Guangzhou Felicity Solar Technology Co., Ltd.
Address: No. 2, Donghua Huaye Road, Renhe Town, Baiyun Area, Guangzhou, China
Website: www.felicitysolar.com
Inverter Matching List
Felicitysolar hereby authorizes the compatibility of its low voltage battery packs with the following brands of hybrid inverters.
CAN/RS485 Matched Hybrid Inverter Brands
Brand | Model No. | Communication Protocol | Cable Supply |
---|---|---|---|
Felicitysolar | IVEM series IVGM5048 IVGM10048 IVGM15048 IVPS/IVPM/IVPA series | RS485 | Rj45 |
Deye | SUN- 3 / 3.6 / 5 / 6 K-SG04LP1-EU. SUN- 3.6 / 5 / 6 K-SG03LP1-EU. SUN- 3.6 / 5 / 6 / 7.6 / 8 K SG05LP1-EU. SUN- 5 / 6 K-SG01LP1-US. SUN- 7.6 / 8 K-SG01LP1-US/EU. SUN- 5 / 6 / 8 / 10 / 12 K SG04LP3-EU. SUN-12 / 14 / 16 K-SG01LP1-EU. | RS485/CAN | Rj45 |
Luxpower | LXP 3.6K/4.6K/5K Hybrid LXP 3600 ACS series. | RS485 | Rj45 |
Growatt | SPF 3500 ES / SPF 5000 ES | RS485/CAN | Rj45 |
Voltronic | Infini Solar V IV TWIN 6/6.5/ 8kw Axpert VM III Axpert VM IV Axpert MKS III Axpert MKS IV Axpert MAX Axpert MAX II | RS485 | Rj45 |
Sunsynk | SUNSYNK-3.6/5/8K-SG01LP1 SYNK-8/10/12K-SG04LP3 SUNSYNK MAX | RS485 | Rj45 |
Megarevo | R8KLNA R7K6LNA R6KLNA R5KLNA | RS485/CAN | Rj45 |
Victron | Only LPBA48100-OL and EC series battery can communicate directly. Other series of batteries need to communicate with our communication box. | CAN | Rj45 |
SRNE | HF4830S60-H/HF4850S80-H HF4835U60-H/HF4850U80-H HF4850S80 -145 HF4830U60 -145/HF4835U80 -145 | RS485 | Rj45 |
Solis | S6-EH1P(3-6)K-L-EU S6-EH1P8K-L-PRO | CAN | Rj45 |
MPPsolar | PIP-MT SERIES U-GK/U-MS SERIES PIP-MKX SERIES PIP-MAX SERIES PIP-MGX SERIES PIP-MK SERIES PIP-GK SERIES | RS485 | Rj45 |
Afore | AF(3-6)K-SL | CAN | Rj45 |
SOFAR | HYD 6000-EP | CAN | Rj45 |
Communication Pin Definitions
The corresponding communication pins are defined in the following tables. You can make communication cables according to this information.
(1) RS485 Protocol Pins Defined
Diagram: An illustration of an RJ45 connector showing pin numbering from 1 to 8.
NO. | Felicitysolar | Deye | LuxPower | Growatt | Voltronic | MegaRevo | SRNE | Mppsolar |
---|---|---|---|---|---|---|---|---|
Pin1 | GND | RS485B | RS485B | RS485B | X | X | X | X |
Pin2 | X | RS485A | RS485A | RS485A | X | X | GND | X |
Pin3 | X | GND | X | X | RS485B | X | X | X |
Pin4 | X | X | X | X | X | X | X | RS485-A |
Pin5 | RS485B | X | X | X | RS485A | X | X | RS485-B |
Pin6 | RS485A | GND | X | X | X | X | X | X |
Pin7 | X | RS485A | X | X | X | RS485A | RS485A | X |
Pin8 | X | RS485B | GND | X | GND | RS485B | RS485B | GND |
(2) CAN Protocol Pins Defined
NO. | Felicitysolar | Victron | Solis | Deye | MegaRevo | Growatt | Afore | SOFAR |
---|---|---|---|---|---|---|---|---|
Pin1 | X | X | X | X | X | X | X | CAN_H |
Pin2 | X | X | X | X | X | X | X | CAN_L |
Pin3 | CAN_L | X | X | X | X | X | X | X |
Pin4 | CAN_H | X | CAN_H | CAN_H | CAN_H | CAN_H | CAN_H | X |
Pin5 | X | X | CAN_L | CAN_L | CAN_L | CAN_L | CAN_L | X |
Pin6 | X | X | X | X | X | X | X | X |
Pin7 | CAN_L (Just for EC and LPBA48100-OL) | CAN_H | X | X | X | X | X | X |
Pin8 | CAN_H (Just for EC and LPBA48100-OL) | CAN_L | X | X | X | X | X | X |
(3) Example: Making a Communication Cable
For example, if you want to connect a Felicitysolar LPBA48100-OL battery to a Victron inverter directly, you need to make a communication cable as illustrated below.
Diagram: A table showing pin connections for Felicitysolar and Victron for CAN communication.
NO. | Felicitysolar | Victron |
---|---|---|
Pin1 | X | X |
Pin2 | X | X |
Pin3 | X | X |
Pin4 | X | X |
Pin5 | X | X |
Pin6 | X | X |
Pin7 | CAN_L | CAN_H |
Pin8 | CAN_H | CAN_L |
Visual Description: A photograph shows two hands holding two RJ45 connectors with attached cables. One connector is labeled "Victron" and the other is labeled "Felicitysolar", indicating the physical appearance of the communication cable ends.