Haier Split Type Room Air Conditioner Operation Manual

Model Numbers: AS09PBDHRA, AS12PBDHRA, AS18PDDHRA, AS24PDDHRA, AS30PFDHRA, AS20PBDHRA, AS26PBDHRA, AS35PBDHRA, AS53PDDHRA, AS71PDDHRA, AS90PFDHRA

Important Information

Please read this operation manual carefully before using the air conditioner. Keep this manual for future reference. This appliance is filled with R32 refrigerant.

WARNING: This appliance contains a UV-C lamp. Read the maintenance instructions before opening the appliance. Eye or skin irritation may result from exposure from the top air inlet and inner part. Ensure the power is cut off before performing maintenance. UV-C barriers bearing the ultraviolet radiation hazard symbol should not be removed. Do not operate UV-C lamps outside the appliance. The appliance must be disconnected from the power supply before replacing or cleaning the UV-C lamp. If the UV-C lamp is damaged, it must be replaced by the manufacturer, its service agent, or similarly qualified persons to avoid a hazard. Unintended use or damage to the housing may result in the escape of dangerous UV-C radiation, which can cause harm to eyes and skin.

Parts and Functions

Indoor Unit

Remote Controller

The remote controller has various buttons for operation:

Outdoor Unit

WiFi Setup

If your Air Conditioner has a Connected Appliance Information label, it is WiFi Connect Enabled. This allows remote monitoring and control via a smartphone app. Visit www.haier.com.au/smart or www.haier.co.nz/smart for more information.

Operation

Unit Start/Stop

Press the ON/OFF button on the remote controller to start or stop the unit.

Temperature Setting

Use the TEMP +/- buttons to adjust the desired temperature. Pressing the button once increases/decreases the temperature by 1°C. Holding the button down increases/decreases it more rapidly.

Fan Speed Selection

Press the FAN button to cycle through fan speeds: LOW, MED, HI, AUTO. In AUTO mode, the air conditioner automatically adjusts fan speed based on room temperature.

Air Flow Direction Adjustment

Use the SWING button to adjust the vertical flap. Pressing it repeatedly cycles through different flap positions (Pos.1 to Pos.4). Pressing it again stops the swing function. Use the EXTRA FUNCTION button to select Pos.2 and Pos.3.

Cautions:

Timer On/Off Operation

Press the TIMER button to select TIMER ON, TIMER OFF, or TIMER ON-OFF mode. Use the TEMP +/- buttons to set the desired time (0.5-hour increments up to 12 hours, then 1-hour increments up to 24 hours). Press CONFIRM to set the timer. Press CANCEL to cancel the timer setting.

POWER/SOFT Operation

Use this function for rapid heating or cooling. Access it via the EXTRA FUNCTION button.

QUIET Operation

Press the QUIET button for silent operation. Press again to cancel.

Self Clean Operation

Press the Self Clean button to activate this function, which cleans the evaporator and condenser. The display will show "CL". The function runs for 20-30 minutes and exits automatically. Pressing other mode buttons can exit the function earlier.

Emergency Operation and Test Operation

Emergency Operation: Use when the remote controller is lost or defective. The system automatically selects the operation mode based on room temperature. It is not possible to operate in DRY mode.

Test Operation: Use when room temperature is below 16°C. Press and hold the emergency switch for more than 5 seconds. The unit will start cooling with high fan speed and stop automatically after 30 minutes.

Comfortable SLEEP

Activate via the EXTRA FUNCTION button. In COOL/DRY mode, the temperature rises gradually. In HEAT mode, the temperature decreases gradually then rises. This function cannot be used with the TIMER function.

Power Failure Resume Function

After a power failure, the unit will resume operation automatically after a 3-minute delay to protect the compressor.

Healthy Airflow Operation

Activate via the EXTRA FUNCTION button to adjust the louvers for optimal airflow. Do not direct the flap by hand.

