ifm Fail-Safe Inductive 18mm Barrel Proximity Sensor
Contact: 1-800-633-0405 | AutomationDirect.com
Safety technology is crucial for safe human-machine interaction and forms a key part of safety systems for personnel and machinery. Inductive sensors offer advantages in many safety applications, enabling direct detection of metal and helping system designers meet various design challenges. Their non-contact nature eliminates physical wear, and a high protection rating ensures high uptime for machines and installations. These fail-safe sensors do not require a magnet or coded target; they detect metals and operate with an enable zone monitored for target position and dwell time.
Features
- Certification to EN 60947-5-3 for electromechanical control gear
- No special actuator required for electronic fail-safe sensors
- Series connection of sensors is possible
- Standard 18mm barrel housing
- OSSD output
ifm Fail-Safe Inductive 18mm Barrel Proximity Sensor Selection Guide
Part Number | Price | Housing Diameter | Housing Material | Enable Zone | Safe Switch-Off Distance | Mounting Type | IP Rating | SIL Level/ Performance Level | Safe State Position | Drawing |
---|---|---|---|---|---|---|---|---|---|---|
GG711S | $174.00 | 18mm [0.71 in] | Stainless steel | 1-8 mm [0.04-0.31 in] | 12mm [0.47 in] | Non-flush | IP65, IP67 | SIL 2 PLd | Target not present | |
GG712S | $174.00 | 18mm [0.71 in] | Brass plated with white bronze | 1-5 mm [0.04-0.20 in] | 7mm [0.28 in] | Flush | IP65, IP67 | SIL 2 PLd | Target not present | |
GG851S | $174.00 | 18mm [0.71 in] | Brass plated with white bronze | > 10mm [> 0.39 in] | < 5mm [< 0.20 in] | Flush | IP65, IP67 | SIL 2 PLd | Target present | |
GG854S | $135.00 | 18mm [0.71 in] | Brass plated with white bronze | > 11.5 mm [> 0.45 in] | < 6.5 mm [< 0.26 in] | Non-flush | IP65, IP67, IP68, IP69K* | SIL 2 PLd | Target present | |
GG855S | $135.00 | 18mm [0.71 in] | Brass plated with white bronze | > 7.5 mm [> 0.30 in] | < 4mm [< 0.16 in] | Flush | IP65, IP67, IP68, IP69K* | SIL 2 PLd | Target present |
*IP69K rating is applicable only when used with a properly installed IP69K cable, such as the EVTxxxx series.
Diagrams and Connections
GG71xS Sensor Diagram
Diagram illustrating the GG71xS sensor. It shows a cylindrical sensor with two indicator LEDs. Key features indicated by numbers are: 1 - Dual LED (signal yellow, power green), 2 - Close zone, 3 - Enable zone, 4 - Safe switch-off distance, 5 - Target.
GG85xS Sensor Diagram
Diagram illustrating the GG85xS sensor. It shows a cylindrical sensor with two indicator LEDs. Key features indicated by numbers are: 1 - Status LEDs, 2 - Close zone, 3 - Enable zone, 4 - Safe switch-off distance, 5 - Target.
M12 4-pin Male Connector
Diagram of an M12 4-pin male connector. It details the pinout and corresponding wire colors for connection: Pin 1 (Brown) is +24VDC, Pin 2 (White) is OSSD 1, Pin 3 (Blue) is 0VDC, and Pin 4 (Black) is OSSD 2. A note advises confirming specific color-to-pinout based on the cable used during installation.
