REHAU NEA SMART 2.0 R-Module 230 V

Quick Install Guide

⚠️ Safety Instructions and Product Conformity

Risk of electric shock! Danger to life!

Electrical installation must be performed by qualified personnel (electrician or electronics engineer) in accordance with applicable national and local regulations and energy supplier requirements.

  • Always read the instructions carefully before starting installation.
  • All installation work must be performed with the system de-energized (power disconnected).
  • Disconnect any external voltages at the relay contacts and secure against unintended activation.
  • Always check for the absence of voltage before proceeding.

REHAU AG + Co hereby declares that the radio equipment type Nea Smart 2.0 complies with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at: www.rehau.com/neasmart2.

System Overview

The REHAU NEA SMART 2.0 system includes various components designed for intelligent room control. Key elements include:

  • R-Module 230 V: The central module for system expansion.
  • Base 230 V: The main control unit, providing power and connectivity.
  • Room Unit: Features a digital display (e.g., showing '20.5') for temperature and settings, and user interface.
  • Various other modules and connectors for system integration.

Scope of Delivery

The package typically includes:

  • 1x R-Module 230 V
  • Base unit
  • Room Unit
  • Cables and connectors
  • Mounting hardware

(Note: Exact contents may vary based on the specific system configuration.)

Installation

Wall Installation

Follow these steps for mounting the unit on a wall:

  1. Attach the unit to a wall bracket using screws (labeled 'a' and 'b'). Detail 'C' shows a clip mechanism.
  2. Connect the necessary cables to the terminal blocks on the rear of the unit.
  3. Insert the unit into its mounting position.
  4. Drill holes as indicated (represented by a drill icon) for secure mounting.
  5. Secure the unit using screws.

DIN Rail Installation

For installation on a standard DIN rail:

  1. Mount the DIN rail using screws.
  2. Clip the unit onto the DIN rail. Detail 'C' shows a locking mechanism.
  3. Secure the unit on the rail using a lever or clip.
  4. Connect the required cables to the unit's terminals.

Electrical Connections

The system involves connecting the R-Module 230 V to the Base 230 V unit and other components. Key connection points and functions are:

R-Module 230 V Terminals:

  • ZOBUS1, ZOBUS2: System bus connections for communication with other modules and the Base unit.
  • DI1: Digital Input 1.
  • RZ9 - RZ12: Relay outputs (numbered 1 and 2 for each).
  • RELAY1, RELAY2: Terminal designations for relay connections.
  • L, N: Power connections (230 V AC).

Base 230 V Terminals (Refer to page 15 for detailed layout):

  • 230 V AC L, N: Main power input.
  • GND: Ground connection.
  • IN 230V / OUT 230V: Power input/output terminals.
  • RELAY 1-4: Relay outputs.
  • RZ1 - RZ8: Relay outputs.
  • DI 1, DI 2: Digital Inputs.

System Bus (ZOBUS)

The ZOBUS connection links the Room Unit to the Base unit, enabling communication and control.

Terminal Functions (from pages 19-20):

LabelEnglish Description
Zone BusZone Bus
Digital Input 1Digital Input 1
Zone 9-12Zone 9-12
Relay 1 5A, Class 2Relay 1 5A, Class 2
Relay 2 5A, Class 2Relay 2 5A, Class 2
Fuse T2AFuse T2A

(Note: Terminal labels and functions may vary slightly across different languages provided in the document.)

Cable Specifications

The following cable types and sizes are recommended for electrical connections:

  • Solid cable: 0.5 - 1.5 mm²
  • Flexible cable (multiple stranded): 1.0 - 1.5 mm²

(A diagram shows an 8 mm cable diameter.)

Models: NEA SMART 2.0 Room Thermostat, NEA SMART 2.0, Room Thermostat, Thermostat

File Info : application/pdf, 24 Pages, 1.84MB

PDF preview unavailable. Download the PDF instead.

nea-smart-2-0-r-module-230-v-quickinstall

References

Adobe PDF Library 16.0.7

Related Documents

Preview NEA SMART 2.0 Service Manual: Installation and Operation Guide
Comprehensive service manual for the REHAU NEA SMART 2.0 system, detailing installation, setup, operation, and troubleshooting for designers, installers, and service partners. Covers features like room temperature control, heating/cooling, dehumidification, and smart functions.
Preview REHAU NEA SMART 2.0 Transformer: Quick Installation Guide
This guide provides essential safety instructions, package contents, and installation options for the REHAU NEA SMART 2.0 Transformer. It details DIN rail and wall mounting, connection diagrams, and technical notes for efficient setup.
Preview REHAU NEA H 24 V & 230 V Room Thermostat: User Manual & Quick Installation Guide
Discover efficient and precise temperature control for your heating systems with the REHAU NEA H 24 V and 230 V room thermostats. This comprehensive user manual and quick installation guide provides detailed information on features, installation, operation, and parameter settings for optimal performance and energy savings.
Preview REHAU NEA SMART 2.0 Service Manual: Professional Guide
Comprehensive service manual for the REHAU NEA SMART 2.0 smart building control system. Covers installation, operation, and troubleshooting for HVAC professionals, detailing features for intelligent heating, cooling, and room temperature management.
Preview REHAU NEA SMART 2.0 Room Unit Quick Install Guide
This guide provides quick installation instructions for the REHAU NEA SMART 2.0 Room Unit, covering safety precautions, system overview, installation steps, and error messages.
Preview REHAU NEA SMART 2.0: Smart Underfloor Heating Control
Discover the REHAU NEA SMART 2.0 system for intelligent and efficient underfloor heating control. This system offers smart room temperature regulation, app-based control, and energy-saving features for optimal home comfort.
Preview REHAU NEA SMART 2.0: Intelligent Room-by-Room Heating and Cooling Regulation
Discover REHAU NEA SMART 2.0, an elegant and discreet intelligent system for regulating underfloor heating and cooling. This system offers intuitive installation, remote control via smartphone or tablet, and smart features like geofencing and window opening detection to optimize comfort and reduce energy costs by up to 20%. Learn about the different components, including control units, room thermostats (wired and wireless), and actuators.
Preview REHAU NEA SMART 2.0 Room Unit: Installation Guide and Specifications
Comprehensive guide to installing and configuring the REHAU NEA SMART 2.0 Room Unit, including safety instructions, technical specifications, and error code explanations. Learn how to pair the unit with zones and set up external sensors.