User Guide for SAVANT models including: PS20-BATT-20KWH LFP Battery System, PS20-BATT-20KWH, LFP Battery System, Battery System, System
File Info : application/pdf, 5 Pages, 5.66MB
DocumentDocumentSavant Power Storage 20 [100A] Quick Reference Guide Box Contents (1) Savant Power Inverter (PS-INV-12.5KW-100A-XX) (8) Power Storage 20 Battery (PS20-BATT-20KWH) (1) Savant Power Director (1) Battery Crate (8 x Modules) (1) Conduit Nipple Kit (1) Mounting & Installation Kit (4) M5x12 Screws (4) M5x10 Screws (4) M10 Expansion Screws (4) M6 Expansion Anchor Screw Specifications Inverter Front Panel Right Panel Left Panel C H A B D I F J E G K L MN O P R Environmental Temperature Inverter: -13°F to 131°F (-25°C to 55°C) Battery: 32°F to 113°F (0°C to 45°C) NC1 COM2 NC2 COM GPS USB4 NO1 COM2 NO2 LH TR RS232 DC 12V DC 12V PS G C-LED GBA UPCS DC 12V RS232 RS232 BCMS NETWORK USB2 USB3 SD RESET 4G LTE C-LED RS485-4 UPCS RS485-1 DC V12 GRID L1 N L2 LOAD L1 N L2 GEN L1 N L2 Humidity 0% to 95% Relative Humidity (non condensing) Descriptions Q Altitude Less than 9842 ft Rating NEMA4X Dimensions and Weights Height Length 85.4 in (216.92 cm) 25.6 inch (65.02 cm) Inverter Power Depth 12.2 inch (30.988 cm) Maximum Grid Transfer Maximum Output Current Time Surge Output Weight 600 lbs (272.15 kg) Maximum Passthrough Per Inverter A Inverter Status LEDs B Inverter Front Panel C ON/OFF Button D Grid Switch E Conduit Knock-outs F Antennas See Inverter Status LEDs. Remove panel to reveal inverter wiring area. Power on or off the Savant Power Storage. Connect or disconnect the Grid input. Knockouts for AC Conductor Conduits. Wi Fi, GPS, 4G Main, and 4G DIV Antennas 12.5 kW < 70ms 35 kVA, 20 ms 21 kVA, 10s Battery Power Battery Capacity 52 Ah / 20 kWh Maximum Power 12.5kW Standards Wi-Fi 2.4 GHz IEEE 802.11 b/g/n 100A G Reset Button Press to reset inverter status. H Parallel Inputs used to parallel multiple inverters. I Reset Button Press to reset inverter. J Battery & Communication Caps Waterproof caps. K Network RJ-45 LAN connection. L PV Inputs MPPT Inputs. Regulatory Safety and Emissions Contains FCC ID: Certifications RoHs FCC Part 15 Class B 2AA9B10 UL 1741 SA, UL 1741 PCS, UL9540, UL 1973, UL 1642, UL 1998, CSA 22.2 Compliant M I/O Ports See Inverter I/O Ports. N Inverter Wiring Pre-installed inverter wiring. O Battery Inputs P GRID, LOAD, & GEN Connections Q Ground R Rear-Entry Conduit Knockouts Battery power inputs. Grid, Load, and Generator connections. Inverter & battery grounding connections. Knockouts for AC Conductor Conduits. Copyright © 2023 Savant Systems, Inc | 090523 009-2383-00 | Savant Power Storage [100A] QRG 1 of 5 45 Perseverance Way, Hyannis MA 02601 www.savant.com | 508.683.2500 Inverter I/O Ports A Inverter Status LEDs B CDE FG H GPS USB4 NO1 COM2 NO2 LH TR RS232 DC 12V DC 12V PS G C-LED GBA UPCS DC 12V RS232 RS232 BCMS NETWORK USB2 USB3 SD RESET 4G LTE C-LED RS485-4 UPCS RS485-1 DC V12 AB C D NETWORK STATUS GRID GENERATOR LOAD RUN NC1 COM2 NC2 COM I Front Input/Outputs A Status LED Table B Network See the Status LED table RJ45 connection for wired internet connection C USB Ports Used for local software updating. D SD Enables local data collection without internet connection. E Reset Reset button to reset inverter status. F CLED G GPIO Ports H BCMS I RS-485Port Power input for LEDs. See section 3.7 of the Savant Power Storage 20 Installation Guide. Battery Monitor System Communication Port See section 3.9.2 of the Savant Power Storage 20 Installation Guide. Status LEDs & Inverter States A Network B Status C Power D Run Solid Red: Energy management unit startup in progress. Blinking Red: Ready for network connection. Blinking Green: Wi-Fi network and password detected, or Ethernet cable detected, connecting to router. Solid White: Connecting to the Internet. Solid Green: Internet connected successfully. Blinking Blue: System updating. Blinking Red: Communication fault between energy management unit and battery system, inverter unit, or PV unit. Solid Red: Energy management unit internal communication fault. Blinking Green: System is turned off by energy management unit. Solid Green: System running normally. On: Grid, Generator, or Load power is operating normally. Off: No power input Blinking: Grid, Generator, or Load power is operating outside nominal parameters. Solid Green: Inverter/PV charging unit running normally Solid Red: Inverter unit fault. Solid Yellow: PV charging unit fault, or system into over-temperature protection. Blinking Yellow: Inverter/PV charging unit alarming. Blinking Green: Inverter unit/PV charging unit updating. Copyright © 2023 Savant Systems, Inc | 090523 009-2383-00 | Savant Power Storage [100A] QRG 2 of 5 45 Perseverance Way, Hyannis MA 02601 www.savant.com | 508.683.2500 Battery Status Panel A DC 12V CAN Battery Access Panel B C A D B E C RESET STATUS F D POWER START E G H I Battery Status Panel I/O & Status LEDs A 12V & GND Battery enclosure power & ground connections. B REF