User Guide for ARISTA models including: DCA-DM-C450 DANZ Monitoring Fabric, DCA-DM-C450 DANZ, Monitoring Fabric, Fabric
Product ation Library - Arista
File Info : application/pdf, 75 Pages, 9.72MB
DocumentDocumentDANZ Monitoring Fabric Hardware Guide Arista Networks www.arista.com DANZ Monitoring Fabric Hardware Guide DOC-06658-01 Headquarters Support Sales 5453 Great America Parkway Santa Clara, CA 95054 USA +1-408-547-5500 +1-408-547-5502 +1-866-476-0000 +1-408-547-5501 +1-866-497-0000 www.arista.com/en/ support@arista.com sales@arista.com © Copyright 2023 Arista Networks, Inc. All rights reserved. The information contained herein is subject to change without notice. The trademarks, logos and service marks ("Marks") displayed in this documentation are the property of Arista Networks in the United States and other countries. Use of the Marks are subject to Arista Network Terms of Use Policy, available at www.arista.com/en/terms-of-use. Use of marks belonging to other parties is for informational purposes only. Contents Contents Chapter 1: DMF Controller Nodes................................................................. 1 1.1 DMF Controller Node (DCA-DM-CDL) Specification.........................................................................1 1.1.1 LEDs and Indicators............................................................................................................ 2 1.1.2 Platform Management Tool................................................................................................. 3 1.1.3 Technical Specification........................................................................................................ 4 1.2 DMF Controller Node (DCA-DM-CDL(HWDL2)) Specification.......................................................... 4 1.2.1 LEDs and Indicators............................................................................................................ 6 1.2.2 Platform Management Tool................................................................................................. 7 1.2.3 Technical Specification........................................................................................................ 8 1.3 DMF Controller Node (DCA-DM-C450) Specification....................................................................... 8 1.3.1 LEDs and Indicators.......................................................................................................... 10 1.3.2 Platform Management Tool............................................................................................... 11 1.3.3 Technical Specification...................................................................................................... 12 Chapter 2: DMF Service Nodes................................................................... 13 2.1 DMF Service Node (DCA-DM-SC/DCA-DM-SC2) Specification..................................................... 13 2.1.1 LEDs and Indicators.......................................................................................................... 15 2.1.2 Platform Management Tool............................................................................................... 16 2.1.3 Technical Specification...................................................................................................... 17 2.2 DMF Service Node (DCA-DM-SDL/DCA-DM-SDL2) Specification................................................. 18 2.2.1 LEDs and Indicators.......................................................................................................... 22 2.2.2 Platform Management Tool............................................................................................... 23 2.2.3 Technical Specification...................................................................................................... 24 2.3 DMF Service Node (DCA-DM-SEL) Specification...........................................................................25 2.3.1 LEDs and Indicators.......................................................................................................... 28 2.3.2 Platform Management Tool............................................................................................... 29 2.3.3 Technical Specification...................................................................................................... 30 Chapter 3: Arista Analytics Nodes.............................................................. 32 3.1 Arista Analytics Node (DCA-DM-AA/DCA-DM-AA2/DCA-DM-AA3) Specification........................... 32 3.1.1 LEDs and Indicators.......................................................................................................... 33 3.1.2 Platform Management Tool............................................................................................... 34 3.1.3 Technical Specification...................................................................................................... 35 3.2 Arista Analytics Node (DCA-DM-AN450) Specification................................................................... 35 3.2.1 LEDs and Indicators.......................................................................................................... 37 3.2.2 Platform Management Tool............................................................................................... 38 3.2.3 Technical Specification...................................................................................................... 39 Chapter 4: DMF Recorder Nodes................................................................ 40 4.1 DMF Recorder Node (DCA-DM-RA) Specification..........................................................................40 4.1.1 LEDs and Indicators.......................................................................................................... 42 4.1.2 Platform Management Tool............................................................................................... 42 4.1.3 Technical Specification...................................................................................................... 43 4.2 DMF Recorder Node (DCA-DM-RA2) Specification........................................................................43 4.2.1 LEDs and Indicators.......................................................................................................... 45 4.2.2 Platform Management Tool............................................................................................... 46 iii 4.2.3 Technical Specification...................................................................................................... 47 4.3 DMF Recorder Node (DCA-DM-RA3) Specification........................................................................47 4.3.1 LEDs and Indicators.......................................................................................................... 49 4.3.2 Platform Management Tool............................................................................................... 50 4.3.3 Technical Specification...................................................................................................... 51 Chapter 5: Arista Supported Hardware.......................................................52 5.1 Arista 7050CX3-32S Specifications.................................................................................................52 5.1.1 Switch LEDs for Monitoring Port and Environmental Status............................................. 52 5.1.2 Port and Environmental LEDs........................................................................................... 54 5.2 Arista 7050SX3-48YC8 Specifications............................................................................................ 55 5.2.1 Switch LEDs for Monitoring Port and Environmental Status............................................. 55 5.2.2 Port and Environmental LEDs........................................................................................... 57 5.3 Arista 7050SX3-48YC12 Specifications.......................................................................................... 58 5.3.1 Switch LEDs for Monitoring Port and Environmental Status............................................. 58 5.3.2 Port and Environmental LEDs........................................................................................... 60 5.4 Arista 7050SX3-96YC8 Specifications............................................................................................ 61 5.4.1 Switch LEDs for Monitoring Port and Environmental Status............................................. 61 5.4.2 Port and Environmental LEDs........................................................................................... 63 5.5 Arista 7260CX3-64 Specifications................................................................................................... 64 5.5.1 Switch LEDs for Monitoring Port and Environmental Status............................................. 64 5.5.2 Port and Environmental LEDs........................................................................................... 66 5.6 Arista 7260CX3-64E Specifications.................................................................................................67 5.6.1 Switch LEDs for Monitoring Port and Environmental Status............................................. 68 5.6.2 Port and Environmental LEDs........................................................................................... 69 5.7 Arista 7280-Series Specifications....................................................................................................70 Chapter 6: References.................................................................................. 71 6.1 Related Documents......................................................................................................................... 71 iv Chapter 1 DMF Controller Nodes This chapter describes the DMF Controller Nodes available from Arista Networks. 