User Guide for Kentec models including: Taktis, Fire Alarm Control Panel
Taktis Quick Start Guide. This Start Guide describes 2 to 8 loop and 2 to 16 loop models of the Kentec Taktis FACP (Fire Alarm Control Panel). This Quick Start Guide covers.. View
Taktis Quick Start Guide Man-1172EN Rev. 04 Taktis Quick Start Guide 1 Taktis Quick Start Guide This Start Guide describes 2 to 8 loop and 2 to 16 loop mo dels of the Kentec Taktis FACP (Fire Alarm Control Panel).
File Info : application/pdf, 16 Pages, 1.42MB
DocumentDocumentFire Alarm Control Panel Taktis Quick Start Guide Man-1172EN Rev. 04 Taktis Quick Start Guide *Man-1172EN* Taktis Quick Start Guide Taktis Quick Start Guide This Start Guide describes 2 to 8 loop and 2 to 16 loop models of the Kentec Taktis FACP (Fire Alarm Control Panel). This Quick Start Guide covers: · What's in the box? · QR Codes · Panel at a Glance · Hanging the Enclosure · Compliance · Terms & Conditions What's in the box? The Taktis FACP includes the following components and hardware. Figure A-1 Items in the box (NOT TO SCALE) 1x Control Panel 1x Pre-mounted Power Supply 2x Enclosure Lock Keys 2x 1x Enable Key Switch Power Supply Keys Accessory Pack 1 x Quick Start Guide Man-1172EN Rev. 04 Taktis Quick Start Guide 1 Taktis Quick Start Guide QR Codes The QR codes below provide links to the Taktis FACP Installation and Operation Manuals. Using your Smartphone, tablet or device install a third party QR Code Reader and scan the code to open the documents. Figure A-2 Reading the QR Codes Installation Manual Operation Manual Should you be unable to work with QR codes Manuals can be obtained by visiting the following website pages: Manual Variant Installation Manual Operation Manual Website http://www.kentec.co.uk/manuals/man-1154GEN.pdf http://www.kentec.co.uk/manuals/man-1169GEN.pdf Man-1172EN Rev. 04 Taktis Quick Start Guide 2 Taktis Quick Start Guide Panel at a Glance The diagrams below provide an overview of the panel main components and features: Figure A-3 2 to 8 Loop Panel Internal Layout 1 2 3 4 5 6 4 7 10 8 9 ID Description 1 Panel Indicators 2 Hinge Pin 3 Touch Panel Display 4 Hinge Loops 5 Upper Panel Fascia Comment Refer to Installation Manual for details. Refer to Installation Manual for details. Refer to Installation & Operation Manuals for details. Refer to Installation Manual for details. Refer to Installation Manual for details. ID Description 6 Enable Keyswitch 7 Lower Panel Fascia 8 Zone Indicators 9 Printer (Optional) 10 Panel Lock Clearance Comment Refer to Installation & Operation Manuals for details. Refer to Installation Manual for details. Up to 144 Zone Indicators. Refer to Installation Manual for details. Refer to Installation Manual for details. - Man-1172EN Rev. 04 Taktis Quick Start Guide 3 Figure A-4 2 to 8 Loop Panel Chassis Layout 14 13 12 1 2 3 4 2 5 Taktis Quick Start Guide 1 11 10 2 9 8 7 6 1 1 ID Description Enclosure Fixing 1 Hole 2 Field Terminals 3 PCB Cover fixing 4 Ribbon Cable Header 5 PCB Cover 6 Battery 7 Main Chassis Comment Use 5mm bolts/screw fixings. Refer to fixing the cabinet in installation section for details. Refer to Installation Manual for details. Refer to Installation Manual for details. Refer to Installation Manual for details. ID Description Main Board 8 9 Cable Tie Point 10 Power Supply 11 Earth Terminals Comment Refer to Installation Manual for details. Refer to Installation Manual for details. Power supply varies depending on version.5.25A shown. For field wiring. Refer to Installation Manual for details. Refer to Appendix section to determine battery type. Refer to Installation Manual for details. 12 Knock-out 28mm dia. 13 Knock-out 21mm dia. 14 Earth Link Refer to Installation Manual for details. Refer to Installation Manual for details. For continuity only. Refer to Installation Manual for details. Man-1172EN Rev. 04 Taktis Quick Start Guide 4 Taktis Quick Start Guide Figure A-5 2 to 8 Loop Panel Rear of Door 1 2 3 6 4 5 5 1 ID Description 1 Hinge Loops 2 Earth Link 3 Upper Opening Comment Refer to Installation Manual for details. For continuity only. Refer to Installation Manual for details. - ID Description 4 Lower Opening 5 Product Label/Logo Position 6 Panel lock Comment - - Man-1172EN Rev. 04 Taktis Quick Start Guide 5 Figure A-6 2 to 16 Loop Front Panel Layout 1 2 3 4 6 Taktis Quick Start Guide 5 ID Description 1 Panel Indicators 2 Touch Panel Display 3 Enable Keyswitch Comment ID Description Refer to Installation Manual for details. 