Nimly Touch Pro Manual

Outside unit

Before you start

Read the user manual carefully and familiarize yourself with the contents of the product box.

You need this for the installation

Phillips screwdriver, heavy duty pliers, the included tool/security screw bit. Do not use an electric drill! Remove the existing locking system before installation.

IMPORTANT INFORMATION

Our products are supplied with emergency keys for a mechanical backup solution, which must be stored outside your home. The emergency keys must be available in the event of an emergency, such as drained battery, component failure following vandalism or similar instances. Contact customer service immediately if you suspect a product fault.

Nimly disclaims all liability and costs related to missing emergency key(s).

Verify compatibility

The product is compatible with both right- and left hinged doors (50-90 mm), recessed according to the Scandinavian standard (SS 817375:2018) for front doors.

Ensure that the included striker plate and mortise fit in the door and door frame before proceeding. If there are deviations in the milling from the door manufacturer, conduct the necessary modification before carrying out the installation.

Installation Steps

Step 1: Locate your emergency keys

Unbox all content inside the product box, familiarize yourself with all the items and locate the included emergency keys. Make sure you always have the emergency keys available during installation. Test the keys in the keyhole on the outdoor unit.

Step 2: Install the striker plate

Mount the striker plate in your door frame, using the existing screws. The rectangular side must face outwards and be easily placed in the recessed area of the door frame.

If needed, you may readjust the adjustment tabs after the complete installation, to ensure that the position of the door is correct.

Step 3: Install the mortise

Verify that the latch bolts are set in the correct direction, with the inclined side towards the door frame. If necessary, remove the front plate and rotate the latch bolts in the correct direction for your door. Mount the mortise in your door, using the existing screws. It should slide into place without much resistance.

Unable to reach the screw behind the hook bolt? Retract the hook bolt, by using a door handle or other suitable tool to turn the square spindle hole.

Step 4: Attach the outside unit

Place the rubber seal and the outside unit on the door. Make sure that the recessed area of the gasket is mounted towards the back of the lock. The red mark on the square spindle must point upwards for the lock to work properly. Pass the wire through the top hole of the mortise. Make sure the gasket seals evenly around the outside unit.

Step 5: Adjust the cuttable screws

Adjust the cuttable screws so that they correspond to the thickness of the door and add an extra threaded portion. Use powerful pliers to cut to the desired length. The length should be equal on all screws. Cut further if necessary.

Step 6: Attach the inside bracket

Locate the screw holes in the mortise, looking from the inside. Place the supplied insulation in both door holes. Mount the inside bracket with the cuttable screws. Two screws at the top and two at the bottom.

Tighten carefully with a Phillips screwdriver. Do not use a drill. Ensure that the rubber seal on the outside unit seals evenly.

Step 7: Connect the inside unit

Place the rubber seal on the inner bracket and connect the cable to the inside unit. Make sure that the seal covers the entire bracket evenly.

Optional: Did you purchase nimly Connect Module? Install the Connect Module in the inside unit, before proceeding.

Step 8: Position the inside unit

Insert the excess cord into the door to prevent it from getting caught. Slide the inside unit carefully into place and ensure that the gasket seals evenly around the inside unit.

Step 9: Attach the inside unit

Fit the inside of the lock by fastening both the short security screws in the battery holder and the longest security screw at the bottom of the unit. Use the included screw bits and tighten carefully. Install all batteries and the battery cover. Store the included bit/tool in a safe place.

Step 10: Install handles

Mount both handles. The exterior door handle has a hole for the key cylinder. Place the handles in the desired direction for your door and use the supplied tool/bit to fasten the screws.

Before you continue: Pull the inside handle downwards. The handle should move easily and pull the latches into the mortise. If you feel unexpected resistance, the lock may be mounted crookedly on the door or too tight. Push the smallest latch on the mortise in and verify that the hook bolt extends. Pull the inside handle down again to retract the hook bolt back into the mortise.

Step 11: Test all functions of the lock

Make sure the lock works with your emergency keys before closing the door. Insert the emergency key and turn it 90°, so the key is horizontal in the cylinder. The outside handle will now be engaged and you may open the door mechanically. Remove the key and store one or more of these safely outside your home.

Test the lock electronically with factory code 123#. Unlock is confirmed by a green flash and a short tone.

Step 12: Complete the installation

Close the door and verify that the hook bolt extends upon closure. The smallest latch in the middle of the mortise should engage the hookbolt, once it is pushed in by the center part of the striker plate.

