SECOP Compressor Technical Data
Model: KLF6.6CNT
Designation: 200-240V/50Hz 1~, 208-230V/60Hz 1~
Sales Code: 106H2712
Compressor Design
Parameter | Value |
---|---|
Oil type | Polyolester |
Oil viscosity | 19,2cSt |
Oil quantity | 170cm³ / 5,7fl.oz |
Refrigerant charge - tech. limit | 200g / 7,1oz |
Free gas volume comp. | 1583cm³ / 53,5fl.oz |
Weight | 9,5kg / 20,9lbs |
Motor protection | external |
Winding resistance main | 8,4Ω (at 25°C) |
Winding resistance aux | 11,9Ω (at 25°C) |
Max. winding temp. | 125°C / 257°F |
Max. discharge temp. | 130°C / 266°F |
A visual representation of a SECOP KL-Series compressor is shown.
General Configurations
Configurations for KLF6.6CNT:
Parameter | Conf. 1 | Conf. 2 |
---|---|---|
Motor configuration | CSIR | CSIR |
Power supply (nominal) | 200-240V/50Hz | 208-230V/60Hz |
Number of phases | 1 | 1 |
Voltage range | 187-254V | 198-253V |
Approvals | UL, KC, CB | UL, KC, CB |
Starting torque | HST | HST |
Note | Electrical equipment is included and pre-assembled to compressor. |
Applications
Applications for KLF6.6CNT:
Parameter | Conf. 1 | Conf. 2 |
---|---|---|
Refrigerant | R290 | R290 |
Application | LBP+MBP | LBP+MBP |
System cooling | fan 3m/s | fan 3m/s |
Hot gas defrost | OK | OK |
Long interval pull down | OK | OK |
Electrical Data
Electrical data for KLF6.6CNT configurations:
Parameter | Conf. 1 | Conf. 2 |
---|---|---|
Starting device type | relay | relay |
Run capacitor | -/- | -/- |
Start capacitor | 80μF | 80μF |
LRA (locked rotor amps / 4s/ U(N)) | 13,5A | 12,9A |
RLA (rated load amps / 1s/ U(N)) | 1,8A | 1,7A |
Cut in current (U(N)) | 12,3A |
Compressor Dimensions
Housing Dimensions
- A Height: 182mm / 7,17in
- B Height: 175mm / 6,89in
- C Length shell: 198mm / 7,8in
- D Length w. cover: 238mm / 9,37in
- E Width: 160mm / 6,3in
Diagram shows compressor housing dimensions labeled A (Height), B (Height), C (Length shell), D (Length w. cover), and E (Width).
Connectors
Parameter | Configuration | ||
---|---|---|---|
Suction (X) | Discharge (Y) | Process (Z) | |
Diameter [mm] (i:inside, o:outside) | Øi 8,11-8,29 | Øi 6,11-6,29 | Øi 6,11-6,29 |
Diameter [in] (i:inside, o:outside) | Øi 0,32-0,33 | Øi 0,24-0,25 | Øi 0,24-0,25 |
Material | copper | copper | copper |
Horizontal angle | ±2° | 35° | 0° |
Vertical angle | ±2° | 30° | 145° |
Position l/h/w [mm] | 119/73/59 | 117/107/66 | -88/101/71 |
Position l/h/w [in] | 4,7/2,9/2,3 | 4,6/4,2/2,6 | -3,5/4/2,8 |
Straight tube l. [mm] | 14 | 14 | 14 |
Straight tube l. [in] | 0,5 | 0,5 | 0,5 |
A diagram illustrates the compressor's external features and connector ports labeled X, Y, Z, A, B, C, D, E, h, l, and w. It indicates horizontal and vertical angles for connectors.
Compressor Fixation
Measurement | [mm] | [inch] |
---|---|---|
Bl | 204 | 8.03 |
Bw | 132 | 5.2 |
ØE | Ø 9.7 | Ø 0.38 |
Measurement | [mm] | [inch] |
---|---|---|
Ll | 165 | 6.5 |
Lw | 101.6 | 4 |
ØL | Ø 19 | Ø 0.75 |
Measurement | [mm] | [inch] |
---|---|---|
Sl | 170 | 6.7 |
Sw | 70 | 2.76 |
ØS | Ø 16 | Ø 0.63 |
Diagrams illustrate compressor fixation methods. One shows a baseplate with dimensions Bl, Bw, E, Ll, Lw, ØL, ØE, Sl, Sw, and hole types (Baseplate, Large holes, Small holes). Another diagram depicts a "Bolt joint" assembly with components like Washer, Nut, Sleeve, Compressor base, Bolt, and Rubber grommet. A third diagram shows a "Snap-on" assembly with a Washer, Clip, Steel pin, Compressor base, and Rubber grommet.
Mounting Accessories
Accessory Type | Part Number (Single) | Part Number (Multi-pack) |
---|---|---|
Bolt joint | M6 | Ø16mm | 118-1917 | 118-1918 |
Bolt joint | Ø1/4" | Ø16mm | 118-1946 | 118-1919 |
Bolt joint | Ø1/4" | Ø19mm | 118-1949 | |
Snap-on | Ø7,3 | Ø16mm | 118-1947 |
Application Notes
Provision for PE Grounding is located at the PE Stamp on the compressor.
