LaserLight3™ ConnexLink™ Wireless Radio Installation
The ConnexLink Wireless Radio kit (PN 212753) allows communication from a LaserLight3 to a device with the matching radio (such as an indicator or remote display).
? Manuals and additional resources are available from the Rice Lake Weighing Systems website at www.ricelake.com. Warranty information can be found on the website at www.ricelake.com/warranties.
? For more information about LaserLight3, see LaserLight3 Large Display Indicator Technical Manual (PN 213589) or LaserLight3 Remote Display Technical Manual (PN 214748). ConnexLink documentation and resources can be found at www.lairdconnect.com.
⚠️ CAUTION: The LaserLight3 does not have a power switch. Before working with the unit, ensure the power cord is disconnected from the power outlet.
Parts List
Item | Part No. | Description | Qty |
---|---|---|---|
1 | 129662 | RF Pair Transceivers | 1 |
N/A | Antenna (Included with 129662) | 1 | |
166240 | Antenna Extension Cable | 1 | |
180683 | ConnexLink Transceiver to Display Cable | 1 | |
214713 | LaserLight3 ConnexLink Power Cable | 1 | |
225477 | 3/8 Snap-In Adhesive Back | 4 |
Table 1. ConnexLink Wireless Radio Kit Parts List
Installation
❗ IMPORTANT: Each ConnexLink radio is marked as Client or Server. Install the server type in indicators and the client type in remote displays.
Figure 1. ConnexLink Type Information
A table showing the relationship between LaserLight3 Type/Operating Mode (Indicator, Remote Display) and the ConnexLink Type (Server, Client) and the Paired ConnexLink (Client, Server).
Communication Type
Step 1: Attach Adhesive Feet
To attach adhesive feet to ConnexLink, align adhesive standoffs with ConnexLink mounting holes then push to snap into place.
Figure 2. Align and Attach Adhesive Standoffs to ConnexLink
An illustration depicting how to align the adhesive standoffs on the ConnexLink with the corresponding mounting holes on a surface, followed by pushing to secure.
Step 2: Disconnect Power
Disconnect LaserLight3 power cable from power outlet.
Step 3: Open Enclosure
Open the LaserLight3 enclosure.
❗ IMPORTANT: The ConnexLink power cable has a black (negative) wire and a black with white segments (positive) wire. Ensure power cables wires are connected to the power supply terminals with the same polarity.
Step 4: Connect Negative Power Wire
Attach the black negative power wire's spade to the free -V0 terminal on LaserLight3 power supply.
Step 5: Connect Positive Power Wire
Attach the black and white positive power wire's spade to the free +V0 terminal on LaserLight3 power supply.
Figure 3. Connect Power Cable Spade Connectors to LaserLight3 Power Supply
A diagram illustrating the connection of spade connectors from a black power cable (negative) and a black-and-white power cable (positive) to the -V0 and +V0 terminals, respectively, on the LaserLight3 power supply.
Step 6: Connect Power Cable to ConnexLink
Attach the power supply cable barrel connector to the ConnexLink 7-18VDC jack.
Figure 4. Connect Power Cable to ConnexLink 7-18VDC Jack
A diagram showing the barrel connector of the power supply cable being plugged into the 7-18VDC jack on the ConnexLink.
Step 7: Remove Antenna Hole Plug Hardware
Unscrew the antenna hole screw plug (bottom of enclosure) then collect the nut and washer (inside enclosure).
Figure 5. Remove Antenna Hole Plug Hardware
An exploded view showing the removal of a screw plug from the bottom enclosure of the LaserLight3, with an arrow indicating the collection of a nut and washer from inside.
Step 8: Remove Antenna Extension Cable Hardware
Remove nut and tooth washer from antenna extension cable.
Figure 6. Remove Retaining Hardware from Antenna Extension Cable
An illustration detailing the removal of a nut and a tooth washer from the threaded end of an antenna extension cable.
Step 9: Insert Antenna Cable
Inside enclosure, insert threaded end of antenna extension cable into antenna hole.
Figure 7. Insert Antenna Cable in Mounting Hole
A diagram showing the threaded end of the antenna extension cable being inserted into the designated antenna hole on the LaserLight3 enclosure from the inside.
Step 10: Install Antenna and Retaining Hardware
Install washer and nut (previously removed) on threaded end of extension cable protruding from bottom of enclosure. Turn antenna clockwise onto the antenna extension cable until tight.
Figure 8. Install Antenna and Retaining Hardware
An illustration demonstrating the process of installing the antenna onto the threaded end of the extension cable protruding from the enclosure, securing it with the previously removed nut and washer.
Step 11: Attach Antenna Extension Cable to ConnexLink
Turn the free end of the antenna extension cable clockwise onto the antenna jack on ConnexLink until tight.
Figure 9. Attach Antenna Extension Cable to ConnexLink
A diagram showing the free end of the antenna extension cable being screwed clockwise onto the antenna jack of the ConnexLink.
Step 12: Attach Transceiver Connector to RS-232 Port
Attach transceiver 6-pin connector to RS-232 port (J3) on LaserLight3 CPU board.
