EMM 3- 24DC/500AC-IFS - Motor Management
Item Number: 2297497
Manufacturer: Phoenix Contact
Product URL: https://www.phoenixcontact.com/gb/products/2297497
Product Overview
Electronic motor management for operation with external current transformers. Features active power measurement for overload and underload monitoring of motors and systems, providing optimum protection for all performance classes. Offers freely parameterizable switching and signaling thresholds.
Your Advantages
- Optional connection to INTERFACE system and PROFIBUS-GATEWAY-IFS via TBUS.
- Freely parameterizable signaling or switching thresholds.
- Digital outputs control external switching elements.
Commercial Data
Item number | 2297497 |
Packing unit | 1 pc |
Minimum order quantity | 1 pc |
Sales key | DK7512 |
Product key | DK7512 |
GTIN | 4046356175753 |
Weight per piece (including packing) | 263 g |
Weight per piece (excluding packing) | 263 g |
Customs tariff number | 85371098 |
Country of origin | DE |
Technical Data
Notes
Utilization restriction: EMC: class A product, see manufacturer's declaration in the download area.
Product properties
Product type | Electronic motor manager |
Product family | CONTACTRON |
Operating mode | 100% operating factor |
Electrical properties
Number of phases | 3 |
Maximum power dissipation for nominal condition | 2.5 W |
Test voltage input/output | 8 kV |
Supply
Rated control circuit supply voltage US | 24 V DC |
Control supply voltage range | 19.2 V DC ... 30 V DC |
Rated control supply current IS | 25 mA |
Switching threshold | 9.6 V DC ("0" signal) 19.2 V DC ("1" signal) |
Insulation characteristics
Rated insulation voltage | 500 V |
Rated surge voltage | 6 kV |
Overvoltage category | III |
Degree of pollution | 2 |
Insulation characteristics between the input and output circuits | Safe isolation (IEC 60947-1) |
Insulation characteristics between the thermistor input and output | Basic insulation (IEC 60947-1) |
Input data
Digital inputs
Number of inputs | 4 (IN1 - IN4) |
Rated actuating voltage UC | 24 V DC |
Rated actuating current IC | 3.3 mA |
Voltage measuring input V1, V2, V3
Input voltage range | 42 V AC ... 575 V AC |
Typical input current at UN | < 0.5 mA |
Current measuring input L1/T1, L2/T2, L3/T3
Typical input current at UN | 5 A (Secondary external converter) |
Power measurement
Basic accuracy | typ. 2% |
Power range | 4.5 kW (x amplitude transmission factor for current transformer) |
Voltage measurement/star voltage
Basic accuracy | typ. 0.75% |
Voltage range | 0 V AC ... 350 V AC (Phase-to-neutral voltage) |
Current measurement
Basic accuracy | typ. 0.5% |
Current range | 140 mA ... 5 A |
Measuring via | External push-through current transformers connected upstream |
Output data
Output name | Acknowledging contacts O1-O4 |
Note | The meaning of the acknowledgement outputs can be freely parameterized, see user manual. |
Number of outputs | 4 |
Nominal output voltage | 24 V DC (semiconductor output) |
Output voltage range | 19.2 V DC ... 30 V DC |
Continuous load current | 500 mA |
Residual voltage | < 200 mV |
Protective circuit | Suppressor diode |
Surge voltage protection | > 33 V DC |
Connection Data
Control circuits
Connection method | Screw connection |
Stripping length | 8 mm |
Screw thread | M3 |
Conductor cross section rigid | 0.2 mm² ... 2.5 mm² |
Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
Conductor cross section AWG | 24 ... 14 |
Load circuit
Connection method | Screw connection |
Stripping length | 8 mm |
Screw thread | M3 |
Conductor cross section rigid | 0.2 mm² ... 2.5 mm² |
Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
Conductor cross section AWG | 24 ... 14 |
Signaling
Status display | LED (yellow) |
Operating voltage display | Green LED |
Error indication | Red LED |
Data communication display | green LED |
Dimensions
Width | 22.5 mm |
Height | 99 mm |
Depth | 114.5 mm |
Material Specifications
Color | gray (RAL 7042) |
Environmental and Real-Life Conditions
Ambient conditions
Degree of protection | IP20 |
Ambient temperature (operation) | -25 °C ... 70 °C |
Ambient temperature (storage/transport) | -25 °C ... 70 °C |
Approvals
ATEX
Identification | II (2) G [Ex e] [Ex d] [Ex px] II (2) D [Ex t] [Ex p] |
Certificate | PTB 10 ATEX 3024 |
UL, USA/Canada
Certificate | NKCR.E140324 |
Safety Integrity Level (SIL, IEC 61508)
Identification | ≤ 1 |
Note | Safe shutdown |
Safety Integrity Level (SIL, IEC 61508)
Identification | 1 |
Note | Motor protection |
Category (ISO 13849)
Identification | ≤ 1 |
Note | Safe shutdown |
Performance Level
Identification | ≤ b |
Note | Safe shutdown |
Standards and Regulations
Standards/regulations | EN 60947 EN 60947-4-2 |
Mounting
Mounting type | DIN rail mounting |
Assembly note | in rows with zero spacing |
Mounting position | Vertical (horizontal DIN rail) |
Drawings
Connection diagram
A connection diagram illustrates the wiring for the EMM 3-24DC/500AC-IFS module. It shows connections for power supply, digital inputs (IN1-IN4), digital outputs (O1-O4), thermistor input (Th1, Th2), and current measurement inputs (I/L1, I/L2, I/L3 and T1/L1, T2/L2, T3/L3). It also indicates connections for external switching modules and a motor (M).
Diagrams illustrating operational status
Several diagrams illustrate the device's performance monitoring capabilities:
- Machine tool for milling: Shows real power (P) over time (t). Features include switch-on delay, delay time, excess performance due to possible broken tool, increased performance/tool wear, performance threshold (broken tool), signaling threshold (tool wear), and performance when idling.
- Air bubbles in motor-operated pumps: Shows real power (P) over time (t). Features include switch-on delay, delay time, temporary dry running, upper performance threshold, signaling threshold (contamination of screen or filter), performance, and lower performance threshold.
- Dry run in motor-operated pumps: Shows real power (P) over time (t). Features include switch-on delay, continuous dry running with forced shutdown, performance, and lower performance threshold.
Block diagram
A block diagram shows the internal components and connections of the EMM 3-24DC/500AC-IFS. It includes the logic microcontroller (μP), digital inputs, digital outputs, IFS-Port, Reset button, Thermistor input, T-BUS connection, and various input/output terminals (Us, IN1-IN4, O1-O4, US0, V1-V3, I1, I21, I31, I12, I22, I32, Th1, Th2).
Classifications
ECLASS | ECLASS-13.0 | 27370804 |
ETIM | ETIM 9.0 | EC002572 |
UNSPSC | UNSPSC 21.0 | 39121100 |
Environmental Product Compliance
EU RoHS | Fulfills EU RoHS substance requirements | Yes |
Exemption | 7(a), 7(c)-1, 7(c)-II | |
China RoHS | Environment friendly use period (EFUP) | EFUP-50 |
An article-related China RoHS declaration table can be found in the download area for the respective article under "Manufacturer declaration". For all articles with EFUP-E, no China RoHS declaration table issued and required. | ||
EU REACH SVHC | REACH candidate substance (CAS No.) | Lead(CAS: 7439-92-1) |
SCIP | 141e0f24-6c49-48b6-a9f1-f1b2bd215171 |