Configuration Details
Configuration 1 (200-240V/50Hz)
Motor configuration | CSIR |
Power supply (nominal) | 200-240V/50Hz 1~ |
Refrigerant | R290 |
Application | LBP+MBP |
Voltage range | 187-254V |
Starting torque | HST |
Approvals | UL, KC, CB |
Configuration 2 (208-230V/60Hz)
Motor configuration | CSIR |
Power supply (nominal) | 208-230V/60Hz 1~ |
Refrigerant | R290 |
Application | LBP+MBP |
Voltage range | 198-253V |
Starting torque | HST |
Approvals | UL, KC, CB |
Operating Conditions and Performance
Ambient and Machine Room Temperatures
Ambient temperature range: 10 - 43°C / 50 - 110°F
Machine room temperature range: 10 - 48°C / 50 - 119°F
Compressor cooling: fan 3m/s
Operation Pressure Range
Two graphs illustrate the operation pressure range.
The upper graph shows Condensing Pressure (sat. temp.) in [bara] on the Y-axis against Evaporation Pressure (sat. temp.) in [bara] on the X-axis. It displays two curves: one for "continuous operation" and one for "transitory operation". Temperature scales in °C and °F are provided below the X-axis.
The lower graph plots Condensing Pressure [bara] on the Y-axis against Evaporation Pressure [bara] on the X-axis, also showing curves for "continuous operation" and "transitory operation".
Electrical Accessories / Wiring Diagram
Diagrams show electrical accessories and a wiring schematic.
Components include:
- a5: current relay (T0377/L6-S1) - Part Number: 117U7071
- c: start capacitor (80μF, 6.3mm) - Part Number: 117U5003
- b, d: cover + clamp + screws (5VA-compl.) - Part Number: 103N0600
- b, d: 100x cover + clamp + screws (5VA) - Part Number: 103N2060
- b, d: cover + clamp + screws (5VA) in bag - Part Number: 103N1060
Optimization and Standard Conditions
Data for R290, 220V/50Hz, CSIR, fan 3m/s, UL, KC, CB (Conf. 1)
Conditions | Evaporating Pressure (saturation temperature) | Condensing Pressure (saturation temperature) | Return gas temp. | Liquid temp. | Cooling capacity | COP | EER | Power consumption | Current consumption | Ref. mass flow [kg/h] | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
pe [°C] | pe [°F] | pc [°C] | pc [°F] | RGT [°C] | Tliq [°C] | [W] | [Btu/h] | [kcal/h] | [W/W] | [Btu/Wh] | [kcal/Wh] | [W] | [A] | |||||||
ASHRAE LBP | -23 | -10 | 54 | 130 | 32 | 32 | 333,5 | 1139 | 287,0 | 1,47 | 5,01 | 1,26 | 227,4 | 1,60 | 3,38 | |||||
cecomaf LBP | -25 | -13 | 55 | 131 | 32 | 55 | 249,5 | 852 | 214,7 | 1,14 | 3,88 | 0,98 | 219,4 | 1,58 | 3,11 | |||||
EN12900 LBP | -35 | -31 | 40 | 104 | 20 | 40 | 178,5 | 610 | 153,6 | 1,20 | 4,08 | 1,03 | 149,4 | 1,42 | 2,04 | |||||
ASHRAE MBP | -7 | 20 | 54 | 130 | 35 | 46 | 585,1 | 1998 | 503,6 | 1,93 | 6,59 | 1,66 | 303,1 | 1,85 | 6,67 | |||||
cecomaf MBP | -10 | 14 | 55 | 131 | 32 | 55 | 467,8 | 1598 | 402,6 | 1,60 | 5,47 | 1,38 | 291,9 | 1,81 | 5,92 | |||||
EN12900 MBP | -10 | 14 | 45 | 113 | 20 | 45 | 516,0 | 1762 | 444,1 | 2,00 | 6,84 | 1,72 | 257,6 | 1,69 | 6,34 |
Data for R290, 220V/60Hz, CSIR, fan 3m/s, UL, KC, CB (Conf. 2)
Conditions | Evaporating Pressure (saturation temperature) | Condensing Pressure (saturation temperature) | Return gas temp. | Liquid temp. | Cooling capacity | COP | EER | Power consumption | Current consumption | Ref. mass flow [kg/h] | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
