Minimum Efficiency: 13.4 SEER2
Refrigerant: R-454B
For the latest AHRI system matches, please visit www.marsdeliversratings.com or AHRIdirectory.org.
The model number indicates key specifications:
A - Air Conditioner, S - Residential Split, A - R-454B, 13 - Minimum SEER2 Rating, 36 - Capacity (BTUH x 1000), S - Single Stage, 1 - Power (1=208/230-1-60), A - Revision Level.
Model | A - Width (in.) | B - Depth (in.) | C - Height (in.) | Shipping Weight (Lbs.) |
---|---|---|---|---|
ASA1318S1 | 24-1/4 | 24-1/4 | 25-1/4 | 128 |
ASA1324S1 | 24-1/4 | 24-1/4 | 29-1/4 | 134 |
ASA1330S1 | 28-1/4 | 28-1/4 | 29-1/4 | 152 |
ASA1336S1 | 28-1/4 | 28-1/4 | 33-1/4 | 161 |
ASA1342S1 | 28-1/4 | 28-1/4 | 37-1/4 | 195 |
ASA1348S1 | 28-1/4 | 28-1/4 | 29-1/4 | 215 |
ASA1360S1 | 28-1/4 | 28-1/4 | 37-1/4 | 250 |
Note: Dimensions listed are unit sizes without packaging.
Size | Octave Band Sound Power Levels dBA, re 10-12 Watts Center Frequency - Hz | Sound Rating Number (dBA) | Estimated Sound Pressure Level at Distance From Unit (dBA at distance in ft.) | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
125 | 250 | 500 | 1000 | 2000 | 4000 | 8000 | 3 | 5 | 10 | 15 | 50 | ||
018 | 53 | 58.5 | 66.5 | 69.5 | 65 | 62.5 | 54.5 | 73 | 66 | 61 | 55 | 52 | 41 |
024 | 56 | 66 | 72 | 71 | 67 | 63 | 56.5 | 76 | 69 | 64 | 58 | 55 | 44 |
030 | 55 | 64.5 | 70.5 | 72.5 | 67.5 | 61 | 54 | 76 | 69 | 64 | 58 | 55 | 44 |
036 | 58 | 67.5 | 71.5 | 70.5 | 66.5 | 61.5 | 55 | 76 | 69 | 64 | 58 | 55 | 44 |
042 | 56 | 65 | 71 | 71.5 | 67.5 | 62 | 55 | 76 | 69 | 64 | 58 | 55 | 44 |
048 | 61.5 | 68 | 73.5 | 72.5 | 69 | 64 | 56.5 | 78 | 71 | 66 | 60 | 57 | 46 |
060 | 63.5 | 70 | 75 | 75 | 70.5 | 68 | 61 | 80 | 73 | 68 | 62 | 59 | 48 |
1 Tested according to AHRI Standard 270-2008 test conditions.
2 Estimated sound pressure level at distance based on AHRI Standard 275-2010 method for equipment located on the ground, roof, or on side of building wall with no adjacent reflective surface within 9.8 feet. Sound pressure levels will increase based on changes to assumptions. For other applications, refer to AHRI Standard 275.