1.1 DMF Controller Node (DCA-DM-CDL) Specification This section describes the LEDs provided for monitoring environmental and port status on the DMF Controller Node (DCA-DM-CDL). The DMF Controller Node (DCA-DM-CDL) is available as an enterprise-class, 2-socket, 1-RU rack-mounted hardware appliance designed to deliver the right combination of performance, redundancy, and value in a high-density chassis. Figure 1-1: DMF Controller Node (DCA-DM-CDL) Bezel 1 Controller Node Security Bezel 2 LCD menu buttons 3 LCD panel Figure 1-2: DMF Controller Node (DCA-DM-CDL) Front Panel 1 System identification button / indicator 2 Optical drive 3 Video connector 4 USB ports 5 Power-on indicator / Power button 6 Micro USB (not supported) 7 Information tag 8 Hard drives 1 Figure 1-3: DMF Controller Node (DCA-DM-CDL) Rear Panel 1.1.1 1 Serial connector (Default Baud Rate 115200) 2 iDRAC Ethernet interface 3 Ethernet connector 1 Controller Node management port 1 (10/100/1000 Mb/s) 4 Ethernet connector 3 Not supported 5 Ethernet connector 4 10-GbE SFP+ packet capture port 6 Ethernet connector 5 Not supported 7 Ethernet connector 6 Not supported 8 PSU status indicators 9 Power Supply 2 10 Power Supply 1 11 Ethernet connector 2 Controller Node management port 2 (10/100/1000 Mb/s) 12 USB ports 13 Video connector 14 System identification button 15 System identification indicator LEDs and Indicators The following table lists the meaning of each LED or other indicator. 2 DMF Controller Nodes 1.1.2 Indicator, Button, or Connector Description Power-on indicator Green: System power is on Off: System power is off System identification indicator Off: Normal operating conditions in front panel Blue blinking: System identification has been activated System identification indicator Blue: Normal operation condition in rear panel Blue blinking: System identification has been activated Amber blinking: Fault detected with error code followed by descriptive text in LCD panel 10/100/1000 Mbps Ethernet connector 1, 2 Link indicator Green: A valid 1000 Mb/s network link is established Amber: A valid 10/100 Mb/s network link is established Off: Link is down Activity indicator Green blinking: Network data is being sent or received Off: No link activity 10G SFP+ Ethernet connector Link indicator 4 Green: A valid 10G network link is established Off: Link is down Activity indicator Green blinking: Network data is being sent or received Off: No link activity Power Supply status Green: A valid power source is connected to the power supply and the power supply is operational Amber blinking: Indicates a problem with the power supply Off: Power is off Platform Management Tool DMF Controller Node (DCA-DM-CDL) supports iDRAC 9 platform management tools. · iDRAC 9 supported feature: remote power management, virtual console. 3 1.1.3 Technical Specification Controller Node Processor Form Factor (H X W X D) Memory Hard Drive Networking DCA-DM-CDL 2 x Intel Xeon Silver 4114 2.20GHz, 10 Cores, 20 Threads, 9.6GT/s 2UPI, 14M Cache, Turbo, HT, 85W, DDR4-2400 1-RU Rack Server (4.28cm x 43.4cm x 69.3cm) 4 X 16 GB RDIMM, 2666 MT/s 2 X 1 TB 7.2K RPM SATA 6Gbps 3.5in Hot-plug Hard Drives; RAID 1 for H330+ Embedded NIC: 2 X 1GbE LOM Network Adapter 1: Intel X710 Dual Port 10Gb DA/SFP+ server adapter Network Adapter 2: Intel X550 Dual Port 10Gb Base-T server adapter Power Additional Features 2 X Hot Plug Power Supplies 550W Fan fault tolerance; ECC memory; interactive LCD screen; ENERGY STAR® compliant Environment Temperature Continuous Temperature - Storage Relative Humidity Continuous Relative Humidity Storage Altitude Continuous Altitude Storage Specification 5°C to 40°C (41°F to 104°F) with no direct sunlight on the equipment -40°C to 65°C (-40°F to 149°F) with a maximum temperature gradation of 20°C per hour 5% to 85% with 29°C (84.2°F) maximum dew point 5% to 95% at a maximum wet bulb temperature of 33°C (91°F), atmosphere must be non-condensing at all times 3048m (10,000ft) 12,000m (39,370ft) 1.2 DMF Controller Node (DCA-DM-CDL(HWDL2)) Specification This section describes the LEDs provided for monitoring environmental and port status on the DMF Controller Node (DCA-DM- CDL(HWDL2)). 4 DMF Controller Nodes The DMF Controller Node (DCA-DM-CDL(HWDL2)) is available as an enterprise-class, 2-socket, 1-RU rackmounted hardware appliance designed to deliver the right combination of performance, redundancy, and value in a high-density chassis. Figure 1-4: DMF Controller Node (DCA-DM-CDL(HWDL2)) Bezel 1 Controller Node Security Bezel 2 LCD menu buttons 3 LCD panel Figure 1-5: DMF Controller Node (DCA-DM-CDL(HWDL2)) Front Panel 1 System identification button / indicator 2 Optical drive 3 Video connector 4 USB ports 5 Power-on indicator / Power button 6 Micro USB (not supported) 7 Information tag 8 Hard drives 5 Figure 1-6: DMF Controller Node (DCA-DM-CDL(HWDL2)) Rear Panel 1.2.1 1 Serial connector (Default Baud Rate 115200) 2 iDRAC Ethernet interface 3 Ethernet connector 1 Controller Node management port 1 (10/100/1000 Mb/s) 4 Ethernet connector 3 Not supported 5 Ethernet connector 4 10-GbE SFP+ packet capture port 6 Ethernet connector 5 Not supported 7 Ethernet connector 6 Not supported 8 PSU status indicators 9 Power Supply 2 10 Power Supply 1 11 Ethernet connector 2 Controller Node management port 2 (10/100/1000 Mb/s) 12 USB ports 13 Video connector 14 System identification button 15 System identification indicator LEDs and Indicators The following table lists the meaning of each LED or other indicator. 6 DMF Controller Nodes 1.2.2 Indicator, Button, or Connector Description Power-on indicator Green: System power is on Off: System power is off System identification indicator Off: Normal operating conditions in front panel Blue blinking: System identification has been activated System identification indicator Blue: Normal operation condition in rear panel Blue blinking: System identification has been activated Amber blinking: Fault detected with error code followed by descriptive text in LCD panel 10/100/1000 Mbps Ethernet connector 1, 2 Link indicator Green: A valid 1000 Mb/s network link is established Amber: A valid 10/100 Mb/s network link is established Off: Link is down Activity indicator Green blinking: Network data is being sent or received Off: No link activity 10G SFP+ Ethernet connector Link indicator 4 Green: A valid 10G network link is established Off: Link is down Activity indicator Green blinking: Network data is being sent or received Off: No link activity Power Supply status Green: A valid power source is connected to the power supply and the power supply is operational Amber blinking: Indicates a problem with the power supply Off: Power is off Platform Management Tool DMF Controller Node (DCA-DM-CDL(HWDL2)) supports iDRAC 9 platform management tools. · iDRAC 9 supported feature: remote power management, virtual console. 7 1.2.3 Technical Specification Controller Node Processor Form Factor (H X W X D) Memory Hard Drive Networking DCA-DM-CDL (HWDL2) 2 x Intel Xeon Silver 4114 2.20GHz, 10 Cores, 20 Threads, 9.6GT/s 2UPI, 14M Cache, Turbo, HT, 85W, DDR4-2400 1-RU Rack Server (4.28cm x 43.4cm x 69.3cm) 4 X 16 GB RDIMM, 2666 MT/s 2 X 1 TB 7.2K RPM SATA 6Gbps 3.5in Hot-plug Hard Drives; RAID 1 for H330+ Embedded NIC: 2 X 1GbE LOM Network Adapter 1: Broadcom 57412 Dual Port 10Gb SFP+ adapter Network Adapter 2: Broadcom 57416 Dual Port 10Gb Base-T adapter Power Additional Features 2 X Hot Plug Power Supplies 550W Fan fault tolerance; ECC memory; interactive LCD screen; ENERGY STAR® compliant Environment Temperature Continuous Temperature - Storage Relative Humidity Continuous Relative Humidity Storage Altitude Continuous Altitude Storage Specification 5°C to 40°C (41°F to 104°F) with no direct sunlight on the equipment -40°C to 65°C (-40°F to 149°F) with a maximum temperature gradation of 20°C per hour 5% to 85% with 29°C (84.2°F) maximum dew point 5% to 95% at a maximum wet bulb temperature of 33°C (91°F), atmosphere must be non-condensing at all times 3048m (10,000ft) 12,000m (39,370ft) 1.3 DMF Controller Node (DCA-DM-C450) Specification This section describes the LEDs provided for monitoring environmental and port status on the DMF Controller Node (DCA-DM-C450). 8 DMF Controller Nodes The DMF Controller Node (DCA-DM-C450) is available as an enterprise-class, 2-socket, 1-RU rack-mounted hardware appliance designed to deliver the right combination of performance, redundancy, and value in a high-density chassis. Figure 1-7: DMF Controller Node (DCA-DM-C450) Bezel 1 Controller Node Security Bezel 2 LCD menu buttons 3 LCD panel Figure 1-8: DMF Controller Node (DCA-DM-C450) Front Panel 1 System identification button / indicator 2 Video connector 3 USB ports 4 Power-on indicator / Power button 5 Micro USB (not supported) 6 Information tag 7 Hard drives 9 Figure 1-9: DMF Controller Node (DCA-DM-C450) Rear Panel 1.3.1 1 Ethernet connector 3 Not supported 2 Ethernet connector 4 10-GbE SFP+ packet capture port 3 Serial connector (Default Baud Rate 115200) 4 Ethernet connector 5 Not supported 5 Ethernet connector 6 Not supported 6 PSU status indicators 7 Power Supply 2 8 Power Supply 1 9 System identification indicator/button 10 Video connector 11 USB ports 12 iDRAC Ethernet interface 13 Ethernet connector 2 Controller Node management port 2 (10/100/1000 Mb/s) 14 Ethernet connector 1 Controller Node management port 1 (10/100/1000 Mb/s) LEDs and Indicators The following table lists the meaning of each LED or other indicator. 10 DMF Controller Nodes 1.3.2 Indicator, Button, or Connector Description Power-on indicator Green: System power is on Off: System power is off System identification indicator Off: Normal operating conditions in front panel Blue blinking: System identification has been activated System identification indicator Blue: Normal operation condition in rear panel Blue blinking: System identification has been activated Amber blinking: Fault detected with error code followed by descriptive text in LCD panel 10/100/1000 Mbps Ethernet connector 1, 2 Link indicator Green: A valid 1000 Mb/s network link is established Amber: A valid 10/100 Mb/s network link is established Off: Link is down Activity indicator Green blinking: Network data is being sent or received Off: No link activity 10G SFP+ Ethernet connector Link indicator 4 Green: A valid 10G network link is established Off: Link is down Activity indicator Green blinking: Network data is being sent or received Off: No link activity Power Supply status Green: A valid power source is connected to the power supply and the power supply is operational Amber blinking: Indicates a problem with the power supply Off: Power is off Platform Management Tool DMF Controller Node (DCA-DM-C450) supports iDRAC 9 platform management tools. · iDRAC 9 supported feature: remote power management, virtual console. 