4 Zone Indications Refer to Installation and Operation Manuals for details. 5 Panel Lock Refer to Operation Manual for details. 6 Printer (Optional) Comment Up to 144 Zone Indications. Refer to Installation Manual for details. - Refer to Installation Manual for details. Man-1172EN Rev. 04 Taktis Quick Start Guide 6 Taktis Quick Start Guide Figure A-7 2 to 16 Loop Panel Internal Layout 16 15 14 1 1 2 3 13 4 3 5 3 5 12 6 11 7 3 3 2 8 10 9 2 1 ID Description Enclosure fixing hole 1 2 Hinge Loop 3 Field Terminals 4 PCB Cover Fixing 5 Ribbon Cable Header 6 Cable Tie Point 7 Main Board 8 Chassis Locating Lug Man-1172EN Rev. 04 Taktis Quick Start Guide 7 Comment Use 5mm bolts/screws fixings. Refer to fixing the cabinet in installation section for details. Refer to Installation Manual for details. Refer to Installation Manual for details. Refer to Installation Manual for details. Refer to Installation Manual for details. Refer to Installation Manual for details. Refer to Installation Manual for details. Refer to Installation Manual for details. ID Description Battery 9 10 Power Supply 11 Example Board 12 Board Slot 13 Main Chassis 14 Knock-out 28mm dia. 15 Knock-out 21mm dia. 16 Earth Link Comment Refer to Installation manual for details. Power supply varies depending on version.10.25A shown. Refer to Installation Manual for details. Refer to Installation Manual for details. Refer to Installation Manual for details. Refer to Installation Manual for details. Refer to Installation Manual for details. For continuity only. Refer to Installation Manual for details. Figure A-8 2 to 16 Loop Panel Rear of Door 9 Taktis Quick Start Guide 1 2 3 4 5 2 6 7 2 8 ID Description 1 Earth Link 2 Hinge Loop 3 Door Chassis 4 LCD Main Processor Board 5 Zone LED Board Comment For continuity only. Refer to Installation Manual for details. Refer to Installation Manual for details. Refer to Installation Manual for details. Refer to Installation Manual for details. Refer to Installation Manual for details. ID Description 6 Printer (Optional) 7 Door Chassis 8 Product Label/Logo Position 9 Panel Lock Comment Refer to Installation Manual for details. Refer to Installation Manual for details. - - Man-1172EN Rev. 04 Taktis Quick Start Guide 8 Taktis Quick Start Guide Hanging the Enclosure To hang the enclosure proceed with the following steps. For details on how to remove the enclose components please refer to the Installation Section of the FACP Installation Manual. 1. Start by marking the fixing centres for the upper two enclosure fixing points. Ensure your fixing centres are level. Figure A-9 Marking the enclosure fixing centres 487mm 368mm LEVEL LINE 2 to 8 Loop Enclosure External Dimensions: 420mm x 590mm 2 to 16 Loop Enclosure External Dimensions: 537mm x 716mm Note: Where permissible use the appropriate wall plugs for your fixings. Man-1172EN Rev. 04 Taktis Quick Start Guide 9 Taktis Quick Start Guide 2. Attach the two fixings to the wall using appropriate wall plugs. Screw fixings half-way home 3. Hang the enclosure on the two fixings, through the enclosure key-way fixing points. Figure A-10 Hanging the enclosure on the key-way fixing points 1 2 4. With the enclosure in place, mark for the two lower fixings and attach as appropriate. Depending on fixing/wall type, you may need to temporarily remove the enclosure when making the lower fixing holes. Figure A-11 Fixing the enclosure to the wall 5. With the enclose in place, tighten all four fixings using appropriate force. Man-1172EN Rev. 04 Taktis Quick Start Guide 10 Taktis Quick Start Guide Compliance Taktis FACP's are compliant with EN54-2, EN54-4 and are available with 2 to 8 loop or 2 to 16 loop, in four standard enclosure sizes. The modular construction allows control panels to be configured with a range of options including, zonal fire indicators, a printer, additional supervised ancillary inputs and outputs, networking Taktis FACP's together for larger system applications and remote communications. A large format, touch screen display is used to provide an exceptionally clear and intuitive user interface. This product should be installed, commissioned and maintained by trained service personnel in accordance with the following: (i) Regulations for electrical equipment in buildings specific to the