Oil Heating Technology

VITOROND® 100

The Viessmann VITOROND® 100 represents advanced oil-fired technology, delivering clean, efficient combustion and exceptional durability for your home heating needs.

[? Heat] [☀️ Solar Integration] [? Hot Water] [⚙️ System Control] [? Home Comfort]

Introduction

Oil is a precious and indispensable natural resource. As such, oil heating must be economical, efficient, and environmentally friendly. Modern oil heating technology from Viessmann satisfies these demands to deliver maximum performance and comfort year after year.

A scenic view of a field of red poppies under a clear sky, symbolizing natural resources and environmental friendliness.

Efficient by Design

The Vitorond 100, with its triple-pass heat exchanger, is designed to achieve a high level of efficiency while providing exceptional comfort. Unlike single-pass boilers, the Vitorond 100 guides flue gases through the heat exchanger three times, allowing for the greatest amount of heat extraction to be achieved. This design significantly increases the efficiency of the boiler, resulting in excellent fuel utilization, reduced emissions, and lower heating costs.

A modern, grey and red oil boiler unit labeled 'VITOROND 100' with the Viessmann logo.

Diagram of the Vitorond 100 Boiler Components:

  • 1. Vitotronic control unit (optional): For advanced heating system control.
  • 2. Triple-pass heat exchanger: Maximizes heat extraction.
  • 3. Stainless steel combustion chamber insert: Ensures clean and efficient combustion.
  • 4. Highly-effective 3½" thermal insulation: Minimizes heat loss.
  • 5. Boiler return injector (with Vitotronic control): Optimizes system performance.

Control Your Comfort

For greater heating system control and additional energy savings, choose a Vitotronic system option. The Vitorond 100 boiler control adjusts the boiler water to outdoor temperatures, boosting efficiency while keeping your home comfortable at all times. The Vitotronic control also allows for safe, low-temperature operation by protecting the heat exchanger against condensation and potential damage. This means your boiler uses less fuel, reducing your energy consumption and heating bill.

Convenience All Around

The Vitorond 100 is an ideal choice for an economical retrofit of your heating system. Thanks to its compact, space-saving design, the Vitorond 100 is easy to install even in older buildings with narrow entrances and small mechanical rooms. With the direct vent option (available for models up to VR1-33), the boiler does not require a chimney or combustion air supply opening, offering greater installation flexibility. The full-swing left- or right-hinged combustion chamber door and easy-to-clean flue gas passageways make service and maintenance fast and trouble-free.

Expand Your System

Our extensive product portfolio allows you to take efficiency and energy savings a step further. Reduce your energy costs by integrating hot water production with your heating boiler, and manage the entire system with one of our control solutions. Alternatively, harness solar energy by adding a solar thermal package. With the entire system from one source, you benefit from total system performance and additional energy savings.

Designed for Efficiency: Triple-Pass Heat Exchanger

The triple-pass design extracts the maximum amount of heat, getting the most from your fuel dollar!

Triple-Pass Heat Exchanger Operation:

  • Pass 1: The burner fires into the stainless steel combustion chamber, sending flue gas to the back of the heat exchanger.
  • Pass 2: The flue gases pass again through the heat exchanger towards the front of the boiler.
  • Pass 3: Finally, flue gases pass through the heat exchanger to the vent at the back of the boiler.
Diagram illustrating the three passes of flue gas through the heat exchanger, showing the burner, combustion chamber, and boiler water flow.
A detailed view of the internal structure of the triple-pass heat exchanger.

Specifications

For further technical data, refer to the Technical Data section.

