Calix E7-2 VDSL2-48D r2
Product Datasheet
Description
The Calix E7-2 VDSL2-48 r2 card combines 48 VDSL2/ADSL2+ subscriber ports with integrated 10G/1G Ethernet transport to provide a very compact, high-density DSL solution. Two E7-2 VDSL2-48 r2 line cards can be plugged into a Calix E7-2 shelf to create a compact, very high-density DSL node, with Ethernet aggregation and transport, ideal for copper-based delivery of IP services across the access network. With the E7-2 VDSL2-48 r2 cards ability to support vectoring and 8 pair bonding, it supports a full set of residential and business services.
[Image: A photograph of the Calix E7-2 VDSL2-48D r2 line card, showing its compact form factor and port layout.]
Key Attributes
- High DSL Interface Density: The Calix E7 VDSL2-48D r2 line card is equipped with 48 VDSL2/ADSL2+ Fallback ports, supporting single line and any-to-any pair bonded subscriber connectivity. Two such cards in an E7-2 chassis provide 96 ports in a 1RU chassis for DSL and VoIP access.
- Integrated Vectoring Support: The E7 VDSL2-48 r2 line cards support unit-level and system-level vectoring for higher subscriber bandwidth. The E7-2 supports 96 ports of system-level vectoring without an external vector control processor. With the E7 VCP-192 or E7 VCP-384 vector control processor, system-level vectoring can be extended up to 384 ports.
- Copper Bonded Services/Transport: The E7-2 VDSL2-48D r2 enables service providers to deliver high-bandwidth symmetric services using copper bonding where fiber is not available. The card can deliver services over up to 8 bonded pairs per subscriber for services or to a next-hop cabinet location for transport.
- Industry Standards Compliance: The Calix E7 VDSL2-48D R2 card complies with applicable ADSL/VDSL2 ITU standards including G.992.1 (ADSL/G.dmt), G.992.2 (G.Lite), G.992.3/4 (ADSL2), G.992.5 (ADSL2+), G.993.2 (VDSL2), G.994.1 (G.hs), G.998.2 (VDSL2 Ethernet Pair Bonding), G.998.1 (ATM-based multi-pair bonding), G.998.4 (G.inp), G.993.5 (G.Vector), and ANSI T1.413, ensuring interoperability with a wide range of CPE.
- Native IPTV Support: The E7 supports industry-standard IGMP snooping and proxy to identify and replicate multicast video sent between the set-top box and the video distribution network, providing efficient, scalable, high-quality IPTV distribution on DSL subscriber interfaces.
- Network Interface Options: Industry-standard pluggable modules are used for all E7 VDSL2-48D r2 Ethernet interfaces, including Small Form-Factor Pluggable (SFP) optical and copper Gigabit Ethernet, and SFP+ 10GE modules. Ethernet SFP ports support 1 Gigabit or 2.5 Gigabit data rates. SFP+ ports also support GE SFP modules, offering additional 1GE or 10GE transport flexibility.
- High Availability Ethernet Transport: The Calix E7 system bridges the gap between traditional DSL service access nodes and Ethernet switches, providing copper pair service drops and Ethernet-based transport and aggregation. The VDSL2-48D r2 card includes two 10GE ports for uplink and transport for the local E7 system, or to subtend additional E7 chassis to extend DSL access capacity. Multiple E7 systems can be linked together at 2.5GE or 10GE stacking ring data rates using low-cost copper cables.
- Network Resiliency: All Calix E7 cards support standards-based network topology protocols for aggregation, ring-based transport, and uplink applications, including:
- ITU G.8032 Ethernet Ring Protection Switching (ERPS)
- IEEE 802.1w Rapid Spanning Tree Protocol (RSTP)
- IEEE 802.3ad/802.1AX Link Aggregation
- Delivering “Quality of Experience“: The E7 provides per-subscriber and per-service hierarchical QoS to deliver uncompromised triple play and business services. Classification, policing, queuing, and scheduling algorithms allow operators to manage per-subscriber and per-service traffic flows to maintain priority/delay/loss differentiation within the E7 network.