country of use (ii) Codes of practice (iii) Statutory requirements (iv) Any instructions specifically advised by the manufacturer (v) Only fire rated and shielded cable should be used. Note: For LPCB approved installations use only FP200*, 1.5mm2 2 core cable. Environmental Considerations The PSU's are mounted in steel enclosures within the CIE with an ingress protection rating of IP30. The operating temperature range should not exceed -5°C to +40°C (±2°C). Humidity levels should not exceed 95% (non-condensing). Standards and Directives The control equipment is designed in compliance for: Table 1: Standards and Directives Low Voltage Directive 2014/35/EU EN62368 Audio/Video, Information and Communication Technology Equipment, Safety Requirements EN54-2 EMC Directive 2014/30/EU EN50130 Electromagnetic compatibility - product family standard EN54-4 EN54-13 Declaration Of Performance Taktis fire alarm control and indicating equipment and power supply equipment conform to the essential requirements of the Construction Products Regulation No.305/2011 Table 2: Certified with the following Options with requirements from EN 54-2:1997 7.8 Output to fire alarm device(s) 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10.3 Output to type C 7.10.4 Fault monitoring of fire protection equipment 7.11 Delay to outputs 7.12.1 Dependencies on more than one alarm signal Type A 7.12.2 Dependencies on more than one alarm signal Type B 7.12.3 Dependencies on more than one alarm signal Type C 7.13 Alarm counter 8.3 Fault signals from points 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition Man-1172EN Rev. 04 Taktis Quick Start Guide 11 Taktis Quick Start Guide EN54-4: 1997 +A1:2002 +A2:2006 (Power supply equipment for fire detection and fire alarm systems for buildings.) Table 3: EN54-4: 1997 +A1:2002 +A2:2006 (Functions Provided) Operation from a main power supply- EN54-4 clause 5.1 Monitor and charge the standby battery - EN54-4 clause 5.3 S408 10.25A Universal Input Power Supply has been approved with 230V AC mains input. Operation from a standby battery - EN54-4 clause 5.2 Recognise and notify supply faults - EN54-4 clause 5.4 S406 5.25A Power Supply has been approved both with 230V AC and 115V AC mains input. Table 4: Requirements subject to third party testing and approvals IFAM German Interface Functionality The products also comply with the following: Table 5: Low Voltage and Electromagnetic Compatibility Directives Low Voltage Directive 2014/35/EU EN62368 - Audio/Video, Information and Communication Technology Equipment Safety Requirements Electromagnetic Compatibility Directive 2014/30/EU BS EN55022: 1998 - Emissions, Spur. EN50130-4: 1995 +A1:1998 +A2:2003 EN50130-4: 2011 Alarm systems, Electromagnetic compatibility - Product family standard: Immunity requirements for components of fire, intruder, hold up, CCTV, access control and social alarm systems. EN6100-6-3:2007:+A1:2001 - Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for residential, commercial and light-industrial environments. Table 6: Additional functions provided that are not covered by EN54-2, EN54-4 or EN54-13 Auxiliary power outputs Programmable inputs Ethernet and GPRS remote connections Programmable relay outputs Programmable cause and effects Panel mounted printer Rating Label Kentec Electronics Ltd. Dartford DA1 1JQ U.K. 2831-CPR-F0912 360b/01 G 220007 EN 54-2:1997 + A1: 2006 EN 54-4:1997 + A1: 2002 + A2: 2006 TAKTIS - CONTROL AND INDICATING EQUIPMENT FOR FIRE DETECTION AND FIRE ALARM SYSTEMS FOR BUILDINGS PROVIDED OPTIONS: Output to fire alarm device(s) - EN54-2 clause 7.8 Output to fire alarm routing equipment - EN54-2 clause 7.9.1 Alarm confirmation input from fire alarm routing equipment - EN54-2 clause 7.9.2 Output to type C - EN54-2 clause 7.10.3 Fault monitoring of fire protection equipment - EN54-2 clause 7.10.4 Delay to outputs - EN54-2 clause 7.11 Dependencies on more than one alarm signal Type A - EN54-2 clause 7.12.1 Dependencies on more than one alarm signal Type B - EN54-2 clause 7.12.2 Dependencies on more than one alarm signal Type C - EN54-2 clause 7.12.3 Alarm counter - EN54-2 clause 7.13 Fault signals from points - EN54-2 clause 8.3 Output to fault warning routing equipment - EN54-2 clause 8.9 Disablement of addressable points - EN54-2 clause 9.5 Test condition - EN54-2 clause 10 For other technical data see O & M Manual Doc ref: