Tewaycell Roller Type Mobile ESS Battery

Tewaycell

START GREEN ENERGY WITH

Shenzhen Topway New Energy Co.,Ltd

An image of a recreational vehicle (RV) at dusk, with interior lights on, suggesting off-grid power or energy independence.

CORPORATE BROCHURE

Shenzhen Topway New Energy is a focus on new energy battery research and development, production and sales as one of the high-tech enterprises.

Company Profile

Shenzhen Topway New Energy Co., Ltd was founded in 2013, specializing in manufacturing and design of lithium battery packs for Green Energy Storage Systems. Services include customized battery products, design, development, cell selection, BMS, charger, and after-sale service.

Main products: OEM&ODM 12V/24V/36V/48V LiFePO4 Battery Packs, Wall-mounted ESS, All-in-one Mobile ESS, Mobile ESS, Stack'd ESS, Inverters, Photovoltaic solar panels, Transformers, and solar street light controllers. Applications include home energy storage, RV energy, UPS, Tower Base Stations, and solar energy storage systems.

Products exported to over 100 countries. Overseas warehouses in Germany, Poland, and the United States. Offers grade A battery quality, fast delivery, and stable DDP transportation.

Roller Type Mobile ESS Battery

Model Numbers: TW-MB51300-200A-HWB, TW-MB51200-200A-HWB, TW-MB48300-100A-HWB, TW-MB51300-100A-HWB, TW-MB51200-100A-HWB, TW-MB48200-100A-HWB.

Key Features:

  • Lithium iron phosphate cell technology: high safety, 80% DOD charge/discharge, >6000 cycles.
  • Integrated analog front end, isolated power circuit.
  • Integrated serial port IC: high voltage accuracy (≤20mV), high current accuracy (≤2%@FS).
  • 4-channel battery temperature detection (≤2°C), SOC/SOH estimation.
  • Short-circuit protection, adjustable overcurrent protection, multiple sleep/wake modes, low power consumption.
  • Dual RS485 communication: parameter adjustable settings, buzzer alarm, LED status, charge balance.
  • Temperature range: -20°C to 60°C.
  • Supports parallel connection (up to 15 groups); serial connection not recommended.

Applications:

  • Standby power supply
  • Household energy storage
  • Solar and wind energy systems

Product Dimensions:

ModelSize (L*W*H)
TW-MB51300-200A-HWB880*520*300mm
TW-MB51300-100A-HWB830*450*300mm
TW-MB48300-100A-HWB
TW-MB51200-200A-HWB880*520*300mm
TW-MB51200-100A-HWB
TW-MB48200-100A-HWB830*450*300mm

Diagram Description: Visual representation of the battery unit showing its length (L), width (W), and height (H), with wheels at the base.

Product Details:

Diagram Description: Illustration of battery unit components: Display, Positive Pole, Negative Pole, Air Switch, Balance Switch (Optional), Battery Switch, Communication Area. Shows 100A Type and 200A Type.

Electrical Schematic Diagram:

Diagram Description: Block diagram of the BMS internal architecture showing cell monitoring, power regulation, communication interfaces (SPI, UART, RS232, RS485, CAN), temperature sensors, LED indicators, and control circuits.

Technical Specifications

No.ProjectSpecifications
1ModelTW-MB51300-200A-HWB(16S), TW-MB51200-200A-HWB(16S), TW-MB51300-100A-HWB(16S), TW-MB51200-100A-HWB(16S), TW-MB48300-100A-HWB(15S), TW-MB48200-100A-HWB(15S)
2Nominal capacity300Ah@0.2C200Ah@0.2C300Ah@0.2C / 200Ah@0.2C
3Nominal voltage51.2V(16S)48.0V(15S)51.2V(16S) / 48.0V(15S)
4Charging voltage56.8-57.6V(16S)53.2-54V(15S)56.8-57.6V(16S) / 53.2-54V(15S)
5Operating voltage43.2~44.8V(16S)40.5~42.0V(15S)43.2~44.8V(16S) / 40.5~42.0V(15S)
6Charging current60A40A60A / 40A
7Standard charging modeAt 25°C: charge to 58.4V with 0.2C5A constant current, then constant voltage until current < 0.02C5A (16S). At 25°C: charge to 54.75V with 0.2C5A constant current, then constant voltage until current < 0.02C5A (15S).
8Maximum charging current200A100A200A / 100A
9Maximum discharge current200A100A200A / 100A
10Charging temperature0°C to 45°C (32°F to 113°F) @60±25% RH
11Discharge temperature-20°C to 60°C (-4°F to 140°F) @60±25% RH
12Storage temperature-20°C to 60°C (-4°F to 140°F) @60±25% RH
13Line joint250A Self-Locking Fitting Quick Release Connector120A Self-Locking Fitting Quick Release Connector
15Communication protocolRS485, RS232, CAN
16Support inverter brandGrowatt, Deye, Goodwe, Voltronic power, Sofar, VICTRON, Solis, Megarevo, SRNE

BMS Characteristics

4.1 Instructions for LED lights

BMS features four green capacity indicators, a red alarm indicator, a green running indicator, and a switch indicator.