11 1.3.3 Technical Specification Controller Node Processor Form Factor (H X W X D) Memory Hard Drive Networking DCA-DM-C450 2 x Intel Xeon Silver 4310 2.10GHz, 12 Cores, 24 Threads, 10.4GT/s 2UPI, 18M Cache, Turbo, HT, 120W, DDR4-2666 1-RU Rack Server (4.28cm x 43.4cm x 69.3cm) 4 X 16 GB RDIMM, 3200 MT/s 2 X 2 TB 7.2K RPM SATA 6Gbps 3.5in Hot-plug Hard Drives; RAID 1 for H355 Embedded NIC: 2 X 1GbE LOM(BCM5720) Network Adapter 1: Intel X710 Dual Port 10Gb SFP+ adapter Network Adapter 2: Intel X710-T2L Dual Port 10Gb Base-T adapter Power Additional Features 2 X Hot Plug Power Supplies 800W Fan fault tolerance; ECC memory; interactive LCD screen; ENERGY STAR® compliant Environment Temperature Continuous Temperature - Storage Relative Humidity Continuous Relative Humidity Storage Altitude Continuous Altitude Storage Specification 5°C to 40°C (41°F to 104°F) with no direct sunlight on the equipment -40°C to 65°C (-40°F to 149°F) with a maximum temperature gradation of 20°C per hour 5% to 85% with 29°C (84.2°F) maximum dew point 5% to 95% at a maximum wet bulb temperature of 33°C (91°F), atmosphere must be non-condensing at all times 3048m (10,000ft) 12,000m (39,370ft) 12 Chapter 2 DMF Service Nodes This chapter describes the DMF Service Nodes available from Arista Networks. 2.1 DMF Service Node (DCA-DM-SC/DCA-DM-SC2) Specification This section describes the LEDs provided for monitoring environmental and port status on the DMF Service Node (DCA-DM-SC 960GB and1.2TB, DCA-DM-SC2, 960GB, currently shipped appliances will have 960GB SSD). The DMF Service Node (DCA-DM-SC/DCA-DM-SC2) is available as an enterprise-class, 2-socket, 1-RU rack-mounted hardware appliance designed to deliver the right combination of performance, redundancy, and value in a high-density chassis. It has 4 SNIs. Figure 2-1: DMF Service Node (DCA-DM-SC/DCA-DM-SC2 with 960GB SSD) Bezel 1 Controller Node Security Bezel 2 LCD menu buttons 3 LCD panel Figure 2-2: DMF Service Node (DCA-DM-SC/DCA-DM-SC2 with 960GB SSD) Front Panel 1 System identification button / indicator 2 Optical drive 3 Video connector 4 USB ports 5 Power-on indicator / Power button 6 Micro USB (not supported) 7 Information tag 8 Hard drive 13 Figure 2-3: DMF Service Node (DCA-DM-SC with 1.2TB HD) Bezel 1 Controller Node Security Bezel 2 LCD menu buttons 3 LCD panel Figure 2-4: DMF Service Node (DCA-DM-SC with 1.2TB HD) Front Panel 1 System identification button / indicator 2 Optical drive 3 Video connector 4 USB ports 5 Power-on indicator / Power button 6 Micro USB (not supported) 7 Information tag 8 Hard drive 14 Figure 2-5: DMF Service Node (DCA-DM-SC/DCA-DM-SC2) Rear Panel DMF Service Nodes 2.1.1 1 Ethernet connector 5 10-GbE SFP+ Service interfaces SNI1 2 Ethernet connector 6 10-GbE SFP+ Service interfaces SNI2 3 Ethernet connector 7 10-GbE SFP+ Service interfaces SNI4 4 Ethernet connector 8 10-GbE SFP+ Service interfaces SNI3 5 PSU status indicators 6 Power Supply 2 7 Power Supply 1 8 Ethernet connector 4 Service Node management port 2 (10/100/1000 Mb/s) 9 Ethernet connector 3 Service Node management port 1 (10/100/1000 Mb/s) 10 Ethernet connector 2 Not supported 11 Ethernet connector 1 Not supported 12 USB ports 13 Video connector 14 Serial connector (Default Baud Rate 115200) 15 iDRAC Ethernet interface 16 System identification button 17 System identification indicator LEDs and Indicators The following table lists the meaning of each LED or other indicator. 15 2.1.2 Indicator, Button, or Connector Description Power-on indicator Green: System power is on Off: System power is off System identification indicator Off: Normal operating conditions in front panel Blue blinking: System identification has been activated System identification indicator Blue: Normal operation condition in rear panel Blue blinking: System identification has been activated Amber blinking: Fault detected with error code followed by descriptive text in LCD panel 10/100/1000 Mbps Ethernet connector 3, 4 Link indicator Green: A valid 1000 Mb/s network link is established Amber: A valid 10/100 Mb/s network link is established Off: Link is down Activity indicator Green blinking: Network data is being sent or received Off: No link activity 10G SFP+ Service node Ethernet Link indicator Green: A valid 10G network link is established connectors SNI1-4 Off: Link is down Activity indicator Green blinking: Network data is being sent or received Off: No link activity Power Supply status Green: A valid power source is connected to the power supply and the power supply is operational. Amber blinking: Indicates a problem with the power supply Off: Power is off Platform Management Tool DMF Service Node (DCA-DM-SC/DCA-DM-SC2) supports iDRAC 9 platform management tools. · iDRAC 9 supported feature: remote power management, virtual console. 16 2.1.3 DMF Service Nodes Technical Specification Controller Node Processor Form Factor (H X W X D) Memory Hard Drive Networking DCA-DM-SC with 960GB SSD 1 X Intel Xeon Gold 5118 2.30GHz, 16.5M Cache, 10.4GT/s 2UPI, Turbo, HT, 12C/24T, 105W, DDR4-2400 1-RU Rack Server (4.28cm x 43.4cm x 75.7cm) 6 X 8 GB RDIMM, 3200 MT/s 960GB SSD SATA Mix Use 6Gbps 512n 2.5in Hot-plug AG Hard Drive Embedded NIC: Intel X710 Dual Port 10Gb DA/SFP+, I350 Dual Port 1Gb Ethernet LOM Network Adapter 1: Intel X710 Dual Port 10Gb DA/SFP+ server adapter Network Adapter 2: Intel X710 Dual Port 10Gb DA/SFP+ server adapter Power Additional Features 2 X Hot Plug Power Supplies 1100W Fan fault tolerance; ECC memory; interactive LCD screen; ENERGY STAR® compliant Controller Node Processor Form Factor (H X W X D) Memory Hard Drive Networking Power Additional Features DCA-DM-SC2 with 960GB SSD 1 X Intel Xeon Gold 5118 2.30GHz, 16.5M Cache, 10.4GT/s 2UPI, Turbo, HT, 12C/24T, 105W, DDR4-2400 1-RU Rack Server (4.28cm x 43.4cm x 75.7cm) 6 X 8 GB RDIMM, 3200 MT/s 960GB SSD SATA Mix Use 6Gbps 512n 2.5in Hot-plug AG Hard Drive Embedded NIC: Intel X710 Dual Port 10Gb DA/SFP+, I350 Dual Port 1Gb Ethernet LOM Network Adapter 1: Intel XXV710 V2 Dual Port 10Gb DA/SFP+ server adapter Network Adapter 2: Intel XXV710 V2 Dual Port 10Gb DA/SFP+ server adapter 2 X Hot Plug Power Supplies 1100W Fan fault tolerance; ECC memory; interactive LCD screen; ENERGY STAR® compliant 17 Controller Node Processor Form Factor (H X W X D) Memory Hard Drive Networking Power Additional Features DCA-DM-SC with 1.2TB HD 1 X Intel Xeon Gold 5118 2.30GHz, 16.5M Cache, 10.4GT/s 2UPI, Turbo, HT, 12C/24T, 105W, DDR4-2400 1-RU Rack Server (4.28cm x 43.4cm x 75.7cm) 6 X 8 GB RDIMM, 3200 MT/s 1.2 TB 10K RPM SAS 12Gbps 512n 2.5in Hot-plug Hard Drives; No RAID for H330 Embedded NIC: Intel X710 Dual Port 10Gb DA/SFP+, I350 Dual Port 1Gb Ethernet LOM Network Adapter 1: Intel X710 Dual Port 10Gb DA/SFP+ server adapter Network Adapter 2: Intel X710 Dual Port 10Gb DA/SFP+ server adapter 2 X Hot Plug Power Supplies 1100W Fan fault tolerance; ECC memory; interactive LCD screen; ENERGY STAR® compliant Environment Temperature Continuous Temperature - Storage Relative Humidity Continuous Relative Humidity Storage Altitude Continuous Altitude Storage Specification 5°C to 40°C (41°F to 104°F) with no direct sunlight on the equipment -40°C to 65°C (-40°F to 149°F) with a maximum temperature gradation of 20°C per hour 5% to 85% with 29°C (84.2°F) maximum dew point 5% to 95% at a maximum wet bulb temperature of 33°C (91°F), atmosphere must be non-condensing at all times 3048m (10,000ft) 12,000m (39,370ft) 2.2 DMF Service Node (DCA-DM-SDL/DCA-DM-SDL2) Specification The DMF Service Node (DCA-DM-SDL/DCA-DM-SDL2) is available as an enterprise-class, 2-socket, 2RU rack-mount hardware appliance designed for high density, performance, redundancy, and value. It has 16 SNIs. 18 DMF Service Nodes This section describes the LEDs provided for monitoring environmental and port status on the DMF Service Node (DCA-DM-SDL 960GB and 1.2TB, DCA-DM-SDL2 960GB. Currently shipped appliances will have 960GB SSD). Figure 2-6: DMF Service Node (DCA-DM-SDL/DCA-DM-SDL2 with 960GB SSD) Bezel 1 System identification button / indicator 2 Service Node Security Bezel 3 Power-on indicator / Power button 4 USB ports Figure 2-7: DMF Service Node (DCA-DM-SDL/DCA-DM-SDL2 with 960GB SSD) Front Panel 1 Front video connector 2 Micro USB (not supported) 3 Information tag 4 Hard drive Figure 2-8: DMF Service Node (DCA-DM-SDL with 1.2TB HD) Bezel 19 1 System identification button / indicator 2 Service Node Security Bezel 3 LCD menu buttons 4 LCD panel 5 Power-on indicator / Power button 6 USB ports Figure 2-9: DMF Service Node (DCA-DM-SDL with 1.2TB HD) Front Panel 1 Front video connector 2 Micro USB (not supported) 3 Information tag 4 Hard drive Figure 2-10: DMF Service Node (DCA-DM-SDL) Rear Panel 20 DMF Service Nodes 1 Service interfaces SNI8 2 Service interfaces SNI7 3 Service interfaces SNI6 4 Service interfaces SNI5 5 Service interfaces SNI4 6 Service interfaces SNI3 7 Service interfaces SNI2 8 Service interfaces SNI1 9 Service interfaces SNI12 10 Service interfaces SNI11 11 Service interfaces SNI10 12 Service interfaces SNI9 13 Service interfaces SNI13 14 Service interfaces SNI14 15 Service interfaces SNI15 16 Service interfaces SNI16 17 Power Supply 2 18 PSU status indicator 19 Power Supply 1 20 Ethernet connector 4 Service Node management port 2 (10/100/1000 Mb/s) 21 Ethernet connector 3 Service Node management port 1 (10/100/1000 Mb/s) 22 Ethernet connector 2 Not supported 23 Ethernet connector 1 Not supported 24 USB ports 25 Rear video connector 26 Serial connector (Default Baud Rate 115200) 27 iDRAC Ethernet interface 28 System identification button 29 System identification indicator Figure 2-11: DMF Service Node (DCA-DM-SDL2) Rear Panel The following lists the meaning of the callouts in the rear panel. 