Safety Information
Warnings
- Please read and understand this entire manual before using this product.
- To avoid electric shock, never test continuity on a live circuit.
- Applying voltage to the tester will damage the tester.
Battery Replacement
- Carefully unscrew the battery cap at the rear of the tester.
- Replace batteries with one AAA 1.5V battery. Observe polarity.
- Screw the cover onto the tester until it feels tight. Do not use excessive force.
- Verify operation by using the tester within the defined detection range.
Visual Description: Illustration of the Kobalt ET-22 Continuity Tester, a pen-shaped device with a pointed test tip at one end, a clear indicator light near the tip, a pocket clip on the side, and a screw-on battery cap at the rear. A diagram illustrates battery replacement steps: unscrewing the rear cap, inserting a AAA 1.5V battery with correct polarity, and re-screwing the cap securely.
Product Compliance
[CE certification] [RoHS compliant]
Users of this product are cautioned not to make modifications or changes. Doing so may void the compliance of this product with applicable laws and regulatory requirements and may result in the loss of the user's authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
"CAUTION: Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment."
Manufacturer/Distributor: Lowe's Home Centers LLC, 1000 Lowe's Blvd., Mooresville, NC 28117, 1-888-3KOBALT (1-888-356-2258).
Product Specifications
| General Specifications | Details |
|---|---|
| Battery | AAA 1.5V battery |
| Operating Environment | 32°F to 104°F (0°C to 40°C) at <80% relative humidity |
| Storage Environment | 14°F to 140°F (-10°C to 60°C) at <80% relative humidity |
| Operating Altitude | 7000ft (2000m) maximum |
| Net Weight | Approx. 0.08lb (36g) |
| Dimensions | Approx. 5.1 x 0.8 x 0.6 in (130 x 21 x 16 mm) |
Care and Maintenance
- Keep the meter dry. If it gets wet, wipe it off.
- Keep the meter clean. Wipe dirt with a soft cloth dampened with water. Do not use chemicals, cleaning solvents, or detergents.
- Use and store the meter in normal temperatures. Temperature extremes can shorten the life of electronic parts and distort or melt plastic parts.
- Handle the meter gently and carefully. Dropping it can damage electronic parts or the case.
- Use only fresh batteries of the recommended size and type. Batteries must be inserted with the correct polarity. Remove old or weak batteries to prevent leaks and unit damage.
- Do not mix old and new batteries. Do not mix different types of batteries (e.g., alkaline, carbon-zinc, rechargeable). Non-rechargeable batteries are not to be recharged.
- If the meter is to be stored for a long period, remove batteries to prevent unit damage.
Troubleshooting
| Problem | Possible Cause | Corrective Action |
|---|---|---|
| Neon light no indication | Run out of battery | Replace battery |
Operating Instructions
- Requires one AAA 1.5V battery.
- Install battery before using.
- Remove rubber tip before using.
Visual Description: Diagram showing the Kobalt Continuity Tester connected to a light socket adapter, with the tester's tip inserted into the adapter.
Package Contents
Visual Description: Diagram showing package contents and parts:
- Part 1: Test tip
- Part 2: Light indicator
- Part 3: Pocket clip
- Part 4: Fuse
- Part 5: Test alligator clip
- Part 6: Rubber tip
- Also shown are the Kobalt tester, a wire, and a light socket adapter.
Warranty
Three-year warranty. Incidental or consequential damages are excluded from this warranty.