XPR XP, XP-K, XPM RFID Keypads and Readers Installer's Manual
Installation, Configuration, and Technical Specifications
Product Overview and References
This manual provides installation and configuration details for the XPR XP, XP-K, and XPM series of RFID keypads and readers.
Available Models:
- XP Series: XP, XP-MF-W, XP-MF-W-X, XP-MF-RS, XP-MF-RS-X
- XP-K Series: XP-K, XP-K-MF-W, XP-K-MF-W-X, XP-K-MF-RS, XP-K-MF-RS-X
- XPM Series: XPM, XPM-MF-W, XPM-MF-W-X, XPM-MF-RS, XPM-MF-RS-X
Visual Description: The document displays images of the XP, XP-K, and XPM devices, showcasing their compact designs and keypad layouts. The XP and XP-K models are shown side-by-side, followed by the XPM model. Mounting diagrams illustrate the physical installation steps for XP & XP-K and XPM units.
Mounting and Installation
Ferrite Core Mounting
For optimal performance and to reduce electromagnetic interference (EMI), a ferrite core is included in the kit. To install, wrap the device wires around the ferrite core once (1 turn).
Visual Description: A diagram shows the process of wrapping wires around a ferrite core, emphasizing its role in reducing EMI.
Technical Features
Feature | Specification |
---|---|
Power Supply | 9 - 15 V DC |
Maximum Current Consumption (at 12V DC) | 100 mA |
Sound Indicator | Internal buzzer |
LED Indicators | RGB (Red, Green, Blue) |
Connector | Built-in USB-Type C connector for protocol selection, configuration, and firmware update |
Reading Distance | Up to 9cm for XP/XP-K, Up to 8cm for XPM |
Environmental Rating | Outdoor, IP65 |
Operating Temperature | -30°C to +70°C |
Operating Humidity | 0% - 95% relative humidity, non-condensing |
Mounting | Surface mount |
Dimensions (H x W x D) | XP & XP-K: 107 x 80 x 27 mm; XPM: 114 x 42 x 27 mm |
Impact Protection Rating | XP & XPM: IK 11; XP-K: IK 10 |
Visual Description: Diagrams illustrate the physical connections for various terminals (e.g., +12V, GND, RS-485 A/B, D0, D1, LG, LR, BUZZ) and indicate their functions for WS4 and Wiegand configurations. It also shows the location of LED indicators (Green Input, Red Input) and the USB-Type C connector.
Certifications
The product complies with:
- EMC directive 2014/30/EU
- Radio Equipment Directive 2014/53/EU
- RoHS2 directive 2011/65/EU and RoHS3 Directive 2015/863/EU
Environmental and Material Testing:
Test Type | Details |
---|---|
Corrosion Test (Saline Environments) | Complies with IEC 60068-2-11:2007. Conditions: 35°C / 95°F, 5% Salinity, 1.0-2.0 ml/80cm²/hour flowrate, 96 hours duration. |
Fire Resistance | Complies with UL94-VO. |
Housing Material Resistance | Tested for UV-light, water exposure/immersion. Model F1 (UL746C). |
Terminal Blocks and Dipswitch Configuration
This section details the terminal block assignments and dipswitch settings for configuring the devices.
Terminal Block Assignments
Terminal | Description | WS4 Configuration | Wiegand Configuration |
---|---|---|---|
A | RS-485 line | RS-485 A (+) | X |
B | RS-485 line | RS-485 B (-) | X |
D0 | Output | X | D0 |
D1 | Output | X | D1 |
LG | Input | X | Green LED Input |
LR | Input | X | Red LED Input |
BUZZ | Input | X | Buzzer Input |
+12V | Power Supply | ✔️ | ✔️ |
GND | Ground | ✔️ | ✔️ |
T | Tamper (Autoprotection) | (Tamper state is reported by RS-485) | ✔️ |
Visual Description: A diagram shows the layout of terminal connections on the device, including labels for Power Supply (+12V, GND), RS-485 Bus (A, B), Data Output (D0, D1), Input signals (LG, LR, BUZZ), and Tamper (T).
Dipswitch Settings
Dipswitches are used for reader address and RS-485 bus termination configuration.
SW 1: Reader Address Configuration
- Reader Address 0: Switch 1 OFF. Used for Doors 1.0 and 2.0, or one of two readers on a door.
- Reader Address 1: Switch 1 ON. Used for Doors 1.1 and 2.1, or the second of two readers on a door.
Visual Description: A diagram shows Dipswitch SW 1 with two positions (1 and 2). The text indicates that Switch 1 controls the reader address, with OFF for address 0 and ON for address 1.
SW 2: RS-485 120 OHM Termination
- Termination OFF: Switch 2 OFF. Use when the device is not at the end of the RS-485 bus.
- Termination ON: Switch 2 ON. Use when the device is at the end of the RS-485 bus.
Visual Description: A diagram shows Dipswitch SW 2 with two positions (1 and 2). The text indicates that Switch 2 controls the RS-485 bus termination, with OFF and ON settings.
Wiring and Cabling
Parameter | WS4 Configuration | Wiegand Configuration |
---|---|---|
Max Cable Length | 80 m | 150 m |
Recommended Cable Type | Multiconductor cable, 2 twisted pairs with shielding. | Untwisted, shielded, 0.22 mm² min. For distances > 20m, use larger diameter. |
Visual Description: Diagrams illustrate typical wiring setups for WS4 and Wiegand configurations, showing connections to terminals and the use of specific cable types.
Signalling and Status Indicators
The status of the reader is indicated by LEDs and communication status.
Status | Description | WS4 Configuration | Wiegand Configuration |
---|---|---|---|
Reader ON-LINE | Reader is in communication with controller. | Managed by Controller | Managed by Controller |
Reader OFF-LINE | Reader has lost communication with controller. | Red LED Blinks fast | Red LED Blinks fast (X) |
Visual Description: The document describes the meaning of "Reader ON-LINE" and "Reader OFF-LINE" statuses. For OFF-LINE status, it notes that the Red LED blinks fast, indicated by an 'X' in the Wiegand column.