Man-1154 Works Order No: Model number: Date of manufacture: Power rating 230 VAC, 1A, 50Hz Lab-1821 B4691 Mains fuse - 250V, 3A SB - Replace only with similar type. V1.2 Man-1172EN Rev. 04 Taktis Quick Start Guide 12 Taktis Quick Start Guide Safety Suppliers of articles for use at work are required under section 6 of the Health and Safety at Work act 1974 to ensure as reasonably as is practical that the article will be safe and without risk to health when properly used. An article is not regarded as properly used if it is used without regard to any relevant information or advice relating to its use made available by the supplier. This product should be installed, commissioned and maintained by trained service personnel in accordance with the following: (i) IEE regulations for electrical equipment in buildings (ii) Codes of practice (iii) Statutory requirements (iv) Any instructions specifically advised by the manufacturer According to the provisions of the Act you are therefore requested to take such steps as are necessary to ensure that you make any appropriate information about this product available to anyone concerned with its use This equipment is designed to operate from 230V 50Hz mains supplies and is of class 1 construction. As such it must be connected to a protective earthing conductor in the fixed wiring of the installation. A readily accessible double pole disconnect device with a disconnect air gap of at least 3mm and conforming to EN 60950, shall be incorporated in the fixed wiring. Failure to ensure that all conductive accessible parts of this equipment are adequately bonded to the protective earth will render the equipment unsafe. Terms and Conditions Details of Kentec Electronics Ltd. Terms and Conditions including Warranties and Returns & Repair Policies can be found on our website at the following locations: Terms, Conditions & Warranty Returns & Repairs https://kentec.co.uk/terms-and-conditions/ https://kentec.co.uk/returns-policy/ Address of Kentec Electronics Ltd. Units 25-26 Fawkes Avenue, Questor, Dartford, Kent. DA1 1JQ United Kingdom Registered in England:FACP No.1937570 Tel: +44 (0)1322 222121 http://www.kentec.co.uk Disclaimer In no event shall The Manufacturer be liable for any damages or injury of any nature or kind, no matter how caused, that arise from the use of the equipment referred to in this manual. Strict compliance with the safety procedures set out and referred to in this manual, and extreme care in the handling or use of the equipment, are essential to avoid or minimise the chance of personal injury or damage to the equipment. The information, figures, illustrations, tables, specifications, and schematics contained in this manual are believed to be correct and accurate as at the date of publication or revision. However, no representation or warranty with respect to such correctness or accuracy is given or implied and The Manufacturer will not, under any circumstances, be liable to any person or corporation for any loss or damages incurred in connection with the use of this manual. The information, figures, illustrations, tables, specifications, and schematics contained in this manual are subject to change without notice. Unauthorised modifications to the fire detection system or its installation are not permitted, as these may give rise to unacceptable health and safety hazards. By installing this equipment on a computer network, the owner accepts full and unequivocal responsibility for ensuring that it is protected against all cyber threats and illegal tampering during the lifetime of the equipment. Any software forming part of this equipment should be used only for the purposes for which The Company supplied it. The user shall undertake no changes, modifications, conversions, translations into another computer language, or copies (except for a necessary backup copy). In no event shall The Manufacturer be liable for any equipment malfunction or damages whatsoever, including (without limitation) incidental, direct, indirect, special, and consequential damages, damages for loss of business profits, business interruption, loss of business information, or other pecuniary loss, resulting from any violation of the above prohibitions. Man-1172EN Rev. 04 Taktis Quick Start Guide 13 This page is intentionally left blank. Taktis Quick Start Guide Man-1172EN Rev. 04 Taktis Quick Start Guide 14