Welcome to Comtronics Smart Homes
Thank you for choosing Comtronics for your security needs. We are confident that your new system will provide you with security, peace of mind, and convenience. Comtronics prides itself on offering flexibility and integrity in its products.
Key Features:
- Multi-path and redundant alarm communications: Utilizes both cellular and Wi-Fi connections for a secure pathway to Comtronics' Five Diamond UL Certified Central Station.
- 24/7/365 Monitoring: Your system is monitored by Comtronics, the same company that provided the product, ensuring no third parties or complex call centers.
- Flexibility: The system is designed to accommodate various needs, supporting video cameras, door locks, garage door openers, lamps, thermostats, and more.
- Simple Setup: Designed for easy installation with no wiring or drilling required.
The Comtronics Smart Homes Security System is designed for flexibility, supporting everything from basic security to advanced home automation. It's easy to install and fun to use.
System Components Overview: The system includes a LYNX 5200 CONTROLLER, TRANSFORMER, MOTION SENSOR, DOOR CONTACTS, and a KEY FOB.
Installation Instructions
Follow these steps to install your security system:
Step 1: Unpack Your Control Panel, Desk Mount and Transformer
- Mount the control panel to the desk mount using the pre-aligned notches on the back.
- Place the mounted control panel in a convenient location for your family.
- Plug the transformer into a wall socket to power on the system.
Step 2: Install Door/Window Contacts
Placement: Select transmitter and magnet locations as suggested in the accompanying diagrams.
Alignment: Ensure the transmitter and magnet are within 1/4 inch of each other. The magnet height may need adjustment using the included spacer to align with the transmitter, depending on your door/window frame.
Attachment: Use the included peel-and-stick tape. Clean the surface with an alcohol swab before applying. Press the contact firmly for 15-20 seconds.
Diagram Description: Shows a door/window sensor setup with a transmitter and magnet, illustrating the 1/4 inch alignment and the use of a magnet spacer.
Step 3: Install Motion Sensor
Attachment: Use the included peel-and-stick tape. Clean the surface with an alcohol swab before applying. Press the sensor firmly for 15-20 seconds.
Mounting Location: Mount the sensor at least eight inches down from the ceiling, no closer than seven feet from the floor, with the lens facing down.
Coverage: The motion sensor has a 40° view and can detect movement up to 35 feet away.
Placement Considerations: Do not mount directly near or over a heat source, A/C unit, ceiling fan, or facing a large window.
Diagram Description: Illustrates recommended mounting locations for the motion sensor, showing it mounted in a corner or on a flat wall with the lens facing downwards.
Step 4: Install Additional Purchased Devices
- Refer to the included insert for suggested locations of smoke and/or carbon monoxide detectors, based on National Fire Protection Association guidelines.
- Additional devices or accessories will come with their own mounting and setup instructions.
Step 5: Set Up User Codes and WiFi
Refer to page 4 for User Code setup and page 6 for WiFi setup.
Step 6: Set Up Total Connect
Set up Total Connect on your computer, smartphone, or tablet. Activation typically occurs within 24-48 hours, with an email containing login information sent to you. Refer to page 8 for PC setup and page 9 for mobile setup.
Step 7: Test Your System
Call Comtronics at 800-DIY-4757 (800-349-4757) and select Option #3 to test your system and activate your service.
Setting Up Your User Codes
This section guides you through creating and managing user codes for your Lynx 5200 panel.
To Add a New User:
- From the Home screen, select 'Security'.
- Select 'More'.
- Select 'Tools'.
- Enter the Master Code (default is 1234).
- Select 'Users'.
- Select 'Add New'.
- Enter a User Name (e.g., "User3").
- Select 'Done'.
- Enter a 4-digit User Code.
- Select 'Done'.
- Select 'Save'.
To Edit an Existing User:
- From the Home screen, select 'Security'.
- Select 'More'.
- Select 'Tools'.
- Enter the Master Code (default is 1234).
- Select 'Users'.
- Select the user you wish to edit (e.g., 'Master', 'Guest').
- Select 'Edit'.
- Modify the User Code or other settings as needed.
- Select 'Done' after entering the new code.
- Select 'Save'.
Setting Up WiFi
Connect your Lynx 5200 panel to your home WiFi network.
- From the Home screen, select 'Security'.
- Select 'More'.
- Select 'Tools'.
- Enter the Master Code (default is 1234).
- Select 'WiFi Config'.
- Select 'Scan Access Points'.
- Select your WiFi Network (SSID) from the list and select 'Edit'.
- Select 'Key' (the field will be blank).
- Type in your WiFi Password using the on-screen keyboard.