Size | Nominal Tonnage | Sound Rating Number (dBA) | Connections (Sweat) | Liquid line (OD) - in. | Suction line (OD) - in. | Compressor Type | Refrigerant R-454B charge furnished | Indoor Unit Expansion Valve (TXV) | Outdoor Coil Net face area - ft.2 | Outdoor Coil Tube diameter - in. | Outdoor Coil Rows | Outdoor Coil Fins - in. | Outdoor Fan HP | Outdoor Fan Diameter - in. | Outdoor Fan Blades | Outdoor Fan Cfm | Outdoor Fan Rpm | Outdoor Fan Watts | Shipping Data - lbs. |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ASA1318S1 | 1.5 | 73 | 3/8 | 3/4 | 1-Stage Scroll | 4 lbs. 0 oz. | 26Z70 | 11.33 | 5/16 | 1 | 26 | 1/10 | 18 | 3 | 2290 | 1075 | 150 | 128 | |
ASA1324S1 | 2 | 76 | 3/8 | 3/4 | 1-Stage Scroll | 4 lbs. 7 oz. | 26Z70 | 13.22 | 5/16 | 1 | 26 | 1/10 | 18 | 3 | 2350 | 1075 | 155 | 134 | |
ASA1330S1 | 2.5 | 76 | 3/8 | 3/4 | 1-Stage Scroll | 4 lbs. 14 oz. | 26Z70 | 16.33 | 5/16 | 1 | 26 | 1/6 | 22 | 3 | 2610 | 825 | 160 | 152 | |
ASA1336S1 | 3 | 78 | 3/8 | 3/4 | 1-Stage Scroll | 5 lbs. 10 oz. | 26Z70 | 18.67 | 5/16 | 1 | 26 | 1/6 | 22 | 3 | 2800 | 825 | 190 | 161 | |
ASA1342S1 | 3.5 | 76 | 3/8 | 3/4 | 1-Stage Scroll | 6 lbs. 2 oz. | 26Z71 | 21.00 | 5/16 | 1 | 26 | 1/3 | 22 | 3 | 2985 | 825 | 150 | 195 | |
ASA1348S1 | 4 | 78 | 3/8 | 7/8 | 1-Stage Scroll | 7 lbs. 10 oz. | 26Z71 | 16.33 | 5/16 | 2 | 22 | 1/4 | 22 | 3 | 2875 | 825 | 160 | 215 | |
ASA1360S1 | 5 | 80 | 3/8 | 1-1/8 | 1-Stage Scroll | 8 lbs. 8 oz. | 26Z72 | 21.00 | 5/16 | 2 | 22 | 1/4 | 22 | 3 | 3250 | 845 | 280 | 250 |
ASA1318S1 | ASA1324S1 | ASA1330S1 | ASA1336S1 | ASA1342S1 | ASA1348S1 | ASA1360S1 | |
---|---|---|---|---|---|---|---|
Line voltage data (Volts-Phase-Hz) | 208/230-1-60 | 208/230-1-60 | 208/230-1-60 | 208/230-1-60 | 208/230-1-60 | 208/230-1-60 | 208/230-1-60 |
Maximum overcurrent protection (MOCP) amps | 15 | 20 | 25 | 30 | 35 | 40 | 50 |
Minimum circuit ampacity (MCA) | 11.1 | 13.5 | 16.6 | 17.8 | 21.2 | 24.3 | 31.3 |
Compressor Rated load amps | 8.3 | 10.2 | 12.5 | 13.4 | 14.9 | 18.0 | 23.7 |
Compressor Locked rotor amps | 45 | 60.2 | 67.8 | 82.5 | 109 | 126 | 157 |
Fan Motor full load amps | 0.65 | 0.65 | 1.0 | 1.0 | 2.6 | 1.7 | 1.7 |
Fan Motor Locked rotor amps | 1.3 | 1.3 | 1.9 | 1.9 | 3.2 | 3.2 | 3.2 |
Accessory | Model Number | ASA1318S1 | ASA1324S1 | ASA1330S1 | ASA1336S1 | ASA1342S1 | ASA1348S1 | ASA1360S1 |
---|---|---|---|---|---|---|---|---|
Compressor Hard Start Kit | Copeland 27V63 | • | • | • | • | • | Factory Installed | Factory Installed |
Crankcase Heater | LG 27U16 | • | • | • | • | • | Factory Installed | Factory Installed |
Compressor Hard Start Kit | Copeland 63W22 | • | • | |||||
10J42 | • | • | • | • | • | |||
LG 10J42 | • | • | • | • | • | |||
Compressor Low Ambient Cut-Off Switch | 45F08 | • | • | • | • | • | • | • |
Compressor Timed-Off Control | 47J27 | • | • | • | • | • | • | • |
Compressor Sound Cover | 18J42 | • | • | • | • | • | • | • |
Freezestat | 93G35 | • | • | • | • | • | • | • |
Indoor Blower Off Delay Relay | 58M81 | • | • | • | • | • | • | • |
Loss of Charge Switch Kit | 84M23 | • | • | • | • | • | • | • |
Low Ambient Kit (Fan Cycling) | 34M72 | • | • | • | • | • | • | • |
NOTE - Extremes of operating range are plus 10% and minus 5% of line voltage.
