OPERATION MANUAL
SPLIT TYPE ROOM AIR CONDITIONER
Model numbers include: AS09PBDHRA, AS12PBDHRA, AS18PDDHRA, AS24PDDHRA, AS26PBDHRA, AS35PBDHRA, AS53PDDHRA, AS71PDDHRA.
Please read this operation manual before using the air conditioner. Keep this operation manual for future reference. This appliance is filled with R32.
Parts and Functions
Indoor Unit
Inlet grille: The opening for air intake.
Horizontal flap: Adjusts up and down air flow. Do not adjust manually.
Air Purifying Filter: Located inside.
Vertical blade: Adjusts left and right air flow.
Display board: Shows operation mode and setting temperature.
Emergency Switch: Used for emergency operation.
Remote signal receiver: Receives signals from the remote controller.
Display board indicators: 1. Setting temp. display, 2. Operation mode indicator, 3. Remote signal receiver.
Remote controller
The remote controller has various buttons for operation:
- ON/OFF button
- TEMP +/- buttons
- FAN SPEED button
- TIMER button
- SELF CLEAN button
- LOCK button
- LIGHT button
- QUIET button
- HEAT button
- COOL button
- AUTO button
- DRY button
- SWING button
- EXTRA FUNCTION button
- CANCEL/CONFIRM button
- RESET button
Remote controller display: Shows Mode display, Signal sending display, SWING display, FAN SPEED display, LOCK display, TIMER OFF display, TIMER ON display, TEMP display.
NOTE: Cooling only units do not have displays and functions related to heating. If your unit has a healthy function, follow it; otherwise, ignore.
WiFi Setup
If your Air Conditioner has a Connected Appliance Information label, it is WiFi Connect Enabled. This allows remote monitoring and control via a smartphone. Visit www.haier.com.au/smart or www.haier.co.nz/smart for more information.
Loading of the battery
- Remove the battery cover.
- Load two R-03 batteries as illustrated, ensuring correct polarity (+/-).
- Replace the cover.
Note: The distance between the signal transmission head and the receiver hole should be within 7m. Electronic interference may affect signal reception.
Operation
Unit start / stop
Press the ON/OFF button on the remote controller to start or stop the unit.
Select temp.setting
Press the TEMP+ or TEMP- button to adjust the temperature. Each press changes the temperature by 1°C. Holding the button down will rapidly increase or decrease the temperature.
Fan speed selection
Press the FAN button to cycle through fan speeds: LOW, MED, HI, AUTO. In AUTO mode, the air conditioner automatically adjusts fan speed based on room temperature.
Air Flow Direction Adjustment
Vertical flap: Use the SWING button on the remote controller to adjust the vertical flap. Pressing SWING again stops the flap at the desired position. Use the EXTRA FUNCTION button to select positions 2 and 3 for specific airflow angles.
Cautions:
- Turn off the unit before adjusting the flap by hand.
- Avoid adjusting all vertical louvers to the left or right in high humidity to prevent condensate water.
- Do not keep the horizontal flap in a downward position for extended periods in COOL or DRY mode to prevent condensate water.
DRED Operation: Haier Peaksmart enabled air-conditioners have a Demand Response Mode. The display may show d1, d2, or d3, indicating different levels of energy consumption capping during peak demand events.
Operation Modes
The air conditioner offers several operation modes:
- AUTO: Automatically selects cooling or heating based on room temperature. Fan speed is also set to AUTO.
- COOL: For cooling operation.
- DRY: Reduces humidity. The unit runs intermittently at LOW speed when room temperature is above the set temperature +2°C.
- HEAT: For heating operation. Warm air is blown after a short delay due to cold-draft prevention.
- FAN: Operates only the fan, without cooling or heating. Temperature setting is disabled. SLEEP operation is not available in FAN mode.
Timer On/Off Operation
Set desired ON or OFF times using the TIMER button and TEMP+/- buttons. The time can be adjusted in 0.5-hour increments up to 12 hours, and then in 1-hour increments up to 24 hours. Confirm the timer setting with the CANCEL/CONFIRM button.
Self Clean Operation
The Self Clean function cleans the evaporator and condenser. Activate by pressing the Self Clean button. The display will show "CL". The function runs for 20-30 minutes and exits automatically. Pressing other buttons can exit the function early.
POWER/SOFT Operation
POWER Operation: For rapid heating or cooling. Access via EXTRA FUNCTION button.
QUIET Operation: For silent operation. Press the QUIET button. Press again to cancel.
Note: POWER operation may lead to uneven temperature distribution. QUIET operation may result in less effective cooling or heating.
Emergency operation and test operation
Emergency Operation: Use when the remote controller is defective or lost. The system automatically selects operation mode based on room temperature. Press the emergency switch once to start.
Test operation: Use when room temperature is below 16°C. Press and hold the test operation switch for more than 5 seconds until "Pi Pi" sound is heard. Cooling operation starts with HI fan speed. Test operation ends automatically after 30 minutes.
