CAN/RS485 Matched Hybrid Inverter Brands
Brand | Model No. | Communication Protocol | Cable Supply |
---|---|---|---|
Felicitysolar | IVEM series IVGM5048 IVGM10048 IVGM15048 IVPS/IVPM/IVPA series | RS485 | RJ45 |
Deye | SUN- 3 / 3.6 / 5 / 6 K-SG04LP1-EU. SUN- 3.6 / 5 / 6 K-SG03LP1-EU. SUN- 3.6 / 5 / 6 / 7.6 / 8 K SG05LP1-EU. SUN- 5 / 6 K-SG01LP1-US. SUN- 7.6 / 8 K-SG01LP1-US/EU. SUN- 5 / 6 / 8 / 10 / 12 K SG04LP3-EU. SUN-12 / 14 / 16 K-SG01LP1-EU. | RS485/CAN | RJ45 |
Luxpower | LXP 3.6K/4.6K/5K Hybrid LXP 3600 ACS series. LXP-LB-EU 6-8K LXP-LB-EU 8-10K LXP-LB-EU 12K | CAN | RJ45 |
Growatt | SPF 3500 -5000 ES SPF 6000 ES Plus | RS485/CAN | RJ45 |
Voltronic | Infini Solar V IV TWIN 6/6.5/ 8kw Axpert VM III Axpert VM IV Axpert MKS III Axpert MKS IV Axpert MAX Axpert MAX II | RS485 | RJ45 |
Sunsynk | SUNSYNK-3.6/5/8K-SG01LP1 SYNK-8/10/12K-SG04LP3 SUNSYNK MAX | RS485 | RJ45 |
Megarevo | R(5-8)KLNA R(6-15)KH3 R(3-6)KL1 | CAN/RS485 | RJ45 |
Victron | To ensure successful communication, please use this Cerbo GX box to communicate with our battery. | CAN | RJ45 |
SRNE | HF4830S60-H/HF4850S80-H HF4835U60-H/HF4850U80-H HF4850S80 -145 HF4830U60 -145/HF4835U80 -145 HES48(80-120)S200-H HES48(80-120)U200-H HES48(40-60)S200-H | RS485 | RJ45 |
Solis | S6-EH1P(3-6)K-L-EU S6-EH1P8K-L-PRO S5-EH1P(3-6)K-L | CAN | RJ45 |
MPPsolar | PIP-MT SERIES U-GK/U-MS SERIES PIP-MKX SERIES PIP-MAX SERIES PIP-MGX SERIES PIP-MK SERIES PIP-GK SERIES | RS485 | RJ45 |
Afore | AF(1-3.6)K-SL AF(3-6)K-SL | CAN | RJ45 |
SOFAR | HYD 3000-6000-EP | CAN | RJ45 |
CHISAGE ESS | MARS-5-14G2-LE MARS-5-14G1-LE JUP-5-10G2-LE | CAN | RJ45 |
Communication Pin Definitions
The corresponding communication pins are defined in the following tables. You can make communication cables according to these tables.
(1) RS485 Protocol Pins Defined
[RJ45 Connector Diagram: Pins labeled 1 through 8]
NO. | Felicitysolar | Deye | LuxPower | Growatt | Voltronic | MegaRevo | SRNE | Mppsolar |
---|---|---|---|---|---|---|---|---|
Pin1 | GND | RS485B | RS485B | RS485B | x | x | x | x |
Pin2 | x | RS485A | RS485A | RS485A | x | x | GND | x |
Pin3 | x | GND | x | x | RS485B | x | x | x |
Pin4 | x | x | x | x | x | x | x | RS485-A |
Pin5 | RS485B | x | x | x | RS485A | x | x | RS485-B |
Pin6 | RS485A | GND | x | x | x | x | x | x |
Pin7 | x | RS485A | x | x | x | RS485A | RS485A | x |
Pin8 | x | RS485B | GND | x | GND | RS485B | RS485B | GND |
(2) CAN Protocol Pins Defined (General Brands)
This table lists CAN protocol pin definitions for various brands. Note: Felicitysolar's specific CAN pinout for general use is not detailed in this section of the document.
NO. | Victron | Solis | Deye | MegaRevo | Growatt | Afore | SOFAR |
---|---|---|---|---|---|---|---|
Pin1 | x | x | x | x | x | x | x |
Pin2 | x | x | x | x | x | x | x |
Pin3 | CAN_L | x | x | x | x | x | x |
Pin4 | CAN_H | x | CAN_H | CAN_H | CAN_H | CAN_H | CAN_H |
Pin5 | x | x | CAN_L | CAN_L | CAN_L | CAN_L | CAN_L |
Pin6 | x | x | x | x | x | x | x |
Pin7 | CAN_H | x | x | x | x | x | x |
Pin8 | CAN_L | x | x | x | x | x | x |
(3) Example: Communication Cable for Felicitysolar Battery to Victron Inverter
For example, if you want to let our LPBA48100-OL battery communicate with a Victron inverter directly, you need to make a communication cable like the one below.
NO. | Felicitysolar | Victron |
---|---|---|
Pin1 | x | x |
Pin2 | x | x |
Pin3 | x | x |
Pin4 | x | x |
Pin5 | x | x |
Pin6 | x | x |
Pin7 | CAN_L | CAN_H |
Pin8 | CAN_H | CAN_L |