Figure 10. Attach Transceiver 6-Pin Connector to RS-232 Port
An illustration showing the 6-pin connector of the transceiver cable being attached to the RS-232 port (labeled J3) on the LaserLight3 CPU board. This figure also includes a table detailing the J3 Pin Assignment for RS232-1 and RS232-2.
Pin | RS232-1 | RS232-2 |
---|---|---|
1 | GND | |
2 | RX1 | |
3 | TX1 | |
4 | GND | |
5 | RX2 | |
6 | TX2 |
Step 13: Connect Transceiver Cable to ConnexLink
Attach the transceiver cable 9-pin connector to the ConnexLink I/O port and finger tighten retaining screws.
Figure 11. Connect Transceiver Cable 9-Pin Connector to ConnexLink
A diagram illustrating the connection of the 9-pin connector of the transceiver cable to the ConnexLink I/O port, with retaining screws being finger-tightened.
Step 14: Clean Mount Surface
Clean mount surface with Isopropyl Alcohol, and let dry.
Step 15: Position and Attach ConnexLink
Peel protective backing off adhesive standoffs and position ConnexLink with power jack at top (vertically) in left side of LaserLight3 enclosure.
❗ IMPORTANT: Ensure ConnexLink position will not obstruct enclosure door operation or make contact with circuit boards.
Apply firm pressure to adhesive pads for 30 seconds.
Figure 12. Attach ConnexLInk with Adhesive Standoffs to Enclosure
An illustration showing the ConnexLink unit, mounted using its adhesive standoffs, positioned vertically with the power jack at the top on the left side of the LaserLight3 enclosure.
Serial Configuration
After hardware installation, LaserLight3 software must be configured to communicate from its RS-232 port with the ConnexLink. In order to function correctly, the Baud and Bits parameters in the LaserLight3 require setup.
? By default LaserLight3 is configured with the required parameters to operate the ConnexLink. Ensure that the following settings are configured. If LaserLight3 default serial communication configuration has been altered, the system will not function. For more information about LaserLight3, see LaserLight3 Large-Display Weight Indicator Technical Manual (PN 213589) or LaserLight3 Remote Display Technical Manual (PN 214748).
Figure 13. Baud/Bits Parameter Menu Path
Two diagrams illustrating the menu navigation paths on the LaserLight3 for configuring serial communication parameters like Baud, Bits, and Stop Bits, for both the Large-Display Weight Indicator and the Remote Display models.
Step 1: Enable Setup Mode
Enable Setup mode by either pressing the MENU key (if a shunt is installed on J24 pins two and three) or opening the LaserLight3 and shorting J25 pins momentarily.
? Enabling Setup mode grants access to various LaserLight3 menus that are restricted in normal operation, including the Setup menu.
Figure 14. J24 Audit Jumper and J25 Setup Jumper
A diagram showing the location of the J24 Audit Jumper (with OFF/ON positions) and the J25 Setup Jumper (pins P1, P2, P3) on the LaserLight3 board.
Step 2: Navigate to Baud Settings
Perform one of the following:
- For LaserLight3 Remote Display, navigate to Setup ▶ Comm ▶ Serial ▶ RS232 1/2 ▶ Trigger ▶ Baud
- For LaserLight3 Large-Display Weight Indicator, navigate to Audit ▶ Setup ▶ Comm ▶ Serial ▶ RS232 1/2 ▶ Trigger ▶ Baud
Step 3: Set Baud Rate
Press [TARE]. The configured Baud parameter setting displays.
Press [UNITS] or [PRINT] repeatedly until 9600 is selected.
Step 4: Set Bits
Press [TARE]. The Bits parameter displays.
Press [TARE]. The configured Bits parameter setting displays.
Step 5: Set Stop Bits
Press [UNITS] or [PRINT] repeatedly until 8None is selected.
Press [TARE]. The Stop Bits parameter displays.
Step 6: Finalize Stop Bits
Press [TARE]. The configured Stop Bits parameter setting displays.
Press [UNITS] or [PRINT] repeatedly until 1 is selected.
Step 7: Exit Menu
Press [TARE].
Press [MENU] to exit the menu.
Specifications
This kit features a ConnexLink communication module. Visit www.lairdconnect.com to view the latest list of technical specifications on the communication module.
- Frequency Band: 902-928 MHz
- Modulation: FHSS FSK
- Interface: Standard: RS-232 (DB9 Male); ConnexLink Pro: RS-485 (6-Pin Terminal Block)
- Serial Interface Data Rate: Up to 115-200 kbps
- Output Power: 5 mW-1000 mW variable
- Input Power: 7-18 VDC
- Current Draw (at 12 VDC): 400 mA TXD, 40 mA RXD
- Channels: 32 selectable channels
- Security: 1-byte system ID, DES
- Sensitivity: -99dB at full RF data rate
- Range (line-of-sight): Up to 20 miles (32 km)
- Temperature: -40°F to 176°F (-40°C to 80°C)
- Humidity (non-condensing): 10% to 90%
- Weight: <6 oz (<170 g)
- Dimensions: 4.75 x 2.75 x 1.17 in (121 x 70 x 30 mm)
- Antenna Connector: Reverse polarity SMA jack (female)