Owner's Manual for STERLING models including: 77301100, 77301100 Air Massage Bath, Air Massage Bath, Massage Bath, Bath
File Info : application/pdf, 2 Pages, 239.36KB
DocumentDocumentLawson® 72" x 36" air massage bath 77301100 Features · 15-1/4" soaking depth · Reversible drain can be installed as left- or right-hand drain · Suitable for tile-down applications · Air Massage, three-speed blower, integrated heater, arched armrests, contoured backrest and lumbar support Material · Made from solid Vikrell® material for strength, durability, and lasting beauty Installation · Drop-in Recommended Products/Accessories 71317100 Tile-in flange kit for 72" soaking baths Codes/Standards ASME A112.19.7/CSA B45.10 CSA B45.5/IAPMO Z124 ASTM E162 ASTM E662 UL 1795 CSA C22.2 No. 218.2 STERLING® Vikrell® or Acrylic Baths and Shower Bases Ten-Year Limited Warranty See website for detailed warranty information. 1-800-STERLING (1-800-783-7546) Kohler Co. reserves the right to make revisions without notice to product specifications. For the most current Specification Sheet, go to www.sterlingplumbing.com. 3-24-2024 21:23 - US Lawson® 72" x 36" air massage bath 77301100 57-3/8" (1457 mm) 43-3/8" (1102 mm) 28-3/4" (730 mm) 14-3/4" (375 mm) 12" 24" (305 mm) (610 mm) 8" (203 mm) 4" (102 mm) 11-3/4" (298 mm) 18" (457 mm) Drain Cutout Ø 2" (51 mm) Drain 72-1/8" (1832 mm) Min 72-1/4" (1835 mm) Max 34-1/4" (870 mm) 35-1/4" (895 mm) Ledger Strip Locations Recommended Support Clip or Roofing Nail Location (5 Total) Overflow Detail 3-5/16" (84 mm) 5-7/8" (149 mm) 72" (1829 mm) 20-5/16" (516 mm) 36" (914 mm) Required Electrical Service One dedicated circuit required, protected with Class A Ground- Fault Circuit-Interrupter (GFCI). Outside North America, this device may be known as a Residual Current Device (RCD). Blower, Heater: 120 V, 15 A, 60 Hz Technical Information All product dimensions are nominal. Drain location: Reversible Basin area, bottom: 50-3/8" x 21-3/4" (1280 mm x 552 mm) Basin area, top: 58-1/4" x 27" (1480 mm x 686 mm) Weight: 83 lbs (37.6 kg) Minimum floor load: 41 lbs/ft² (200.2 kg/m²) Water depth: 15-1/4" (387 mm) Water capacity: 68 gal (257.4 L) Electrical component Blower: 120 V, 9.2 A, 60 Hz rating: Heater: 300 W Minimum flat for 3" (76 mm) door: Notes Install this product according to the installation instructions. Provide one grounded electrical outlet within 24" (610 mm) of each component. Size the drain cutout to fit the drain assembly that will be used. Blower service access is required. End stud positioning is critical if nailing-in flanges are to be used. Studs should be positioned roughly as shown for support clip or roofing nail installation. 1-800-STERLING (1-800-783-7546) Kohler Co. reserves the right to make revisions without notice to product specifications. For the most current Specification Sheet, go to www.sterlingplumbing.com. 3-24-2024 21:23 - US