HEALTH Operation

Activates UV sterilization to remove harmful microorganisms. Recommended for 1-2 hours daily. Avoid direct exposure to the UV lamp.

Maintenance

For Smart Use of The Air Conditioner

Remote Controller Maintenance

Wipe the controller with a dry cloth. Do not use glass cleaner or chemical cloths.

Indoor Body Maintenance

Wipe the unit with a soft, dry cloth. For stubborn stains, use a neutral detergent diluted with water. Wring out the cloth before wiping and then wipe off any detergent residue.

Air Filter Cleaning

  1. Open the inlet grille by pulling it upward.
  2. Remove the filter by pushing up the center tab.
  3. Clean the filter using a vacuum cleaner or by washing it with water. Dry the filter completely in the shade.
  4. Attach the filter correctly with the "FRONT" indication facing outwards. Ensure it is securely fixed.
  5. Close the inlet grille.

Note: Air purifying filter is an optional part.

Replacement of Air Purifying Filter

  1. Open the inlet grille.
  2. Detach the standard air filter by sliding the knob upward.
  3. Attach the air purifying filter into the right and left filter frames.
  4. Attach the standard air filter (necessary installation). The white side of the photocatalyst filter faces outwards, and the black side faces the unit. The green side of the bacteria-killing medium filter faces outwards, and the white side faces the unit.
  5. Close the inlet grille.

Notes on Air Purifying Filters:

Cautions

WARNING

CAUTION

Troubleshooting

Normal Performance Inspection

Dry Mode Fan Speed

In DRY mode, fan speed may be fixed at LOW when room temperature is lower than the set temperature +2°C.

Poor Cooling

Check power plug, power failure, blown fuse, dirty air filter, obstacles at inlet/outlet, incorrect temperature setting, open doors/windows, direct sunlight, or excessive heat sources/people in the room.

Multiple Check

Ensure the power plug is inserted, there is no power failure, the fuse is intact, the air filter is clean, there are no obstacles, the temperature is set correctly, doors/windows are closed, and direct sunlight is managed.

Specifications

The machine is adaptive in following situation

1. Applicable ambient temperature range:

Indoor Outdoor
Cooling Max: 32°C DB/23°C WB
Min: 21°C DB/15°C WB
Max: 46°C DB/26°C WB
Min: -10°C DB
Heating Max: 27°C DB
Min: 15°C DB
Max: 24°C DB/18°C WB
Min: -10°C DB

(INVERTER) Outdoor: Max: 24°C DB/18°C WB, Min: -15°C DB

2. Power supply cord replacement: Must be done by manufacturer, service agent, or qualified person.

3. Fuse replacement: Indoor unit fuse: T.3.15A/250V. Outdoor unit fuse: T.25A/250V.

4. Wiring method: Must comply with local wiring standards.

5. Power plug accessibility: Must be easily reached after installation.

6. Waste battery disposal: Dispose of properly.

7. Appliance use by children/infirm persons: Not intended without supervision.

8. Supervision of children: Ensure children do not play with the appliance.

9. Power plug: Use a proper power plug that fits the power supply cord.

10. Power plug and cable: Must have local attestation.

11. Powering off: Turn off A/C first, wait at least 30 seconds before cutting off power.

Customer Support

For Haier Appliances:

Important notice of Disclosure: Copyright © Fisher & Paykel Appliances 2019. All rights reserved. Product dimensions and specifications may change without notice. Contact Haier's Customer Care Centre for current product information.