4.1.1 SOC Capacity Indicator

Table 2 SOC Indicator Status Table:

ConditionChargeDischarge
L1L2L3L4L1L2L3L4
0~25% power (%)Flash 2OFFOFFOFFONOFFOFFOFF
25~50%ONFlash 2OFFOFFONONOFFOFF
50~75%ONONFlash 2OFFONONONOFF
75~100%ONONONFlash 2ONONONON

Running indicator light: ON (charge), Flash 3 (discharge).

4.1.2 Status Indicator

Table 3 Status Indicator Status Table:

StatusON/OFF RunAlertLED Battery Level IndicatorExplain
Shut downSleep modeONOFFOFFOFFOFFOFFLight off
StandbynormalONOFFFlash 1According to electricity indicationstandby mode
warningONFlash 1Flash 3
ChargenormalONONOFFAccording to power indicator (max LED flashes 2)Module low voltage. Max power LED flashes (flash 2), ALM does not flash during overshoot. If no mains, indicator turns to standby.
warningONONFlash 3

Table 4 LED Flashing Description:

Flashing modeONOFF
Flash 10.25s3.75s
Flash 20.5s0.5s
Flash 30.5s1.5s

4.2 Boot and Sleep Mode

Sleep Mode Conditions: Battery/pack over-discharge protection active (30s), Power ON/OFF button press (3s release), battery voltage below sleep setting, standby >24h without charge/discharge, manual sleep via software.

Wake-up Conditions: Charger plugged in (>48V), Power ON/OFF button press (3s release), communication cable plugged in and software opened (if not under over-discharge).

Note: If over-discharge protection is enabled, battery enters sleep mode. Attempts to wake up every 4 hours for charging. If failed 10 times, auto wake-up stops.

Communication Area

BMS communicates via RS232, RS485, CAN for monitoring battery data. Default baud rate 9600bps. RS485 supports address settings 1-15.

Interface Types: RTS, ADS (dial switch), DCT (Dry contact), RS485, CAN, RS232. Rst is reset button.

Diagram Description: Visuals of interface ports (RS232, RS485, CAN) and connection diagrams for CAN/RS485, Dry Contact, Parallel Communication Port, and Communication Interface.

Electrical Interface Definitions

RS232 -- 6P6C Vertical RJ11 Plug

RJ11 pinDefinitionDescription
2NC
3TX(Single board)
4RX(Single board)
5GND

RS485 and CAN Interface

RS485 - 8P8C Vertical RJ45 SocketCAN - 8P8C Vertical RJ45 Socket
RJ45 pinDefinitionRJ45 pinDefinition
1, 8RS485-B19, 10, 11, 14, 16NC
2, 7RS485-A112CANL
3, 6GND13CANH
4, 5NC15GND

Parallel Communication Port

RS485 - 8P8C Vertical RJ45 SocketRS485 - 8P8C Vertical RJ45 Socket
RJ45 pinDefinitionRJ45 pinDefinition
1, 8RS485-B9, 16RS485-B
2, 7RS485-A10, 15RS485-A
3, 6GND11, 14GND
4, 5NC12, 13NC

Description of Parallel Connection

5.1 Parallel Connection Diagram

Connect batteries in parallel following the diagram; system supports up to 15 batteries.

Diagram Description: Wiring diagram showing parallel connection of multiple battery units to a central inverter/management system, illustrating power cable connections.

5.2 Communication Line Parallel Diagram

Use RS485 or CAN lines for parallel battery communication with the inverter. Connect via the parallel communication port and set battery addresses using dial switches.

Table 7 The Dial Switch Setting Table:

AddressDial switch position
#1#2#3#4
0OFFOFFOFFOFF
1ONOFFOFFOFF
2OFFONOFFOFF
3ONONOFFOFF
4OFFOFFONOFF
5ONOFFONOFF
6OFFONONOFF
7ONONONOFF
8OFFOFFOFFON
9ONOFFOFFON
10OFFONOFFON
11ONONOFFON
12OFFOFFONON
13ONOFFONON
14OFFONONON
15ONONONON

Diagram Description: Visuals of battery-to-inverter connections using RS485/CAN and dial switch address setting.

Operating Instructions

6.1 Operating Instructions of the Display Screen

6.1.1 Introduction of LCD Display

Button Description: MENU (management system), ENTER (submenu), DOWN (cursor/next page), ESC (previous).

6.1.2 Boot Screen

Displays "Welcome To Use Smart BMS". Shows protection status: OV, LV, OTt, IT, OC, SC. Status shown only if protected.

Navigation: Press "MENU" for main menu. ">" indicates submenu; press "ENTER" to access.

Menu Structure: Analog Info, BMS Status, Para Setting, Sys Setting.

Analog Info: View Pack V, Im, Temperature, Cell Voltage, Cell Capacity. Use "DOWN" to page.

Temperature Details: T1, T2, T3, T4, PCB-T, ENV-T values (e.g., 23.8°C).

Cell Voltage Details: Individual cell voltages (e.g., Cell 01: 3289 mV).

Cell Capacity Details: View SOC (e.g., 0.00%), FCC (e.g., 300.0 AH), Rm, CC.

