GE Profile™ GEOSPRING™ Smart Hybrid Heat Pump Water Heater

Model: PF40S10FPY

40-gallon, 120V, FlexCapacity

Dimensions and Installation Information (Inches)

Local Installation Regulations: Installation must comply with instructions, local codes, utility codes, utility company requirements, and the latest edition of the National Electrical Code (NFPA 70).

Installation Information: Refer to installation instructions packed with the water heater for complete details.

Power Requirements: Verify power supply matches the rating plate on the water heater.

Location: Install in a clean, dry area near the point of greatest heated water demand. Long uninsulated hot water lines waste energy and water. The room must be at least 10' x 10' x 7' (700 cubic feet) or larger. If the room is smaller, a louvered door with 240 square inches (0.15m²) or greater of open-air-flow area is required. Ensure access for servicing, including filter removal and cleaning. Protect from freezing temperatures and corrosive atmospheres. Do not install outdoors.

Clearance Requirements:

Condensate Drain Required: A primary drain pipe must be installed at the top right side of the water heater to carry away condensate.

Diagram Description: An illustration shows the water heater with dimensions (24" width, 59 1/2" height) and indicates clearance requirements. Another diagram shows the top view with connections.

Water Supply Connections:

Diagram Description: A diagram illustrates a typical water supply connection setup, including unions, shut-off valves, thermal expansion tank, temperature & pressure relief valve, and condensate drain line. It also shows electrical conduit and a leak detect sensor.

Installation Checklist

  1. Tank Location: Verify room size requirements (ventilation/airflow), back and side clearances, and front access. Ensure the unit is level; use shims if necessary.
  2. Air Filters: Confirm air filters are installed on the product.
  3. Plumbing Connections: Check for leaks after filling the tank. Ensure filter removal is not obstructed. Install a shut-off valve and leak detect sensor.
  4. Condensate Lines: Verify the main drain line is installed and directed to a drain or pump. Avoid reducer fittings.
  5. Temperature & Pressure Relief Valve: Confirm the valve is working and the drain line is completed according to local code.
  6. Electrical: For 120V models, verify connection to a standard 120VAC outlet with a 10ft electrical cord. Units operate on a 15A shared circuit and convert to 120V on a 20A dedicated circuit. For 240V models, verify connection to 208/240 VAC.
  7. Electrical Connection: Ensure the electrical connection does not prevent air filter removal.
  8. Control Panel: Verify the control panel displays 120°F (49°C) Hybrid mode. Assist user with temperature and mode adjustments.
  9. SmartHQ™ App: Download the app and connect the appliance to WiFi/Bluetooth®.

Normal Startup - What to Expect After Pressing the Power Button

Elapsed Time Hybrid Electric Water Heater Actions Comments
0 to 3 minutes Unit performs self-check. Fan turns on after 1 minute. 3-minute off-time prevents compressor damage. A clicking noise may be heard.
3 to 12 minutes Compressor turns on. Fan continues to run. 9-minute period ensures the tank is full of water (dry-fire prevention). A F75 Fault code displays if no water is detected.
12 minutes and beyond Compressor turns off (fan runs for 30 minutes). Normal heating operation resumes. The water heater operates in Hybrid mode, using the heat pump and electric elements for efficient heating.

Note: The heat pump operating range is 35°F to 120°F (2°C to 49°C). If the ambient temperature is outside this range, the heat pump turns off, and electric elements are used until the ambient temperature returns to within the operating range.

Features and Benefits

Models: PF40S10FPY, GEOSPRING PF40S10FPY Smart Hybrid Heat Pump Water Heater, GEOSPRING PF40S10FPY, Smart Hybrid Heat Pump Water Heater, Hybrid Heat Pump Water Heater, Heat Pump Water Heater, Pump Water Heater, Water Heater, Heater

File Info : application/pdf, 4 Pages, 4.38MB

PDF preview unavailable. Download the PDF instead.

hi6wef9hksolm701vg8j

References

Adobe PDF Library 17.0 Adobe InDesign 20.3 (Macintosh)

Related Documents

Preview GE Profile GEOSPRING Smart Hybrid Heat Pump Water Heater PH40S10BPY - Specifications and Installation
Detailed specifications and installation information for the GE Profile GEOSPRING Smart Hybrid Heat Pump Water Heater, 40-gallon, 240V, FlexCapacity model PH40S10BPY. Includes dimensions, clearance requirements, plumbing and electrical connections, features, benefits, and operation modes.
Preview GE Profile GEOSPRING Smart Hybrid Heat Pump Water Heater PF50S10FPY User Manual
Installation, operation, and features of the GE Profile GEOSPRING Smart Hybrid Heat Pump Water Heater, 50-gallon, 120V, FlexCapacity model PF50S10FPY. Includes dimensions, power requirements, water supply connections, and energy efficiency benefits.
Preview GE GEOSPRING Smart Hybrid Heat Pump Water Heater PH50S10BPY - 50 Gallon, 240V
Detailed specifications and installation information for the GE GEOSPRING Smart Hybrid Heat Pump Water Heater, 50-gallon, 240V, FlexCapacity model PH50S10BPY. Covers dimensions, installation requirements, power, location, water supply connections, filter removal, condensate drain, startup process, features, benefits, and warranty.
Preview GE Profile GEOSPRING Smart Hybrid Heat Pump Water Heater PH50S10BNY - 50 Gallon, 240V
Detailed specifications and installation information for the GE Profile GEOSPRING Smart Hybrid Heat Pump Water Heater, model PH50S10BNY. This 50-gallon, 240V unit offers energy efficiency, smart control via the SmartHQ app, wireless leak detection, and multiple operation modes.
Preview GE Profile PFQ97HSPVDS UltraFast Combo Washer/Dryer: Specifications and Features
Comprehensive technical specifications, dimensions, installation guidelines, features, and warranty details for the GE Profile PFQ97HSPVDS 4.8 cu. ft. UltraFast Combo Washer/Dryer with Ventless Heat Pump Technology.
Preview GE Profile PFQ83HSLWWW Washer/Dryer: Dimensions, Installation, and Features
Detailed specifications and features for the GE Profile PFQ83HSLWWW UltraFast Combo Washer/Dryer, including dimensions, installation requirements, electrical ratings, and key benefits like Pet Hair Mode and Ventless Heat Pump technology.
Preview GE Profile PFQ97HSPVDS UltraFast Combo Washer/Dryer: Specifications and Features
Detailed specifications, dimensions, installation information, features, and accessories for the GE Profile PFQ97HSPVDS 4.8 cu. ft. Ventless Heat Pump Technology Washer/Dryer Combo.
Preview GE Profile RV Dual Fuel Water Heater: Features, Performance & Accessories
Explore the GE Profile RV Dual Fuel Water Heater, designed for maximum performance, ease of installation, and maintenance. Features include 120V + LP gas operation, durable design, secured controls, and available exterior doors and controls.