21 2.2.1 1 Service interfaces SNI4 2 Service interfaces SNI3 3 Service interfaces SNI8 4 Service interfaces SNI7 5 Service interfaces SNI2 6 Service interfaces SNI14 7 Service interfaces SNI13 8 Service interfaces SNI10 9 Service interfaces SNI9 10 Service interfaces SNI1 11 Service interfaces SNI11 12 Service interfaces SNI12 13 Service interfaces SNI15 14 Service interfaces SNI16 15 Power Supply 2 16 PSU status indicator 17 Power Supply 1 18 Ethernet connector 4 Service Node management port 2 (10/100/1000 Mb/s) 19 Ethernet connector 3 Service Node management port 1 (10/100/1000 Mb/s) 20 Ethernet connector 2 Not supported 21 Ethernet connector 1 Not supported 22 USB ports 23 Rear video connector 24 Serial connector (Default Baud Rate 115200) 25 iDRAC Ethernet interface 26 System identification button 27 System identification indicator 28 Service interfaces SNI5 29 Service interfaces SNI6 LEDs and Indicators The following table lists the meaning of each LED or other indicator. 22 DMF Service Nodes 2.2.2 Indicator, Button, or Connector Description Power-on indicator Green: System power is on Off: System power is off LED panel Blue background: Normal operating conditions Amber background: Fault detected with error code followed by descriptive text System identification indicator Off: Normal operating conditions in front panel Blue blinking: System identification has been activated System identification indicator Blue: Normal operation condition in rear panel Blue blinking: System identification has been activated Amber blinking: Fault detected with error code followed by descriptive text in LCD panel 10/100/1000 Mbps Ethernet connector 1, 2 Link indicator Green: A valid 1000 Mb/s network link is established Amber: A valid 10/100 Mb/s network link is established Off: Link is down Activity indicator Green blinking: Network data is being sent or received Off: No link activity 10G SFP+ Service node Link indicator Ethernet connectors SNI1-16 Green: A valid 10G network link is established Off: Link is down Activity indicator Green blinking: Network data is being sent or received Off: No link activity Power Supply status Green: A valid power source is connected to the power supply and the power supply is operational. Amber blinking: Indicates a problem with the power supply Off: Power is off Platform Management Tool DMF Service Node (DCA-DM-SDL/DCA-DM-SDL2) supports iDRAC 9 platform management tools. · iDRAC 9 supported feature: remote power management, virtual console. 23 2.2.3 Technical Specification Service Node Processor Form Factor (H X W X D) Memory Hard Drive Networking DCA-DM-SDL with 960GB SSD 2 X Intel Xeon Silver 4116 2.1GHz, 16M Cache, 9.6GT/s 2UPI, Turbo, HT, 12C/24T, 85W, DDR4-2400 2U Rack Server (8.68cm x 43.40cm x 73.75cm) 12 X 8GB RDIMM, 3200 MT/s, Single Rank 960GB SSD SATA Mix Use 6Gbps 512n 2.5in Hot-plug AG Drives Embedded NIC: Intel X710 DP 10Gb DA/SFP+, +I350 DP 1Gb Ethernet Daughter card Network Adapter: 4 X Intel X710 Quad Port 10Gb DA/SFP+, Converged Network Adapters Power Additional Features Dual, Hot-plug, Redundant Power Supplies (1+1) 1100W Fan fault tolerance; ECC memory; interactive LCD screen; ENERGY STAR® compliant Service Node Processor Form Factor (H X W X D) Memory Hard Drive Networking Power Additional Features DCA-DM-SDL2 with 960GB SSD 2 X Intel Xeon Silver 4116 2.1GHz, 16M Cache, 9.6GT/s 2UPI, Turbo, HT, 12C/24T, 85W, DDR4-2400 2U Rack Server (8.68cm x 43.40cm x 73.75cm) 12 X 8GB RDIMM, 3200 MT/s, Single Rank 960GB SSD SATA Mix Use 6Gbps 512n 2.5in Hot-plug AG Drives Embedded NIC: Intel X710 DP 10Gb DA/SFP+, +I350 DP 1Gb Ethernet Daughter card Network Adapter: 8 X Intel XXV710 Dual Port 10/25GbE AFP28 PCIe Adapters Dual, Hot-plug, Redundant Power Supplies (1+1) 1100W Fan fault tolerance; ECC memory; interactive LCD screen; ENERGY STAR® compliant 24 Service Node Processor Form Factor (H X W X D) Memory Hard Drive Networking Power Additional Features DMF Service Nodes DCA-DM-SDL with 1.2TB HD 2 X Intel Xeon Silver 4116 2.1GHz, 16M Cache, 9.6GT/s 2UPI, Turbo, HT, 12C/24T, 85W, DDR4-2400 2U Rack Server (8.68cm x 43.40cm x 73.75cm) 12 X 8GB RDIMM, 3200 MT/s, Single Rank 1.2TB 10K RPM SAS 12Gbps 512n 2.5in Hot-plug Hard Drives Embedded NIC: Intel X710 DP 10Gb DA/SFP+, +I350 DP 1Gb Ethernet Daughter card Network Adapter: 4 X Intel X710 Quad Port 10Gb DA/SFP+, Converged Network Adapters Dual, Hot-plug, Redundant Power Supplies (1+1) 1100W Fan fault tolerance; ECC memory; interactive LCD screen; ENERGY STAR® compliant Environment Temperature Continuous Temperature - Storage Relative Humidity Continuous Relative Humidity Storage Altitude Continuous Altitude Storage Specification 10°C to 35°C (50°F to 95°F) with no direct sunlight on the equipment -40°C to 65°C (-40°F to 149°F) with a maximum temperature gradation of 20°C per hour 10% to 80% with 29°C (84.2°F) maximum dew point 5% to 95% relative humidity with 33°C (91°F) maximum dew point, atmosphere must be non-condensing at all times 3048m (10,000ft) 12,000m (39,370ft) 2.3 DMF Service Node (DCA-DM-SEL) Specification This section describes the LEDs provided for monitoring environmental and port status on the DMF Service Node (DCA-DM-SEL 960GB and 1.2TB, currently shipped appliances will have 960GB SSD). 25 The DMF Service Node (DCA-DM-SEL) is available as an enterprise-class, 2-socket, 2RU rack-mount hardware appliance designed for high density, performance, redundancy, and value. It has 16 SNIs. Figure 2-12: DMF Service Node (DCA-DM-SEL with 960GB SSD) Bezel 1 System identification button / indicator 2 Service Node Security Bezel 3 Power-on indicator / Power button 4 USB ports Figure 2-13: DMF Service Node (DCA-DM-SEL with 960GB SSD) Front Panel 1 Front video connector 2 Micro USB (not supported) 3 Information tag 4 Hard drive Figure 2-14: DMF Service Node (DCA-DM-SEL with 1.2TB HD) Bezel 26 DMF Service Nodes 1 System identification button / indicator 2 Service Node Security Bezel 3 LCD menu buttons 4 LCD panel 5 Power-on indicator / Power button 6 USB ports Figure 2-15: DMF Service Node (DCA-DM-SEL with 1.2TB HD) Front Panel) 1 Front video connector 2 Micro USB (not supported) 3 Micro USB (not supported) 4 Hard drive 27 Figure 2-16: DMF Service Node (DCA-DM-SEL) Rear Panel 2.3.1 The following lists the meaning of the callouts in the rear panel. 1 Service interfaces SNI4 2 Service interfaces SNI3 3 Service interfaces SNI8 4 Service interfaces SNI7 5 Service interfaces SNI2 6 Service interfaces SNI14 7 Service interfaces SNI13 8 Service interfaces SNI10 9 Service interfaces SNI9 10 Service interfaces SNI1 11 Service interfaces SNI11 12 Service interfaces SNI12 13 Service interfaces SNI15 14 Service interfaces SNI16 15 Power Supply 2 16 PSU status indicator 17 Power Supply 1 18 Ethernet connector 4 Service Node management port 2 (10/100/1000 Mb/s) 19 Ethernet connector 3 Service Node management port 1 (10/100/1000 Mb/s) 20 Ethernet connector 2 Not supported 21 Ethernet connector 1 Not supported 22 USB ports 23 Rear video connector 24 Serial connector (Default Baud Rate 115200) 25 iDRAC Ethernet interface 26 System identification button 27 System identification indicator 28 Service interfaces SNI5 29 Service interfaces SNI6 LEDs and Indicators The following table lists the meaning of each LED or other indicator. 28 DMF Service Nodes 2.3.2 Indicator, Button, or Connector Description Power-on indicator Green: System power is on Off: System power is off LED panel Blue background: Normal operating conditions Amber background: Fault detected with error code followed by descriptive text System identification indicator Off: Normal operating conditions in front panel Blue blinking: System identification has been activated System identification indicator Blue: Normal operation condition in rear panel Blue blinking: System identification has been activated Amber blinking: Fault detected with error code followed by descriptive text in LCD panel 10/100/1000 Mbps Ethernet connector 1, 2 Link indicator Green: A valid 1000 Mb/s network link is established Amber: A valid 10/100 Mb/s network link is established Off: Link is down Activity indicator Green blinking: Network data is being sent or received Off: No link activity 25G SFP+ Service node Link indicator Ethernet connectors SNI1-16 Green: A valid 25G network link is established Off: Link is down Activity indicator Green blinking: Network data is being sent or received Off: No link activity Power Supply status Green: A valid power source is connected to the power supply and the power supply is operational. Amber blinking: Indicates a problem with the power supply Off: Power is off Platform Management Tool DMF Service Node (DCA-DM-SEL) supports iDRAC 9 platform management tools. · iDRAC 9 supported feature: remote power management, virtual console. 29 2.3.3 Technical Specification Service Node Processor Form Factor (H X W X D) Memory Hard Drive Networking DCA-DM-SEL with 960GB SSD 2 X Intel Xeon Gold 6248 2.5GHz, 27.5M Cache, 10.4GT/s, Turbo, HT, 20C/40T, 150W, DDR4-2933 2U Rack Server (8.68cm x 43.40cm x 73.75cm) 24 X 16GB RDIMM, 2933 MT/s, Dual Rank 960GB SSD SATA Mix Use 6Gbps 512 2.5in Hot-plug AG Drive Embedded NIC: Intel X710 DP 10Gb DA/SFP+, +I350 DP 1Gb Ethernet Daughter card Network Adapter: 8 X Intel XXV710 Dual Port 10/25GbE SFP28 PCIe Adapters Power Additional Features Dual, Hot-plug, Redundant Power Supplies (1+1) 1100W Fan fault tolerance; ECC memory; interactive LCD screen; ENERGY STAR® compliant Service Node Processor Form Factor (H X W X D) Memory Hard Drive Networking Power Additional Features DCA-DM-SEL with 1.2TB HD 2 X Intel Xeon Gold 6248 2.5GHz, 27.5M Cache, 10.4GT/s, Turbo, HT, 20C/40T, 150W, DDR4-2933 2U Rack Server (8.68cm x 43.40cm x 73.75cm) 24 X 16GB RDIMM, 2933 MT/s, Dual Rank 1.2HD 10K RPM SAS 12Gbps 512 2.5in Hot-plug Hard Drive Embedded NIC: Intel X710 DP 10Gb DA/SFP+, +I350 DP 1Gb Ethernet Daughter card Network Adapter: 8 X Intel XXV710 Dual Port 10/25GbE SFP28 PCIe Adapters Dual, Hot-plug, Redundant Power Supplies (1+1) 1100W Fan fault tolerance; ECC memory; interactive LCD screen; ENERGY STAR® compliant 30 DMF Service Nodes Environment Temperature Continuous Temperature - Storage Relative Humidity Continuous Relative Humidity Storage Altitude Continuous Altitude Storage Specification 10°C to 35°C (50°F to 95°F) with no direct sunlight on the equipment -40°C to 65°C (-40°F to 149°F) with a maximum temperature gradation of 20°C per hour 10% to 80% with 29°C (84.2°F) maximum dew point 5% to 95% relative humidity with 33°C (91°F) maximum dew point, atmosphere must be non-condensing at all times 3048m (10,000ft) 12,000m (39,370ft) 31 Chapter 3 Arista Analytics Nodes This chapter describes the Arista Analytics Nodes available from Arista Networks. 