Fluke 28.06.2024 28.06.2025
9062744 EMI measurement software EMC32-E+(10.60.20) Rohde & Schwarz N/A N/A
G1811378 3m semi-anechoic chamber SAC3 Frankonia 03.12.2023 03.12.2026
G1811391 EMI test receiver ESCI Rohde&Schwarz 17.10.2024 17.10.2025
G1811425 Bilog antenna CBL 6112D Teseq 20.04.2023 20.04.2026
9062745 EMI measurement software EMC32-MEB (10.60.20) Rohde & Schwarz N/A N/A

8 List of Figures

PDF preview unavailable. Download the PDF instead.

GetApplicationAttachment.html?id=7968112 Microsoft Word for Microsoft 365; modified using iTextSharp™ 5.5.13.3 ©2000-2022 iText Group NV (AGPL-version)

Related Documents

Preview IKEA J2519 LED Light Chain EMC Test Report - FCC & IC Compliance
Official EMC test report for the IKEA J2519 LED light chain, detailing conducted and radiated emission test results according to FCC Part 15 and ICES-005 standards. Includes test setup, equipment, and compliance decision.
Preview TÜV Rheinland Test Report: IKEA LED Light Chain J2513
This report details the EMC test results for the IKEA LED Light Chain (Model J2513), conducted by TÜV Rheinland according to FCC and ICES standards, confirming compliance.
Preview IKEA LED Light Chain J2520 EMC Test Report - TÜV Rheinland
This report details the Electromagnetic Compatibility (EMC) testing conducted by TÜV Rheinland on the IKEA LED Light Chain, model J2520, according to FCC Part 15 and ICES-005 standards.
Preview IKEA LED Light Chain J2512 EMC Test Report
Electromagnetic Compatibility (EMC) test report for the IKEA LED Light Chain, model J2512. This report details conducted and radiated emission test results performed by TÜV Rheinland according to FCC and ICES standards.
Preview TÜV Rheinland EMC Test Report for IKEA LED Light Chain J2504
This report from TÜV Rheinland details the Electromagnetic Compatibility (EMC) testing performed on the IKEA LED light chain (Model J2504) according to FCC Part 15 Subpart B and ICES-005 standards. It includes conducted and radiated emission test results, equipment details, and test setup configurations.
Preview GETKÅL J2507 LED Lighting Chain Technical Specifications and Compliance
Detailed specifications and compliance information for the IKEA GETKÅL J2507 LED lighting chain, including electrical ratings, FCC, CSA, and UL certifications.
Preview TÜV Rheinland Test Report: IKEA LED Lighting Chain J2505 (CN245XPT 001)
This report details the EMC testing conducted by TÜV Rheinland on the IKEA LED Lighting Chain, model J2505 (FCC ID: FHO-J2505), for compliance with FCC Part 15 Subpart B and ICES-005 standards.
Preview TÜV Rheinland Test Report: IKEA LED Lighting Chain (Model J2503)
This report details the Electromagnetic Compatibility (EMC) testing conducted by TÜV Rheinland on the IKEA LED lighting chain, model J2503. The testing covers conducted and radiated emissions according to FCC 47 CFR Part 15, Subpart B:2022 and ICES-005:2018 standards. It includes test setup descriptions, measurement results, and instrument lists.