If the gap between the door frame and the door becomes too large, you can use the included spacer behind the striker plate.

Touch Pro Use & Operation

Outside unit

Inside unit

Touch Pro Programming Manual

All programming sequences are entered on the outside unit.

TIP! WRITE DOWN WHICH USER SLOT EACH USER IS ASSIGNED. SEE THE FORM AT THE BACK.

Before you continue: did you purchase our Connect Module & Gateway? Install the module according to its own instructions and carry out the programming by using the application.

Otherwise, continue with the next step to continue with manual programming.

First master code

This is a unique programming code that is used for manual registration of user codes, activation and deactivation of functions and other settings on the lock.

User slot 000 is reserved for your first master code.

The factory code is 123.

Enter

Example

All codes can contain up to 8 digits, we recommend at least 6 for improved security.

*A 6 digit master code is required when connecting to our nimly connect app with accessories.

The code panel will confirm successful registration with a short green flash and tone, red flashes indicates that the entry was unsuccessful. You may have used too long time.

Optional: More master codes

Need more master codes? It is optional to register more.

User slot 001 and 002 are reserved for more master codes.

The first master code was registered in the previous step.

Enter

Example

All codes can contain up to 8 digits, we recommend at least 6 for improved security.

The code panel will confirm successful registration with a short green flash and tone, red flashes indicates that the entry was unsuccessful. You may have used too long time.

Well done!

Treat yourself to a short break, if you wish. In the next step, you will register your fingerprint for programming and access.

First master finger

This is a unique master finger that is used for access and registration of more fingerprints. A master finger cannot be deleted, only overwritten.

The first master finger will automatically be assigned user slot 000.

Enter

Make sure you have a clean fingerprint during registration.

The code panel will confirm successful registration with a short green flash and tone, red flashes indicates that the entry was unsuccessful. You may have used too long time.

Optional: more master fingers

Need multiple master fingers? It is optional to register more.

User slot 001 and 002 are reserved for more master fingers.

The first master finger was registered in the previous step.

Unlock with fingerprint:

The code panel will confirm successful registration with a short green flash and tone. Red flashes indicates that the entry was unsuccessful. You may have used too long time.

Add user finger

This is a unique user finger that is used for access only.

User slot 003 to 199 are reserved for user fingers.

Masterfinger(s) was registered in the previous steps.

Enter

The code panel will confirm successful registration with a short green flash and tone, red flashes indicates that the entry was unsuccessful. You may have used too long time.

Delete user finger

Find out which user location the fingerprint you wish to delete is registered under and carry out the following programming.

Enter

Masterfinger(s) was registered previously.

The code panel will confirm successful registration with a short green flash and tone, red flashes indicates that the entry was unsuccessful. You may have used too long time.

Add user codes

This is a unique user code that is assigned to a specific user and is used as an access code. The code can only be used for access.

User slot 003 to 999 are reserved user codes.

Enter

A Master code from previous steps is used for programming.

Example

All codes can contain up to 8 digits, we recommend at least 4 for improved security.

Unlock with access code: enter your code and end with * or # to confirm the entry

The code panel will confirm successful registration with a short green flash and tone, red flashes indicates that the entry was unsuccessful. You may have used too long time.

Delete user code

If a unique user code is to be deleted, you must know which user location the code was first registered at. The sequence is confirmed by a beep.

Enter

Example

Master codes cannot be deleted, only overwritten to new master codes.

Enter: * User slot Master code * new master code * new master code again *

Example: * 000 345678* new master code * new master code again *

Add key tags

These are unique key tags that are assigned to a specific user. Key tags can only be used for access.

User slot 003 to 999 are reserved key tags.

Enter

A Master code from previous steps is used for programming.

Example

We recommend using our nimly tags. Tags from other manufacturers may be supported, if they use Mifare classic protocol.

Unlock with key tag: place the key tag close to the panel

The code panel will confirm successful registration with a short green flash and tone, red flashes indicates that the entry was unsuccessful. You may have used too long time.

Delete key tag

If a unique key tag is to be deleted, you must know which user location the tag was first registered at. The sequence is confirmed by a green flash and a beep.

Enter

Example

Key tags can be deleted without having access to the tag itself. If a key tag goes missing, we recommend deleting it from its user location as soon as possible.

