INVT ICA400-02/ICA413-02 Series 4G IoT Data Transmission Terminal Operation Manual

Change History

No.Change descriptionVersionRelease date
1First release.V1.0December 2021
2
  • Added three function descriptions (antenna gain, power consumption and heat dissipation method) in section 1.2 Product specifications.
  • Added product weight data in section 2.3 Outline dimensions and weight.
  • Updated all operation descriptions and interface diagrams in chapter 3 Quick startup
V1.1September 2024

1 Product Overview

The INVT ICA400-02/ICA413-02 series IoT data transmission terminal is a 4G wireless data terminal for the Internet of Things (IoT). It is designed for RS485 or Ethernet communication, collecting device data via ModbusTCP protocol from RS485 or RJ45 interfaces. It provides wireless long-distance data transmission through public operator networks, meeting the stability and reliability requirements of industrial applications. The product features an industrial-grade 32-bit communication processor and wireless module, with an embedded real-time operating system, enabling PLCs and other devices to upload data to the cloud via RS485/RJ45 Ethernet interfaces.

1.1 Product Features

  1. Standard set-up for easy operation
    • Provides standard RS485 interfaces for direct connection to serial devices for data acquisition.
    • Provides standard RJ45 interfaces for direct connection to network devices for data acquisition (ICA413-02 model).
    • Intelligent data terminal that enters the data transmission state upon power-on.
    • Adopts standard rail installation.
    • Includes powerful center management software for device management (optional).
    • Offers a convenient system configuration and maintenance interface.
  2. Powerful functions
    • Supports remote wireless software upgrade and remote policy configuration via OTA.
    • Supports cloud-platform management for devices, facilitating remote management and device intelligence.
    • Embedded with standard TCP/IP protocol stacks, supporting multiple transmission protocols.
    • Supports APN.
    • Can directly connect to serial devices, supporting up to 40 groups of Modbus register collection for terminal devices.
    • Supports configuration of Modbus query address and collection period to upload only changed data, saving traffic.
    • Supports 4G base station positioning.
    • Supports SIM cards (optional).
    • Supports GPS positioning to obtain device positions accurately (optional).

1.2 Product Specifications

FunctionDescription
Supported networkChina(CN) version: LTE FDD: Band 1/3/5/8, LTE TDD: Band 34/39/40/41, GSM: 900/1800MHz
Europe(EU) version: LTE FDD: Band 1/3/7/8/20/28, GSM: 900/1800MHz
Latin America(LA) version: LTE FDD: Band 1/2/3/4/5/7/8/28/66, GSM: 900/1800MHz
Supported interfaces1 RS485 interface, 1 standard RJ45 interface (ICA413-02 model), 1 SMA 4G antenna interface, an optional SMA GPS antenna, 1 spring-loaded SIM card socket (medium card)
IndicatorPower indicator, network status indicator, running status indicator
Communication protocolModbus RTU/Modbus TCP protocol, IoT MQTT communication protocol, PPP dialing protocol, FTP transfer protocol
Theoretical bandwidthLTE FDD Rel.13: 10Mbps DL/5Mbps UL, LTE TDD Rel.13: 8.2Mbps DL/3.4Mbps UL, GPRS: 85.6Kbps DL/85.6Kbps UL
Antenna gain2.2dBi
Power supplyDC10-25V
Power consumptionICA400-02 series: Average power: 40mA@24V, maximum power: 500mA@24V.
ICA413-02 series: Average power: 50mA@24V, maximum power: 500mA@24V.
Temperature range-25 to +60°C
ShellWith shell, ingress protection (IP) rating IP20
Installation methodRail-mounted
Heat dissipation methodNatural heat dissipation

1.3 Model Instruction

The model name illustration for INVT ICA series data transmission terminals follows the pattern: ICA***-***-**.

SymbolDescriptionContents
Product series abbreviationICA: Internet Communication Adapter
Wireless communication mode0: Do not support wireless communication, 1: WIFI, 2: GPRS, 3: 3G, 4: 4G, 5: 5G
Wire communication mode0: Do not support wire communication, 1: Ethernet
Local data collection mode0: RS485, 1: Ethernet, 2: CAN, 3: RS485+Ethernet, 4: RS485+CAN, 5: Ethernet+CAN, 6: RS485+Ethernet+CAN, 7: RS485+Ethernet+VPN
SIM card type0: Plug-in card (Standard, default), 1: Embedded SIM card
IP rating0: IP00 (without shell), 1: IP20 (wall-mounted shell), 2: IP20 (rail-mounted shell), 6: IP65 (direct-insert shell)
Special functionG: with GPS, U: with USB flash disk, A: supports audio, V: supports video. (This bit is omitted for standard configuration.)
Voltage type5: 4.5-6V. (The voltage for standard configuration is 10V-30V, so this bit is omitted for standard configuration.)
International versionCN: China version, EU: Europe version, LA: Americas version. (This bit is omitted for WIFI products.)