- Select 'Done'.
- Select 'Join'.
- Select 'OK' to confirm the device has been added to the network.
Setting Up Total Connect on Your PC
Access your security system remotely via the Total Connect website.
Instructions:
- Navigate to www.TotalConnect2.com.
- Ensure you have the necessary plugins installed: QuickTime and Adobe Flash Player. Download links are provided:
- QuickTime: apple.com/quicktime/download/
- Adobe Flash Player: get.adobe.com/flashplayer/
- Enter your Username and Password, then select 'Connect'.
- For Internet Explorer users: You may need to allow add-ons to run. Look for a yellow bar at the top and select 'Run Add-On', then 'Run' in the subsequent popup.
Supported Browsers: Google Chrome (recommended), Internet Explorer, and Mozilla Firefox.
- Google Chrome: google.com/chrome/
- Internet Explorer: windows.microsoft.com/en-us/internet-explorer/download-ie
- Mozilla Firefox: mozilla.org/en-US/firefox/new/
Setting Up Total Connect on Mobile Devices
For Android:
- Navigate to the Play Store.
- Search for "Total Connect 2.0".
- Select "Total Connect 2.0" from the results.
- Click 'Install'.
- Click 'Accept' to agree to the terms and conditions.
- Once downloaded, find and select the "TC 2.0" app.
- Enter your Comtronics username and password. Select 'Remember Me' if desired.
- Select 'Login'.
For iOS (iPhone/iPad):
- Locate and select the App Store icon.
- Search for "Total Connect 2.0".
- Select "Total Connect 2.0" from the results. If on an iPad, you may need to switch to the iPhone app view.
- Click 'FREE' to download the app.
- Click 'Install'. You will be prompted for your Apple ID credentials.
- Once downloaded, find and select the "TC 2.0" app on your home screen.
- Enter your Comtronics username and password. Select 'Remember Me (ON)' if desired.
- Select 'Login'.
Upon successful login, you will see a screen displaying the current status of your alarm system, allowing you to send commands.
Suggestions and Tips
- Mounting: Two-sided tape works well on clean, dry surfaces. Mounting screws are provided for a more permanent attachment.
- System Capabilities: Contact Comtronics if you have questions about advanced features.
- Controller Power: The controller has a battery backup but must remain plugged in. Do not plug into a GFI outlet or a 'switch controlled' outlet.
- Sensor Location: If installing a sensor in a different area, contact Comtronics to rename the device location.
- Sensor Range: Contacts and sensors typically work within 100 feet of the Lynx 5200 panel, though construction types or obstructions may affect this distance.
- Motion Sensors: While pet resistant, false alarms can still occur. Contact Comtronics for assistance with your sensors.
- System Testing: Comtronics recommends monthly system testing. Call 800-DIY-4757 (800-349-4757) to schedule a test.
- Moving Residences: If you move your system to a new residence, notify Comtronics at 800-349-4757. Failure to report the new location may result in fees or loss of police/fire response.
For feedback and system improvement suggestions, visit www.comtronicsDIY.com/survey.
Expand Your Smart System
Enhance your connected living experience with these integrated products:
Indoor/Outdoor IP Cameras
- Enjoy up to 6 cameras on Total Connect.
- Easy to install and configure.
- Compact and portable design.
- Low Light Infrared, outdoor, and pan/tilt models are available.
Honeywell Thermostats
- Adaptive intelligent recovery learns temperature settings.
- Keypad lockouts prevent unauthorized changes.
- Provides reminders to change air filters.
- Offers energy savings of up to 33% on heating and cooling costs.
Lamp Modules
- Control lighting via mobile device, tablet, or computer.
- Side-plug design allows access to lower outlets.
- Features one always-on pass-through AC outlet and one Z-Wave enabled outlet.
- Control multiple lights or individual lights within ambient scenes.
Smoke/Heat Detectors
- Smart Check signals the panel when cleaning is needed.
- Drift Compensation minimizes nuisance alarms from dust.
- Easy-to-install mounting base.
- Utilizes a long-life 3V lithium battery.
Carbon Monoxide Detectors
- Electrochemical sensing for accurate measurement.
- Six-year lifespan with an End of Life Timer.
- Dual LED status indicators (normal, alarm, low battery, trouble).
- Versatile ceiling or wall mounting.
KwikSet Door Locks
- Available in Polished Brass, Satin Nickel, and Venetian Bronze.
- Remotely check status, lock/unlock doors, and receive alerts.
- Features SmartKey® re-key technology with BumpGuard™.
- BHMA Grade 2 certified with a 20-minute fire rating.
Visit www.comtronicsDIY.com or your retailer for ordering information.