Comfortable SLEEP
The SLEEP function adjusts the temperature automatically for comfortable sleeping. It can be set for 8 hours and cannot be adjusted further. If TIMER function is also set, the SLEEP function will be cancelled if TIMER is reset.
- COOL, DRY mode: Temperature increases by 1°C after the first hour, and by another 1°C after the second hour. The unit then runs for 6 more hours before stopping.
- HEAT mode: Temperature decreases by 2°C after the first hour, and by another 2°C after the second hour. After 3 more hours, it increases by 1°C and runs for 3 more hours before stopping.
- AUTO mode: Operates according to the selected sleep mode.
- FAN mode: No SLEEP function available.
Note: If TIMER function is set, SLEEP function cannot be set up. If SLEEP is set and TIMER is reset, SLEEP is cancelled.
Power Failure Resume Function
After a power failure, the unit will run automatically after a 3-minute delay for compressor protection.
Healthy airflow Operation
This function adjusts louvers for optimal airflow. Press the EXTRA FUNCTION button to cycle through positions (upward, present, downward) and confirm with CANCEL/CONFIRM.
Note: Do not adjust the grille by hand. If the grille operates incorrectly, stop and restart the unit.
HEALTH Operation
This function utilizes UV-C light sterilization to remove harmful microorganisms. Activate by pressing the FUNCTION button until the UV indicator flashes, then press CANCEL/CONFIRM. It is recommended to use this function for 1-2 hours daily.
Attention:
- Do not look directly at the UV lamp or touch it while it is on. Turn off the sterilizing function before opening the panel.
- A tinged blue light may appear near the air conditioning inlet when the sterilizing function is on.
- The UV lamp operates only when the internal fan is running and the health function is turned on.
Maintenance
For Smart Use of The Air Conditioner
Remote Controller
Wipe with a soft, dry cloth. Do not use glass cleaner or chemical cloths.
Indoor Body
Wipe with a soft, dry cloth. For stubborn stains, use a neutral detergent diluted with water. Wring out the cloth before wiping.
Do not use the following for cleaning:
- Gasoline, benzine, thinner, or cleanser may damage the unit's coating.
- Hot water over 40°C (104°F) may cause discoloration or deformation.
Air Filter cleaning
- Open the inlet grille by pulling it upward.
- Remove the filter by pushing up the center tab and pulling downward.
- Clean the filter using a vacuum cleaner or by washing with water. Dry completely in the shade.
- Attach the filter with the "FRONT" indication facing forward. Ensure it is securely fixed.
- Close the inlet grille.
NOTE: Air purifying filter is an optional part.
Attach the standard air filter
The white side of the photocatalyst air purifying filter should face outwards, and the black side should face the unit. For the bacteria-killing medium air purifying filter, the green side faces outwards, and the white side faces the unit.
NOTE: Photocatalyst filters need solarization every 6 months. Bacteria-killing filters require frequent dusting. Store filters in a cool, dry place away from direct sunlight.
Cautions
WARNING:
- Call a Sales/Service Shop for installation. Do not attempt self-installation as improper work may cause electric shock, fire, or water leakage.
- If abnormality is found (e.g., burnt smell), stop operation immediately and contact the sales shop.
- Use an exclusive power source with a circuit breaker.
- Check proper installation of the drainage securely.
- Connect the power supply cord completely to the outlet.
- Use the proper voltage.
- Do not use the power supply cord in a bundle.
- Take care not to damage the power supply cord.
- Do not use power supply cords extended or connected in halfway.
- Do not install where flammable gas may leak.
- Do not expose the unit to vapor or oil steam.
- Do not insert objects into the air inlet or outlet.
- Do not start or stop operation by disconnecting the power supply cord.
- Do not channel air flow directly at people, especially infants or the aged.
- Do not try to repair or reconstruct the unit yourself.
- Connect the earth cable.
CAUTION:
- Do not use for storage of food, artwork, precise equipment, breeding, or cultivation.
- Take fresh air occasionally, especially when gas appliances are running.
- Do not operate the switch with wet hands.
- Do not install the unit near a fireplace or other heating apparatus.
- Check the condition of the installation stand.
- Do not place animals or plants in the direct path of the air flow.
- Do not place any objects on or climb on the unit.
- Do not pour water onto the unit for cleaning.
- Do not place flower vases or water containers on top of the unit.
Trouble shooting
Normal Performance inspection:
- Unit does not restart immediately: The system has a 3-minute protection delay after stopping or when the plug is reinserted.
- Noise is heard: Swishing or gurgling noise is normal due to refrigerant flow. Cracking noise may occur due to temperature changes. A loud airflow noise might indicate a dirty air filter.
- Smells are generated: The system may circulate smells from the interior air.
- Mist or steam are blown out: This can occur during COOL or DRY operation due to sudden cooling of indoor air.
- In dry mode, fan speed can't be changed: In DRY mode, fan speed is fixed at LOW when the room temperature is above the set temperature +2°C.
