Instruction Manual for SENECA models including: R-4RTD-8DIDO Series Mixed I O Module, R-4RTD-8DIDO Series, Mixed I O Module, O Module
1 день назад — For use and settings via DIP-SWITCH, see the user manual available on the website on the web page dedicated to the product. ... The fault-bypass function ...
For use and settings via DIP-SWITCH, see the user manual available on the website on the web page dedicated to the product. The DIP-switch settings are read ...
INSTALLATION MANUAL R-4RTD-8DIDO Series PRELIMINARY WARNINGS The word WARNING preceded by the symbol indicates conditions or actions that put the user's safety at risk. The word ATTENTION preceded by the symbol indicates conditions or actions that might damage the instrument or the connected equipment. The warranty shall become null and void in the event of improper use or tampering with the module or devices supplied by the manufacturer as necessary for its correct operation, and if the instructions contained in this manual are not followed. WARNING: The full content of this manual must be read before any operation. The module must only be used by qualified electricians. Specific documentation is available using the QR-CODE shown on page 1. The module must be repaired and damaged parts replaced by the Manufacturer. The product is sensitive to electrostatic discharges. Take appropriate measures during any operation. Electrical and electronic waste disposal (applicable in the European Union and other countries with recycling). The symbol on the product or its packaging shows the product must be surrendered to a collection centre authorized to recycle electrical and electronic waste. DOCUMENTATION SENECA s.r.l.; Via Austria, 26 35127 PADOVA ITALY; Tel. +39.049.8705359 - Fax +39.049.8706287 CONTACT INFORMATION Technical support supporto@seneca.it Product information commerciale@seneca.it This document is the property of SENECA srl. Copies and reproduction are prohibited unless authorised. The content of this document corresponds to the described products and technologies. Stated data may be modified or supplemented for technical and/or sales purposes. MI00711-1-EN INSTALLATION MANUAL 1/6 MODULE LAYOUT FRONT 106.6 mm SIDE 32.2 mm 108 mm Weight: 170 g; Enclosure: UL94-V0 self-extinguishing PC/ABS material, black. SIGNALS VIA LED ON FRONT PANEL LED IO1/IO8 OUT SUP STS (Status only version R-4RTD-8DIDO) STS (Status only version R-4RTD-8DIDO-P) COM (only version R- 4RTD-8DIDO-P) FAIL RX (only version R- 4RTD-8DIDO) TX (only version R- 4RTD-8DIDO) ETH TRF (Yellow) ETH LNK (Green) STATUS On Off On Off On Flashing On Flashing Off Flashing On On Flashing Flashing Flashing Flashing LED meaning Digital input/output active Digital input/output not active Digital inputs/outputs powered Digital inputs/outputs not powered IP address set Waiting for the IP address from the DHCP IP address set No configured IP address No Profinet communication Profinet communication present Digital output in FAIL RS485 port wiring error Reception of data packet completed on RS485 Transmission of data packet completed on RS485 Packet transit on Ethernet port Ethernet port connected MI00711-1-EN INSTALLATION MANUAL 2/6 TECHNICAL SPECIFICATIONS CERTIFICATIONS INSULATION RTD1 RTD2 RTD3 RTD4 POWER SUPPLY ENVIRONMENTAL CONDITIONS ASSEMBLY CONFIGURATION CONNECTIONS/ COMMUNICATION PORTS DIGITAL INPUTS DIGITAL OUTPUTS RTD INPUTS MEASUREMENT ERROR Voltage: 10 ÷ 40 Vdc; 19 ÷ 28 Vac; 45 ÷ 65 Hz; Absorption: 2 W Operating temperature: from -25°C to 70°C; Humidity: 10% ÷ 90% non condensing. Storage temperature: from -30°C to +85°C Protection rating: IP20 35mm DIN rail IEC EN60715 With built-in WEB server (only version R-4RTD-8DIDO) Removable 3.5 mm pitch terminal block, 1.5 mm2 max cable section 2 Ethernet (with LAN fault-bypass function) 100 base T on RJ45 1 RS485 port on terminals (only version R-4RTD-8DIDO) Number of channels: 8; Voltage: Threshold ON: > 11 Vdc; Threshold OFF:< 4 Vdc; Vmax: 24 Vdc; Impedance: 9 k Compliant with IEC61131-2 type 3. Number of channels: 8, MOSFET, PNP; Max voltage/current: 0.2 A; 12 ÷ 24 Vdc, Protected against short-circuit. Number of channels: 4 with 2, 3 and 4 wires connection. Type