EMM 3- 24DC/500AC-16-IFS - Motor Management
Product Number: 2297523
Manufacturer: Phoenix Contact
Product URL: https://www.phoenixcontact.com/us/products/2297523
Overview
Electronic motor management with integrated current transformers up to 16 A, providing active power measurement for overload and underload monitoring of motors and systems for optimum protection. Features freely parameterizable switching and signaling thresholds.
Your Advantages
- Optional connection to INTERFACE system and PROFIBUS-GATEWAY-IFS via TBUS
- Digital outputs control external switching elements
- Freely parameterizable signaling or switching thresholds
Commercial Data
Item number | 2297523 |
---|---|
Packing unit | 1 pc |
Minimum order quantity | 1 pc |
Sales key | C475 |
Product key | DK7511 |
GTIN | 4046356175777 |
Weight per piece (including packing) | 262.4 g |
Weight per piece (excluding packing) | 225.2 g |
Customs tariff number | 85371098 |
Country of origin | DE |
Technical Data
Notes
Utilization restriction: EMC: class A product, see manufacturer's declaration in the download area.
Product Properties
Product type | Electronic motor manager |
---|---|
Product family | CONTACTRON |
Operating mode | 100% operating factor |
Electrical Properties
Number of phases | 3 |
---|---|
Maximum power dissipation for nominal condition | 5.5 W |
Test voltage input/output | 8 kV |
Supply
Rated control circuit supply voltage Us | 24 V DC |
---|---|
Control supply voltage range | 19.2 V DC ... 30 V DC |
Rated control supply current Is | 25 mA |
Switching threshold | 9.6 V DC ("0" signal) 19.2 V DC ("1" signal) |
Insulation Characteristics
Rated insulation voltage | 500 V |
---|---|
Rated surge voltage | 6 kV |
Overvoltage category | III |
Degree of pollution | 2 |
Insulation characteristics between the input and output circuits | Safe isolation (IEC 60947-1) |
Insulation characteristics between the thermistor input and output | Basic insulation (IEC 60947-1) |
Input Data
Digital inputs (IN1 - IN4) | 4 (IN1 - IN4) |
---|---|
Number of inputs | 24 V DC |
Rated actuating voltage Uc | 3.3 mA |
Rated actuating current Ic | |
Voltage measuring input V1, V2, V3 | 42 V AC ... 575 V AC |
Input voltage range | < 0.5 mA |
Typical input current at UN | |
Current measuring input L1/T1, L2/T2, L3/T3 | ≤ 16 A |
Typical input current at UN |
Power Measurement
Basic accuracy | typ. 2% |
---|---|
Power range | 14 kW |
Voltage Measurement/Star Voltage
Basic accuracy | typ. 0.75% |
---|---|
Voltage range | 0 V AC ... 350 V AC (Phase-to-neutral voltage) |
Current Measurement
Basic accuracy | typ. 0.5% |
---|---|
Current range | 400 mA ... 16 A |
Measuring via | Internal current transformer |
Output Data
Output name | Acknowledging contacts O1-O4 |
---|---|
Note | The meaning of the acknowledgement outputs can be freely parameterized, see user manual |
Number of outputs | 4 |
Nominal output voltage | 24 V DC (semiconductor output) |
Output voltage range | 19.2 V DC ... 30 V DC |
Continuous load current | 500 mA |
Residual voltage | < 200 mV |
Protective circuit | Suppressor diode |
Surge voltage protection | > 33 V DC |
Connection Data
Control Circuits
Connection method | Screw connection |
---|---|
Stripping length | 8 mm |
Screw thread | M3 |
Conductor cross section rigid | 0.2 mm² ... 2.5 mm² |
Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
Conductor cross section AWG | 24 ... 14 |
Load Circuit
Connection method | Screw connection |
---|---|
Stripping length | 8 mm |
Screw thread | M3 |
Conductor cross section rigid | 0.2 mm² ... 2.5 mm² |
Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
Conductor cross section AWG | 24 ... 14 |
Signaling
Status display | LED (yellow) |
---|---|
Operating voltage display | Green LED |
Error indication | Red LED |
Data communication display | green LED |
Dimensions
Width | 22.5 mm |
---|---|
Height | 99 mm |
Depth | 114.5 mm |
Material Specifications
Color | gray (RAL 7042) |
---|
Environmental and Real-Life Conditions
Ambient Conditions
