LaserLight3™ ConnexLink™ Wireless Radio Installation

The ConnexLink Wireless Radio kit (PN 212753) allows communication from a LaserLight3 to a device with the matching radio (such as an indicator or remote display).

? Manuals and additional resources are available from the Rice Lake Weighing Systems website at www.ricelake.com. Warranty information can be found on the website at www.ricelake.com/warranties.

? For more information about LaserLight3, see LaserLight3 Large Display Indicator Technical Manual (PN 213589) or LaserLight3 Remote Display Technical Manual (PN 214748). ConnexLink documentation and resources can be found at www.lairdconnect.com.

⚠️ CAUTION: The LaserLight3 does not have a power switch. Before working with the unit, ensure the power cord is disconnected from the power outlet.

Parts List

Item Part No. Description Qty
1 129662 RF Pair Transceivers 1
N/A Antenna (Included with 129662) 1
166240 Antenna Extension Cable 1
180683 ConnexLink Transceiver to Display Cable 1
214713 LaserLight3 ConnexLink Power Cable 1
225477 3/8 Snap-In Adhesive Back 4

Table 1. ConnexLink Wireless Radio Kit Parts List

Installation

❗ IMPORTANT: Each ConnexLink radio is marked as Client or Server. Install the server type in indicators and the client type in remote displays.

Figure 1. ConnexLink Type Information

A table showing the relationship between LaserLight3 Type/Operating Mode (Indicator, Remote Display) and the ConnexLink Type (Server, Client) and the Paired ConnexLink (Client, Server).

Communication Type

Step 1: Attach Adhesive Feet

To attach adhesive feet to ConnexLink, align adhesive standoffs with ConnexLink mounting holes then push to snap into place.

Figure 2. Align and Attach Adhesive Standoffs to ConnexLink

An illustration depicting how to align the adhesive standoffs on the ConnexLink with the corresponding mounting holes on a surface, followed by pushing to secure.

Step 2: Disconnect Power

Disconnect LaserLight3 power cable from power outlet.

Step 3: Open Enclosure

Open the LaserLight3 enclosure.

❗ IMPORTANT: The ConnexLink power cable has a black (negative) wire and a black with white segments (positive) wire. Ensure power cables wires are connected to the power supply terminals with the same polarity.

Step 4: Connect Negative Power Wire

Attach the black negative power wire's spade to the free -V0 terminal on LaserLight3 power supply.

Step 5: Connect Positive Power Wire

Attach the black and white positive power wire's spade to the free +V0 terminal on LaserLight3 power supply.

Figure 3. Connect Power Cable Spade Connectors to LaserLight3 Power Supply

A diagram illustrating the connection of spade connectors from a black power cable (negative) and a black-and-white power cable (positive) to the -V0 and +V0 terminals, respectively, on the LaserLight3 power supply.

Step 6: Connect Power Cable to ConnexLink

Attach the power supply cable barrel connector to the ConnexLink 7-18VDC jack.

Figure 4. Connect Power Cable to ConnexLink 7-18VDC Jack

A diagram showing the barrel connector of the power supply cable being plugged into the 7-18VDC jack on the ConnexLink.

Step 7: Remove Antenna Hole Plug Hardware

Unscrew the antenna hole screw plug (bottom of enclosure) then collect the nut and washer (inside enclosure).

Figure 5. Remove Antenna Hole Plug Hardware

An exploded view showing the removal of a screw plug from the bottom enclosure of the LaserLight3, with an arrow indicating the collection of a nut and washer from inside.

Step 8: Remove Antenna Extension Cable Hardware

Remove nut and tooth washer from antenna extension cable.

Figure 6. Remove Retaining Hardware from Antenna Extension Cable

An illustration detailing the removal of a nut and a tooth washer from the threaded end of an antenna extension cable.

Step 9: Insert Antenna Cable

Inside enclosure, insert threaded end of antenna extension cable into antenna hole.

