Installation Guide for VON DUPRIN models including: 75, 75-F, CD75, QEL75--F, HW75, HW75-F, 75 Series Rim Exit Device, 75 Series, Rim Exit Device, Exit Device, Device
31 мая 2024 г. — Devices covered by these instructions: 75 Rim Exit Device. 75-F Rim Exit Device. CD75 Rim Exit Device. QEL75/-F Rim Exit Device. HW75 Rim Exit Device.
File Info : application/pdf, 12 Pages, 3.55MB
DocumentDocument*47981500* 47981500 Rim Exit Device 75 Series Devices covered by these instructions: 75 Rim Exit Device 75-F Rim Exit Device CD75 Rim Exit Device QEL75/-F Rim Exit Device HW75 Rim Exit Device HW75-F Rim Exit Device Installation Instructions Dogging Key (use with non-fire devices to lock down pushbar) Special tools needed: #10-24 and 1/4"-20 tap Drill bits: #7, #25, 1/8", 1/4", 5/16", 13/32" 1/2" For hurricane rated device requirements, see page 2. Customer Service 1-877-671-7011 www.allegion.com/us © Allegion 2024 Printed in U.S.A. 47981500 Rev. 07/24-b HHuurrrriiccaannee rraatteedd eexxiitt ddeevviiccee rreeqquuiirreemmeennttss ((wwhheenn uusseedd wwiitthh aapppprroovveedd AAlllleeggiioonn ddoooorr aapppplliiccaattiioonnss)) AApppplliiccaattiioonn SSiinnggllee ddoooorr,, ssttaannddaarrdd ssttrriikkee MMuulllliioonn DDoouubbllee ddoooorr,, ssttaannddaarrdd ssttrriikkee 44995544 oorr KKRR44995544 229999 HHWW 7755 229999 ((WWiinndd OOnnllyy)) 11665544 oorr KKRR11665544 55665544 55775544 11660066 229999 11440088 7755--FF 229999FF 99995544 oorr KKRR99995544 449999FF 2 Device Subassembly G H I SCREW CHART Screw ¹/4-20 x1" (25 mm) Application Trim mount or sex bolts: 1³/4" (44 mm) door ¹/4-20 x 1-¹/2" (38 mm) 2¹/4" (57 mm) door #10-24 x 1" (25 mm) Metal door surface mount (Yellow) #10 x 1¹/4" (32 mm) Wood screw Wood door surface mount #10-24 x ³/4" (19 mm) #10-24 x 1¹/8" (29 mm) Surface mount or Sex bolts 1³/4" (44 mm) door Sex bolts, 2¹/4" (57 mm) door #10-16 x ³/8" (10 mm) Thread cutting End cap #10-24 x ³/4" (19 mm) Metal frame #10 x 1¹/2" (38 mm) Wood screw Wood frame #10-24 x ³/4" (19 mm) Metal frame #10 x 1¹/2" (38 mm) Wood screw Wood frame #10-24 x ³/4" (19 mm) Metal frame #10 x 1¹/2" (38 mm) Wood screw Wood frame #10-12 x 10-24 x 1¹/4" (32 mm) combination Metal or wood frame #8-18 x ³/8" (10 mm) Thread cutting Center case cover #8-32 x ³/8" (10 mm) Machine thread Center case cover (75-F devices only) 3 1 Draw horizontal device and strike center lines (CL). 3 Install strike using two screws only at this time. Panic Device * 39¹³/16" (101.1 cm) E from finished floor RHR LHR RHR * For double doors with a mullion and strike already installed, use existing strike center line. Door Install strike 1/16" past door side of stop 1439 Strike (standard) 2 Prepare frame for strike using paper templates. L See pages 9 and 10 for strike templates and frame preparation dimensions. F 299 Strike Fire Rated Device Door H Mullion 1606 Strike 1439 strike G preparation shown #25 Metal #10-24 Wood OR ¹/8" (3 mm) x 1" (25 mm) deep L See "Screw Chart" on previous page for screw types and sizes. 299F Strike L For 499F strike installation, see page 7. 499F Strike 4 4 If using a 1439 strike, install wear strip. If not, go to 6 Prepare lock side of door for device and trim. step 5. Door side See trim instructions for pull side door preparation. Wear strip X A. Center wear strip on strike as shown. B. Mark and drill 1/8" dia. holes (4 places). C. Install wear strip with flat head drive rivets (4 places) from 1439 strike package. 5 Tape template to door and mark door. Paper Template (pages 11 and 12) Mark door cut-out Mark 4 holes CL See template for drill and cut-out information X 7 Measure to determine length to cut device. 