Intesis BACnet MS/TP to BACnet/IP Router
Item number: INBACRTR0320000
Overview
The Intesis BACnet MS/TP to BACnet/IP Router is a compact BACnet multi-network device designed to provide smooth routing between BACnet/IP and BACnet MS/TP networks. This integration solution makes BACnet devices, their objects, and resources accessible regardless of the BACnet network they are connected to.
Image Description: A small, grey rectangular device with network ports and indicator lights, mounted on a DIN rail. It has the Intesis logo and 'BTL' certification mark.
Features and Benefits
- Support for both BACnet/IP and BACnet MS/TP: The gateway supports both BACnet/IP and BACnet MS/TP protocols.
- Commissioning-friendly approach with Intesis MAPS: Templates can be imported and reused as often as needed, significantly reducing commissioning time.
- Configuration through IP (Console) port: Configuration can be carried out through the gateway's IP (Console) port.
- Support for BBMD network role: The gateway offers support for the BBMD (BACnet Broadcast Management Devices) network role.
- BACnet devices scan option with BACnet Explorer: It is possible to scan the BACnet network to discover devices using the BACnet Explorer feature.
- Configuration tool and gateway automatic updates: Both the Intesis MAPS configuration tool and the gateway's firmware can receive automatic updates.
- Support for up to 32 full-load MS/TP devices: The maximum number of BACnet MS/TP devices supported by the gateway is 32.
- BACnet network diagnostic signals available: BACnet network diagnostic signals can be found both in MAPS and as BACnet objects.
General Specifications
Specification | Value |
---|---|
Net Width (mm) | 53 |
Net Height (mm) | 93 |
Net Depth (mm) | 58 |
Net Weight (g) | 92 |
Packed Width (mm) | 120 |
Packed Height (mm) | 80 |
Packed Depth (mm) | 100 |
Packed Weight (g) | 295 |
Operating Temperature °C Min | 0 |
Operating Temperature °C Max | 60 |
Storage Temperature °C Min | -30 |
Storage Temperature °C Max | 60 |
Power Consumption (W) | 1.3 |
Input Voltage (V) | 24 VDC, Max.: 220 mA, 5.2 W |
Power Connector | 3-pole |
Configuration | Intesis MAPS |
Capacity | Up to 32 devices. |
Installation Conditions | This gateway is designed to be mounted inside an enclosure. If the unit is mounted outside an enclosure, precautions should always be taken to prevent electrostatic discharge to the unit. When working inside an enclosure (e.g., making adjustments, setting switches, etc.), typical anti-static precautions should always be followed before touching the unit. |
Content of Delivery | Intesis Gateway, Installation Manual. |
Additional Information
Information | Details |
---|---|
Not Included (in delivery) | Power supply not included. |
Mounting | DIN rail mount (bracket included), Wall mount |
Housing Materials | Plastic |
Warranty (years) | 3 years |
Packaging Material | Cardboard |
Product ID | INBACRTR0320000 |
Country of Origin | Spain |
HS Code | 8517620000 |
Export Control Classification Number (ECCN) | EAR99 |
Connectors / Input / Output | Power supply, EIA-485, Ethernet. |
LED Indicators | Gateway and communication status. |
DIP & Rotary Switches | EIA-485 serial port configuration. |
ETIM Classification | EC001604 |
WEEE Category | IT and telecommunications equipment |
Use Case Example
Image Description: A diagram illustrating the integration of BACnet MS/TP devices with a BACnet/IP network. On the left, three BACnet MS/TP devices are connected to the Intesis BACnet MS/TP to BACnet/IP Router. The router is then connected via BACnet/IP to a Building Management System (BMS) which includes SCADA, HMI, and Controllers.
Related Documents
![]() |
Intesis INBACRTR0320000 BACnet MS/TP to BACnet IP Router Installation Guide Installation guide for the Intesis INBACRTR0320000, a BACnet MS/TP to BACnet IP router, covering safety instructions, mounting, connections, and technical specifications. |
![]() |
Intesis BACnet Server – EtherNet/IP Gateway User Manual User manual for the Intesis BACnet Server – EtherNet/IP gateway (INBACEIP1K20000) by HMS Networks. This guide details connecting BACnet MS/TP and BACnet IP systems with EtherNet/IP networks for industrial automation data integration. |
![]() |
Carrier Ductless to BACnet MS/TP Gateway - INBACMID001I100 Connect Carrier Ductless Indoor Units to BACnet control systems with the Intesis BACnet MS/TP gateway (INBACMID001I100). Features direct connection, DIP-switch setup, and full monitoring capabilities. |
![]() |
Intesis IN485UNI001I100 Universal Gateway: BACnet MS/TP & Modbus RTU User Manual User manual for the Intesis IN485UNI001I100 Universal Gateway, enabling IR air conditioners to integrate with BACnet MS/TP and Modbus RTU building management systems. Covers installation, hardware, and protocol specifications. |
![]() |
Intesis INBACPAN1280000 Panasonic VRF to BACnet IP Server Gateway Installation Guide Comprehensive installation guide for the Intesis INBACPAN1280000 gateway, designed to integrate Panasonic VRF systems with BACnet IP networks. Covers safety warnings, installation procedures for wall and DIN rail mounting, connection details, and technical specifications. |
![]() |
Intesis Panasonic Etherea AC to BACnet MS/TP Interface Datasheet Datasheet for the Intesis IN485PAN001I000 interface, enabling seamless bidirectional communication between Panasonic Etherea air conditioner units and BACnet MS/TP networks. This gateway provides fixed BACnet objects for AC unit data, supports remote control, features easy DIP switch configuration, offers energy-saving occupancy functions, is compatible with nanoe™X air purification, and requires no external power supply. |
![]() |
Intesis KNX TP to Modbus TCP & RTU Server Application Gateway Intesis KNX TP to Modbus TCP & RTU Server Application gateway enables seamless integration between KNX devices and Modbus BMS or controllers, supporting up to 3000 KNX objects and multiple Modbus clients. |
![]() |
Intesis INBACDAL***0200 DALI to BACnet Server Gateway Datasheet Technical datasheet for the Intesis INBACDAL***0200 Gateway, a DALI to BACnet IP & MSTP server gateway for lighting control and building automation. Details features, connections, protocols, and specifications. |