1.4 Port Instruction

Port identifierPort description
24VPower supply +
GNDPower supply -
485+485A
485-485B
4GGPRS antenna
GPSGPS antenna (optional)
EthernetRJ45 interface (applicable to ICA413-02 only)
SIMSIM card
WAN↔LANFunction selection switch. The selection before power-up is valid. When WAN is selected, the network port is upstream and is used to connect to the network for data upload. When LAN is selected, the network port is downstream and is used to connect to the device for ModbusTCP data acquisition (only for ICA413-02 models).

1.5 Indicator Instruction

Indicator identifierDescription
NET4G network indicator:
  • Flash slowly (ON: 600ms; OFF: 600ms): No SIM card/Network registration in progress/Registration failed.
  • Flash quickly (ON: 75ms; OFF: 75ms): Data link established
RUNRun indicator:
  • Flash slowly (ON: 1s; OFF: 1s): RS485 communication is abnormal
  • Flash quickly (ON: 100ms; OFF: 100ms): RS485 communication is normal
ON or OFF: System exceptions
POWERPower supply indicator

2 Installation

2.1 Overview

The ICA series 4G IoT data transmission terminal must be installed properly to achieve its designed function. Installation should generally be done under the guidance of certified and qualified engineers. Note: Do not conduct installation with the power on.

2.2 Unpacking Inspection

Before unpacking, check if the package is in good condition and its product information matches the order. Packing materials should be well maintained for future transshipment. For any questions, please contact the supplier.

DeliverablesQtyRemark
4G data transmission terminal1
4G antenna1Applicable only to models using an external antenna
GPS antenna1Optional
SIM card1Applicable to models of China(CN) version
PIN terminal14PIN terminal

2.3 Outline Dimensions and Weight

The outline dimensions of the IP20 model are as follows (unit: mm):

The net weight of the ICA413 product is 97.1g, and the gross weight is 264g. The net weight of the ICA400 product is 90.7g, and the gross weight is 258.7g.

Diagram Description: Figure 2-1 shows the product dimensions for the ICA413-02, with a height of 122.6 mm, width of 55.7 mm, and depth of 51.7 mm. Figure 2-2 shows the product dimensions for the ICA400-02, with similar dimensions.

3 Quick Startup

3.1 Operation Description

Equipment required: Networked computer, 4G data transmission terminal, IoT SIM card.

Procedure:

  1. Open the flip cover at the front and insert the SIM card into the slot.
  2. Record the device ID and 6-digit key from the label and add them to the IoT monitoring system.
  3. Wire the product based on the port description (ICA413 models have the option to connect to a network cable).
  4. Connect to the 4G antenna and GPS antenna (optional).
  5. Power on and start the 4G data transmission terminal.
  6. If the yellow NET indicator flashes with an interval of 75ms, the expansion card is network ready and the data transmission starts.
  7. Go to the real-time monitoring interface to review relevant information in the IoT monitoring system.

3.2 Monitoring Platform Operation Instructions

You can monitor relevant devices through the following three methods. For information on how to obtain the account and password, refer to section 3.3 Monitoring Platform Account.

  1. Host controller software: IWOstudio
  2. Web: IWoscene industrial IoT application platform
  3. Mobile: INVT Cloud APP

3.2.1 IWOstudio Monitoring Equipment

  1. Download IWOstudio from the official website (www.invt.com), install, and then open it.
  2. Screenshot Description: The IWOstudio login screen is displayed, featuring fields for User and Password, and a 'Login' button.
  3. Screenshot Description: After logging in, the IWOstudio network configuration interface is shown. For account information, refer to section 3.3 Monitoring Platform Account.
  4. Screenshot Description: The IWOstudio interface displays device management options. To add a device type, click 'New' followed by 'New device type' in the lower left corner. If a device type already exists, proceed to step 5.
  5. Screenshot Description: A dialog box appears prompting to enter the 'Type name' for the new device. Click 'OK' to complete the creation. A 'Successfully created' prompt indicates completion.
  6. Screenshot Description: Click 'New' followed by 'New device' in the lower left corner of the IWOstudio interface.
  7. Screenshot Description: A dialog box prompts for 'Adapter ID', 'Adapter key', 'Device name', and 'Device type'. Enter the required information and click 'OK' to complete the process. Note: Adapter ID is the S/N code of the IoT terminal, and Adapter key is the six-digit number found below the QR code next to the S/N code.
  8. Screenshot Description: After adding the device, click on the device and then click 'New' to add parameters.
  9. Screenshot Description: A 'New parameter' dialog box appears. Enter the 'Parameter name', select 'Communication type', 'Parameter type', and 'Parameter address' (Modbus address of the register). Fill in other information as needed and click 'OK'. A 'Successfully created' prompt indicates completion.
  10. Screenshot Description: The 'Communication type management' dialog shows communication settings. Click to view, modify, or create new settings. The default is 485 communication with specific baud rate, data bits, stop bit, and parity. Click 'Edit' to modify. Additional communication parameters can be created. Note: Ensure the communication parameters correspond to the device for successful communication.
  11. Screenshot Description: After creating parameters, click 'Distribute'.
  12. Screenshot Description: Once successfully distributed, online monitoring can commence.

