Elitech DR-230 Temperature and Humidity Recorder Instructions
Product Overview
The DR-230 series is a large screen temperature and humidity recorder used for real-time monitoring and recording of ambient temperature and humidity. It supports functions such as over-limit alarm and historical data upload. The recorder consists of an external temperature and humidity sensor and host equipment. Users interact with the recorder via the Jingchuang Cold Cloud APP. Operating parameters, including temperature unit, time zone, recording interval, alarm switch, alarm parameters, and sensor type, can be set through the APP. Recorded data stored in the recorder can be read via the APP and automatically uploaded to the cloud. Historical data can also be accessed through the APP for report export and other operations. The product is widely used in industrial workshops, warehouses, and similar scenarios.
1. Product Features
- Supports wall hanging, table, and other placement methods.
- Features a large display panel with clear and rich content.
- Utilizes Bluetooth communication for cost-free data transfer.
- Offers local storage for 30,000 sets of data, with support for cyclic storage.
- Includes local sound and light alarms for timely alerts on over-limit conditions.
- Suitable for warehouses, workshops, and other similar environments.
2. Product Interface
The device display shows: ① Measurement channel, ② Real-time temperature (°C), ③ Current time, ④ Real-time humidity (%RH).
Measurement Channel
When the device is configured with an external sensor type, the data from the first external T/H sensor is displayed (indicated by '1------'), followed by the data from the second external T/H sensor (indicated by '2------'). If the device is configured with a built-in sensor type, the channel indicator is not displayed, and the current display data is from the built-in sensor.
Alarm Display
When any measured temperature or humidity value exceeds the limit, the device flashes the full screen at a 1-second interval. When the measurement value returns to the normal range, the device automatically restores the steady on display.
3. Product Structure
The back of the device shows: ① wall hanging hole, ② Equipment information.
Interface description: ? power supply interface, ? alarm interface, ?️ sensor interface.
Note: Please connect the external sensor and alarm before powering on the device.
4. Selection List
Probe type | External | |
---|---|---|
Channel | Temperature and humidity of 1 channel | 2 way temperature and humidity |
Measuring range | Temperature: -40~80°C Humidity: 0~100%RH | |
Sensor type | Digital temperature and humidity sensor | |
Measurement accuracy | Temperature: ± 0.5 °C Humidity: ± 5%RH |
5. Technical Specifications
- Power input: 5V/2A
- Temperature display resolution: 0.1°C
- Humidity display resolution: 0.1%RH
- Number of recording groups: 30,000 groups
- Data storage: cyclic storage
- Recording interval: 10s~24H can be set (default 10 minutes)
- Alarm parameters: 3 seconds /10 seconds/constant ringing (default off)
- Screen: Plexiglass panel
- Communication method: Bluetooth
- Alarm mode: external alarm, flashing display
- Size: 215mm*165mm*19mm
Manual
Peripheral Connections
According to the interface icons on the back of the recorder, connect the corresponding peripherals (power supply, sensor, alarm).
Power Supply
Use the standard power cord to connect the recorder for power supply. The device will turn on automatically after power-on.
Configuration
Use the Elitech iCold APP to set the recorder parameters. During the recording process, if parameter changes are needed, stop the recording and then re-pair the device. Note: After reconfiguration, the original data will be cleared.
Alarm
- The Elitech iCold APP can be used to configure device alarm parameters, including temperature alarm upper limit, temperature alarm lower limit, humidity alarm upper limit, humidity alarm lower limit, alarm mode, and alarm switch.
- When any measurement parameter of temperature or humidity exceeds the limit, the device flashes the screen every 1 second. When the temperature and humidity value returns to the limited range, the device automatically returns to normal display.
- When any temperature and humidity measurement parameter exceeds the limit, the device will start timing according to the alarm delay time setting. If the temperature and humidity measurement value does not return to normal within the delay time, it will alarm according to the set alarm mode after the delay time is up (external acousto-visual alarm).
APP Manual
1. Sign In
Scan the QR code on the front page of this manual or search for "Elitech iCold" in the mobile app store to download and install. After installation, open the APP and follow the prompts to register and log in.
Login Screen Description: Fields for Username/Email, Password, Remember Password, Login button, Register button, and a link for Fast binding.
Account Type Selection Description: Options for 'Enterprise' and 'Individual' registration.
Registration Screen Description: Fields for Username, Email, Password, Confirm password, Enter code, and Send Code button.
2. Add Device
After login, the main display is shown. Click the menu icon ☰ in the upper left corner of the home page. Go to the device classification screen. Click "Bluetooth Data Logger" and then "add devices".
Device List Screen Description: Shows various devices with status (Record/Stopped), temperature, humidity, and start/stop times.
Device Classification Screen Description: Options like Recorder, Bluetooth Data Logger, NFC Temperature Tag.
Nearby Devices List Description: Displays a list of nearby devices with their details.
3. Parameter Setting
Swipe up and down to select the device or click the scan icon ? in the upper right corner. Scan the barcode on the back of the device, select the device to connect, and choose "Config" to configure parameters. After connection, click "Read data". When data is successfully read, the device will be automatically added.
Parameter Setting Screen 1 Description: Options to set Temperature Unit (°C/°F), Timezone (e.g., GMT+08:00), Logging Interval (e.g., 00h 00m 10s), Audible alarm (Enable/Disable).
Parameter Setting Screen 2 Description: Options for Probe type (Internal T&H probe, Double T&H probe), Upper limit(T), Upper limit(T) delay, Low limit(T), Low limit(T) delay.
Parameter Setting Screen 3 Description: Options for Temperature compensation, Upper limit(H), Upper limit(H) delay, Low limit(H), Low limit(H) delay, Humidity compensation.
Steps:
- Set the temperature unit.
- Set the time zone.
- Set the recording interval.
- Set the alarm and alarm mode.
- Set the sensor type of the recorder.
- Set the alarm upper and lower limits and alarm delay.
After parameters are set, click "OK" to complete delivery. The setting will automatically start recording.
4. Enable/Stop Recording
Enable recording: After tapping OK on the parameter setting screen, the device starts recording data.
Stop recording: Click "Read data" to enter the data interface, and click the ⏹️ icon in the upper right corner to stop recording.
Status Screen Description: Shows device details, recording status (Record/Stopped), sync time, start time, temperature, humidity, and a list of recorded data points with timestamps.
Note: After manually stopping the record, you need to reconfigure the parameters to turn on the record again.
5. View the Data
In the recorder connection interface, click "Read data". The recorder's stored data is automatically read.
After data display, charts and detailed data modes are supported. In the detailed data display interface, you can export the report.
Data Display Interface Description: Shows charts and a table of recorded temperature and humidity values over time.
In the "NearBy" interface, click "Cloud" to enter cloud data view. On this interface, you can click the historical trip to view corresponding data and export the data report.
Cloud Data View Description: Displays trip information and historical data.
6. Check the Device Status
① "Record": The device is in the record state.
② "Stopped": The device is in the stopping state.
Device Status Screen Description: Shows lists of devices with their current state (Record/Stopped) and key readings.
Visit URL http://new.i-elitech.com to log in for more operation. Click "Help" to obtain Cloud and App operation instructions.