BENETECH GM1371 Humidity and Temperature Meter Instruction Manual
Model: GM1371
BENETECH
Introduction
A temperature and humidity meter is used to measure the temperature and humidity of the environment so as to determine the environmental conditions under which products are produced or stored. It can also be widely used in daily life.
Product Features
- • Large screen LCD display
- • °C/°F switch display
Version: GM1371-EN-01
LCD Display
The LCD display shows temperature, humidity, time, and date. The display areas are:
- A: Temperature display area
- B: Humidity display area
- C: Time display area
- D: Year/month/day display area
Example display: 27.9°C 50% 19:09 2022/4/27
Button Function
Number | Button | Button Status | Definition |
---|---|---|---|
1 | System setting button ⚙️ | Long press for 3 seconds | Enter the setting state |
2 | Up button + | Short press when there is no setting | Switch between the 24-hour and 12-hour system |
Short press to set | The number will increase when setting | ||
3 | Down button - | Short press when there is no setting | °C/°F unit switch |
Short press to set | The number will decrease when setting |
Operation Method
To set the time and date:
- Long press the setting button for about 3 seconds to enter the 12/24-hour system. Press the "+" or "-" button to switch between the 24-hour and 12-hour system. (The 12-hour system displays AM in the morning and PM in the afternoon).
- Press the setting button for the second time to start the hour setting. Press the "+" and "-" buttons to adjust.
- Press the setting button for the third time to enter the sub-setting (minute setting). Press the "+" and "-" buttons to adjust.
- Press the setting button for the fourth time to start the year setting. Press the "+" and "-" buttons to adjust.
- Press the setting button for the fifth time to start the month setting. Press the "+" and "-" buttons to adjust.
- Press the setting button for the sixth time to start the day setting. Press the "+" and "-" buttons to adjust.
- Press the setting button for the seventh time to restore the display interface and exit the setting state.
If there is no operation in any of the setting interfaces for about 60 seconds, the parameter will be retained while exiting the setting state.
Technical Parameters
Product model | GM1371 |
Product size | 100*62*15mm |
Product weight | 76.5g (with battery) |
Display mode | LCD |
Time formats | Month/Day-HH:MM(12/24) |
Measurement range | Temperature measurement range: -9.9°C~60°C (14.18°F~140°F) Humidity measurement range: 10%~99%RH |
Measurement accuracy | Temperature accuracy: ±2°C (±3.6°F) Humidity accuracy: ±5%RH |
Resolution | Temperature resolution: 0.1°C (0.1°F) Humidity resolution: 1%RH |
Battery specification | CR2032 3V |
Announcements
1. The machine is a precision instrument. Damage caused by the user's own dismantlement is not covered by warranty.
2. The operating environment should be clean. Corrosive gas or dust will reduce the measurement accuracy and the product life.
Particulars Furnished:
The Company is not responsible for any derivative results of the use of the product;
The Company reserves the right to change the product design and the contents of the manual. Changes may be made without prior notice!
Certifications: CE [WEEE symbol]