3.1 Arista Analytics Node (DCA-DM-AA/DCA-DM-AA2/DCA-DM-AA3) Specification This section describes the LEDs provided for monitoring environmental and port status on the Arista Analytics Node (DCA-DM- AA/DCA-DM-AA2/DCA-DM-AA3). The Arista Analytics Node (DCA-DM-AA/DCA-DM-AA2/DCA-DM-AA3) is available as an enterprise-class, 2-socket, 1 RU rack-mounted hardware appliance designed to deliver the right combination of performance, redundancy, and value in a high-density chassis. Figure 3-1: Arista Analytics Node (DCA-DM-AA/DCA-DM-AA2/DCA-DM-AA3) Bezel 1 Analytics Node Security Bezel 2 LCD menu buttons 3 LCD panel Figure 3-2: Arista Analytics Node (DCA-DM-AA/DCA-DM-AA2/DCA-DM-AA3) Front Panel 1 System identification button / indicator 2 Optical drive 3 Video connector 4 USB ports 5 Power-on indicator / Power button 6 Micro USB (not supported) 7 Information tag 8 Hard drives 32 Arista Analytics Nodes Figure 3-3: Arista Analytics Node (DCA-DM-AA/DCA-DM-AA2/DCA-DM-AA3) Rear Panel 3.1.1 The following lists the meaning of the callouts in the rear panel. 1 Serial connector (Default Baud Rate 115200) 9 Power Supply 2 2 iDRAC Ethernet interface 10 Power Supply 1 3 Ethernet connector 1 Analytics Node management port 1, Active (10/100/1000 Mb/s) 11 Ethernet connector 2 Analytics Node management port 2, Backup (10/100/1000 Mb/s) 4 Ethernet connector 3 Analytics Node 10- 12 USB ports GbE SFP+ Collector Interface 1, Active 5 Ethernet connector 4 Analytics Node 10- 13 Video connector GbE SFP+ Collector Interface 2, Backup 6 Ethernet connector 5 Not supported 7 Ethernet connector 6 Not supported 8 PSU status indicators 14 System identification button 15 System identification indicator LEDs and Indicators The following table lists the meaning of each LED or other indicator. 33 3.1.2 Indicator, Button, or Connector Description Power-on indicator Green: System power is on Off: System power is off System identification indicator Off: Normal operating conditions in front panel Blue blinking: System identification has been activated System identification indicator Blue: Normal operation condition in rear panel Blue blinking: System identification has been activated Amber blinking: Fault detected with error code followed by descriptive text in LCD panel 10/100/1000 Mbps Ethernet connector 1, 2 Link indicator Green: A valid 1000 Mb/s network link is established Amber: A valid 10/100 Mb/s network link is established Off: Link is down Activity indicator Green blinking: Network data is being sent or received Off: No link activity 10G SFP+ Ethernet connector Link indicator 3, 4 Green: A valid 10G network link is established Off: Link is down Activity indicator Green blinking: Network data is being sent or received Off: No link activity Power Supply status Green: A valid power source is connected to the power supply and the power supply is operational. Amber blinking: Indicates a problem with the power supply Off: Power is off Platform Management Tool Arista Analytics Node (DCA-DM-AA/DCA-DM-AA2/DCA-DM-AA3) supports iDRAC 9 platform management tools. · iDRAC 9 supported feature: Remote power management, virtual console. 34 3.1.3 Arista Analytics Nodes Technical Specification Analytics Node Processor Form Factor (H X W X D) Memory Hard Drive DCA-DM-AA/DCA-DM-AA2/DCA-DM-AA3 2 x Intel Xeon Silver 4114 2.20GHz, 10 Cores, 20 Threads, 9.6GT/s 2UPI, 14M Cache, Turbo, HT, 85W, DDR4-2400 1-RU Rack Server (4.28cm x 43.4cm x 69.3cm) 8 X 16 GB RDIMM, 2666 MT/s 2 X 960 GB SSD SAS Hot-plug Drive 2 X 1 TB 7.2K RPM SATA 6Gbps 3.5in Hot-plug Hard Drives; No RAID, PERC H330+ Networking Embedded NIC: 2 X 1GbE LOM Network Adapter 1: Intel X710 Dual Port 10Gb DA/SFP+ server adapter Network Adapter 2: Intel X550 Dual Port 10Gb Base-T server adapter Power Additional Features 2 X Hot Plug Power Supplies 550W Fan fault tolerance; ECC memory; interactive LCD screen; ENERGY STAR® compliant Environment Temperature Continuous Temperature - Storage Relative Humidity Continuous Relative Humidity Storage Altitude Continuous Altitude Storage Specification 5°C to 40°C (41°F to 104°F) with no direct sunlight on the equipment -40°C to 65°C (-40°F to 149°F) with a maximum temperature gradation of 20°C per hour 5% to 85% with 29°C (84.2°F) maximum dew point 5% to 95% at a maximum wet bulb temperature of 33°C (91°F), atmosphere must be non-condensing at all times 3048m (10,000ft) 12,000m (39,370ft) 3.2 Arista Analytics Node (DCA-DM-AN450) Specification This section describes the LEDs provided for monitoring environmental and port status on the Arista Analytics Node (DCA-DM- AN450). 35 The Arista Analytics Node (DCA-DM-AN450) is available as an enterprise-class, 2-socket, 1-RU rackmounted hardware appliance designed to deliver the right combination of performance, redundancy, and value in a high-density chassis. Figure 3-4: DMF Analytics Node (DCA-DM-AN450) Bezel 1 Controller Node Security Bezel 2 LCD menu buttons 3 LCD panel Figure 3-5: DMF Analytics Node (DCA-DM-AN450) Front Panel 1 System identification button / indicator 2 Video connector 3 USB ports 4 Power-on indicator / Power button 5 Micro USB (not supported) 6 Information tag 7 Hard drives 36 Figure 3-6: DMF Analytics Node (DCA-DM-AN450) Rear Panel Arista Analytics Nodes 3.2.1 1 Ethernet connector 3 Analytics Node 10- 8 Power Supply 1 GbE SFP+ Collector Interface 1, Active 2 Ethernet connector 4 Analytics Node 10- 9 System identification indicator/button GbE SFP+ Collector Interface 2, Backup 3 Serial connector (Default Baud Rate 115200) 10 Video connector 4 Ethernet connector 5 Not supported 11 USB ports 5 Ethernet connector 6 Not supported 12 iDRAC Ethernet interface 6 PSU status indicators 13 Ethernet connector 2 Analytics Node management port 2 (10/100/1000 Mb/s) 7 Power Supply 2 14 Ethernet connector 1 Analytics Node management port 1 (10/100/1000 Mb/s) LEDs and Indicators The following table lists the meaning of each LED or other indicator. 37 3.2.2 Indicator, Button, or Connector Description Power-on indicator Green: System power is on Off: System power is off System identification indicator Off: Normal operating conditions in front panel Blue blinking: System identification has been activated System identification indicator Blue: Normal operation condition in rear panel Blue blinking: System identification has been activated Amber blinking: Fault detected with error code followed by descriptive text in LCD panel 10/100/1000 Mbps Ethernet connector 1, 2 Link indicator Green: A valid 1000 Mb/s network link is established Amber: A valid 10/100 Mb/s network link is established Off: Link is down Activity indicator Green blinking: Network data is being sent or received Off: No link activity 10G SFP+ Ethernet connector Link indicator 4 Green: A valid 10G network link is established Off: Link is down Activity indicator Green blinking: Network data is being sent or received Off: No link activity Power Supply status Green: A valid power source is connected to the power supply and the power supply is operational Amber blinking: Indicates a problem with the power supply Off: Power is off Platform Management Tool Arista Analytics Node (DCA-DM-AN450) supports iDRAC 9 platform management tools. · iDRAC 9 supported feature: remote power management, virtual console. 38 3.2.3 Arista Analytics Nodes Technical Specification Analytics Node Processor Form Factor (H X W X D) Memory Hard Drive DCA-DM-AN450 2 x Intel Xeon Silver 4310 2.10GHz, 12 Cores, 24 Threads, 10.4GT/s 2UPI, 18M Cache, Turbo, HT, 120W, DDR4-2666 1-RU Rack Server (4.28cm x 43.4cm x 69.3cm) 8 X 16 GB RDIMM, 3200 MT/s 2 X 1.92 TB SSD vSAS Mixed Use 12Gbps 3.5in; AG Drive SED, 3DWPD 2 X 2 TB 7.2K RPM SATA 6Gbps 3.5in Hot-plug Hard Drives; No RAID, PERC H355 Networking Embedded NIC: 2 X 1GbE LOM(BCM5720) Network Adapter 1: Intel X710 Dual Port 10Gb SFP+ adapter Network Adapter 2: Intel X710-T2L Dual Port 10Gb Base-T adapter Power Additional Features 2 X Hot Plug Power Supplies 800W Fan fault tolerance; ECC memory; interactive LCD screen; ENERGY STAR® compliant Environment Temperature Continuous Temperature - Storage Relative Humidity Continuous Relative Humidity Storage Altitude Continuous Altitude Storage Specification 5°C to 40°C (41°F to 104°F) with no direct sunlight on the equipment -40°C to 65°C (-40°F to 149°F) with a maximum temperature gradation of 20°C per hour 5% to 85% with 29°C (84.2°F) maximum dew point 5% to 95% at a maximum wet bulb temperature of 33°C (91°F), atmosphere must be non-condensing at all times 3048m (10,000ft) 12,000m (39,370ft) 39 Chapter 4 DMF Recorder Nodes This chapter describes the DMF Recorder Nodes available from Arista Networks. 