3.2.2 Web Monitoring Device

  1. Open a Google Browser, enter iot.invt.com in the address bar, and press Enter to visit the login page of the industrial IoT application platform. Enter the account number and password to log in. Note: For account information, refer to section 3.3 Monitoring Platform Account.
  2. Screenshot Description: After successful login, the INVT industrial IoT application platform homepage is displayed. In the 'Add devices quickly' section, enter the adapter number, secret key, and device name. Select the device type according to the monitoring type, and choose ICA400/413 as the adapter type (default communication is 485). Click 'Submit' after confirming the input. A 'Added successfully' prompt indicates the device has been added. Note: The adapter code is the S/N code of the IoT terminal, and the adapter secret key is the six-digit number below the QR code next to the S/N code.
  3. Screenshot Description: Enter the adapter code into the search box on the homepage. Click the device to access its monitoring page and check its status. The interface shows device details, network state, and monitoring parameters.

3.2.3 Monitoring the Device via APP

  1. Download and install the INVT Cloud APP on your mobile device. (Search for 'INVT' in Tencent MyApp Store or Google Play for iOS systems).
  2. Open the INVT Cloud APP, enter the account and password to log in. On the homepage, click the '+' icon in the upper-right corner. Enter the 'Adapter code', 'Secret key', and 'Device name', select the 'Device type', and click 'Submit' to complete the device addition. Note: For account information, refer to section 3.3 Monitoring Platform Account.
  3. Screenshot Description: In the search bar, enter the adapter code to search. Click the device to enter its monitoring page and monitor its status. The interface displays device details, parameters, and operational status.

3.3 Monitoring Platform Account

You can register a monitoring platform account through the Web or APP. The same account and password can be used across all three monitoring platforms.

3.3.1 Web Registration

  1. Enter: iot.invt.com in the address bar of Google Browser and press Enter to visit the login page of the industrial IoT application platform.
  2. Click 'Registered'.
  3. Screenshot Description: Fill in the 'Company name', 'User name', 'Password', and confirm the password. Enter your 'Mobile number', click 'Verification code', and input the code received via SMS. Enter the 'Invitation code' (if no higher-level user exists, use 'dbf20a' as the INVT administrator invitation code). Review and accept the User Privacy Agreement, then click 'Register'. A notification will be sent via SMS upon approval.

3.3.2 APP Registration

  1. Download and install the INVT Cloud APP on your mobile device. (Search for 'INVT' in Tencent MyApp Store or Google Play for iOS systems).
  2. Open the INVT Cloud APP and click 'Registered'.
  3. Screenshot Description: Fill in the 'Company name', 'User name', 'Password', and confirm the password. Enter your 'Mobile number', click 'Verification code', and input the code received via SMS. Enter the 'Invitation code' (if no higher-level user exists, use 'dbf20a' as the INVT administrator invitation code). Review and accept the User Privacy Agreement, then click 'Register'. A notification will be sent via SMS upon approval.

3.4 FAQs

  1. Question: After powering on, the power indicator does not flash or light up.
    Answer: Check if the power supply voltage polarity is reversed, and if the input voltage 24V and GND are consistent with the silkprint on the casing.
  2. Question: After power on for three minutes, the network status indicator flashes quickly at a frequency of 75ms, and no data is displayed on the web page.
    Answer:
    • The expansion card with a SIM card may not be installed properly. Power off and re-install it for good connection.
    • Move the antenna of the IoT transmission terminal to a location with a good signal.
    • Ensure the SIM card is activated and has remaining balance.
    • Contact the manufacturer to check if the device ID is registered.
  3. Question: Data uploading does not match the web page display.
    Answer:
    • Re-power on and upload all data again.
    • Check if the order and device type are matching. If not, contact the manufacturer.
  4. Question: The indicator flashes normally, but the web system displays no data.
    Answer: Check if the communication cable between the Modbus terminal device and the IoT transmission terminal is well connected.
  5. Question: In the web system, only data content can be displayed, and commands cannot be issued.
    Answer: Check if the signal enabling switch of the Modbus terminal device is turned on.
  6. Question: The network status light stays off after the ICA413-02 model is powered on.
    Answer: Check the WAN↔LAN switch. 4G network is only available when the switch is turned to LAN.
  7. Question: How to use the function selection switch on the ICA413-02 model.
    Answer: The ICA413-02 model has a function selection switch. When set to WAN, the network port connects to a router via a network cable, and other devices connect via RS485. When set to LAN, the terminal connects to the network via 4G and other devices connect via RS485 or network cable.
  8. Question: What happens if two devices are connected to the ICA413-02 model at the same time when the network port is downstream?
    Answer: If devices are connected to both RS485 and network ports, only data from the network port will be collected.