Figure 7. Insert Antenna Cable in Mounting Hole

A diagram showing the threaded end of the antenna extension cable being inserted into the designated antenna hole on the LaserLight3 enclosure from the inside.

Step 10: Install Antenna and Retaining Hardware

Install washer and nut (previously removed) on threaded end of extension cable protruding from bottom of enclosure. Turn antenna clockwise onto the antenna extension cable until tight.

Figure 8. Install Antenna and Retaining Hardware

An illustration demonstrating the process of installing the antenna onto the threaded end of the extension cable protruding from the enclosure, securing it with the previously removed nut and washer.

Step 11: Attach Antenna Extension Cable to ConnexLink

Turn the free end of the antenna extension cable clockwise onto the antenna jack on ConnexLink until tight.

Figure 9. Attach Antenna Extension Cable to ConnexLink

A diagram showing the free end of the antenna extension cable being screwed clockwise onto the antenna jack of the ConnexLink.

Step 12: Attach Transceiver Connector to RS-232 Port

Attach transceiver 6-pin connector to RS-232 port (J3) on LaserLight3 CPU board.

Figure 10. Attach Transceiver 6-Pin Connector to RS-232 Port

An illustration showing the 6-pin connector of the transceiver cable being attached to the RS-232 port (labeled J3) on the LaserLight3 CPU board. This figure also includes a table detailing the J3 Pin Assignment for RS232-1 and RS232-2.

Pin RS232-1 RS232-2
1 GND
2 RX1
3 TX1
4 GND
5 RX2
6 TX2

Step 13: Connect Transceiver Cable to ConnexLink

Attach the transceiver cable 9-pin connector to the ConnexLink I/O port and finger tighten retaining screws.

Figure 11. Connect Transceiver Cable 9-Pin Connector to ConnexLink

A diagram illustrating the connection of the 9-pin connector of the transceiver cable to the ConnexLink I/O port, with retaining screws being finger-tightened.

Step 14: Clean Mount Surface

Clean mount surface with Isopropyl Alcohol, and let dry.

Step 15: Position and Attach ConnexLink

Peel protective backing off adhesive standoffs and position ConnexLink with power jack at top (vertically) in left side of LaserLight3 enclosure.

❗ IMPORTANT: Ensure ConnexLink position will not obstruct enclosure door operation or make contact with circuit boards.

Apply firm pressure to adhesive pads for 30 seconds.

Figure 12. Attach ConnexLInk with Adhesive Standoffs to Enclosure

An illustration showing the ConnexLink unit, mounted using its adhesive standoffs, positioned vertically with the power jack at the top on the left side of the LaserLight3 enclosure.

Serial Configuration

After hardware installation, LaserLight3 software must be configured to communicate from its RS-232 port with the ConnexLink. In order to function correctly, the Baud and Bits parameters in the LaserLight3 require setup.

? By default LaserLight3 is configured with the required parameters to operate the ConnexLink. Ensure that the following settings are configured. If LaserLight3 default serial communication configuration has been altered, the system will not function. For more information about LaserLight3, see LaserLight3 Large-Display Weight Indicator Technical Manual (PN 213589) or LaserLight3 Remote Display Technical Manual (PN 214748).

Figure 13. Baud/Bits Parameter Menu Path

Two diagrams illustrating the menu navigation paths on the LaserLight3 for configuring serial communication parameters like Baud, Bits, and Stop Bits, for both the Large-Display Weight Indicator and the Remote Display models.

Step 1: Enable Setup Mode

Enable Setup mode by either pressing the MENU key (if a shunt is installed on J24 pins two and three) or opening the LaserLight3 and shorting J25 pins momentarily.

? Enabling Setup mode grants access to various LaserLight3 menus that are restricted in normal operation, including the Setup menu.

Figure 14. J24 Audit Jumper and J25 Setup Jumper

A diagram showing the location of the J24 Audit Jumper (with OFF/ON positions) and the J25 Setup Jumper (pins P1, P2, P3) on the LaserLight3 board.