and measuring range: - PT100, EN 60751/A2 (ITS-90), -200 ÷ +650°C - PT500, EN 60751/A2 (ITS-90), -200 ÷ +750°C - PT1000, EN 60751/A2 (ITS-90), -200 ÷ +210°C - CU50 GOST 6651-2009, -180 ÷ +200°C - CU100 GOST 6651-2009, -180 ÷ +200°C - NI100, EN 60751/A2 (ITS-90), -60 ÷ +250°C - NI120 DIN 43760, -60 ÷ +250°C - NI1000 DIN 43760, -60 ÷ +250°C Resolution: 24 bit (Adc) Accuracy class: 0.05% on the resistive value Stability (noise): 18 bit ENOB Temperature drift: < 30 ppm/K Sampling time: from 25 to 400 ms Scan time: from 25 to 400 ms for all channels. CMR @50/60 Hz: >100 dB NMR @ 50/60 Hz: >75 dB Sensor detection/interrupted conductors YES, disconnectable Maximum cable resistance: 50 Referred to RTD resistive value: 2-wire measurement 0.05 % + cable resistance 3-wire measurement 0.05 % + 0.005 % + per ohm cable resistance 4-wire measurement 0.05 % MI00711-1-EN INSTALLATION MANUAL 3/6 ELECTRICAL CONNECTIONS CAUTION The upper power supply limits must not be exceeded, as this could cause serious damage to the module. Switch the module off before connecting inputs and outputs. To meet the electromagnetic immunity requirements: - use shielded signal cables; - connect the shield to a preferential instrumentation earth system; - separate shielded cables from other cables used for power installations (transformers, inverters, motors, etc.). POWER SUPPLY RS485 SERIAL PORT + / 20 / 21 22 23 B(-) 24 A(+) 25 GND Connection to the RS485 port. Polarity is not standardised and in some devices may be inverted. RTD INPUTS 4 WIRE CONNECTION A (40, 45, 53, 58) + B (41, 46, 54, 59) C (42, 47, 55, 60) D (43, 48, 56, 61) S (44, 49, 57, 62) 3 WIRE CONNECTION A (40, 45, 53, 58) + B (41, 46, 54, 59) C (42, 47, 55, 60) D (43, 48, 56, 61) S (44, 49, 57, 62) + DIGITAL INPUTS (PNP) With external power V EXT DIGITAL OUTPUTS (PNP) With external power 10 LOAD 10 11 LOAD 11 12 LOAD 12 .... LOAD .... 17 LOAD 17 18+ + V EXT 18+ 19- 19- The digital inputs must be powered The digital outputs must be powered externally to function properly (V EXT). externally to function properly (V EXT). 2 WIRE CONNECTION A (40, 45, 53, 58) + B (41, 46, 54, 59) C (42, 47, 55, 60) D (43, 48, 56, 61) S (44, 49, 57, 62) SETTING THE DIP-SWITCHES WARNING The DIP-switch settings are read only at boot time. At each change, perform a restart. For use and settings via DIP-SWITCH, see the user manual available on the website on the web page dedicated to the product. SW1 DIP-SWITCH: DEFAULT SETTINGS SW1 DIP1 OFF DEFAULT DIP2 OFF SETTINGS DIP-SWITCH SW1 is located on the front of the device. MI00711-1-EN INSTALLATION MANUAL 4/6 DAISY-CHAIN ETHERNET CONNECTION CAUTION IT IS NOT ALLOWED TO CREATE LOOPS WITH ETHERNET CABLES Using the daisy-chain connection it is not necessary to use switches to connect the devices. The following examples show the correct connections. MODULE 1 MODULE 2 MODULE 3 MODULE 1 MODULE 2 MODULE 3 There must be no loops in the Ethernet cabling, otherwise the communication will not work. The modules and switches must be connected eliminating any loops. The following examples show the incorrect connections. LOOP LOOP MODULE 1 MODULE 1 MODULE 2 MODULE 3 The LAN fault-bypass function allows you to keep the connection between the two Ethernet ports of the device ON, in the event of a power failure. If a device turns off, the chain is not interrupted and the devices downstream of the switched-off one will still be accessible. This function has a limited duration: the connection remains active for a few days, typically 4. The fault-bypass function requires that the sum of the lengths of the two cables connected to the switched off module is less than 100m. ETHERNET CONNECTION RULES For the Ethernet cabling between the devices, the use of the unshielded CAT5 or CAT5e cable is required. FACTORY IP ADDRESS (ONLY R-4RTD-8DIDO) The default module IP address is static: 192. 168. 90. 101 WEB SERVER To access the maintenance Web Server, use the following credentials: Default user: admin Default password: admin CAUTION DO NOT USE DEVICES WITH THE SAME IP ADDRESS IN THE SAME ETHERNET NETWORK MI00711-1-EN INSTALLATION MANUAL 5/6Adobe PDF Library 17.0 Adobe InDesign 18.5 (Windows)