1-3/16" minimum clearance (with end cap removed) Device aligned with mounting holes Mark vertical line X-X for trim alignment Note: Line X-X is a reference line on the paper template used for trim and exit device alignment. Line X-X shown here should correspond to line X-X in the trim installation instructions 5/16" Note If 5/8" diameter wire access hole has been predrilled in door, cut device 5/16" from center of hole. 5 8 If necessary, cut device. Prepare device for cutting Tape Remove anti-rattle clip Cover plate (flush to pushbar) Pushbar 11 Install hinge stile mounting bracket. Mark and prepare 2 mounting holes Mounting bracket flush Level device 1/4" drill inside 13/32" drill outside 13/32" drill thru Door surface Wood Metal Cut device square Secure mounting bracket Note: Device must be cut square for proper end cap fit Cut device square and remove all burrs #425 Sex bolts (required) C 9 If using a cylinder with a tailpiece, prepare device and cylinder. Cut tailpiece if needed Tailpiece 1/8" guide *Tailpiece 12 Adjust strike as needed. Shim strike for 3/16" clearance to chassis 1409 Strike 299/299F/1606 Strike 3/16" 3/16" Rotate tailpiece guide to match tailpiece * Tailpiece is attached to trim or cylinder depending on application 10 Attach center case to door. cCaesneter Shim (if necessary) Shim (if necessary) 13 Install strike support screw. OR Trim (optional) A OR G #325 Sex bolts (required when not using trim) METAL WOOD #25 ¹/8" (3 mm) x 1" (25 mm) Deep #10-24 6 14 Install 2 support screws and center case cover 15 Install 2 support screws and center case cover Remove protective film from pushbar I * For fire devices only use #8-32 machine thread screw. Center case cover B 2 support screws End cap D 499F STRIKE INSTALLATION 1. Prepare and install screws through 2. Install strike hook and additional two strike slots. strike screws. Roller (against door) Wood Metal #7 Drill ¹/4" (6 mm)20 Tap 2 places ¹³/32" (10 mm) Drill thru for sex bolts 2 places 3. Template aligns as shown. Template (align on CL and against strike #25 Drill #10-24 Tap 2 places L If using a mullion, holes may be predrilled CL #25 Drill #10-24 Tap 3 places 7 OPTIONAL EQUIPMENT CD (Cylinder Dogging) Option a b c d f e Dog Undog 8 1439 Strike 1439 Strike Frame Preparation Wood Metal RHR shown (LHR opposite) #25 Drill #10-24 tap 1/8" Drill pilot 1" deep Cut -out 7/8" CL 7/16" CL 7/8" Blade stop 1-9/16" to face of door 7/16" 9 299/299F/1606 Strike Template 299 Door Door 299F 1606 Strike Door Stop Stop Mullion Door edge Wood Metal Cut paper along this line and place on door stop against edge of door (see picture below) Template CL RHR #25 Drill #10-24 tap 1/8" Drill pilot 1" deep CL 1-1/16" 1-1/16" 5/8" LHR 10 Line X-X is a reference line for trim and exit device alignment. Line X-X shown here should correspond to line X-X in the trim installation instructions X CLof device 1/4" 75 Rim device Template Wood Metal Holes - 2 places #25 drill inside #10-24 tap 1/8" diameter drill 1" deep pilot hole 3/16" Align this line with edge of strike or roller LHR Cut-out device side only 5/8" deep for wood door 3-1/8" 1-3/16" 7/8" CL of device 7/8" 1-3/16" 1/4" Radius 7/32" 7/8" 19/32" 3-1/8" Holes - 2 places Wood Metal 5/16" drill inside 13/32" drill outside (sex bolts) 1/2" drill outside (trim) X 13/32" drill thru (sex bolts) 1/2" drill thru (trim) 11 75 Rim device Template X Device CL 1/4" Line X-X is a reference line for trim and exit device alignment. Line X-X shown here should correspond to line X-X in the trim installation instructions RHR Cut-out device side only 5/8" deep for wood door 3-1/8" 1-3/16" 7/8" Device CL 7/8" 1-3/16" 3-1/8" Wood Metal Holes - 2 places #25 drill inside #10-24 tap 1/8" diameter drill 1" deep pilot hole 3/16" Align this line with edge of strike or roller 1/4" Radius 7/32" 7/8" 19/32" Wood Metal Holes - 2 places 5/16" drill inside 13/32" drill outside (sex bolts) 1/2" drill outside (trim) 13/32" drill thru (sex bolts) 1/2" drill thru (trim) X 12