Owner's Manual for neptronic models including: LM060NW-250214, LM060W Actuator, LM060W, Actuator
• FD5-T 5000 Ohms feedback potentiometer (optional). • AC2-T adjustable auxiliary switch (optional). • Stroke limiting device (SLD) (optional). Models. Features.
File Info : application/pdf, 2 Pages, 371.79KB
DocumentDocumentLM060W Actuator Specification and Installation Instructions Models LM060W Actuator: 140 in.lb. (16 Nm) with fail safe Features · IP 65 (Nema 4 protection with Rain Hood enclosure) · Mounts easily on round and square shafts · Dust and waterproof clutch for manual adjustment · Supplied with cable (pigtail) · Maintenance-free · Position indicator · FD5-T 5000 Ohms feedback potentiometer (optional) · AC2-T adjustable auxiliary switch (optional) · Stroke limiting device (SLD) (optional) · Fail safe by Enerdrive System LM060W Actuator Description LM060W Actuator Torque Motor Type Running Time (for 90° Rotation) Fail Safe (Enerdrive) Fail Safe Runtime (0° to 90°) Capacitor Charge Time on / Power-up Power Consumption Overload Protection Power Supply Transformer Requirements Cable Impedance (Input) Control Signals Feedback Signals Angle of Rotation Direction of Rotation Noise Produced Ingress Protection Operating Temperature Storage Temperature Relative Humidity Weight Purpose and Action of Control Construction of Control Pollution Degree Impulse Voltage Quality Management System 140 in.lb. [16 Nm] at rated voltage Brushless motor 60 to 85 seconds torque dependent Yes 85 seconds torque dependent 9 seconds 27VA Peak, 8VA (during operation) Electronic throughout, 0° to 90° rotation 22 to 26 Vac | 28 to 32 Vdc | 50/60Hz Class 2; min. 27VA 6-wire plenum cable (18AWG), 3ft (1m) long 100k ohms 2-10Vdc (default) or 4-20mA (with 500 ohm resistor between wires 1 and 3) 2-10Vdc (with 500 ohm resistor between wires 1 and 6) or 4-20mA (default) 0° to 90°, mechanically adjustable with SLD (optional) (default: 90° stroke) Reversible, CW: Clockwise, CCW: Counter Clockwise (default: CW) 45 dB(A) IP 65 (For outside applications, use RH7 or RH11 Rain Hood enclosure) -22°F to +122°F [-30°C to +50°C] -22°F to +122°F [-30°C to +50°C] 5 to 95% non-condensing 4.5 lb. [2kg] Type 1 Operating Control, Electric Actuator Independently Mounted 2 330V ISO 9001:2015 Certification Complies to standards: UL 60730-1 & UL 60730-2-14, CSA E60730-1 & CSA E60730-2-14 Complies to Low Voltage Directive & Electromagnetic Compatibility Directive Complies to Electrical Equipment (Safety) Regulations & Electromagnetic Compatibility Regulations WARNING: Risk of mechanical failure. Do NOT press clutch when actuator is in operation. LM060NW-250214 neptronic.com | 514-333-1433 | contact@neptronic.com Dimensions Wiring LM060W Actuator Specification and Installation Instructions A = 5.20" (132mm) B = 1.33" (34mm) C = 9.75" (248mm) D = 4" (102mm) Auto-Stroke The auto-stroke is activated everytime the actuator is powered on. The actuator searches for its 0° position and goes towards it, then goes to its 90° position and finally returns to its setpoint. Rotation Direction Selection Rotation Clockwise Rotation Counter-Clockwise Leave cable #4 (Direction selection) open Connect cable #4 (Direction selection) to cable #1 (Common VAC) Failsafe Direction Selection Failsafe return to 0° Leave cable#5 (Direction selection) open Failsafe return to 90° Connect cable #5 (Direction selection) to cable #1 (Common 0 VAC) Recycling at end of life: please return this product to your Neptronic local distributor for recycling. If you need to find the nearest Neptronic authorized distributor, please consult www.neptronic.com. neptronic.com | 514-333-1433 | contact@neptronic.com