4.1 DMF Recorder Node (DCA-DM-RA) Specification This section describes the LEDs provided for monitoring environmental and port status on the DMF Recorder Node (DCA-DM-RA). The DMF Recorder Node (DCA-DM-RA) is available as an enterprise-class, 2-socket, 2-RU rack-mounted hardware appliance designed to deliver the right combination of performance, redundancy, and value in a high-density chassis. It has 160TB data storage capacity. Figure 4-1: DMF Recorder Node (DCA-DM-RA) Bezel 1 System identification button / indicator 2 Recorder Node Security Bezel 3 LCD menu buttons 4 LCD panel 5 Power-on indicator / Power button 6 USB ports 40 Figure 4-2: DMF Recorder Node (DCA-DM-RA) Front Panel DMF Recorder Nodes 1 Information tag 2 Video connector 3 Micro USB (not supported) 4 Hard drives Figure 4-3: DMF Recorder Node (DCA-DM-RA) Rear Panel 1 Ethernet connector 1 Not Supported 2 Ethernet connector 2 10-GbE SFP+ Recorder Interface 3 SSD drives 4 Power Supply 1 5 Power Supply 2 6 PSU status indicators 7 Ethernet connector 6 Not supported 8 Ethernet connector 5 Not supported 9 Ethernet connector 4 Recorder Node management port 2, Backup (10/100/1000 Mb/s) 10 Ethernet connector 3 Recorder Node management port 1, Active (10/100/1000 Mb/s) 11 USB ports 12 Video connector 13 Serial connector (Default Baud Rate 115200) 14 iDRAC Ethernet interface 15 System identification button 16 System identification indicator 41 4.1.1 4.1.2 LEDs and Indicators The following table lists the meaning of each LED or other indicator. Indicator, Button, or Connector Description Power-on indicator Green: System power is on Off: System power is off System identification indicator Off: Normal operating conditions in front panel Blue blinking: System identification has been activated System identification indicator Blue: Normal operation condition in rear panel Blue blinking: System identification has been activated Amber blinking: Fault detected with error code followed by descriptive text in LCD panel 10/100/1000 Mbps Ethernet connector 3, 4 Link indicator Green: A valid 1000 Mb/s network link is established Amber: A valid 10/100 Mb/s network link is established Off: Link is down Activity indicator Green blinking: Network data is being sent or received Off: No link activity 10G SFP+ Ethernet connector Link indicator 2 Green: A valid 10G network link is established Off: Link is down Activity indicator Green blinking: Network data is being sent or received Off: No link activity Power Supply status Green: A valid power source is connected to the power supply and the power supply is operational. Amber blinking: Indicates a problem with the power supply Off: Power is off Platform Management Tool DMF Recorder Node (DCA-DM-RA) supports iDRAC 9 platform management tools. · iDRAC 9 supported feature: Remote power management, virtual console. 42 4.1.3 DMF Recorder Nodes Technical Specification Recorder Node Processor Form Factor (H X W X D) Memory Hard Drive DCA-DM-RA 2 x Intel Xeon Gold 6136 3.0GHz, 12 Cores, 24 Threads, 10.4GT/s 2UPI, 24.75M Cache, Turbo, HT, 150W, DDR4-2666 2-RU Rack Server (8.68cm x 43.4cm x 71.6cm) 12 X 16 GB RDIMM, 2666 MT/s, Dual Rank 12 X 10 TB 7.2K RPM NLSAS 12Gbps 512e 3.5in Hot-plug Hard Drives 4 X 10 TB 7.2K RPM NLSAS 12Gbps 512e 3.5in Internal Hard Drives 2 X 3.84TB SSD SAS Read Intensive 12Gb 512e 2.5in Flex Bay Drives Networking Embedded NIC: Intel X550 Dual Port 10Gb Base-T + I350 Dual Port 1Gb Base-T rNDC adapter Network Adapter 1: Intel X710 Dual Port 10Gb DA/SFP+ server adapter Power Additional Features 2 X Hot Plug Power Supplies 1100W Fan fault tolerance; ECC memory; interactive LCD screen; ENERGY STAR® compliant Environment Temperature Continuous Temperature - Storage Relative Humidity Continuous Relative Humidity Storage Altitude Continuous Altitude Storage Specification 10°C to 35°C (50°F to 95°F) with no direct sunlight on the equipment -40°C to 65°C (-40°F to 149°F) with a maximum temperature gradation of 20°C per hour 10% to 80% with 29°C (84.2°F) maximum dew point 5% to 95% RH with 33°C (91°F) maximum dew point, atmosphere must be non-condensing at all times 3048m (10,000ft) 12,000m (39,370ft) 4.2 DMF Recorder Node (DCA-DM-RA2) Specification This section describes the LEDs provided for monitoring environmental and port status on the DMF Recorder Node (DCA-DM-RA2). 43 The DMF Recorder Node (DCA-DM-RA2) is available as an enterprise-class, 2-socket, 2-RU rack-mounted hardware appliance designed to deliver the right combination of performance, redundancy, and value in a high-density chassis. It has 160TB data storage capacity. Figure 4-4: DMF Recorder Node (DCA-DM-RA2) Bezel 1 System identification button / indicator 2 Recorder Node Security Bezel 3 LCD menu buttons 4 LCD panel 5 Power-on indicator / Power button 6 USB ports Figure 4-5: DMF Recorder Node (DCA-DM-RA2) Front Panel 1 Information tag 2 Video connector 3 Micro USB (not supported) 4 Hard drives 44 Figure 4-6: DMF Recorder Node (DCA-DM-RA2) Rear Panel DMF Recorder Nodes 4.2.1 1 Ethernet connector 1 Not Supported 9 Ethernet connector 4 Recorder Node management port 2, Backup (10/100/1000 Mb/s) 2 Ethernet connector 2 10/25-GbE SFP28 10 Ethernet connector 3 Recorder Node Recorder Interface management port 1, Active (10/100/1000 Mb/s) 3 SSD drives 11 USB ports 4 Power Supply 1 12 Video connector 5 Power Supply 2 13 Serial connector (Default Baud Rate 115200) 6 PSU status indicators 14 iDRAC Ethernet interface 7 Ethernet connector 6 Not supported 8 Ethernet connector 5 Not supported 15 System identification button 16 System identification indicator LEDs and Indicators The following table lists the meaning of each LED or other indicator. 45 4.2.2 Indicator, Button, or Connector Description Power-on indicator Green: System power is on Off: System power is off System identification indicator Off: Normal operating conditions in front panel Blue blinking: System identification has been activated System identification indicator Blue: Normal operation condition in rear panel Blue blinking: System identification has been activated Amber blinking: Fault detected with error code followed by descriptive text in LCD panel 10/100/1000 Mbps Ethernet connector 3, 4 Link indicator Green: A valid 1000 Mb/s network link is established Amber: A valid 10/100 Mb/s network link is established Off: Link is down Activity indicator Green blinking: Network data is being sent or received Off: No link activity 10G/25G SFP28 Ethernet connector 2 Link indicator Green: A valid 25G network link is established Amber: A valid 10G network link is established Green blinking: Recorder port indicator - no transceiver detected or link is down Activity indicator Green blinking: Network data is being sent or received Off: No link activity Power Supply status Green: A valid power source is connected to the power supply and the power supply is operational. Amber blinking: Indicates a problem with the power supply Off: Power is off Platform Management Tool DMF Recorder Node (DCA-DM-RA2) supports iDRAC 9 platform management tools. · iDRAC 9 supported feature: Remote power management, virtual console. 46 4.2.3 DMF Recorder Nodes Technical Specification Recorder Node Processor Form Factor (H X W X D) Memory Hard Drive DCA-DM-RA2 2 x Intel Xeon Gold 6248 2.5GHz, 20 Cores, 40 Threads, 10.4GT/s, 27.5M Cache, Turbo, HT, 150W, DDR4-2933 2-RU Rack Server (8.68cm x 43.4cm x 71.6cm) 12 X 16 GB RDIMM, 2933 MT/s, Dual Rank 12 X 10 TB 7.2K RPM NLSAS 12Gbps 512e 3.5in Hot-plug Hard Drives 4 X 10 TB 7.2K RPM NLSAS 12Gbps 512e 3.5in Internal Hard Drives 2 X 3.84TB SSD SAS Read Intensive 12Gb 512e 2.5in Flex Bay Drives Networking Embedded NIC: Intel X550 Dual Port 10Gb Base-T + I350 Dual Port 1Gb Base-T rNDC adapter Network Adapter 1: Intel XXV710 Dual Port 10/25GbE SFP28 PCIe server adapter, Full height Power Additional Features 2 X Hot Plug Power Supplies 1100W Fan fault tolerance; ECC memory; interactive LCD screen; ENERGY STAR® compliant Environment Temperature Continuous Temperature - Storage Relative Humidity Continuous Relative Humidity Storage Altitude Continuous Altitude Storage Specification 10°C to 35°C (50°F to 95°F) with no direct sunlight on the equipment -40°C to 65°C (-40°F to 149°F) with a maximum temperature gradation of 20°C per hour 10% to 80% with 29°C (84.2°F) maximum dew point 5% to 95% RH with 33°C (91°F) maximum dew point, atmosphere must be non-condensing at all times 3048m (10,000ft) 12,000m (39,370ft) 4.3 DMF Recorder Node (DCA-DM-RA3) Specification This section describes the LEDs provided for monitoring environmental and port status on the DMF Recorder Node (DCA-DM-RA3). 47 The DMF Recorder Node (DCA-DM-RA3) is available as an enterprise-class, 2-socket, 2-RU rack-mounted hardware appliance designed to deliver the right combination of performance, redundancy, and value in a high-density chassis. It has 192TB data storage capacity. Figure 4-7: DMF Recorder Node (DCA-DM-RA3) Bezel 1 System identification button / indicator 2 Recorder Node Security Bezel 3 LCD menu buttons 4 LCD panel 5 Power-on indicator / Power button 6 USB ports Figure 4-8: DMF Recorder Node (DCA-DM-RA3) Front Panel 1 Information tag 2 Video connector 3 Micro USB (not supported) 4 Hard drives 48 Figure 4-9: DMF Recorder Node (DCA-DM-RA3) Rear Panel DMF Recorder Nodes 4.3.1 1 Ethernet connector 1 Not Supported 9 Ethernet connector 4 Recorder Node management port 2, Backup (10/100/1000 Mb/s) 2 Ethernet connector 2 10/25-GbE SFP28 10 Ethernet connector 3 Recorder Node Recorder Interface management port 1, Active (10/100/1000 Mb/s) 3 SSD drives 11 USB ports 4 Power Supply 1 12 Video connector 5 Power Supply 2 13 Serial connector (Default Baud Rate 115200) 6 PSU status indicators 14 iDRAC Ethernet interface 7 Ethernet connector 6 Not supported 8 Ethernet connector 5 Not supported 15 System identification button 16 System identification indicator LEDs and Indicators The following table lists the meaning of each LED or other indicator. 49 4.3.2 Indicator, Button, or Connector Description Power-on indicator Green: System power is on Off: System power is off System identification indicator Off: Normal operating conditions in front panel Blue blinking: System identification has been activated System identification indicator Blue: Normal operation condition in rear panel Blue blinking: System identification has been activated Amber blinking: Fault detected with error code followed by descriptive text in LCD panel 10/100/1000 Mbps Ethernet connector 3, 4 Link indicator Green: A valid 1000 Mb/s network link is established Amber: A valid 10/100 Mb/s network link is established Off: Link is down Activity indicator Green blinking: Network data is being sent or received Off: No link activity 10G/25G SFP28 Ethernet connector 2 Link indicator Green: A valid 25G network link is established Amber: A valid 10G network link is established Green blinking: Recorder port indicator - no transceiver detected or link is down Activity indicator Green blinking: Network data is being sent or received Off: No link activity Power Supply status Green: A valid power source is connected to the power supply and the power supply is operational. Amber blinking: Indicates a problem with the power supply Off: Power is off Platform Management Tool DMF Recorder Node (DCA-DM-RA3) supports iDRAC 9 platform management tools. · iDRAC 9 supported feature: Remote power management, virtual console. 