Benefits at a Glance

Company Information

Viessmann Manufacturing Company Inc.
Waterloo, ON Canada
1-800-387-7373
www.viessmann.ca

Viessmann Manufacturing Company (U.S.) Inc.
Warwick, RI U.S.A.
1-800-288-0667
www.viessmann.us

Technical Data

Vitorond 100, VR1 oil-fired cast iron boiler

Specification Model / MBH Rating
22,91 MBH 27,105 MBH 33,140 MBH 40,161 MBH 50,196 MBH 63,245 MBH
Rated input 91 105 140 161 196 245
Rated output 80 92 122 140 172 215
Efficiency (% A.F.U.E.) 87 87 87 87 87.1 87.1
Dimensions (inches)
  Length (with burner) 38.5 44 44 36 37.5 42.5
  Width 19.75 19.75 19.75 22.25 22.25 22.25
  Height 33 33 33 39.75 39.75 39.75
  Height (with control) 44 44 44 50.5 50.5 50.5
Weight
  Boiler 363 445 447 492 608 725 lbs
  (Block with insulation jacket, burner, and control) 165 202 203 223 276 329 kg

Technical information subject to change without notice. 5794 820-03 12/2017 Printed in Canada

Certifications

The Vitorond 100 is certified by:

Models: Vitorond 100 Oil-Fired Boiler, Vitorond 100, Oil-Fired Boiler, Boiler

File Info : application/pdf, 4 Pages, 255.23KB

PDF preview unavailable. Download the PDF instead.

vitorond 100 flyer

References

Acrobat Distiller 9.0.0 (Windows)

Related Documents

Preview Viessmann Vitomax LW (Type M60A) Boiler: Low-Temperature Oil/Gas Heating Solution
Explore the Viessmann Vitomax LW (Type M60A), a robust low-temperature oil/gas boiler designed for process heating, biogas plants, and mobile hire applications. Delivering proven Viessmann quality from 700 to 1950 kW, it offers exceptional efficiency, low emissions, and advanced control features.
Preview Viessmann Vitorond 200 VD2/VD2A Series Operating Instructions and User's Information Manual
Comprehensive operating instructions and user information for the Viessmann Vitorond 200 VD2/VD2A Series oil/gas-fired boiler. This manual covers essential safety guidelines, installation considerations, operational procedures, and maintenance schedules, specifically tailored for heating contractors.
Preview Viessmann Vitodens 100-W & 111-W Gas Condensing Boilers: Efficient Home Heating
Discover the Viessmann Vitodens 100-W and 111-W wall-mounted gas condensing boilers. Featuring advanced MatriX Plus burner technology, Inox-Radial heat exchangers, and smart connectivity via the ViCare app for efficient, reliable, and cost-effective home heating.
Preview Viessmann Vitocrossal 300 CU3A Series Gas Condensing Boiler Technical Data
Comprehensive technical data, specifications, features, and installation guidelines for the Viessmann Vitocrossal 300 CU3A series gas condensing boilers, including performance, efficiency, and system integration details.
Preview Viessmann Vitodens 300 Gas Fired Condensing Boiler Datasheet and Installation Guide
Comprehensive datasheet and installation information for the Viessmann Vitodens 300 series gas-fired condensing boilers, covering specifications, benefits, installation procedures, and accessories.
Preview Viessmann Vitocrossal 200 CM2 Series Gas Condensing Boiler: Technical Data & Specifications
Detailed technical specifications, features, benefits, dimensions, and system design considerations for the Viessmann Vitocrossal 200 CM2 series gas-fired condensing boilers (models 186, 246, 311).
Preview Viessmann Vitodens 100-W Boiler: Operating Instructions and Safety Guide
Comprehensive operating instructions and safety guidelines for the Viessmann Vitodens 100-W B1HA/B1KA gas-fired condensing boiler. Learn about installation, operation, maintenance, and troubleshooting.
Preview Viessmann Vitodens 200-W Gas Condensing Boiler: Features, Specs, and Benefits
Explore the Viessmann Vitodens 200-W gas condensing boiler. Learn about its advanced features like Lambda Pro, Inox-Radial heat exchanger, Vitotronic 200 control, high efficiency, and multi-boiler capabilities. View technical specifications and benefits for optimal heating performance.