Installation Guide for VON DUPRIN models including: 75, 75-F, CD75, QEL75--F, HW75, HW75-F, 75 Series Rim Exit Device, 75 Series, Rim Exit Device, Exit Device, Device

Von Duprin 75 Series Rim Device Installation Instructions

Von Duprin 75 Series Rim Device Installation Instructions

31 мая 2024 г. — Devices covered by these instructions: 75 Rim Exit Device. 75-F Rim Exit Device. CD75 Rim Exit Device. QEL75/-F Rim Exit Device. HW75 Rim Exit Device.


File Info : application/pdf, 12 Pages, 3.55MB

PDF preview unavailable. Download the PDF instead.

Von Duprin 75 series rim device installation instructions 116023
*47981500*
47981500 Rim Exit Device

75 Series
Devices covered by these instructions: 75 Rim Exit Device 75-F Rim Exit Device
CD75 Rim Exit Device QEL75/-F Rim Exit Device
HW75 Rim Exit Device HW75-F Rim Exit Device

Installation Instructions

Dogging Key (use with non-fire devices
to lock down pushbar)

Special tools needed: #10-24 and 1/4"-20 tap Drill bits: #7, #25, 1/8", 1/4", 5/16", 13/32"
1/2"
For hurricane rated device requirements, see page 2.

Customer Service
1-877-671-7011 www.allegion.com/us

© Allegion 2024 Printed in U.S.A. 47981500 Rev. 07/24-b

HHuurrrriiccaannee rraatteedd eexxiitt ddeevviiccee rreeqquuiirreemmeennttss ((wwhheenn uusseedd wwiitthh aapppprroovveedd AAlllleeggiioonn ddoooorr aapppplliiccaattiioonnss))

AApppplliiccaattiioonn

SSiinnggllee ddoooorr,, ssttaannddaarrdd ssttrriikkee

MMuulllliioonn

DDoouubbllee ddoooorr,, ssttaannddaarrdd ssttrriikkee

44995544 oorr KKRR44995544

229999

HHWW

7755

229999

((WWiinndd OOnnllyy))

11665544 oorr KKRR11665544 55665544 55775544

11660066 229999 11440088

7755--FF

229999FF

99995544 oorr KKRR99995544

449999FF

2

Device Subassembly
G H I

SCREW CHART
Screw ¹/4-20 x1" (25 mm)

Application
Trim mount or sex bolts: 1³/4" (44 mm) door

¹/4-20 x 1-¹/2" (38 mm)

2¹/4" (57 mm) door

#10-24 x 1" (25 mm)

Metal door surface mount (Yellow)

#10 x 1¹/4" (32 mm) Wood screw Wood door surface mount

#10-24 x ³/4" (19 mm) #10-24 x 1¹/8" (29 mm)

Surface mount or Sex bolts 1³/4" (44 mm) door
Sex bolts, 2¹/4" (57 mm) door

#10-16 x ³/8" (10 mm) Thread cutting

End cap

#10-24 x ³/4" (19 mm)

Metal frame

#10 x 1¹/2" (38 mm) Wood screw Wood frame

#10-24 x ³/4" (19 mm)

Metal frame

#10 x 1¹/2" (38 mm) Wood screw Wood frame

#10-24 x ³/4" (19 mm)

Metal frame

#10 x 1¹/2" (38 mm) Wood screw Wood frame

#10-12 x 10-24 x 1¹/4" (32 mm) combination

Metal or wood frame

#8-18 x ³/8" (10 mm) Thread cutting Center case cover

#8-32 x ³/8" (10 mm) Machine thread

Center case cover (75-F devices only)

3

1 Draw horizontal device and strike center lines (CL).

3 Install strike using two screws only at this time.
Panic Device

* 39¹³/16" (101.1 cm)

E

from finished floor

RHR

LHR

RHR

* For double doors with a mullion and strike already
installed, use existing
strike center line.

Door Install strike
1/16" past door side of stop
1439 Strike (standard)

2 Prepare frame for strike using paper templates.
L See pages 9 and 10 for strike templates and frame
preparation dimensions.

F
299 Strike
Fire Rated Device

Door
H
Mullion 1606 Strike

1439 strike

G

preparation

shown

#25 Metal

#10-24

Wood

OR ¹/8" (3 mm) x 1" (25 mm) deep

L See "Screw Chart" on previous page for screw types and
sizes.

299F Strike
L For 499F strike installation, see page 7.
499F Strike

4

4 If using a 1439 strike, install wear strip. If not, go to 6 Prepare lock side of door for device and trim.

step 5.

Door side

See trim instructions for pull side door preparation.

