SCS Sentinel SimplyOpen 1: Worm Screw Automation Kit for Swing Gates

This document provides comprehensive instructions for the installation, operation, and maintenance of the SCS Sentinel SimplyOpen 1 worm screw automation kit for swing gates. It is designed for residential use and requires installation by qualified personnel.

Safety Instructions

WARNING: Important safety instructions must be followed to prevent serious injury. Keep this manual for future reference. If installation is performed by a third party, this manual must be provided to the end-user, who must also be trained in the safe use of the appliance.

SCS SENTINEL motorizations comply with safety standards (EN 60335-2-103). Use of the product outside specified conditions or with non-recommended components may compromise safety. SCS SENTINEL is not liable for damages resulting from non-compliance with these instructions.

Before Installation: Ensure the gate is in good mechanical condition, balanced, and operates correctly. Verify the temperature range is suitable for the installation location. The system cannot be used with a gate incorporating a wicket gate.

Electrical Installation: Power supply installation must comply with local regulations (e.g., NF C 15-100 in France) and be performed by qualified personnel. The electrical supply must be protected by a suitable circuit breaker and residual current device. A means of disconnecting all poles of the power supply network must be provided. If the power cable is damaged, it must be replaced by the manufacturer or a qualified person.

Installation of the Motorization: Disconnect the motorization from its power source before installation. Avoid risk zones and ensure no crushing hazards exist. Be aware that manual disconnection may cause uncontrolled movement. Fixed control devices (keypads, key selectors) should be installed 1.5m from the ground, away from moving parts, and within sight of the gate. Photocellules are mandatory for automatic closing or remote operation without direct view. A flashing light may be required if the gate opens onto a public road. Ensure the mechanism is correctly adjusted and safety devices function properly. Attach the manual disconnection label permanently.

Using the Motorized System: This appliance can be used by children aged 8+ and persons with reduced capabilities if supervised or instructed. Children should not play with the appliance. Cleaning and maintenance should not be done by unsupervised children. Supervise the gate during operation and keep people away. Do not deliberately hinder gate movement.

Maintenance and Upkeep: Disconnect the power supply before cleaning or maintenance. Regularly check the installation for wear or damage. Use only original parts for repairs. Refer to Section F for detailed maintenance.

Remote Controls: Do not swallow batteries; they can cause severe internal burns. Keep batteries out of reach of children. If the battery compartment is not secure, stop using the product. Seek medical advice if a battery is swallowed. Clean remotes with a soft cloth. Replace batteries with the same type. Remove batteries if the device is not used for a prolonged period. Do not expose batteries to excessive heat.

Potential Risks

  • Risk 1: Shock and Crushing: Prevention: Obstacle detection by motor, use of photocells.
  • Risk 2: Hand Crushing: Prevention: Maintain a 10 cm minimum distance between the gate leaf and the pillar/wall. Notch the corner of the pillar without weakening it.
  • Risk 3: Imprisonment and Crushing: Prevention: Obstacle detection by motor. Maintain a 50 cm minimum distance between the motor arm and the wall.
  • Risk 4: Crushing of the Feet: Prevention: Maintain a minimum distance of 12 cm or a maximum of 5 mm between the bottom of the leaves and the floor.

Description

B1- Content

The kit includes: 2 worm screws, screws, 1 control box with electronic card, 2 remote controls, and an unlocking sticker.

B2- Dimensions

Motor dimensions: 605 mm x 67.6 mm x 68 mm.

Wiring / Installing

C1- Standard Installation

The system includes:

  • 1. 24V DC LED blinker with antenna (optional - AAM0111)
  • 2. Control box
  • 3. 24V DC gate opener (motor)
  • 4. Remote control (2 channels)
  • 5. Photocells (optional - AAM0036)

Note: Install one central stop and two side stops (not supplied) for proper gate functioning.

C2- Dimension Chart

Comply with the provided chart for correct installation. Ensure the gate moves freely, hinges are greased, there are no obstacles, and no friction during movement.

C3- Motor Fixing

Position and fix the pillar bracket according to the dimensions in the chart. For gate bracket positioning, ensure the gate is closed and the butterfly screw is 70 mm from the worm extremity.

C4- Emergency Release

In case of power failure, unscrew the butterfly screw on the gate fixing to open the gate. Permanently attach the manual disconnection device label near the operating element.

C5- Wiring Diagram

The wiring diagram illustrates the connections for the transformer, control board (P100 PCB1), antenna, solar panel, fuses, motors, photocells, flashing light, key selector, push button, and lock.

C6- Installing & Connecting Control Box

Before Installation: Determine the control box position, preferably near the gate and protected from damage. Consider the motor cable length.

Pre-Installation: Remove the cover, puncture holes for cables, fix the box to the wall, connect wires to the PCB, seal cable passages, and close the box.