BMS Status: Check battery status, use "DOWN" to page.

Record: Check alarm info (SCP, O/UTP, OCP, UVP, OVP). Use "DOWN" to page.

Protection Info: Within BMS Status, check UV, UVP, OC, OCP, OT, OTP, OV, OVP, SCP, Failure (Y/N).

Para Setting & Sys Setting: Access gyroscope info and version info respectively.

Optional Functions

7. Active Equilibrium Function

Cell voltage balancing function. Key parameters include working voltage, difference thresholds, accuracy, and current limits.

Test ItemMinTypeMax
Single IC working voltage (Single series)1.8V/4.5V
Balance opening voltage difference on5mV≤
Balance closing voltage difference on
Accuracy of the balance voltage difference
Balanced turn-on voltage (first string voltage)2.90V≥
Balanced turn off voltage (first string voltage)2.50V ≤
Balanced current (large voltage difference and large current)0/6A
Balanced operating voltage range (B0 to B+ voltage)46.4V68.0V
Current consumption when working100uA1000uA
Current consumption when sleeping08.0uA
Working temperature-40~+85 °C

8. Fire Extinguishing Function (Optional)

Equipped with an aerosol fire extinguishing device that detects temperature and automatically extinguishes fire during short circuits or fires.

ItemParameter
Model specificationsQRR0.04G/S-MC-40-F-02-11
Working temperature range30°C ~ +70°C
Relative humidity of working environment<95%RH
Start modeHot start
Spray time<3s
Starting temperature of thermal initiator170±10°C

Product List and Tools

9.1 Product Packing Lists

Verify all items after unpacking. Confirm model, capacity, voltage, and order specifications. Contact distributor for any issues.

PictureDescriptionQty
[Image: Home energy storage battery]Home energy storage battery1 pieces
[Image: Product manual]Product manual1 pieces
[Image: Positive/negative connector plug]Positive/negative each one
[Image: Signal line (Optional) - CAN/RJ45]4-CAN-H, 5-CAN-L
[Image: Signal line (Optional) - RS485/RJ45]1, 8-RS485-B, 2, 7-RS485-A

Instruction Manual

Connection Steps:

  1. Place battery appropriately and connect positive/negative connector.
  2. Connect other end of positive/negative lead to inverter.
  3. Turn on rocker switch and air switch.

Diagram Description: Diagram showing battery-to-inverter connection via RS485/CAN and power cables.

Models: TW-MB51300-200A-HWB UpGraded 48V 300Ah 15KWh LiFePO4 Mobile, TW-MB51300-200A-HWB, UpGraded 48V 300Ah 15KWh LiFePO4 Mobile, 15KWh LiFePO4 Mobile, LiFePO4 Mobile, Mobile

File Info : application/pdf, 23 Pages, 2.64MB

PDF preview unavailable. Download the PDF instead.

TW-7.5KWH-15KWH-V1.1 ?v=1732242509 Adobe Illustrator(R) 24.0

Related Documents

Preview Tewaycell TW-MB Series Lithium Iron Phosphate Battery System User Manual and Corporate Brochure
Comprehensive guide to Tewaycell TW-MB series lithium iron phosphate power wall batteries, covering product specifications, safety, operation, parallel connection, BMS characteristics, and technical details from Shenzhen Topway New Energy Co., Ltd.
Preview Tewaycell AO Series Household All-in-One Energy Storage System User Manual
Comprehensive user manual for Tewaycell's AO series household all-in-one energy storage systems. Learn about installation, operation, safety features, and technical specifications for efficient green energy solutions.
Preview Tewaycell TW-SK-HV Battery System User Manual
Comprehensive user manual for the Tewaycell TW-SK-HV series high voltage battery systems, covering product introduction, safety precautions, installation, operation, maintenance, and technical specifications.
Preview Tewaycell TW-AO-MB51300/MB51400 Inverter User Manual
Comprehensive user manual for Tewaycell's TW-AO-MB51300 and TW-AO-MB51400 inverters, covering installation, operation, maintenance, and technical specifications for green energy storage systems.
Preview Tewaycell 12KW All-in-One Hybrid Solar Inverter | TW-AO-MB Series Specifications
Detailed specifications for the Tewaycell TW-AO-MB series 12KW all-in-one hybrid solar inverters, featuring long life, easy installation, multiple working modes, and APP control. Includes technical data for models MB51300, MB51400, and MB51600.
Preview Tewaycell Vertical Energy Storage System | 5KW AO-MB Series Datasheet
Detailed technical specifications for the Tewaycell Vertical Energy Storage System, including models AO-MB51100-5KW, AO-MB51150-5KW, AO-MB48200-5KW, AO-MB51200-5KW, AO-MB48300-5KW, and AO-MB51300-5KW. Features include long life, easy installation, multiple working modes, flexible charging, and scalability.
Preview Tewaycell TW-MobileESS Series: Mobile Energy Storage System
Explore the Tewaycell TW-MobileESS Series, a versatile mobile energy storage system offering long life, easy installation, and flexible operation. Features include multiple working modes, fast charging, and scalability for residential and commercial applications. View detailed technical specifications and model information.