Specifications
Category | Details |
---|---|
Minimum System Requirements | Calix E7-2 shelf support only; Two VDSL2-48D R2 line cards per E7-2 chassis; Calix E7 Software Release 2.4 |
Dimensions (W x L x H) | 14 x 10.1 x 0.78 inches (35.6 x 25.7 x 2 cm) |
Ports | 48 ports VDSL2/ADSL2+ Fallback; 2 SFP sockets at 1GE/2.5GE rates; 2 SFP+ ports supporting 10GE and GE modules; 1 Vector Control Interface port |
VDSL2 Ethernet Packet Transfer Mode | VDSL2 ITU-T G.993.2; ITU-T G.994.1 G.hs or Handshake; Compliant with IEEE STD 802.3AH-2004, Ethernet in the First Mile (EFM) |
ADSL2+ Format | Full-rate ANSI T1.413, Issue 2; G.DMT full-rate ITU-T G.992.1; G.Lite ITU-T G.992.2; ADSL2 ITU-T G.992.3 including Annexes A/L/M; ADSL2+ ITU-T G.992.5 including Annex A/M; ITU-T G.994.1 G.hs or Handshake |
XDSL Multi-Pair Bonding | ITU-T G.998.1 ADSL2+ ATM-based multi-pair Bonding; ITU-T G.998.2 VDSL2 PTM-based multi-pair Bonding |
E7 Port Concentration | Two VDSL2-48D R2 line cards per E7-2; 96 DSL ports per 1RU chassis |
Maximum Line Rates | VDSL2 (1 pair): Selectable in 64-Kbps increments. Profile 17a: up to 140 Mbps downstream, 60 Mbps upstream. Profile 12a/b: up to 100Mbps downstream, 30 Mbps upstream. Selectable in 64-Kbps increments. Profile 8a/b/c/d: up to 80Mbps downstream, 20 Mbps upstream. 2 pair VDSL2 Bonding: Profile 17a: Aggregate data rate up to 160 Mbps downstream, 120 Mbps upstream. 8 pair VDSL2 Bonding: Profile 17a: Aggregate data rate up to 918Mbps downstream, 340 Mbps upstream. ADSL2+: up to 24 Mbps downstream, 3 Mbps upstream. Selectable in 64-Kbps increments. ADSL2+ Bonding (2 pairs): up to 45 Mbps downstream, 5 Mbps upstream, selectable in 64-Kbps increments. Full rate ADSL: up to 8 Mbps downstream, 896 Kbps upstream. Selectable in 64-Kbps increments. |
Standards Support | Broadband Forum TR-101 DHCP Relay, and Layer 2 DHCP Relay w/ DHCP Option 82 insertion; Broadband Forum TR-114 "VDSL2 Performance Test Plan", and TR-115 "VDSL2 Functionality Test Plan"; IGMPv2 & IGMPv3 Proxy and Snooping; IEEE 801.X (EAPOL); IEEE 802.1Q VLAN tagging; IEEE 802.1p Prioritization; IEEE 802.1ad QinQ (Provider Bridges); IEEE 802.1w Rapid Spanning Tree Protocol (RSTP); IEEE 802.1AX / 802.3ad Link Aggregation; PPPoA to PPPOE conversion, and PPPoE Intermediate Agent; IETF RFC 2684 bridged encapsulation; IETF RFC 4562 MAC-Forced Forwarding; SNMP V2c and SNMPv3; Secured management access as per HTTPS and SSHv2 |
Power Dissipation | Maximum operating condition 72.2 Watts (assumes 48 modems trained at Profile 17a); Heat dissipation: 246.2 BTU/Hour |
Power Options | -48vDC provided by E7-2 chassis |
Operating Environment | Temperature: -40° C to +70° C (-40° F to +158° F); Humidity: 10 to 95% (non-condensing) |
Storage Environment | Temperature: -40°C to +85°C (-40°F to +185° F); Humidity: 5 to 95% (non-condensing) |
Compliance | UL-60950, Standard for Safety, Issue 1, April 1, 2003; FCC 47 CFR (ICES-003) Part 15 Class A; NEBS Level 1 and NEBS Level 3; GR-1089-CORE Sect. 7, Electrical Safety; GR-3028-CORE Thermal Management in COs; GR-63-CORE Physical Protection, Issue 4 |
Third Party Modem Interoperability
Calix continues to test VDSL2 and ADSL2+ modems against different DSL Service Platforms supported. These modems must be commercially available and candidates for service deployment by Calix customers. Extensive rate/reach and data throughput performance testing is performed against all modems. Qualification testing is conducted for physical layer, HIS/data, as well as IPTV/Video service performance. Customer Advisory Bulletins (CAB) documents are available from Calix summarizing completed testing; new versions of the document will provide updates to tests that are in progress. Please refer to up-to-date CABs from Calix for the latest list of qualified and supported modems.
Ordering Information
Calix E7 Line Cards
- 100-03882: E7-2 VDSL2-48D r2 card; 48x VDSL2 Data-only ports, 2x 1GE/2.5GE SFP, 2x 1GE/10GE SFP+
Calix Optical and Copper Pluggable Modules
Calix offers a full suite of optical and copper modules for E7 line cards.
- SFP+: 10GE optical Small Form-factor Pluggable modules.
- Copper cable assemblies are supported in SFP and SFP+ ports at 1GE, 2.5GE and 10GE data rates.
- SFP: 1GE optical modules may also be used in SFP+ ports at a 1Gpbs rate.
Notes: For GPON OIM, 10GE XFP, 10GE SFP+, and 2.5GE pluggable transceivers, only modules purchased directly from Calix are supported.