Motor - Wire Connection

Ensure the white and yellow wires are stripped by 5 mm. Avoid cable tension during operation.

M1 Motor Connection & M2 Motor Connection

Diagrams show the connection of motors M1 and M2 to the electronic card, with M+ (yellow) and M- (white) wires.

Wiring to 230V Power Supply

Diagram shows the connection of the 230V power supply to the control box.

Blinker (option - AAM0111)

Instructions for connecting the blinker, including optional antenna improvement with RG58 coaxial cable.

Photocells (option - AAM0036)

Photocells are safety devices consisting of a transmitter and receiver. They trigger when the beam is interrupted. If an obstacle is detected, the gate stops and opens slightly. Installation involves cabling to the electronic card.

Setting/Using

D1- Single/Double Gate Setting (Dip Switch 1)

Switch settings: 'ON' is right, 'OFF' is left. DIP SWITCH 1: ON for double gate, OFF for single gate (MOT 1).

D2- Dip Switch 2 & 3

These switches are not used.

D3- Gate Auto-Close Adjustment (Dip Switch 4)

ON: Automatic closing after 30 seconds. Pressing two remote keys simultaneously turns OFF automatic mode (3 blinker flashes). Repeat to turn ON.

Note: Photocellules are required for automatic closing.

OFF: Automatic closing OFF (can still be activated by remote).

D4- Photocell Adjustment (Dip Switch 5)

ON: Photocells ON. Obstacle during closing stops and opens the gate for 2 seconds. If an obstacle is detected when the gate is fully open, the closing time resets.

OFF: Photocells OFF. No influence on gate operation.

D5- Dephasing of Leaves (Dip Switch 6)

ON: 8-second delay for closing/opening.

OFF: 5-second delay for closing/opening.

D6- Slowing Down

Operating speeds are not adjustable.

D7- LED Indication

LED1: System Learning/RF signal. LED2: System learning (blinks twice/sec normally, once/sec during learning; static means learning can be repeated). LED3: Photocells (on when misaligned or obstacle detected). LED4: Start (on when transmitter, key selector, or push button is activated).

D8- Remote Controls Learning Process

Add Remotes: Press 'RF-Learn' until LED1 lights up. Press remote button; LED1 flashes twice, stays lit for 10s, then goes out. Remote memorized.

Delete Remotes: Hold RF button until LED1 goes out.

D9- System Learning Process for Double Leaf Gate

1. Set Switch 1 to ON.

2. Unlock motors, position leaves at mid-travel, re-lock motors.

3. Hold 'SYS-learn' button until LED2 blinks once/sec, then release.

4. Press left remote button.

5. Learning sequence: MOT2 closes, MOT1 closes, MOT1 reopens, MOT2 reopens, MOT2 closes, MOT1 closes. (If motors open instead of closing, interrupt, reverse polarity, and restart).

Note: If learning is incomplete, LED2 remains lit. Check connections and repeat.

D10- System Learning Process for Single Leaf Gate

1. Set Switch 1 to OFF.

2. Connect motor to MOT1 output.

3. Unlock motor, position leaf at mid-travel, re-lock motor.

4. Hold 'SYS-learn' button until LED2 blinks once/sec, then release.

5. Press right remote button.

6. Learning sequence: Leaf closes, reopens, closes. (If it opens instead of closing, interrupt, reverse polarity, and restart).

D11- Obstacle Detection

If an obstacle is detected during opening, the gate stops. If detected during closing, the gate stops, reopens, and closes again. When reaching the closing stop, it reopens to clear any obstacle.

Technical Features

Motor

  • Type: 24V DC motor, Worm screw
  • Stroke Length: 290 mm
  • Power Supply: 24V DC
  • Max Gate Weight/Length: 150 kg / 1.5 m per leaf
  • Operating Temperature: -20°C to +50°C
  • Dimensions: 605 mm x 68 mm x 67.6 mm
  • Sound Pressure Level: ≤ 70 dB(A)

Remote Controls

  • Channels: 2
  • Frequency/Power: 433.92 MHz - power < 10mW
  • Power Supply: 1 x CR2032 lithium battery
  • Security: Rolling code technology

Blinker (option - AAM0111)

  • Antenna: Yes (coaxial cable not supplied)
  • Bulb: LED E14 24V 1W (included)
  • Power Cable: 2 x 1 mm² (not included)
  • Bulb Connection: Unpolarized (electronic card connection)
  • Screws: Included
  • Operating Temperature: -20°C to +50°C
  • Dimensions: 74 x 167 x 59 mm

Photocells (option - AAM0036)

  • Detection Method: Infrared Beam
  • Sensing Range: MAX 10 m
  • Input Voltage: 12-24V AC/DC
  • Response Time: < 100ms
  • Operation Indicator: RX: Red LED On (beam broken) / Off (beam aligned); TX: Red LED On
  • Dimensions: 63 x 63 x 30 mm
  • Output Method: Relay Output

Maintenance

F1- Motor

Perform maintenance every 6 months, or more frequently with high usage.