ifm Fail-Safe Inductive 18mm Barrel Proximity Sensor Technical Specifications
Specification | GG711S | GG712S | GG851S | GG854S | GG855S |
---|---|---|---|---|---|
Category and PL Level (ISO 13849-1) | Category 2, PLd | Category 2, PLd | Category 2, PLd | Category 2, PLd | Category 2, PLd |
SIL Level (IEC 61508 / IEC 62061) | SIL 2 | SIL 2 | SIL 2 | SIL 2 | SIL 2 |
Mission Time | ≤ 175,200 hours if operated at ideal operating temperature; ≤ 87,600 hours if not operated at ideal operating temperature | ||||
PFH | 1.0 x 10-7 | 1.0 x 10-7 | 1.0 x 10-7 | 5 x 10-8 | 5 x 10-8 |
Mounting Type | Non-flush | Flush | Flush | Non-flush | Flush |
Enable Zone | 1-8 mm [0.04-0.31 in] | 1-5 mm [0.04-0.20 in] | >10mm [0.39 in] | > 11.5 mm [0.45 in] | > 7.5 mm [0.30 in] |
Safe Switch-Off Distance | 12mm [0.47 in] | 7mm [0.28 in] | < 5mm [0.20 in] | < 6.5 mm [0.26 in] | < 4mm [0.16 in] |
Safe State Position | Target not present | Target not present | Target present | Target present | Target present |
Output Type | Dual channel OSSD | ||||
Operating Voltage | 19.2-30 VDC | 19.2-30 VDC | 10-30 VDC | 8-32 VDC | 8-32 VDC |
Reverse Polarity Protection | Yes | ||||
Current Consumption | < 30mA | < 30mA | < 30mA | < 20mA | < 20mA |
Voltage Drop (Output) | 2.5V @ 30mA | ||||
Short-Circuit Protection (Output) | No | No | No | Yes | Yes |
Overload Protection (Output) | No | No | No | Yes | Yes |
Ideal Operating Temperature | 10 to 40°C [50 to 104°F] | 10 to 40°C [50 to 104°F] | 10 to 40°C [50 to 104°F] | -25 to 70°C [-13 to 158°F] | -25 to 70°C [-13 to 158°F] |
Operating Temperature Range (Note that operating temperature affects mission time) | -25 to 70°C [-13 to 158°F] | -25 to 70°C [-13 to 158°F] | -25 to 70°C [-13 to 158°F] | -40 to 85°C [-40 to 185°F] | -40 to 85°C [-40 to 185°F] |
Protection Degree (DIN 40050) | IP65, IP67 | IP65, IP67 | IP65, IP67 | IP65, IP67, IP68, IP69K* | IP65, IP67, IP68, IP69K* |
Indication/Switch Status | Operation (GREEN) LED, Signal (YELLOW) LED | Operation (GREEN) LED, Signal (YELLOW) LED | Operation (GREEN) LED, Signal (YELLOW) LED | Signal (YELLOW) LED | Signal (YELLOW) LED |
Housing Material | Stainless steel (316Ti) | Brass plated with white bronze | Brass plated with white bronze | Brass plated with white bronze | Brass plated with white bronze |
Sensing Face Material | PBT (Polybutylene terephthalate) | PBT (Polybutylene terephthalate) | PBT (Polybutylene terephthalate) | LCP (Liquid crystal polymer) | LCP (Liquid crystal polymer) |
Shock Resistance | Meets or exceeds IEC 60947-5-2 | Meets or exceeds IEC 60947-5-2 | Meets or exceeds IEC 60947-5-2 | Meets or exceeds IEC60068-2-27 Ea | Meets or exceeds IEC60068-2-27 Ea |
Vibration Resistance | Meets or exceeds IEC 60947-5-2 | Meets or exceeds IEC 60947-5-2 | Meets or exceeds IEC 60947-5-2 | Meets or exceeds IEC60068-2-6 Fc | Meets or exceeds IEC60068-2-6 Fc |
Tightening Torque | < 25 N•m | < 25 N•m | < 20 N•m | < 25 N•m | < 25 N•m |
Weight | 129.5 g [4.57 oz] | 133g [4.69 oz] | 163.5 g [5.77 oz] | 106.8 g [3.77 oz] | 109.2 g [3.85 oz] |
Connection | M12, A coded, 4-pin | ||||
Agency Approvals | CE, cULus, TÜV | CE, cULus, TÜV | CE, cULus, TÜV | CE, cULus, TÜV | CE, cULus, TÜV |
*IP69K rating is applicable only when used with a properly installed IP69K cable, such as the EVTxxxx series.
Important Safety Information
⚠️ Warning: Safety products sold by AutomationDirect are Safety components only. The purchaser/installer is solely responsible for the application of these components and ensuring all necessary steps have been taken to assure each application and use meets all performance and applicable safety requirements and/or local, national and/or international safety codes as required by the application. AutomationDirect cannot certify that our products, used solely or in conjunction with other AutomationDirect or other vendors' products, will assure safety for any application. Any person using or applying any products sold by AutomationDirect is responsible for learning the safety requirements for their individual application and applying them, and therefore assumes all risks, and accepts full and complete responsibility, for the selection and suitability of the product for their respective application.
AutomationDirect does not provide design or consulting services, and cannot advise whether any specific application or use of our products would ensure compliance with the safety requirements for any application.