⚠️ WARNING: BEFORE YOU BEGIN READ THESE INSTRUCTIONS COMPLETELY AND CAREFULLY.
- To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards, please read all warnings and instructions included with and on the fixture box and all fixture labels.
- Before installing, servicing, or performing routine maintenance on this equipment, follow these general precautions.
- Commercial installation, service and maintenance of luminaires should be performed by a qualified licensed electrician.
- For Residential installation: If you are unsure about the installation or maintenance of the luminaires, consult a qualified licensed electrician and check your local electrical code.
- Maintenance of the luminaires should be performed by person(s) familiar with the luminaires' construction and operation and any hazards involved. Regular fixture maintenance programs are recommended.
- This fixture is intended to be connected to a properly installed and grounded UL listed junction box.
- It will occasionally be necessary to clean the outside of the refractor/lens. Refractor/lens should be washed in a solution of warm water and any mild, non-abrasive household detergent, rinsed with clean water and wiped dry. Should optical assembly become dirty on the inside, wipe refractor/lens and clean in above manner, replacing damaged gaskets as necessary.
- DO NOT INSTALL DAMAGED PRODUCT! This luminaire has been properly packed so that no parts should have been damaged during transit. Inspect to confirm.
- Any part damaged or broken during or after assembly should be replaced.
- These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to meet in connection with installation, operation, or maintenance. Should further information be desired, or should particular problems arise which are not covered sufficiently for the purchaser's or owner's purposes, this matter should be referred to manufacturer.
1.0 Suspended Mount - Installation Instructions
Step 1
First, fix the hook on the lamp (rotate clockwise) then connect the hook with the lock ring.
[Diagram: Shows a hook being screwed into the top of the luminaire and then attached to a lock ring.]
Step 2
Use an electric drill to bore a hole on the wall.
[Diagram: Illustrates an electric drill making a hole in a wall surface.]
Step 3
Fix the hanger on the wall with screws.
[Diagram: Shows a mounting bracket (hanger) being secured to the wall with screws.]
Step 4
Fix one end of the chain to the wall, another end to the O/G hook from the light, finish the installation.
[Diagram: Depicts a chain connecting from the wall mount to the luminaire's O/G hook.]
2.0 Ceiling Mount - Installation Instructions
Step 1
Use an electric drill to bore a hole on the wall.
[Diagram: Illustrates an electric drill making a hole in a wall surface.]
Step 2
Install the expansion screw into the existing hole.
[Diagram: Shows an expansion screw being inserted into a pre-drilled hole.]
Step 3
Fix the U-bracket to the wall using a nut, plain cushion, and spring shim.
[Diagram: Shows a U-shaped bracket being attached to the wall with hardware including a nut, washer, and spring washer.]
Step 4
Use a wrench to reverse the hex nut and adjust the required angle.
[Diagram: Depicts a wrench being used to tighten or adjust a hex nut on the mounting bracket to set the luminaire's angle.]
3.0 Power & CCT Selectable
This luminaire offers selectable wattage and color temperature (CCT) options:
- Wattage Selectable Options: 150W/120W/100W, 240W/200W/180W, 310W/280W/240W.
- CCT Selectable Options: 40K (4000K) / 50K (5000K).
[Diagram: Shows DIP switches labeled '1' and '2' used to select wattage and CCT. Multiple configurations are illustrated with switch positions for different wattage/CCT combinations.]
4.0 Wiring Diagram
The luminaire is designed for connection to standard electrical systems:
- Input Voltage: 120-277/347Vac, 50/60Hz.
- Connections:
- Live: Connect to Black wire.
- Neutral: Connect to White wire.
- Ground: Connect to Green wire.
- LED Light: Connect to the luminaire's internal LED driver wiring.
- Dimming (0-10V): Connect Dim(+) to Purple wire, Dim(-) to Pink wire. Follow dimmer control manufacturer instructions.
[Diagram: A schematic showing wire connections: Live (Black) to fixture input, Neutral (White) to fixture input, Ground (Green) to fixture ground terminal. Separate connections for LED Light output and 0-10V dimming wires (Purple for positive, Pink for negative) are also shown, with a note to follow dimmer manufacturer instructions.]