SECOP SCE21MNIX Compressor: Technical Data

Model Designation: SCE21MNIX

Sales Code: 104H8151

Voltage/Frequency: 220-240V/60Hz 1~

Compressor Design

AttributeValue
Oil typePolyolester
Oil viscosity32cSt
Oil quantity500cm³ / 16.9fl.oz
Refrigerant charge - tech. limit500g / 17.6oz
Free gas volume comp.3150cm³ / 106.5fl.oz
Weight14.9kg / 32.8lbs
Motor protection1# internal
Winding resistance main2.2Ω (at 25°C)
Winding resistance aux5.3Ω (at 25°C)
Max. winding temp.125°C / 257°F
Max. discharge temp.140°C / 284°F

Refrigerant and Displacement

AttributeValue
Refrigerant(s)R290, 0, 0
Displacement21cm³ / 1.28cu.in
Compressors on pallet48

Product Image

A visual representation of the SECOP compressor, typically black, with branding "SECOP SCE Plus". It has a cylindrical body with visible connections.

General Configurations

AttributeValue
Motor configurationCSCR
Power supply (nominal)220-240V/60Hz
Number of phases1
Voltage range195-254V
Approvals(Not specified)
Starting torqueHST
NoteStarter kit (relay), cover and cord relief are included and pre-assembled.

Applications

AttributeValue
RefrigerantR290
ApplicationMBP (Medium Back Pressure)
System coolingfan 3m/s
Hot gas defrostOK
Long interval pull downOK

Electrical Data

AttributeValue
Starting device typerelay
Run capacitor15µF
Start capacitor60µF
LRA (locked rotor amps / 4s/ U(N))31.8A
RLA (rated load amps / 1s/ U(N))4A
Cut in current (U(N))(Not specified)

Compressor Dimensions

Housing Dimensions

DimensionValue (mm)Value (in)
A Height236.49.31
B Height230.69.08
C Length shell2178.54
D Length w. cover263.410.37
E Width161.16.34
F Width with equipment1997.83

A dimensional diagram illustrates the compressor's physical layout, indicating heights, lengths, and widths. Connection points are labeled X (Suction), Y (Discharge), and Z (Process).

Connectors

AttributeConnection Type
Suction (X)Discharge (Y)Process (Z)
Diameter [mm]øi 9.54-9.72øi 6.41-6.59øi 6.41-6.59
Diameter [in]øi 0.38-0.38øi 0.25-0.26øi 0.25-0.26
Materialcoppercoppercopper
Horizontal angle±2°37°37°
Vertical angle±2°36°36°
Position l/h/w [mm]-111/212/57116/127/81110/94/72
Position l/h/w [in]-4.4/8.3/2.24.5/5/3.24.3/3.7/2.8
Straight tube l. [mm]121212
Straight tube l. [in]0.50.50.5

Compressor Fixation

Diagrams detail the compressor's mounting points. This includes baseplate dimensions (e.g., length, width, hole diameters) and specific hole sizes (large and small) for secure attachment. It also shows details of bolt joints and snap-on mounting mechanisms, illustrating how the compressor is secured to a base using bolts, washers, nuts, rubber grommets, clips, and steel pins.

Mounting Accessories

Accessory TypePart Number (Single)Part Number (Multi-pack)
Bolt joint | M6 | ø16mm118-1917118-1918
Bolt joint | ø1/4" | ø16mm118-1946
Bolt joint | ø1/4" | ø19mm118-1949
Snap-on | ø7.3 | ø16mm118-1947118-1919

Application Notes

Provision for PE Grounding is located at the PE Stamp on the compressor.

Configuration Summary

AttributeValue
Motor configurationCSCR
Power supply (nominal)220-240V/60Hz 1~
RefrigerantR290
ApplicationMBP
Voltage range195-254V
Starting torqueHST
Approvals(Not specified)

Ambient and Machine Room Temperatures

Ambient temperature range: 10 - 43°C / 50 - 110°F

Machine room temperature range: 10 - 48°C / 50 - 119°F

Compressor cooling: fan 3m/s

Operation Pressure Range

A graph illustrates the compressor's operation pressure range, plotting condensing pressure (bara) against evaporation pressure (bara). It shows distinct lines for continuous and transitory operation, indicating the safe operating envelope based on saturation temperatures.

Electrical Accessories and Wiring Diagram

A schematic diagram shows the electrical connections for the compressor, including components like the starter kit, terminal board, start capacitor, run capacitor, retaining clamp, screws, and cord relief. The diagram details how these components are wired together for operation.

Components

ComponentPart Number
a5 SC starter kit117U8102
b cover terminal board + clamp117U1036
c start capacitor (60µF)117U5351
e run capacitor (15µF, 6.3mm)117-7167
e1 retaining clamp117-0313
screw M4x8mm117-0301
d cord relief103N1007

Optimization + Standard Conditions Performance

This section provides performance data under various standard conditions, including evaporating and condensing pressures, return gas temperature, and liquid temperature. It details cooling capacity, COP (Coefficient of Performance), EER (Energy Efficiency Ratio), power consumption (P1), current consumption (I), and reference mass flow (m).