Wear strip
X

A. Center wear strip on strike as shown. B. Mark and drill 1/8" dia. holes (4 places). C. Install wear strip with flat head drive
rivets (4 places) from 1439 strike package.
5 Tape template to door and mark door.
Paper Template (pages 11 and 12)

Mark door cut-out

Mark 4 holes

CL

See template for drill and cut-out information
X
7 Measure to determine length to cut device.
1-3/16" minimum clearance (with end cap removed)
Device aligned with mounting
holes

Mark vertical line X-X for trim alignment
Note: Line X-X is a reference line on the paper template used for trim and exit device alignment. Line X-X shown here should correspond to line X-X in the trim installation instructions

5/16"
Note
If 5/8" diameter wire access hole has been predrilled in door, cut device 5/16" from center of hole.

5

8 If necessary, cut device.
Prepare device for cutting
Tape
Remove anti-rattle clip
Cover plate (flush to pushbar)
Pushbar

11 Install hinge stile mounting bracket.
Mark and prepare 2 mounting holes

Mounting bracket flush

Level device

1/4" drill inside 13/32" drill outside
13/32" drill thru

Door surface
Wood Metal

Cut device square

Secure mounting bracket

Note: Device must be cut square for proper end cap fit

Cut device
square and remove all burrs

#425 Sex bolts (required)
C

9 If using a cylinder with a tailpiece, prepare device
and cylinder.
Cut tailpiece if needed
Tailpiece 1/8" guide
*Tailpiece

12 Adjust strike as needed.

Shim strike for 3/16" clearance to chassis

1409 Strike

299/299F/1606 Strike

3/16"

3/16"

Rotate tailpiece guide to match
tailpiece

* Tailpiece is attached to trim or cylinder depending on application

10 Attach center case to door.

cCaesneter

Shim (if necessary)

Shim (if necessary)

13 Install strike support screw.

OR

Trim (optional)

A

OR

G

#325 Sex bolts (required when not using trim)

METAL

WOOD
#25 ¹/8" (3 mm) x 1" (25 mm) Deep

#10-24

6

14 Install 2 support screws and center case cover

15 Install 2 support screws and center case cover

Remove protective film from pushbar
I
* For fire devices only use #8-32 machine thread screw. Center case cover

B
2 support screws

End cap
D

499F STRIKE INSTALLATION

1. Prepare and install screws through 2. Install strike hook and additional

two strike slots.

strike screws.

Roller (against door)

Wood

Metal

#7 Drill ¹/4" (6 mm)20 Tap 2 places
¹³/32" (10 mm) Drill thru for sex bolts 2 places

3. Template aligns as shown.
Template (align on CL and
against strike

#25 Drill #10-24 Tap
2 places
L If using a mullion,
holes may be predrilled

CL
#25 Drill #10-24 Tap
3 places

7

OPTIONAL EQUIPMENT CD (Cylinder Dogging) Option
a
b

c

d

f

e

Dog

Undog

8

1439 Strike

1439 Strike
Frame Preparation

Wood Metal

RHR shown (LHR opposite)

#25 Drill #10-24 tap
1/8" Drill pilot 1" deep

Cut -out

7/8"

CL

7/16"

CL

7/8"

Blade stop

1-9/16" to face of door

7/16"

9

299/299F/1606 Strike

Template

299

Door

Door

299F

1606 Strike
Door

Stop

Stop

Mullion

Door edge Wood Metal

Cut paper along this line and place on door stop against edge of door
(see picture below)
Template
CL

RHR

#25 Drill #10-24 tap
1/8" Drill pilot 1" deep

CL

1-1/16" 1-1/16"

5/8"

LHR

10

Line X-X is a reference line for trim and exit device alignment.
Line X-X shown here should correspond to line X-X in the trim installation instructions

X
CLof device
1/4"

75 Rim device
Template

Wood Metal

Holes - 2 places
#25 drill inside #10-24 tap
1/8" diameter drill 1" deep pilot hole
3/16"
Align this line with edge of strike or roller

LHR

Cut-out device side only
5/8" deep for wood door

3-1/8"

1-3/16" 7/8"
CL of device
7/8" 1-3/16"

1/4" Radius
7/32" 7/8"
19/32"

3-1/8"

Holes - 2 places

Wood Metal

5/16" drill inside 13/32" drill outside (sex bolts)
1/2" drill outside (trim)

X

13/32" drill thru (sex bolts) 1/2" drill thru (trim)

11

75 Rim device
Template

X
Device CL
1/4"

Line X-X is a reference line for trim and exit device alignment. Line X-X shown here should correspond to line X-X in
the trim installation instructions

RHR
Cut-out device side only
5/8" deep for wood door
3-1/8"
1-3/16" 7/8"
Device CL
7/8" 1-3/16"
3-1/8"

Wood Metal

Holes - 2 places
#25 drill inside #10-24 tap
1/8" diameter drill 1" deep pilot hole
3/16"
Align this line with edge of strike or roller
1/4" Radius 7/32" 7/8" 19/32"

Wood Metal

Holes - 2 places

5/16" drill inside 13/32" drill outside (sex bolts)
1/2" drill outside (trim)

13/32" drill thru (sex bolts) 1/2" drill thru (trim)

X

12



References

Adobe PDF Library 17.0