Product Description

A close-up photograph of the Aprilaire Digital Ventilation Controller. The device is rectangular with a light gray casing. A prominent digital display shows "40". Below the display is text "Minutes Per Hour". To the left of the display is a circular dial with markings from OFF to 60 Minutes Per Hour, with increments of 10, 20, 30, 40, 50, 60. A smaller dial pointer is at the "OFF" position. To the right of the display is a small circular indicator light labeled "Active Ventilation". Below the dial is a button labeled "Test Reset". The Aprilaire logo is visible at the bottom right of the device.

Principles of Operation

Today's houses are constructed using “Green” techniques and energy saving systems. These practices and innovations help reduce utility bills but can prevent the introduction of fresh air. Without ventilation, stale air and contaminants from cleaning, painting, and exhaust from attached garages can remain in the air for extended periods.

Your Aprilaire ventilation controller brings in fresh air and circulates it through your home around the clock to help reduce the stuffy effects of trapped stale air. The actual rate of ventilation is determined by the size of your home and the number of occupants. With this ventilation controller, you have a dependable way of automatically providing fresh air to your home.

The controller continuously monitors indoor humidity and outdoor temperature, operating according to timer settings adjusted to your preference, local codes, or the HVAC industry recognized ASHRAE 62.2-2010 guidelines.

The ventilation controller will not allow outside air to enter if it could potentially raise the indoor humidity to high levels. To prevent this, the controller has an upper limit of 55% RH when the outdoor temperature is above 50°F. It can also prevent ventilation in extreme high or low temperatures. Consult your installing contractor to enable or disable these limits.

? Please Note: Ventilation will not occur if the inlet is clogged with debris. Clean this regularly.

Setting Instructions

Your ventilation controller is installed in the return duct of your furnace or heat pump. The primary user-adjustable setting is the ventilation time per hour. For example, if the controller knob is set to 20 minutes, you will receive 20 minutes of ventilation every hour. Ventilation occurs during heating and cooling calls. If the heating or cooling system does not initiate ventilation, the controller will turn on the furnace blower to provide the set ventilation time.

A close-up of the circular dial on the Aprilaire Digital Ventilation Controller. It shows markings for OFF, 10, 20, 30, 40, 50, 60 Minutes Per Hour, and a TEST/RESET position. The dial pointer is shown set to approximately 20 minutes.
  • The dial is labeled in 10-minute increments but can be set to any estimated value within 5-minute accuracy. The installer will have pre-set this according to your home's size and number of occupants. If you feel more or less time is needed, turn the knob a maximum of 5 minutes either way. Allow ventilation at the new setting to operate for 24 hours before making further adjustments.
  • The TEST/RESET setting is used to check the device for proper installation. This setting will activate the controller for only 1 minute. Do not leave the knob at TEST/RESET.

Limited Warranty

Research Products Corporation warrants your Aprilaire® Digital Ventilation Controller to be free from defects in materials or workmanship for five (5) years from the date of installation.

Research Products Corporation's exclusive obligation under this warranty is to supply, without charge, a replacement for the Controller found to be defective within the five (5) year period, provided it is returned not later than thirty (30) days after the end of the five (5) year period to your original supplier or to Research Products Corporation, Madison, Wisconsin 53701, along with the installation date.

This warranty does not obligate Research Products Corporation for any labor costs and does not apply to defects in workmanship or materials furnished by your installer, as opposed to defects in the Controller itself.

Implied warranties of merchantability or fitness for a particular purpose are limited to the duration of the aforesaid five-year period.

Research Products Corporation's liability for incidental or consequential damages, other than damages for personal injuries, resulting from any breach of the implied warranties or this limited warranty is expressly excluded.

This limited warranty is void if defects result from failure to have this unit installed by a qualified heating and air conditioning contractor. If the limited warranty is void due to failure to use a qualified contractor, all disclaimers of implied warranties become effective upon installation.

Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages, so the above exclusions or limitations may not apply to you. This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.

Warranty Registration

? Visit us on-line at www.aprilaire.com to register your Aprilaire product. If you do not have on-line access, please mail a postcard with your name, address, phone number, product purchased, and date of purchase to: Research Products Corporation, P.O. BOX 1467, Madison, WI 53701.

Your Warranty Registration information will not be sold or shared outside of this company.

PDF preview unavailable. Download the PDF instead.

owner-manual-aprilaire-8120a-ventilation-controller Adobe PDF Library 9.9 Adobe InDesign CS5 (7.0.4)

Related Documents

Preview Aprilaire 8120A & 8126A Digital Ventilation Controller Owner's Manual
Owner's manual for the Aprilaire Model 8120A and 8126A Digital Ventilation Controller, including safety, operating instructions, and warranty information. Learn how to optimize your home's ventilation.
Preview Aprilaire 8120A & 8126A Digital Ventilation Controller Owner's Manual
Owner's manual for the Aprilaire Model 8120A and 8126A Digital Ventilation Controller, providing safety, operating instructions, and warranty information for optimal indoor air quality.
Preview Aprilaire 8120A/8126A Digital Ventilation Controller Installation & Safety Guide
Official installation and safety instructions for Aprilaire Model 8120A and 8126A Digital Ventilation Controllers. Covers mounting, wiring, mode settings, ventilation requirements, and troubleshooting for optimal home fresh air.
Preview Aprilaire 8120A & 8126A Digital Ventilation Controller: Safety & Installation Guide
Comprehensive safety and installation instructions for the Aprilaire 8120A and 8126A Digital Ventilation Controllers. Covers mounting, wiring, mode selection, ventilation requirements, system checkout, and troubleshooting for optimal home air quality.
Preview Aprilaire Model 8120 Ventilation Controller Owner's Manual
Comprehensive owner's manual for the Aprilaire Model 8120 Ventilation Controller, detailing its principle of operation, operating instructions for setting cycle and ventilation times, control limits based on outdoor temperature and indoor humidity, and warranty information.
Preview Aprilaire 8126A Ventilation System Specification Sheet and Operation Guide
Detailed specification sheet for the Aprilaire 8126A Ventilation System, covering product specifications, principle of operation, set of operation modes, and installation diagrams. Learn about controlling fresh air intake based on time, temperature, and humidity.
Preview Aprilaire Model 8120 Ventilation Controller Owner's Manual
Owner's manual for the Aprilaire Model 8120 Ventilation Controller, providing safety, operating instructions, and warranty information for efficient home ventilation.
Preview Aprilaire Model 8120X Digital Ventilation Controller Installation and Operation Manual
Comprehensive guide for installing and operating the Aprilaire Model 8120X Digital Ventilation Controller, covering setup, wiring, operational modes, and warranty information for residential HVAC systems.