Degree of protection | IP20 |
---|---|
Ambient temperature (operation) | -25 °C ... 70 °C |
Ambient temperature (storage/transport) | -25 °C ... 70 °C |
Approvals
ATEX
Identification | II (2) G [Ex e] [Ex d] [Ex px] II (2) D [Ex t] [Ex p] |
---|---|
Certificate | PTB 10 ATEX 3024 |
UL, USA/Canada
Certificate | NKCR.E140324 |
---|
Safety Integrity Level (SIL, IEC 61508)
Identification | ≤ 1 |
---|---|
Note | Safe shutdown |
Safety Integrity Level (SIL, IEC 61508)
Identification | 1 |
---|---|
Note | Motor protection |
Category (ISO 13849)
Identification | ≤ 1 |
---|---|
Note | Safe shutdown |
Performance Level
Identification | ≤ b |
---|---|
Note | Safe shutdown |
Standards and Regulations
Standards/regulations | EN 60947 EN 60947-4-2 |
---|
Mounting
Mounting type | DIN rail mounting |
---|---|
Assembly note | in rows with zero spacing |
Mounting position | Vertical (horizontal DIN rail) |
Drawings
Connection Diagram
A diagram shows the connection of the EMM 3- 24DC/500AC-16-IFS. It illustrates the power supply, digital inputs (IN1-IN4), digital outputs (O1-O4), thermistor input (Th1, Th2), current measurement inputs (L1/T1, L2/T2, L3/T3), and the connection to a motor (M). The diagram also includes labels for "Current measurement", "EMM 3-.../500AC-16-IFS", "Power supply", "Digital outputs", "Thermistor input", "Current measurement", "Reverse running", "Separate switching module", and "Forward running".
Status Monitoring: Machine Tool for Milling
A graph illustrates the real power (P) over time (t) for status monitoring in a machine tool for milling. It shows a "Switch-on delay", "Delay time", "Motor startup", "Tool positioning", "Milling process", and "Drive shutdown". The graph depicts "Excess performance due to possible broken tool", "Increased performance / Tool wear", "Performance threshold / Broken tool", and "Signaling threshold / Tool wear". The performance level is shown to fluctuate during the milling process, with a baseline "Performance when idling".
Status Monitoring: Air Bubbles in Motor-Operated Pumps
A graph illustrates the real power (P) over time (t) for status monitoring of air bubbles in motor-operated pumps. It shows a "Switch-on delay" and "Delay time". The graph depicts "Temporary dry running" and "Performance". It includes an "Upper performance threshold" and a "Signaling threshold, contamination of screen or filter", as well as a "Lower performance threshold".
Status Monitoring: Dry Run in Motor-Operated Pumps
A graph illustrates the real power (P) over time (t) for status monitoring of dry run in motor-operated pumps. It shows a "Switch-on delay" and "Delay time". The graph depicts "Continuous dry running with forced shutdown" and "Performance". It includes a "Lower performance threshold".
Block Diagram
A block diagram shows the internal structure of the EMM 3- 24DC/500AC-16-IFS. It includes inputs for power supply (Us), digital inputs (IN1-IN4), and thermistor inputs (Th1, Th2). The processing unit consists of a "Logic μP" with "IFS-Port" and "Reset" functions. Digital outputs (O1-O4) are provided, along with status indicators (DAT, ERR, L, R). The diagram also shows connections for the motor (P) and the T-BUS for communication.
Classifications
ECLASS | ECLASS-13.0: 27370804 |
---|---|
ETIM | ETIM 9.0: EC002572 |
UNSPSC | UNSPSC 21.0: 39121100 |
Environmental Product Compliance
EU RoHS | Fulfills EU RoHS substance requirements |
---|---|
Exemption | 7(a), 7(c)-1, 7(c)-II |
China RoHS | EFUP-50. An article-related China RoHS declaration table can be found in the download area for the respective article under "Manufacturer declaration". For all articles with EFUP-E, no China RoHS declaration table issued and required. |
EU REACH SVHC | REACH candidate substance (CAS No.): Lead(CAS: 7439-92-1) |
SCIP | 07341960-8044-459e-a799-c66798d5ef18 |
Company Information
Phoenix Contact 2025 - all rights reserved
Phoenix Contact USA
586 Fulling Mill Road
Middletown, PA 17057, United States
(+717) 944-1300
info@phoenixcon.com