- Poor cooling: Check if the power plug is inserted, there is no power failure, the fuse is not blown, the air filter is clean, there are no obstacles at the inlet/outlet, the temperature is set correctly, doors/windows are closed, direct sunlight is blocked, and there are no excessive heat sources or people in the room.
- Multiple check: Ensure power plug is inserted, no power failure, fuse intact, air filter clean, no obstacles, correct temperature setting, closed doors/windows, no direct sunlight, and minimal heat sources/people.
Cautions
- Do not obstruct or cover ventilation grilles. Do not insert fingers or objects into the inlet/outlet or louvers.
- This appliance is not intended for use by persons with reduced physical, sensory, or mental capabilities, or lack of experience, unless supervised. Children should be supervised to ensure they do not play with the appliance.
Specifications
The refrigerating circuit is leak-proof.
The machine is adaptive in following situation:
1. Applicable ambient temperature range:
- Indoor Cooling: Max D.B/W.B 32°C/23°C, Min D.B/W.B 21°C/15°C
- Outdoor Cooling: Max D.B/W.B 46°C/26°C, Min D.B -10°C
- Indoor Heating: Max D.B 27°C, Min D.B 15°C
- Outdoor Heating: Max D.B/W.B 24°C/18°C, Min D.B -10°C
- Outdoor (INVERTER): Max D.B/W.B 24°C/18°C, Min D.B -15°C
Additional Notes:
- If the power supply cord is damaged, it must be replaced by the manufacturer or a qualified service agent.
- Indoor unit fuse type: T.3.15A/250V. Outdoor unit fuse type: T.25A/250V.
- Wiring must comply with local standards.
- Ensure the power plug is easily accessible after installation.
- Dispose of waste batteries properly.
- Supervise children to ensure they do not play with the appliance.
- Use the correct power plug that fits the power supply cord.
- Power plug and connecting cable must have local attestation.
- Turn off the A/C first, wait at least 30 seconds, then cut off the power to protect the units.
Related Documents
![]() | Haier Split Type Room Air Conditioner Operation Manual - Models AS09PBDHRA to AS71PDDHRA Official operation manual for Haier Split Type Room Air Conditioners. Find detailed instructions on parts, functions, operation modes (Cool, Heat, Dry, Fan, Sleep, Health), maintenance, troubleshooting, and safety precautions for models AS09PBDHRA, AS12PBDHRA, AS18PDDHRA, AS24PDDHRA, AS26PBDHRA, AS35PBDHRA, AS53PDDHRA, and AS71PDDHRA. |
![]() | Haier Split Type Room Air Conditioner Operation Manual This operation manual provides detailed instructions for the Haier Split Type Room Air Conditioner, covering parts and functions, operation modes, maintenance, troubleshooting, and customer care. It includes information on various models and features like WiFi setup and UV sterilization. |
![]() | Haier Split Type Room Air Conditioner Operation Manual This operation manual provides detailed instructions for the Haier Split Type Room Air Conditioner, covering parts and functions, operation modes, troubleshooting, and safety precautions. It includes information on various operating modes like COOL, DRY, HEAT, FAN, SLEEP, and HEALTH, as well as remote controller functions and maintenance tips. |
![]() | Haier Split Type Room Air Conditioner Operation Manual This operation manual provides detailed instructions for the Haier Split Type Room Air Conditioner, covering parts, functions, operation modes, maintenance, troubleshooting, and specifications. Learn how to use your Haier air conditioner efficiently and safely. |
![]() | Haier Split Type Room Air Conditioner Operation Manual Comprehensive operation manual for Haier split type room air conditioners, covering parts, functions, operation modes, troubleshooting, and maintenance. |
![]() | Haier High Wall 2kW Air Conditioner AS20PBDHRA Quick Reference Guide Quick reference guide for the Haier High Wall 2kW air conditioner (AS20PBDHRA), detailing features like UV Protect, Wi-Fi control, Coanda Plus airflow, specifications, installation, and warranty information. |
![]() | Haier Pinnacle 7.0 kW Air Conditioner: Quick Reference Guide & Specifications Comprehensive quick reference guide for the Haier Pinnacle 7.0 kW air conditioner (model AS71PDDHRA-SET). Details key features like UV Protect sterilisation, Wi-Fi and voice control, Coanda Plus airflow, Sleep mode, and Turbo mode. Includes detailed specifications on capacity, consumption, performance, dimensions, power requirements, and warranty information. |
![]() | Haier Split Type Room Air Conditioner Operation Manual - Model Guide Comprehensive operation manual for Haier split type room air conditioners, covering parts, functions, operation modes, maintenance, troubleshooting, and safety precautions. Includes model numbers AS09FBBHRA, AS12FBBHRA, AS18FEBHRA, AS24FEBHRA, AS26FBBHRA, AS35FBBHRA, AS53FEBHRA, AS71FEBHRA, AS28FFAHRA, AS82FFAHRA. |