Fisher & Paykel Australia Pty Ltd, Level 1, 1 Eden Park Drive, Macquarie Park, NSW 2113. Phone: 1300 729 948 Email: customer.care@haier.com.au

Fisher & Paykel Appliances Ltd, 78 Springs Road, East Tamaki, Auckland 2013. Phone: 0800 424 372. Email: customer.care@haier.co.nz

Models: AS09PBDHRA, AS12PBDHRA, AS18PDDHRA, AS24PDDHRA, AS30PFDHRA, AS20PBDHRA, AS26PBDHRA, AS35PBDHRA, AS53PDDHRA, AS71PDDHRA, AS90PFDHRA, AS09PBDHRA Split Type Room Air Conditioner, Split Type Room Air Conditioner, Room Air Conditioner, Air Conditioner

File Info : application/pdf, 12 Pages, 4.60MB

PDF preview unavailable. Download the PDF instead.

hai-aa-aircon-user-guide-AABRE8E00-AS20PBDHRA-UMv1

References

Microsoft: Print To PDF

Related Documents

Preview Haier Split Type Room Air Conditioner Operation Manual
This operation manual provides detailed instructions for the Haier Split Type Room Air Conditioner, covering parts and functions, operation modes, maintenance, troubleshooting, and customer care. It includes information on various models and features like WiFi setup and UV sterilization.
Preview Haier Split Type Room Air Conditioner Operation Manual - Models AS09PBDHRA to AS71PDDHRA
Official operation manual for Haier Split Type Room Air Conditioners. Find detailed instructions on parts, functions, operation modes (Cool, Heat, Dry, Fan, Sleep, Health), maintenance, troubleshooting, and safety precautions for models AS09PBDHRA, AS12PBDHRA, AS18PDDHRA, AS24PDDHRA, AS26PBDHRA, AS35PBDHRA, AS53PDDHRA, and AS71PDDHRA.
Preview Haier Split Type Room Air Conditioner Operation Manual
This operation manual provides detailed instructions for the Haier Split Type Room Air Conditioner, covering parts, functions, operation, maintenance, troubleshooting, and cautions. It includes information on remote controller functions, various operating modes (Cool, Heat, Dry, Fan, Auto, Sleep, Health), air flow direction adjustment, and WiFi setup.
Preview Haier Split Type Room Air Conditioner Operation Manual
Comprehensive operation manual for Haier split type room air conditioners, covering models AS09PCEHRA, AS12PCEHRA, AS18PDEHRA, AS24PEEHRA, AS25QCEHRA, AS35QCEHRA, AS50QDEHRA, AS71QEEHRA, and AS90QFDHRA. Provides detailed information on parts, functions, operation modes, remote control usage, timer settings, special functions like Turbo, Sleep, Health, and maintenance procedures.
Preview Haier Split Type Room Air Conditioner Operation Manual
This operation manual provides detailed instructions for Haier Split Type Room Air Conditioners, covering parts identification, remote controller functions, various operation modes (Cool, Heat, Dry, Quiet, Sleep, Smart, Health Airflow, ECO Sensor), maintenance, troubleshooting, and safety cautions. It lists model numbers such as AS09FBBHRA, AS12FBBHRA, AS18FEBHRA, AS24FEBHRA, AS26FBBHRA, AS35FBBHRA, AS53FEBHRA, AS71FEBHRA, AS28FFAHRA, and AS82FFAHRA.
Preview Haier Split Type Room Air Conditioner Operation Manual - Features, Operation, and Maintenance
Comprehensive operation manual for Haier split type room air conditioners, covering installation precautions, parts identification, operating modes, maintenance, troubleshooting, and safety guidelines. Provides detailed instructions for optimal use and care of Haier air conditioning units.
Preview Haier High Wall 2kW Air Conditioner AS20PBDHRA Quick Reference Guide
Quick reference guide for the Haier High Wall 2kW air conditioner (AS20PBDHRA), detailing features like UV Protect, Wi-Fi control, Coanda Plus airflow, specifications, installation, and warranty information.
Preview Haier Split Type Room Air Conditioner Operation Manual
This operation manual provides detailed instructions for the Haier Split Type Room Air Conditioner, covering parts, functions, operation modes, maintenance, troubleshooting, and specifications. Learn how to use your Haier air conditioner efficiently and safely.