Mapping Suite

Getting Started with Your Mapping Kit

What's in the box

A small white rectangular device with a single antenna, labeled 'RFG-003 Gateway with SIM Card (inserted)'.

Several small, rectangular devices with displays showing '12.1 °F', 'MIN 71.4', 'MAX 74.6'. Each is described as an 'RFL Data Logger (each with mounting plate and (2) AA batteries)'.

A thin, grey rectangular component with multiple small pins, labeled 'Replaceable Sensors™ with 3-Point NIST (sensor varies by mapping kit)'.

Important: Read Before Setup

⚠️ Setup must be completed in the correct order to ensure your mapping study runs as intended. This guide provides required steps for logging in, connecting hardware, pairing sensors, and preparing your loggers for use in the Mapping Suite.

⚠️ Do not begin installation or power on any devices until you have reviewed the full guide. Improper setup may result in configuration errors or unusable study data.

Step 1: Log In to Your Mapping Suite Account

⚠️ Your DicksonOne Mapping Suite account has already been created. The email address registered to the account is provided on the insert card inside your kit. Do not create a new account. Follow the steps below to complete your setup properly.

  1. Go to mapping.dicksonone.com
  2. Click Lost Password
  3. Enter the email address provided on your insert card
  4. Click Reset Password and follow the email instructions to set a new password
  5. Log in using your new credentials
  6. Once logged in, open a new browser tab and go to app.mapping.dicksonone.com
  7. You are now in the Mapping Suite application

Step 2: Set Up the Gateway

  1. Your gateway is already registered to your account
  2. Attach the antenna to the gateway
  3. Connect power using the power adapter or via PoE
  4. Wait approximately 2 minutes for the device to boot:
    1. The LED will pulse green ➡️ red ➡️ blue
    2. A pulsing blue LED confirms a successful cellular connection to your account

Step 3: Set Up the Loggers and Sensors

⚠️ Important: Once a sensor is connected to a logger, it becomes permanently paired and cannot be swapped. Write the sensor's serial number on the label next to the logger's sensor port before installation.

For each logger:

  1. Slide off the mounting plate
  2. Remove the battery door
  3. Insert 2 AA batteries
  4. Firmly insert the sensor into the sensor port
  5. Write the sensor serial number on the label on the back of the logger
  6. Replace the battery door and mounting plate
  7. Press the power button to turn the logger on

After approximately 1 minute, the logger will display a 6-digit registration code.

Step 4: Claim Loggers in Mapping Suite

⚠️ If your facility already has DicksonOne loggers or gateways installed, contact support@dicksonone.com before proceeding.

  1. Go to app.mapping.dicksonone.com and log in
  2. Navigate to Manage Hardware > Add Hardware

A web browser window showing the DicksonOne Mapping Suite interface. The main area is titled 'Manage Hardware' with a button labeled '+ Add Hardware'. Navigation links include 'Mapping Studies', 'Audit Trail', and 'Data Loggers'.

  1. All available loggers will appear in the Add Hardware table
  2. Click Register Logger next to each RFL-M device
  3. Once registered, loggers will appear as Available under Manage Hardware. They are now ready to be assigned for your mapping

A web browser window showing the DicksonOne Mapping Suite 'Manage Hardware' section. A table lists data loggers with columns for 'Logger Serial No.', 'Current Availability' (showing 'Available'), 'Study Status', 'Study Name', 'Firmware Version' (e.g., '1.4.2-M'), 'Last Reading Time', and 'Battery Level'. A button 'Register Logger' is visible next to each device.

To view this guide on your desktop, visit DicksonData.com/MappingQuickStart

Contact Information

Dickson North America

Addison, IL - USA

+1 (630) 543-3747

dicksondata.com/contact

Dickson Europe

Montpellier - France

+33 499 13 67 30

contact@dicksondata.fr

Dickson Asia-Pacific

Petaling Jaya – Malaysia

+603 749 40758

contact@dicksondata.my

©2025 Dickson. All rights reserved. Dickson, the Dickson logo, DicksonOne, and RF Gateway are the exclusive property of Dickson. All other brands mentioned are the property of their respective owners. This is a non-contractual document. Product photos and features may vary.

July 2025

Rev. 01

Models: RFG-003 Gateway, RFL Data Loggers, RFG-003 Battery Operated Data Logger, RFG-003, Battery Operated Data Logger, Operated Data Logger, Data Logger

File Info : application/pdf, 4 Pages, 381.20KB

PDF preview unavailable. Download the PDF instead.

Mapping-Suite-Quick-Start-Guide

References

macOS Version 14.7.4 (Build 23H420) Quartz PDFContext Word

Related Documents

Preview Dickson TSB/TWE/TWP Touchscreen Data Logger Quick Start Guide
A quick start guide for the Dickson TSB/TWE/TWP Touchscreen data logger, covering setup, connection via Ethernet or Wi-Fi, and integration with the DicksonOne platform.
Preview Dickson SP125, SP175, TP125 Environmental Data Logger Manual
Comprehensive user manual for Dickson SP125, SP175, and TP125 environmental data loggers. Covers features, specifications, calibration, DicksonWare software, and operation for accurate data recording and monitoring.
Preview Summer Temperature Mapping Services by Dickson
Dickson offers summer temperature mapping services to help businesses maintain compliance and protect critical assets during hot weather. Identify temperature vulnerabilities, ensure product integrity, and meet regulatory requirements.
Preview Dickson TH8-10 8" Temperature and Humidity Chart Recorder Datasheet
Datasheet for the Dickson TH8-10 8-inch chart recorder, detailing its features for temperature and humidity monitoring, specifications like accuracy, operating conditions, and included accessories.
Preview DICKSON Process Logger HT350: User Guide and Setup
Comprehensive guide to setting up, using, and troubleshooting the DICKSON Process Logger HT350, including software installation, data logging, and warranty information.
Preview DBL Data Logger Quick Start Guide - Dickson
Quick start guide for the Dickson DBL Data Logger, covering setup, configuration with DicksonWare 2.0, logging, data download, and firmware information.
Preview Dickson KT8 Series Temperature Recorders: User Manual and Quick Start Guide
Comprehensive guide for Dickson KT8P, KT8P2, KT8P3, and KT856 series remote sensing temperature recorders. Covers setup, operation, alarms, dip switches, calibration, troubleshooting, and warranty information.
Preview Dickson Calibration Accreditation Scope - ISO/IEC 17025 Certified
Official accreditation scope for Dickson laboratory, certified under ISO/IEC 17025:2017 and ANSI/NCSL Z540-1-1994 for chemical, mechanical, and thermodynamics calibration services.