50 4.3.3 DMF Recorder Nodes Technical Specification Recorder Node Processor Form Factor (H X W X D) Memory Hard Drive DCA-DM-RA3 2 x Intel Xeon Gold 6248 2.5GHz, 20 Cores, 40 Threads, 10.4GT/s, 27.5M Cache, Turbo, HT, 150W, DDR4-2933 2-RU Rack Server (8.68cm x 43.4cm x 71.6cm) 16 X 16 GB RDIMM, 2933 MT/s, Dual Rank 12 X 12 TB 7.2K RPM NLSAS 12Gbps 512e 3.5in Hot-plug Hard Drives 4 X 12 TB 7.2K RPM NLSAS 12Gbps 512e 3.5in Internal Hard Drives 2 X 7.68TB SSD SAS Read Intensive 12Gb 512e 2.5in Flex Bay Drives Networking Embedded NIC: Intel X550 Dual Port 10Gb Base-T + I350 Dual Port 1Gb Base-T rNDC adapter Network Adapter 1: Intel XXV710 Dual Port 10/25GbE SFP28 PCIe server adapter, Full height Power Additional Features 2 X Hot Plug Power Supplies 1100W Fan fault tolerance; ECC memory; interactive LCD screen; ENERGY STAR® compliant Environment Temperature Continuous Temperature - Storage Relative Humidity Continuous Relative Humidity Storage Altitude Continuous Altitude Storage Specification 10°C to 35°C (50°F to 95°F) with no direct sunlight on the equipment -40°C to 65°C (-40°F to 149°F) with a maximum temperature gradation of 20°C per hour 10% to 80% with 29°C (84.2°F) maximum dew point 5% to 95% RH with 33°C (91°F) maximum dew point, atmosphere must be non-condensing at all times 3048m (10,000ft) 12,000m (39,370ft) 51 Chapter 5 Arista Supported Hardware This chapter describes the hardware available from Arista that is supported for use with the current release of DANZ Monitoring Fabric. 5.1 5.1.1 Arista 7050CX3-32S Specifications This section describes the LEDs provided for monitoring environmental and switch port status on the Arista 7050CX3-32S switch. Switch LEDs for Monitoring Port and Environmental Status Figure 5-1: Port and Environmental LEDs (Front Panel) 52 Arista Supported Hardware 1 Port 33 1/10-GbE 2 Management Port 3 System Status/Locator LED 4 Fan Status LED 5 Power Supply 1 Status LED 6 Power Supply 2 Status LED 7 USB Port 8 Console Port (Default Baud Rate 9600) 9 Port X:4 Breakout 10/25-GbE Link/Activity LED 10 Port X:3 Breakout 10/25-GbE Link/Activity LED 11 Port X:2 Breakout 10/25-GbE Link/Activity LED 12 40/100-GbE or Port X:1 Breakout 10/25GbE Link/Activity LED 13 Port 34 1/10-GbE (Not supported) Figure 5-2: Port and Environmental LEDs (Rear Panel) 1 PS1 Module 2 Fan1 Module 3 Fan2 Module 4 Fan3 Module 5 Fan4 Module 6 PS2 Module 7 PS2 Status LED 8 Fan4 Status LED 9 Fan3 Status LED 10 Fan2 Status LED 11 Fan1 Status LED 12 PS1 Status LED 53 5.1.2 Port and Environmental LEDs LED System Status PSU[1:2] Status Fan Status Status LED on Power Supply Status LED on Fan Tray Description Green: Normal operation Green blinking: System is powering up Amber: Two or more fans (any combination of fan modules or PSU fans) are disconnected or malfunctioning or incompatible Blue/Blinking Blue: The locater function is active Green: Normal operation Red: One of the power supplies has failed or missing Off: No power Green: Fan Modules powered and running at the expected rpm Amber blinking: One of more Fan tray failed Green: Input power present - Normal operation Amber: Input power present - Power Supply fault Off: No Input power Supply installed in chassis Green: The fan is operating normally. Red: The fan has failed Off: The fan module is not detected. If it is inserted, it may not be seated properly 54 Arista Supported Hardware Port 1-GbE SFP 10-GbE SFP+ LED Link Status 40-GbE QSFP+ 100-GbE QSFP28 Link Status 4X10G QSFP+ breakout 4X25G QSFP28 breakout Management Port Link Status Link /Activity Speed Description Green: Link is up, a valid 1/10-GbE network link is established. Amber: Link is in disabled state Off: Link is down Green: Link is up, a valid 40/100-GbE network link is established Amber Link is in disabled state Off: Link is down Green: Link is up, a valid 10/25-GbE network link is established Amber: Link is in disabled state Off: Link is down Green: A valid network link is established Green blinking: Network Activity in progress Off: Link is down Green: A valid 10/100/1000-Mb/s network link is established Off: Link is down Note: Use the show switch <switch-name> interface all properties command from the controller CLI to display the breakout capabilities of the specified switch. For a list of breakout capable ports on each supported switch, refer to the DANZ Monitoring Fabric Hardware Compatibility List. 5.2 5.2.1 Arista 7050SX3-48YC8 Specifications This section describes the LEDs provided for monitoring environmental and switch port status on the Arista 7050SX3-48YC8 switch. Switch LEDs for Monitoring Port and Environmental Status Figure 5-3: Port and Environmental LEDs (Front Panel) 55 1 System Status/Locator LED 6 Port X:3 Breakout 10/25-GbE Link/Activity LED 2 Fan Status LED 7 Port X:2 Breakout 10/25-GbE Link/Activity LED 3 Power Supply 1 Status LED 8 40/100-GbE or Port X:1 Breakout 10/25GbE Link/Activity LED 4 Power Supply 2 Status LED 9 1/10/25-GbE Link LED 5 Port X:4 Breakout 10/25-GbE Link/Activity LED Figure 5-4: Port and Environmental LEDs (Rear Panel) 1 PS1 Status LED 2 Management Port 3 Fan1 Module 4 Fan2 Module 5 PS2 Status LED 6 PS2 Module 7 Fan2 Status LED 8 Fan1 Status LED 9 USB Port 10 Console Port (Default Baud Rate 9600) 11 PS1 Module 56 5.2.2 Arista Supported Hardware Port and Environmental LEDs LED System Status PSU[1:2] Status Fan Status Status LED on Power Supply Status LED on Fan Tray Description Green: Normal operation Green blinking: System is powering up Amber: Two or more fans (any combination of fan modules or PSU fans) are disconnected or malfunctioning or incompatible Blue/Blinking Blue: The locater function is active Green: Normal operation Red: One of the power supplies has failed or missing Off: No power Green: Fan Modules powered and running at the expected rpm Amber blinking: One of more Fan tray failed Green: Input power present - Normal operation Amber: Input power present - Power Supply fault Off: No Input power Supply installed in chassis Green: The fan is operating normally. This LED state is exclusive to its fan module, and independent of the states of its neighboring fans and power supplies Red: The fan has failed Off: The fan module is not detected. If it is inserted, it may not be seated properly 57 Port 1-GbE SFP 10-GbE SFP+ 25-GbE SFP28 40-GbE QSFP+ 100-GbE QSFP28 LED Link Status Link Status 4X10G QSFP+ breakout 4X25G QSFP28 breakout Management Port Link Status Link /Activity Speed Description Green: Link is up, a valid 1/10/25-GbE network link is established. Amber: Link is in disabled state Off: Link is down Green: Link is up, a valid 40/100-GbE network link is established Amber Link is in disabled state Off: Link is down Green: Link is up, a valid 10/25-GbE network link is established Amber: Link is in disabled state Off: Link is down Green: A valid network link is established Green blinking: Network Activity in progress Off: Link is down Green: A valid 10/100/1000-Mb/s network link is established Off: Link is down Note: Use the show switch <switch-name> interfaces command from the controller CLI to display the breakout capabilities of the specified switch. For a list of breakout capable ports on each supported switch, refer to the DANZ Monitoring Fabric Hardware Compatibility List. 5.3 5.3.1 Arista 7050SX3-48YC12 Specifications This section describes the LEDs provided for monitoring environmental and switch port status on the Arista 7050SX3-48YC12 switch. Switch LEDs for Monitoring Port and Environmental Status Figure 5-5: Port and Environmental LEDs (Front Panel) 58 Arista Supported Hardware 1 1/10/25-GbE Link LED 6 System Status/Locator LED 2 40/100-GbE or Port X:1 Breakout 10/25GbE Link/Activity LED 7 Fan Status LED 3 Port X:2 Breakout 10/25-GbE Link/Activity 8 Power Supply 1 Status LED LED 4 Port X:3 Breakout 10/25-GbE Link/Activity 9 Power Supply 2 Status LED LED 5 Port X:4 Breakout 10/25-GbE Link/Activity LED Figure 5-6: Port and Environmental LEDs (Rear Panel) 1 PS1 Status LED 2 Management Port 3 Fan1 Module 4 Fan2 Module 5 Fan3 Module 6 Fan4 Module 7 PS2 Status LED 8 PS2 Module 9 Fan4 Status LED 10 Fan3 Status LED 11 Fan2 Status LED 12 Fan1 Status LED 13 USB Port 14 Console Port (Default Baud Rate 9600) 15 PS1 Module 59 5.3.2 Port and Environmental LEDs LED System Status PSU[1:2] Status Fan Status Status LED on Power Supply Status LED on Fan Tray Description Green: Normal operation Green blinking: System is powering up Amber: Two or more fans (any combination of fan modules or PSU fans) are disconnected or malfunctioning or incompatible Blue/Blinking Blue: The locater function is active Green: Normal operation Red: One of the power supplies has failed or missing Off: No power Green: Fan Modules powered and running at the expected rpm Amber blinking: One of more Fan tray failed Green: Input power present - Normal operation Amber: Input power present - Power Supply fault Off: No Input power Supply installed in chassis Green: The fan is operating normally. This LED state is exclusive to its fan module, and independent of the states of its neighboring fans and power supplies Red: The fan has failed Off: The fan module is not detected. If it is inserted, it may not be seated properly 60 Arista Supported Hardware Port 1-GbE SFP 10-GbE SFP+ 25-GbE SFP28 40-GbE QSFP+ 100-GbE QSFP28 LED Link Status Link Status 4X10G QSFP+ breakout 4X25G QSFP28 breakout Management Port Link Status Link /Activity Speed Description Green: Link is up, a valid 1/10/25-GbE network link is established. Amber: Link is in disabled state Off: Link is down Green: Link is up, a valid 40/100-GbE network link is established Amber Link is in disabled state Off: Link is down Green: Link is up, a