Battery reference connection. C BAT- Battery negative connection. D BAT+ Battery positive connection. E Ground Ground connection to Power Storage 20 F CAN G Fuse Box CANBUS Port to communicate with the Savant inverter. Overcurrent protection for battery modules. H System SoC Total system State of Charge in 25% increments. Blinking Yellow: Battery System is starting up or an update in progress. Blinking Blue: Battery System is in Self- Battery Inspecting mode. I System Status Solid Green: Running normally. Indicator Solid Yellow: An alarm has been raised. Solid Red: A fault has been detected. Battery Status Panel I/O & Status LEDs A Power Switch Toggle ON or OFF all batteries. B Reset Button Press to restart battery system. C Status LED Blinking Yellow: Startup or upgrade in progress Blinking Blue: Self-inspecting Solid Green: Running normally Solid Yellow: Alarming Solid Red: Protection/Fault D Start Button Press to start battery system. Blinking Yellow: Startup or upgrade in progress Blinking Blue: Battery Module is in Self- E Battery Status LED Inspecting mode. Solid Green: Running normally. Solid Yellow: An alarm has been raised. Solid Red: A fault has been detected. Copyright © 2023 Savant Systems, Inc | 090523 009-2383-00 | Savant Power Storage [100A] QRG 3 of 5 45 Perseverance Way, Hyannis MA 02601 www.savant.com | 508.683.2500 Bracket Installation 1. Open the battery enclosure with a PH2 Philips screwdriver and remove the accessories kit. 2. Assemble the bracket as shown using M5x12 screws. 16in 406mm 2 1 12in 305mm Inverter Installation 6. Remove the battery seal cap marked BAT/COM on the bottom left of the Savant Power Inverter. 7. Remove the Battery Status panel side communication cable panel. 2 1 3. Attach the bracket to the back side of the battery system with M5x12 machine screws. Tighten to 3 N·m (26.55 lb-in) torque. 4. Drill a 0.47 in (12mm) hole with a 2.76 in (70mm) depth into the floor. Embed the anchor expansion bolts and affix the cabinet to the ground. 8. Hang the inverter on the bracket. 9. Fasten the Savant Power Inverter and the bracket with M5x12 machine screws. (Torque: 3 N·m). 10. Fasten Savant Power Inverter and the battery cabinet with conduit and screw kit, as shown. 3 3 4 5 11. Gently plug in each battery module from the bottom up. Fasten the modules on both sides using M4x8 screws (Torque: 1.2 N·m). 6 5. Install the bracket on the wall with M6x50 tapping screws. IMPORTANT NOTES: When installing it on a concrete wall, properly drill into the wall with M6x50 expansion anchor screws. If Savant Power Inverter is installed separately from battery system, install the bracket on a surface capable of supporting its weight using M6x50 tapping screw. Then hang Savant Power inverter on the bracket, and fasten it with M4x16 screws. NOTE: Mark number 1~8 on labels of each battery module before installation and plug them into the cabinet in reverse numerical order. Always keep batteries ordered as they are first installed. 1 2 3 4 5 6 7 8 Copyright © 2023 Savant Systems, Inc | 090523 009-2383-00 | Savant Power Storage [100A] QRG 4 of 5 45 Perseverance Way, Hyannis MA 02601 www.savant.com | 508.683.2500 Wiring 1. Connect battery system to the Savant Power Inverter with ground wire. 5. Make all connections between the inverter and the electrical system. Generator, and Load connections. For more information, see the Savant Power Storage 20 Deployment Guide. GBA UPCS DC 12V RS232 BCMS REF BAT- BAT+ REF DC- DC+ L1 N L2 L1 N L2 L1 N L2 RS485-1 DC 12V CONNECTIONS TO LOAD 6. (Optional) Connect Savant Power Storage 20 to photovoltaic array. RS232 DC 12V CONNECTION CONNECTION PV1+ PV1- PV2+ PV2- 1 CONNECTIONS TO PHOTO VOLTAIC TR G RS232 DC 12V DC 12V GBA UPCS ARRAY L HG CAN PS G C-LED DC 12V GPS USB4 RESET NETWORK USB2 USB3 SD SIM C-LED RS232 2. Make the REF, BAT-, BAT+ connections from the inverter through the conduit to the corresponding connections on the battery access panel through the conduit. 3. Connect the DC 12V wire between the inverter and the battery battery access panel. 4. Connect the BCMS port of the Savant Power Inverter to the CANBUS connection of the Battery Status Panel. 7. Connect Savant Power Storage 20 to the same network switch as the Power Director or the network port of the Power Director itself using a CAT5 or higher Ethernet cable. RS232 DC 12V CONNECTION CONNECTION PV1+ PV1- PV2+ PV2- TR G RS232 DC 12V DC 12V GBA UPCS REF BAT- BAT+ REF DC- DC+ L1 N L HG CAN GPS USB4 RESET NETWORK USB2 USB3 SD SIM PS G C-LED C-LED DC 12V RS232 BCMS RS485-1 DC 12V Network Switch Power Director GPIO 2 PoE MAIN NETWORK 5VDC 3 4 More Information To continue deployment and configure the Savant Power Storage 20, see the following documentation. Savant Power Storage Savant Power Storage 20 DC 12V App Setup Guide Installation Guide CAN Copyright © 2023 Savant Systems, Inc | 090523 009-2383-00 | Savant Power Storage [100A] QRG 5 of 5 45 Perseverance Way, Hyannis MA 02601 www.savant.com | 508.683.2500