Deactivate automatic relock

Autolock is pre-selected. If autolock is deactivated (open mode), you will have to change the lock status between locked and open yourself manually, by using an access method from the outside unit or use the inside unit.

Enter

A Master code from previous steps is used for programming.

The lock will remain locked after deactivating the function, until you change the lock status yourself.

Example

Test the function to verify that it is activated.

The code panel will confirm successful registration with a short green flash and tone, red flashes indicates that the entry was unsuccessful. You may have used too long time.

Reactivate automatic relock

Autolock is pre-selected. Automatic relock will lock the outside unit 7 seconds after unlocking.

Enter

A Master code from previous steps is used for programming.

Lock the outside unit with your access code after reactivation.

Read more about temporary open mode on the use & operation page.

Deactivate camouflage function

The camouflage function is pre-selected. The function allows you to enter false digits before and after the actual access code will be disabled.

Enter

A Master code from previous steps is used for programming.

The lock will remain locked after deactivating the camouflage function.

Example

Test the function to verify that it is deactivated.

The code panel will confirm successful registration with a short green flash and tone, red flashes indicates that the entry was unsuccessful. You may have used too long time.

Reactivate camouflage function

The function allows you to enter false digits before and after your actual access code, to camouflage your code to others. For example, if your code is 3456, you may enter 21345681 #. The lock recognizes the correct sequence.

Enter

A Master code from previous steps is used for programming.

The lock will remain locked after reactivating the camouflage function.

Example

Test the function to verify that it is activated.

Activate anti-tamper function

If the wrong code is entered three times in a row, the function deactivates the outside unit code panel for 5 minutes.

Enter

A Master code from previous steps is used for programming.

The lock will remain locked after activating the anti-tamper function.

Example

Test the function to verify that it is activated.

The code panel will confirm successful registration with a short green flash and tone, red flashes indicates that the entry was unsuccessful. You may have used too long time.

Deactivate anti-tamper function

The function that disables the outside unit code panel when tampering is detected, will be disabled.

Enter

A Master code from previous steps is used for programming.

The lock will remain locked after deactivating the anti-tamper function.

Example

Test the function to verify that it is deactivated.

Change volume

The lock emits an operating sound at the level normal. The tone level can be changed to low or silent. Enter sequence and the desired level.

0 Silent 1 Low 2 Normal

Enter

A Master code from previous steps is used for programming.

The lock will remain locked after changing the volume.

Example

The lock confirms successful entry with a beep in the newly entered tone level.

The code panel will confirm successful registration with a short green flash and tone, red flashes indicates that the entry was unsuccessful. You may have used too long time.

Code requirement for the key tag and fingerprint function

The function activates a code requirement when you use the fingerprint function or key tag. Codes can still be used independently.

Activate requirement

Enter

Deactivate requirement

Enter

The code panel will confirm successful registration with a short green flash and tone, red flashes indicates that the entry was unsuccessful. You may have used too long time.

Reset

Resetting will delete all registered fingerprints, codes and key tags on the lock. Settings on the lock will remain.

Uninstall the inside unit from your door. If you are in doubt about how this is done, you may review the installation instructions from before.

After the inside unit is removed, place the connector cable back and reinsert the batteries.

Turn the inside unit around with the backside towards you and hold down the gold-colored reset button on the circuit board.

The lock confirms successful reset by emitting a long beep and green flash. Verify by testing the lock. Factory code 123# is resetted.

Models: TouchPro Smart Door Lock, TouchPro, Smart Door Lock, Door Lock, Lock

File Info : application/pdf, 16 Pages, 406.38KB

PDF preview unavailable. Download the PDF instead.

EN-Touch-Pro-Installation-Manual-150324 Adobe InDesign 18.3 (Macintosh) Adobe PDF Library 17.0

Related Documents

Preview Nimly Connect Gateway Installation Guide
Step-by-step installation guide for the Nimly Connect Gateway, covering setup, app integration, device pairing, and range optimization for smart home security.
Preview Nimly Connect Module Installation Guide
A comprehensive guide to installing and setting up the Nimly Connect Module for smart home integration, including pairing instructions and troubleshooting.
Preview Nimly Connect Gateway Quick Installation Guide
Step-by-step guide to installing and setting up the Nimly Connect Gateway, connecting it to your smart lock and home network.
Preview nimly Connect Gateway Installation Guide
Step-by-step installation guide for the nimly Connect Gateway, covering network setup, app download, account creation, device pairing, and range extension. Includes essential components and support information.