Step 2: Navigate to Baud Settings

Perform one of the following:

Step 3: Set Baud Rate

Press [TARE]. The configured Baud parameter setting displays.

Press [UNITS] or [PRINT] repeatedly until 9600 is selected.

Step 4: Set Bits

Press [TARE]. The Bits parameter displays.

Press [TARE]. The configured Bits parameter setting displays.

Step 5: Set Stop Bits

Press [UNITS] or [PRINT] repeatedly until 8None is selected.

Press [TARE]. The Stop Bits parameter displays.

Step 6: Finalize Stop Bits

Press [TARE]. The configured Stop Bits parameter setting displays.

Press [UNITS] or [PRINT] repeatedly until 1 is selected.

Step 7: Exit Menu

Press [TARE].

Press [MENU] to exit the menu.

Specifications

This kit features a ConnexLink communication module. Visit www.lairdconnect.com to view the latest list of technical specifications on the communication module.

Rice Lake Weighing Systems • All Rights Reserved

Models: PN 212753, PN 212753 LaserLight3 ConnexLink Wireless Radio, LaserLight3 ConnexLink Wireless Radio, ConnexLink Wireless Radio, Wireless Radio, Radio

File Info : application/pdf, 8 Pages, 1.28MB

PDF preview unavailable. Download the PDF instead.

a 214716 ll3 connexlink enus revc

References

Related Documents

Preview Rice Lake MS200 and MS202 Monorail Scale Installation Manual
Comprehensive installation manual for Rice Lake MS200 and MS202 monorail scales, covering safety, installation procedures, replacement parts, and specifications. Includes details for portable and permanent models.
Preview iDimension® PWD Operation Manual - Static Dimensioning System
This operation manual provides a comprehensive guide to the iDimension® PWD Static Dimensioning System, covering its overview, operation, measurements, configuration, calibration, and troubleshooting. It details the system's components, including the 880 Panel Mount Indicator and SUMMIT® 3000 Floor Scale, and explains how to perform measurements using the touchscreen display and other triggering methods. Safety precautions and regulatory information are also included.
Preview Rice Lake 1280 Enterprise Series Dual Serial Interface Card Installation Guide
Step-by-step installation guide for the Rice Lake 1280 Enterprise Series Dual Serial Interface Card (PN 164685), enabling RS-232 or RS-485 communication. Includes parts lists, pin assignments, and specifications.
Preview Rice Lake Load Ranger 2.4 GHz RF Wireless Weigh Pad System Quick Start Guide
Quick start guide for setting up and pairing Rice Lake Load Ranger 2.4 GHz RF wireless wheel weigh pads with the Ai-1 indicator for accurate weight readings. Covers unpacking, pad setup, indicator pairing, and application configurations.
Preview 480/482 Legend Series Concurrent Fast/Slow Setpoint Batching Routine Guide
Guide to configuring and wiring the Rice Lake 480/482 Legend Series Indicator for a concurrent fast/slow setpoint batching routine, including setpoint configuration and wiring details.
Preview LaserLight3 Remote Display Operator Quick Reference Guide
Quick reference guide for the Rice Lake Weighing Systems LaserLight3 Remote Display, covering annunciators, keypad functions, menu navigation, and software operations like editing time and date.
Preview CW-90X Checkweigher Breather Vent Replacement Guide | Rice Lake Weighing Systems
Step-by-step instructions for replacing the breather vent on the Rice Lake Weighing Systems CW-90X Checkweigher. Includes tool list, part list, and important notes.
Preview Rice Lake 260-10-1 Bariatric Handrail Scale Operation Manual
Comprehensive operation manual for the Rice Lake 260-10-1 Bariatric Handrail Scale, detailing setup, assembly, operation, maintenance, troubleshooting, communication, and specifications. Includes guidance on using the optional height rod.