ConditionsEvaporating pressure (saturation temperature)Condensing pressure (saturation temperature)Return gas temp. RGT [°C/°F]Liquid temp. Tliq [°C/°F]Cooling capacityCOPEERPower consumptionCurrent [A]Ref. mass flow [kg/h]
pe [°C]pe [°F]pc [°C]pc [°F][W][Btu/h][kcal/h][W/W][Btu/Wh][kcal/Wh][W]
ASHRAE MBP-72035952070.670721782.054462.067.031.771005.75.3923.62
cecomaf MBP-101432901640.356021411.755551.735.901.49949.15.1620.75
EN12900 MBP-1014451131900.764911635.845452.177.421.87875.34.8623.34
ARI540 MBP-720491201990.567981713.118492.087.111.79955.65.1825.85
opt-101432901978.767581702.9451132.267.721.95875.34.8622.64
opt-25-1332901017.63475875.7451131.565.321.34653.14.0711.48

Performance Tables

Detailed performance data is presented in tables, categorized by condensing pressure (pc) and evaporation pressure (pe) at specific return gas temperatures (RGT) and liquid temperatures (Tliq). These tables provide precise values for cooling capacity, COP, EER, power consumption, current, and mass flow rate.

Table 1: pc = 45/113°F

pe [°C/°F]Cooling capacityCOPEERPower consumptionCurrent [A]Ref. mass flow [kg/h]
[W][Btu/h][kcal/h][W/W][Btu/Wh][kcal/Wh][W]
-25 / -131017.63475875.71.565.321.34653.14.0711.48
-20 / -41307.244641125.01.796.101.54731.94.3314.80
-15 / 51626.555551399.82.026.891.74806.64.6018.51
-10 / 141978.767581702.92.267.721.95875.34.8622.64
0 / 322794.295432404.72.839.672.44986.55.3132.41
5 / 413263.7111462808.83.1810.882.741024.95.4738.18
10 / 503778.5129043251.83.6012.303.101049.25.5744.65

Table 2: pc = 55/131°F

pe [°C/°F]Cooling capacityCOPEERPower consumptionCurrent [A]Ref. mass flow [kg/h]
[W][Btu/h][kcal/h][W/W][Btu/Wh][kcal/Wh][W]
-25 / -13792.02705681.61.214.141.04653.24.069.86
-20 / -41049.53584903.21.394.751.20753.94.4113.13
-15 / 51331.345471145.71.565.331.34853.24.7916.74
-10 / 141640.356021411.71.735.901.49949.15.1620.75
0 / 322352.680342024.72.107.161.801122.85.8830.22
5 / 412762.194332377.12.317.881.991196.66.1935.82
10 / 503211.2109672763.62.558.712.201259.06.4742.10

PDF preview unavailable. Download the PDF instead.

sce21mnix 104h8151 r290 220v 60hz 08-2025 ds Microsoft Excel für Microsoft 365

Related Documents

Preview Secop SC18MLX Compressor Technical Data and Specifications
Comprehensive technical specifications, performance data, dimensions, electrical schematics, and operational limits for the Secop SC18MLX compressor (220-240V, 50Hz, CSCR) used in refrigeration and air conditioning systems.
Preview Secop SCE23MNDX Compressor: Technical Data, Specifications, and Performance
Detailed technical data sheet for the Secop SCE23MNDX compressor, including specifications, performance tables, dimensions, electrical data, and application notes for R290 refrigerant.
Preview SECOP KLF6.6CNT Compressor Technical Data Sheet
Comprehensive technical data for the SECOP KLF6.6CNT compressor, detailing specifications, configurations (CSIR and RSCR), electrical data, operating pressure ranges, and performance tables for R290 refrigerant across various voltage and frequency settings (200-240V/50Hz and 208-230V/60Hz). Includes dimensions, application notes, and accessory information.
Preview Secop SCE25MNDX Compressor Technical Data Sheet | R290 MBP
Comprehensive technical data sheet for the Secop SCE25MNDX compressor. Features include R290 refrigerant, 220-240V/50Hz operation, CSCR motor, and MBP application. Includes dimensions, electrical specs, and performance tables.
Preview SECOP KLF5.6CND Compressor Technical Data Sheet
Explore detailed technical specifications, performance data, and configuration options for the SECOP KLF5.6CND R290 compressor. This document covers electrical characteristics, operating ranges, and application suitability for refrigeration systems.
Preview SECOP SCE23MNIX Compressor Technical Data Sheet
Detailed technical specifications for the SECOP SCE23MNIX compressor, including design, dimensions, electrical data, operating conditions, and performance tables. Suitable for R290 refrigerant and 220-240V/60Hz operation.
Preview Secop MS18UHULTM Compressor Technical Data Sheet
Comprehensive technical data, specifications, and application notes for the Secop MS18UHULTM ULT-ready compressor, designed for low-temperature cascade refrigeration systems.
Preview Secop SC18/18CL Twin-Compressor Technical Data and Specifications
Comprehensive technical data, specifications, dimensions, electrical information, and performance tables for the Secop SC18/18CL Twin-Compressor. Includes wiring diagrams and component details.