PRESSURE GAUGE WITH DIAPHRAGM SEAL MS-100
- Casing diameter Ø100
- Material of casing, process connection and measuring element – stainless steel
- Accuracy 1%
A photograph of the APLISENS MS-100 pressure gauge. It features a circular dial with measurements ranging from -0.1 to 0.6 MPa, with a needle indicating the current pressure. The gauge has a robust stainless steel casing and a process connection at the bottom.
Use
Burdon tube pressure gauges are mechanical pressure measuring devices, which are sensitive to many factors typical of industrial applications. The use of diaphragm seals will significantly improve the reliability of the pressure gauge, and is often a necessary condition for measurements to be made.
Pressure gauges with appropriate diaphragm seals are used:
- to measure the pressure of media which are:
- contaminated, viscous, solidifying,
- at high or low temperature,
- chemically reactive;
- in cases of:
- mechanical vibration of the system,
- pulsating pressure;
- where there is a need for:
- protection of the system against unsealing in case of a fault with the manometer,
- aseptic measurement conditions in the food and pharmaceuticals industries.
The full range of diaphragm seals which can be used with pressure gauge is described in detail in Chapter III: Diaphragm Seals. The temperature range of the medium measured using a pressure gauge with diaphragm seal depends on the choice of diaphragm seal and may lie between -60 and +315°C.
With an appropriate selection of pressure gauge and diaphragm seal, taking into account the width of the measurement range, the measurement accuracy of the unit is in accordance with the precision class of the pressure gauge. Detailed recommendations concerning the range of usability of diaphragm seals combined with manometers are contained in Chapter III: Diaphragm Seals.
Technical data
Standard measurement ranges:
0...1, 1.6, 2.5, 4, 6, 10, 16, 25, 40, 60, 100, 160, 250, 400 bar
-1...0, 0.6, 1.5, 5, 9, 15 bar
Accuracy:
1%
Diameter of the casing:
Ø100
Material of the casing:
0H18N9 (304ss)
Material of process connection and measuring element:
H17N13M2T (316Ti)
Process connection:
diaphragm seal
Process connection outlet:
bottom (special version: back)
Special versions
glycerine:
casing filled with glycerine
T:
back connection
Ordering procedure
A visual guide illustrating the ordering procedure for the MS-100 pressure gauge. It shows a sequence of fields to be filled: the model name (MS-100), followed by placeholders for the measurement range, special version (e.g., glycerine, T), and the type of diaphragm seal, referencing diaphragm seal data sheets. It also mentions available certificates like MC3.1 and NACE compliance.
Ordering format: MS-100 / [Measurement range] / [Special version: glycerine, T] / [Type of diaphragm seal according to the diaphragm seals data sheets]
Certificates: MC3.1 - Material certificate, NACE - NACE MR-01-75 comply
Example:
MS-100 pressure gauge / range 0 ÷ 6 bar / glycerine / DN50PN40 diaphragm seal
MS-100 / 0 ÷ 6 bar / glycerine / S-P-DN50PN40