Disconnect Power Supply: Clean and lubricate screws, pins, and hinges. Check fastening points and wire connections.

Connect Power Supply: Check power adjustments, manual release function, and photocell/safety device function.

F2- Remote Control

Illustrations show remote control and battery replacement.

Technical Assistance

G1- Troubleshooting

  • Gate doesn't move: Check LED1, battery voltage, LED2 status, wiring connections, and fuse.
  • Short transmission distance: Check antenna terminals and transmitter battery.
  • Flashing light not working: Check wiring and LEDs.
  • Leaves stop suddenly/move in one direction: Check gate freedom of movement, wiring, fuse, photocell beam, and disconnect power to check gate movement.
  • Master gate closes first, slave stops: Check gate freedom of movement, wiring, fuse, safety beam, and disconnect power to check gate movement. Increase power with switches 2 & 3.
  • Motors not running, relay noisy: Check fuse.
  • No remote control connection: Check LED1, RF1 receiver, remote association (LED1 & LED4), battery, and plug-in receiver.
  • Remove remote controls: Hold RF button until LED1 flashes.

G2- Online Assistance

For personalized assistance, use the online chat on www.scs-sentinel.com.

Warranty

SCS Sentinel provides a warranty period beyond the legal time. Proof of purchase (invoice/barcode) is required. Warranty does not cover damage from improper installation, misuse, non-SCS Sentinel components, lack of maintenance, physical shock, or weather damage.

Warnings

Do not dispose of batteries or old products with household waste. Dangerous substances can harm health and the environment. Use selective collection methods or return products to your retailer.

Declaration of Conformity

SCS Sentinel declares that this product complies with essential requirements of Directive 2014/53/EU and Directive 2006/42/EC. The Declaration of Conformity can be found at www.scs-sentinel.com/downloads.

Models: MVE0115 Pour Portail Battant, MVE0115, Pour Portail Battant, Portail Battant, Battant

PDF preview unavailable. Download the PDF instead.

d7ccd1e5d7cdd2cb3a77078013a7892fa1b670fe Adobe InDesign 19.4 (Windows) Adobe PDF Library 17.0

Related Documents

Preview SCS Sentinel OneGate 1 Swing Gate Motorization Kit Installation and User Manual
Comprehensive guide for installing and operating the SCS Sentinel OneGate 1 worm screw automation kit for swing gates. Covers safety, components, wiring, installation, settings, maintenance, and troubleshooting.
Preview SCS Sentinel OpenGate 1 MVE0100 Swing Gate Automation Kit Manual
Comprehensive manual for the SCS Sentinel OpenGate 1 MVE0100 swing gate automation kit, covering installation, operation, maintenance, and troubleshooting. Includes technical specifications and safety guidelines.
Preview SCS Sentinel OpenGate 1 MVE0100 Swing Gate Automation Kit Manual
Comprehensive guide to the SCS Sentinel OpenGate 1 MVE0100 swing gate automation kit, covering installation, wiring, settings, maintenance, and troubleshooting.
Preview SCS Sentinel OpenGate 1 MVE0100 Swing Gate Automation Kit - Installation and User Manual
Comprehensive guide for the SCS Sentinel OpenGate 1 MVE0100 swing gate automation kit, covering installation, wiring, settings, maintenance, and troubleshooting. Features 24V DC motors for residential use.
Preview SCS Sentinel SimplyOpen 1+ Swing Gate Motorization Installation and User Manual
Comprehensive guide for the SCS Sentinel SimplyOpen 1+ actuator automation kit for swing gates. Covers installation, wiring, operation, maintenance, safety precautions, and troubleshooting for model MVE0116.
Preview SCS Sentinel SCS 1 Motorisation Kit for Swing Gates - Installation and User Manual
Comprehensive guide for the SCS Sentinel SCS 1 swing gate motorization kit, covering installation, wiring, settings, maintenance, and troubleshooting. Features 24V DC motors, remote controls, and safety photocells.
Preview SCS Sentinel OpenGate 1 MVE0100 Swing Gate Automation Kit Manual
Comprehensive manual for the SCS Sentinel OpenGate 1 MVE0100 automation kit for swing gates, covering installation, safety, technical specifications, maintenance, and troubleshooting.
Preview SCS Sentinel OpenGate 2 & VisioDoor 7+RFID: Installation and User Manual
Comprehensive guide for SCS Sentinel's OpenGate 2 articulated arm gate automation system and VisioDoor 7+RFID video intercom system, covering installation, setup, features, maintenance, and troubleshooting.