Company Information

The products are owned by Shenzhen INVT Electric Co., Ltd. Two companies are commissioned to manufacture: Shenzhen INVT Electric Co., Ltd. (origin code: 01) and INVT Power Electronics (Suzhou) Co., Ltd. (origin code: 06).

Shenzhen INVT Electric Co., Ltd.
Address: INVT Guangming Technology Building, Songbai Road, Matian, Guangming District, Shenzhen, China

INVT Power Electronics (Suzhou) Co., Ltd.
Address: No. 1 Kunlun Mountain Road, Science & Technology Town, Gaoxin District, Suzhou, Jiangsu, China

Service line: 86-755-23535967
E-mail: overseas@invt.com.cn
Website: www.invt.com

Product Categories: Industrial Automation (HMI, PLC, VFD, Servo System, Elevator Intelligent Control System, Rail Transit Traction System), Energy & Power (UPS, DCIM, Solar Inverter, SVG, New Energy Vehicle Powertrain System, New Energy Vehicle Charging System, New Energy Vehicle Motor).

Copyright © INVT. Manual information may be subject to change without prior notice. 202409 (V1.1)

Models: ICA400-02, ICA400-02 4G IoT Data Transmission Terminal, 4G IoT Data Transmission Terminal, Data Transmission Terminal, Terminal

File Info : application/pdf, 25 Pages, 9.65MB

PDF preview unavailable. Download the PDF instead.

ICA400-02 ICA413-02 Seires 4G IoT Data Transmissioin Terminal ManualV1.1

References

Microsoft Word 2010

Related Documents

Preview INVT ICA417 Series 4G IoT Data Transmission Terminal Operation Manual
This operation manual provides comprehensive details on the INVT ICA417 Series 4G IoT Data Transmission Terminal. It covers product features, specifications, installation procedures, operational guides for IoT monitoring, VPN pass-through, virtual serial port pass-through, and frequently asked questions (FAQs).
Preview INVT TBox Series Industrial Internet Data Transmission Terminal User Manual
This user manual provides comprehensive instructions for the INVT TBox Series Industrial Internet Data Transmission Terminal, covering product overview, specifications, installation, quick startup procedures, network configuration, VPN pass-through, virtual serial port pass-through, and FAQs.
Preview INVT ICA417 Series 4G IoT Data Transmission Terminal Operation Manual
This operation manual provides detailed instructions for the INVT ICA417 Series 4G IoT Data Transmission Terminal, covering product overview, specifications, installation, quick startup, monitoring platform operations, VPN pass-through configuration, virtual serial port pass-through configuration, and FAQs.
Preview INVT VS-Q Series HMI Product Manual and Specifications
Detailed product manual for the INVT VS-Q Series Human-Machine Interface (HMI) devices, covering technical specifications, features, dimensions, and module options for industrial automation applications.
Preview INVT EC-TX803 PROFIBUS-DP Communication Expansion Module User Manual
User manual for the INVT EC-TX803 PROFIBUS-DP communication expansion module, detailing specifications, installation, wiring, and commissioning for use with GD880 series VFD control boxes. Includes technical data, component descriptions, and operational guidance.
Preview INVT TS600 Series Intelligent PLC Catalog
Discover the INVT TS600 Series Intelligent PLC, a high-performance industrial automation controller offering advanced motion control, easy connectivity, scalability, and cloud integration. Learn about its features, specifications, and ordering details from Shenzhen INVT Electric Co., Ltd.
Preview INVT RS-485 Repeater EC-IRS485-HUB Quick Start Guide
Quick start guide for the INVT RS-485 Repeater (Model: EC-IRS485-HUB), detailing wiring diagrams, interface definitions, and installation dimensions for reliable RS-485 bus communication up to 115200 Kbps.
Preview Goodrive270 Series VFD for Fan and Pump - INVT
Discover the INVT Goodrive270 Series Variable Frequency Drive (VFD) designed for fan and pump applications. This document details product features, technical specifications, model selection, installation, and safety information.