Pelgrim Induction Hob Installation Instructions
Important Safety Information
This appliance must only be connected by a registered and qualified installer. Please read the safety regulations.
The appliance must only be installed by a qualified technician. Please read the safety regulations.
Cet appareil ne peut être installé que par un technicien agréé. Lisez les instructions de sécurité.
Dieses Gerät darf nur von einem anerkannten Installateur angeschlossen werden! Bitte lesen Sie die Sicherheitsbestimmungen.
Preparations for Installation
Pictograms Used
- Important Information: Important information to know.
- Electrical Connection: Electrical connection required.
Clearance Around Appliance
Free space around the appliance is crucial for proper ventilation and operation. Ensure the following minimum clearances:
Dimension | Value (mm) |
---|---|
A (min.) | 650 |
C (min.) | 450 |
D (min.) | 40 |
Diagram showing clearances A, C, and D around the hob.
Electrical Connection Requirements
This appliance must be earthed.
The appliance must not be connected to the mains via a socket or extension lead, as safe use cannot be guaranteed.
Das Gerät darf nicht über einen Verteiler oder ein Verlängerungskabel an die Stromversorgung angeschlossen werden, da dabei die sichere Verwendung nicht garantiert werden kann.
Cet appareil ne doit pas être branché sur le réseau par l'intermédiaire d'une prise multiple ou d'une rallonge. La sécurité d'utilisation de l'appareil ne pourrait alors plus être garantie.
Connected Load / Power Ratings
The following table details the connected load for various Pelgrim models:
Model | L1 (W) | L2 (W) | L3 (W) | Total Load (W) |
---|---|---|---|---|
IKA7072 | 3700 | 3700 | - | 7400 |
IKA7084ANT | 3700 | 3000 | - | 7400 |
IKA7085 | 3700 | 3000 | - | 7400 |
IKA7093 | 3700 | 3000 | 3700 | 10400 |
IKA7094 | 3700 | 3000 | - | 7400 |
Dimensions for Installation
Refer to the following dimensions for correct installation of the hob:
Model | A (mm) | B (mm) | C (mm) | D (mm) | E (mm) |
---|---|---|---|---|---|
IKA7072 | 560 | 600 | 490 | 50 | 56 |
IKA7084ANT | 750 | 600 | 490 | 50 | 56 |
IKA7085 | 750 | 600 | 490 | 50 | 56 |
IKA7093 | 810 | 600 | 490 | 50 | 56 |
IKA7094 | 810 | 600 | 490 | 50 | 56 |
Diagram showing installation dimensions A, B, C, D, and E for the hob.
Accessibility
Ensure proper accessibility for maintenance and operation.
Diagram illustrating accessibility requirements.
Placing Sealing Tape
Apply the sealing tape to the worktop as shown in the diagram for a proper seal.
Diagram showing the placement of sealing tape on the worktop.
Electrical Connection Details
Connection for IKA7072, IKA7084ANT, IKA7085, and IKA7094
This section details the electrical connection for the specified models. Ensure the correct wiring configuration is used.
Connection Types:
- 2N 380-415V 50/60Hz - 2x 16A: Requires 2 phases and 1 neutral. Wire cross-section: 4x1.5mm² (less than 2m).
- 2-2N 220-240V 50Hz - 2x 16A: Requires 2 phases and 2 neutrals. Wire cross-section: 5x1.5mm² (less than 2m).
- 1 1N 220-240V 50/60Hz - 1x 40A: Requires 1 phase and 1 neutral. Wire cross-section: 5x1.5mm² (less than 2m).
Diagrams illustrating the wiring for different voltage and phase configurations.
Connection for IKA7093
Specific connection details for the IKA7093 model:
Connection Types:
- 3N 380-415V 50/60Hz - 3x 16A: Requires 3 phases and 1 neutral. Wire cross-section: 5x1.5mm² (less than 2m).
- 1 1N 220-240V 50/60Hz - 1x 48A: Requires 1 phase and 1 neutral. Wire cross-section: 3x10mm².
- 1 1N 220-240V 50/60Hz - 1x 40A: Requires 1 phase and 1 neutral. Wire cross-section: 3x6mm².
Diagrams illustrating the wiring for the IKA7093 model.
Important Note for NL Installations
Only NL / Alleen NL: The 2 phases of the hob circuit breaker must be supplied by 1 residual current device. It is not permitted to run L1/N1 via a different residual current device than L2/N2.
Finalizing the Connection
Consult the connection diagrams on the back of the appliance and make the required connections on the terminal block.
Diagram showing the terminal block and connection points (L1, L2, L3, N1, N2).
Note: To achieve the best hob performance, a ventilation gap as large as possible is advised.
Diagram showing minimum clearances (min. 20 mm) for ventilation.