pe [°C] | pe [°F] | pc [°C] | pc [°F] | RGT [°C] | Tliq [°C] | [W] | [Btu/h] | [kcal/h] | [W/W] | [Btu/Wh] | [kcal/Wh] | [W] | [A] | |||||||
ASHRAE LBP | -23 | -10 | 54 | 130 | 32 | 32 | 407,6 | 1392 | 350,7 | 1,56 | 5,32 | 1,34 | 261,8 | 1,71 | 4,13 | |||||
cecomaf LBP | -25 | -13 | 55 | 131 | 32 | 55 | 306,2 | 1046 | 263,5 | 1,22 | 4,16 | 1,05 | 251,6 | 1,68 | 3,81 | |||||
EN12900 LBP | -35 | -31 | 40 | 104 | 20 | 40 | 216,8 | 740 | 186,6 | 1,21 | 4,15 | 1,05 | 178,5 | 1,49 | 2,48 | |||||
ASHRAE MBP | -7 | 20 | 54 | 130 | 35 | 46 | 702,4 | 2399 | 604,5 | 1,99 | 6,79 | 1,71 | 353,1 | 2,01 | 8,01 | |||||
cecomaf MBP | -10 | 14 | 55 | 131 | 32 | 55 | 561,8 | 1919 | 483,5 | 1,66 | 5,67 | 1,43 | 338,3 | 1,96 | 7,11 | |||||
EN12900 MBP | -10 | 14 | 45 | 113 | 20 | 45 | 615,1 | 2101 | 529,4 | 2,01 | 6,86 | 1,73 | 306,3 | 1,85 | 7,55 |
Performance Tables
Performance data for R290, 220V/50Hz, CSIR, fan 3m/s, UL, KC, CB (Conf. 1)
Conditions | Cooling capacity | COP | EER | Power consumption | Current consumption | Ref. mass flow [kg/h] | ||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
[W] | [Btu/h] | [kcal/h] | [W/W] | [Btu/Wh] | [kcal/Wh] | [W] | [A] | |||||
cond. pressure pc= 45/113 return gas temp. RGT= 32/90 liquid temp Tliq= 45/113 |
177,9 295,1 446,0 537,2 640,7 757,8 952,7 |
608 1008 1523 1835 2188 2588 3254 |
153,1 254,0 383,8 462,3 551,4 652,1 819,9 |
1,12 1,45 1,84 2,09 2,37 2,70 3,28 |
3,83 4,95 6,30 7,12 8,08 9,21 11,21 |
0,96 1,25 1,59 1,79 2,04 2,32 2,82 |
158,7 203,8 241,8 257,6 270,7 281,0 290,3 |
1,44 1,53 1,64 1,69 1,73 1,77 1,80 |
1,99 3,33 5,07 6,15 7,38 8,79 11,19 |
|||
cond. pressure pc= 55/131 return gas temp. RGT= 32/90 liquid temp Tliq= 55/131 |
141,7 249,5 385,8 467,8 560,8 666,1 841,7 |
484 852 1318 1598 1915 2275 2875 |
121,9 214,7 332,0 402,6 482,7 573,2 724,4 |
0,86 1,14 1,43 1,60 1,80 2,02 2,40 |
2,95 3,88 4,89 5,47 6,14 6,90 8,21 |
0,74 0,98 1,23 1,38 1,55 1,74 2,07 |
164,0 219,4 269,5 291,9 312,0 329,7 350,3 |
1,43 1,58 1,73 1,81 1,88 1,94 2,02 |
1,75 3,11 4,85 5,92 7,14 8,56 10,97 |
Performance data for R290, 220V/60Hz, CSIR, fan 3m/s, UL, KC, CB (Conf. 2)
Conditions | Cooling capacity | COP | EER | Power consumption | Current consumption | Ref. mass flow [kg/h] | ||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
[W] | [Btu/h] | [kcal/h] | [W/W] | [Btu/Wh] | [kcal/Wh] | [W] | [A] | |||||
cond. pressure pc= 45/113 return gas temp. RGT= 32/90 liquid temp Tliq= 45/113 |
210,0 352,5 531,5 640,4 765,2 908,2 1150,8 |
717 1204 1815 2187 2613 3102 3930 |
180,7 303,4 457,4 551,1 658,5 781,6 990,4 |
1,13 1,46 1,85 2,09 2,37 2,69 3,26 |
3,87 4,98 6,32 7,14 8,09 9,20 11,12 |
0,98 1,26 1,59 1,80 2,04 2,32 2,80 |
185,3 241,6 287,3 306,3 322,9 337,1 353,5 |
1,51 1,65 1,78 1,85 1,90 1,95 2,01 |
2,35 3,98 6,05 7,33 8,81 10,53 13,52 |
|||
cond. pressure pc= 55/131 return gas temp. RGT= 32/90 liquid temp Tliq= 55/131 |
176,9 306,2 465,3 561,8 672,6 799,9 1017,0 |
604 1046 1589 1919 2297 2732 3473 |
152,2 263,5 400,5 483,5 578,8 688,4 875,2 |
0,96 1,22 1,49 1,66 1,85 2,07 2,44 |
3,29 4,16 5,10 5,67 6,32 7,06 8,32 |
0,83 1,05 1,29 1,43 1,59 1,78 2,10 |
183,6 251,6 311,3 338,3 363,4 386,7 417,3 |
1,49 1,68 1,87 1,96 2,05 2,13 2,25 |
2,19 3,81 5,85 7,11 8,57 10,27 13,25 |