DOMO DO266A Portable Air Conditioner Installation Quick Guide
Please read the complete instruction manual carefully for all necessary information.
Wall Installation
Components for wall installation include a circular adapter for the wall, a flexible exhaust hose, and a window sealing kit. The exhaust hose connects to the rear of the portable air conditioner unit. For wall installation, the exhaust hose connects to a wall adapter. Recommended hose length dimensions are a minimum of 30 cm and a maximum of 120 cm.
Diagrams show the portable air conditioner unit, the exhaust hose, a wall adapter, and a wall plate for wall mounting.
Window Installation
A window sealing kit is provided for window installations. The exhaust hose has a minimum length of 30 cm and a maximum length of 50 cm.
Horizontal Sliding Window
This installation method is suitable for horizontal sliding windows with a width between 67 cm and 123 cm. The process involves a coiled exhaust hose, a window sealing panel, a plastic pin to secure the panel, and connecting the hose to the panel and the unit.
Installation steps:
- Position the window sealing panel in the sliding window track.
- Secure the panel with the plastic pin.
- Connect the exhaust hose to the panel.
- Connect the other end of the hose to the air conditioner unit. ✔️
Vertical Sliding Window
This installation method is for vertical sliding windows. The process involves connecting the exhaust hose to a window sealing panel and the air conditioner unit.
Installation steps:
- Install the window sealing panel into the vertical window frame.
- Connect the exhaust hose to the panel.
- Connect the other end of the hose to the air conditioner unit.