valid 10/25-GbE network link is established Amber: Link is in disabled state Off: Link is down Green: A valid network link is established Green blinking: Network Activity in progress Off: Link is down Green: A valid 10/100/1000-Mb/s network link is established Off: Link is down Note: Use the show switch <switch-name> interfaces command from the controller CLI to display the breakout capabilities of the specified switch. For a list of breakout capable ports on each supported switch, refer to the DANZ Monitoring Fabric Hardware Compatibility List. 5.4 5.4.1 Arista 7050SX3-96YC8 Specifications This section describes the LEDs provided for monitoring environmental and switch port status on the Arista 7050SX3-96YC8 switch. Switch LEDs for Monitoring Port and Environmental Status Figure 5-7: Port and Environmental LEDs (Front Panel) 61 1 1/10/25-GbE Link LED 6 System Status/Locator LED 2 40/100-GbE or Port X:1 Breakout 10/25GbE Link/Activity LED 7 Fan Status LED 3 Port X:2 Breakout 10/25-GbE Link/Activity 8 Power Supply 1 Status LED LED 4 Port X:3 Breakout 10/25-GbE Link/Activity 9 Power Supply 2 Status LED LED 5 Port X:4 Breakout 10/25-GbE Link/Activity LED Figure 5-8: Port and Environmental LEDs (Rear Panel) 1 Fan1 Module 2 Fan2 Module 3 Fan3 Module 4 Fan4 Module 5 Power Supply Module 1 6 Power Supply Module 2 62 5.4.2 Arista Supported Hardware Port and Environmental LEDs LED System Status PSU[1:2] Status Fan Status Status LED on Power Supply Status LED on Fan Tray Description Green: Normal operation Green blinking: System is powering up Amber: Two or more fans (any combination of fan modules or PSU fans) are disconnected or malfunctioning or incompatible Blue/Blinking Blue: The locater function is active Green: Normal operation Red: One of the power supplies has failed or missing Off: No power Green: Fan Modules powered and running at the expected rpm Amber blinking: One of more Fan tray failed Green: Input power present - Normal operation Amber: Input power present - Power Supply fault Off: No Input power Supply installed in chassis Green: The fan is operating normally. This LED state is exclusive to its fan module, and independent of the states of its neighboring fans and power supplies Red: The fan has failed Off: The fan module is not detected. If it is inserted, it may not be seated properly 63 Port 1-GbE SFP 10-GbE SFP+ 25-GbE SFP28 40-GbE QSFP+ 100-GbE QSFP28 LED Link Status Link Status 4X10G QSFP+ breakout 4X25G QSFP28 breakout Management Port Link Status Link /Activity Speed Description Green: Link is up, a valid 1/10/25-GbE network link is established. Amber: Link is in disabled state Off: Link is down Green: Link is up, a valid 40/100-GbE network link is established Amber Link is in disabled state Off: Link is down Green: Link is up, a valid 10/25-GbE network link is established Amber: Link is in disabled state Off: Link is down Green: A valid network link is established Green blinking: Network Activity in progress Off: Link is down Green: A valid 10/100/1000-Mb/s network link is established Off: Link is down Note: Use the show switch <switch-name> interfaces command from the controller CLI to display the breakout capabilities of the specified switch. For a list of breakout capable ports on each supported switch, refer to the DANZ Monitoring Fabric Hardware Compatibility List. 5.5 5.5.1 Arista 7260CX3-64 Specifications This section describes the LEDs provided for monitoring environmental and switch port status on the Arista 7260CX3-64 switch. Switch LEDs for Monitoring Port and Environmental Status Figure 5-9: Port and Environmental LEDs (Front Panel) 64 Arista Supported Hardware 1 40/100-GbE or Port X:1 Breakout 10/25GbE Link/Activity LED 8 Fan Status LED 2 Port X:2 Breakout 10/25-GbE Link/Activity 9 Power Supply 1 Status LED LED 3 Port X:3 Breakout 10/25-GbE Link/Activity 10 Power Supply 2 Status LED LED 4 Port X:4 Breakout 10/25-GbE Link/Activity 11 Management Port LED 5 Port 65 1/10-GbE 12 USB Port 6 Port 66 1/10-GbE 13 Console Port (Default Baud Rate 9600) 7 System Status/Locator LED Figure 5-10: Port and Environmental LEDs (Rear Panel) 1 PS1 Status LED 2 PS1 Module 3 PS2 Status LED 4 PS2 Module 5 Fan4 Module 6 Fan4 Status LED 7 Fan3 Module 8 Fan3 Status LED 9 Fan2 Module 10 Fan2 Status LED 11 Fan1 Module 12 Fan1 Status LED 65 5.5.2 Port and Environmental LEDs LED System Status PSU[1:2] Status Fan Status Status LED on Power Supply Status LED on Fan Tray Description Green: Normal operation Green blinking: System is powering up Amber: Two or more fans (any combination of fan modules or PSU fans) are disconnected or malfunctioning or incompatible Blue/Blinking Blue: The locater function is active Green: Normal operation Red: One of the power supplies has failed or missing Off: No power Green: Fan Modules powered and running at the expected rpm Amber blinking: One of more Fan tray failed Green: Input power present - Normal operation Amber: Input power present - Power Supply fault Off: No Input power Supply installed in chassis Green: The fan is operating normally. This LED state is exclusive to its fan module, and independent of the states of its neighboring fans and power supplies Red: The fan has failed Off: The fan module is not detected. If it is inserted, it may not be seated properly 66 Arista Supported Hardware Port 1-GBase-T 10GBase-T LED Link Status 40-GbE QSFP+ 100-GbE QSFP28 Link Status 4X10G QSFP+ breakout 4X25G QSFP28 breakout Link Status Management Port Link /Activity Speed Description Green: Link is up, a valid 1/10G network link is established. Amber: Link is in disabled state Off: Link is down Green: Link is up, a valid 40/100-GbE network link is established Amber Link is in disabled state Off: Link is down Green: Link is up, a valid 10/25-GbE network link is established Amber: Link is in disabled state Off: Link is down Green: A valid network link is established Green blinking: Network Activity in progress Off: Link is down Green: A valid 10/100/1000Mb/s network link is established Off: Link is down Note: Use the show switch <switch-name> interfaces command from the controller CLI to display the breakout capabilities of the specified switch. For a list of breakout capable ports on each supported switch, refer to the DANZ Monitoring Fabric Hardware Compatibility List. 5.6 Arista 7260CX3-64E Specifications This section describes the LEDs provided for monitoring environmental and switch port status on the Arista 7260CX3-64E switch. 67 5.6.1 Switch LEDs for Monitoring Port and Environmental Status Figure 5-11: Port and Environmental LEDs (Front Panel) 1 40/100-GbE or Port X:1 Breakout 10/25GbE Link/Activity LED 8 Fan Status LED 2 Port X:2 Breakout 10/25-GbE Link/Activity 9 Power Supply 1 Status LED LED 3 Port X:3 Breakout 10/25-GbE Link/Activity 10 Power Supply 2 Status LED LED 4 Port X:4 Breakout 10/25-GbE Link/Activity 11 Management Port LED 5 Port 65 1/10-GbE 12 USB Port 6 Port 66 1/10-GbE 13 Console Port (Default Baud Rate 9600) 7 System Status/Locator LED 68 Figure 5-12: Port and Environmental LEDs (Rear Panel) Arista Supported Hardware 5.6.2 1 PS2 Module 2 PS2 Status LED 3 PS1 Module 4 PS1 Status LED 5 Fan4 Module 6 Fan4 Status LED 7 Fan3 Module 8 Fan3 Status LED 9 Fan2 Module 10 Fan2 Status LED 11 Fan1 Module 12 Fan1 Status LED Port and Environmental LEDs LED System Status PSU[1:2] Status Fan Status Status LED on Power Supply Status LED on Fan Tray Description Green: Normal operation Green blinking: System is powering up Amber: Two or more fans (any combination of fan modules or PSU fans) are disconnected or malfunctioning or incompatible Blue/Blinking Blue: The locater function is active Green: Normal operation Red: One of the power supplies has failed or missing Off: No power Green: Fan Modules powered and running at the expected rpm Amber blinking: One of more Fan tray failed Green: Input power present - Normal operation Amber: Input power present - Power Supply fault Off: No Input power Supply installed in chassis Green: The fan is operating normally. This LED state is exclusive to its fan module, and independent of the states of its neighboring fans and power supplies Red: The fan has failed Off: The fan module is not detected. If it is inserted, it may not be seated properly 69 Port 1-GBase-T 10GBase-T LED Link Status 40-GbE QSFP+ 100-GbE QSFP28 Link Status 4X10G QSFP+ breakout 4X25G QSFP28 breakout Management Port Link Status Link /Activity Speed Description Green: Link is up, a valid 1/10G network link is established. Amber: Link is in disabled state Off: Link is down Green: Link is up, a valid 40/100-GbE network link is established Amber Link is in disabled state Off: Link is down Green: Link is up, a valid 10/25-GbE network link is established Amber: Link is in disabled state Off: Link is down Green: A valid network link is established Green blinking: Network Activity in progress Off: Link is down Green: A valid 10/100/1000-Mb/s network link is established Off: Link is down Note: Use the show switch <switch-name> interfaces command from the controller CLI to display the breakout capabilities of the specified switch. For a list of breakout capable ports on each supported switch, refer to the DANZ Monitoring Fabric Hardware Compatibility List. 5.7 Arista 7280-Series Specifications Given that the 7280 series switch runs EOS, for description of LEDs provided for monitoring environmental and switch port status on the switch, refer to the Quick Start Guide and other related info for the 7280 series of switches as below: https://www.arista.com/en/qsg-7280-series-1ru-gen3 https://www.arista.com/en/products/7280r3-series https://www.arista.com/en/products/7280r-series https://www.arista.com/en/products/7280r-series-network-switch-datasheet 70 References Chapter 6 6.1 Related Documents The following documentation is available for DANZ Monitoring Fabric 8.4.0: · DANZ Monitoring Fabric Release Notes · DANZ Monitoring Fabric User Guide · DANZ Monitoring Fabric Deployment Guide · DANZ Monitoring Fabric Hardware Compatibility List · DANZ Monitoring Fabric Hardware Guide · DANZ Monitoring Fabric Verified Scale Guide · DANZ Monitoring Fabric SNMP MIB Reference Guide 71