1 Refrigerant charge is sufficient for 15 ft. length of refrigerant lines. For longer line set requirements see the Installation Instructions for information about line set length and additional refrigerant charge required.
2 HACR type breaker or fuse.
3 Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements.
4 Crankcase Heater and Freezestat are recommended with Low Ambient Kit.
The field wiring diagram illustrates connections between the Air Conditioner, Thermostat (optional), and Heating Unit or Air Handler Unit. It specifies wiring types: A - Two Wire Power (not furnished), B - Two Wire Power (not furnished), C - Four Wire Low Voltage (not furnished, 18 ga. minimum), D - Five Wire Low Voltage (not furnished, 18 ga. minimum). All wiring must conform to NEC or CEC and local electrical codes.
Proper clearances are essential for optimal performance and serviceability. Specific requirements include:
This guide provides a general reference for replacing the factory-installed R-454B TXV if the indoor unit (coil/air handler) is larger or smaller than the outdoor unit.
Outdoor Unit Size | Tons | Indoor Unit Size | Tons | TXV Furnished | TXV Replacement |
---|---|---|---|---|---|
018 | 1.5 | 42 | 3.5 | 26Z70 | 26Z71 |
018 | 1.5 | 48 | 4 | 26Z70 | 26Z71 |
018 | 1.5 | 49 | 4 | 26Z70 | 26Z71 |
018 | 1.5 | 50/60 | 4/5 | 26Z70 | 26Z72 |
018 | 1.5 | 51/61 | 4/5 | 26Z70 | 26Z72 |
018 | 1.5 | 60 | 5 | 26Z70 | 26Z72 |
024 | 2 | 42 | 3.5 | 26Z70 | 26Z71 |
024 | 2 | 48 | 4 | 26Z70 | 26Z71 |
024 | 2 | 49 | 4 | 26Z70 | 26Z71 |
024 | 2 | 50/60 | 5 | 26Z70 | 26Z72 |
024 | 2 | 51/61 | 5 | 26Z70 | 26Z72 |
024 | 2 | 60 | 5 | 26Z70 | 26Z72 |
030 | 2.5 | 42 | 3.5 | 26Z70 | 26Z71 |
030 | 2.5 | 48 | 4 | 26Z70 | 26Z71 |
030 | 2.5 | 49 | 4 | 26Z70 | 26Z71 |
030 | 2.5 | 50/60 | 4/5 | 26Z70 | 26Z72 |
030 | 2 | 51/61 | 4/5 | 26Z70 | 26Z72 |
030 | 2.5 | 60 | 5 | 26Z70 | 26Z72 |
036 | 3 | 42 | 3.5 | 26Z70 | 26Z71 |
036 | 3 | 48 | 4 | 26Z70 | 26Z71 |
036 | 3 | 49 | 4 | 26Z70 | 26Z71 |
036 | 3 | 50/60 | 5 | 26Z70 | 26Z72 |
036 | 3 | 51/61 | 5 | 26Z70 | 26Z72 |
036 | 3 | 60 | 5 | 26Z70 | 26Z72 |
042 | 3.5 | 24 | 2 | 26Z71 | 26Z70 |
042 | 3.5 | 30 | 2.5 | 26Z71 | 26Z70 |
042 | 3.5 | 30/36 | 3 | 26Z71 | 26Z70 |
042 | 3.5 | 36 | 3 | 26Z71 | 26Z70 |
048 | 4 | 30/36 | 2.5/3 | 26Z71 | 26Z70 |
048 | 4 | 36 | 3 | 26Z71 | 26Z70 |
TXV Ranges:
![]() |
Comfort-Aire ASA14**S1 LE Series Split Air Conditioner System Specifications and Features Detailed information on the Comfort-Aire ASA14**S1 LE Series split air conditioner system, including features, specifications, applications, approvals, and technical data. |
![]() |
Comfort-Aire RSG16 Series 16 SEER Split Air Conditioner System Specifications Detailed specifications, performance data, dimensions, and accessories for the Comfort-Aire RSG16 series 16 SEER split air conditioner systems, including models RSG1624S1M, RSG1636S1M, RSG1648S1M, and RSG1660S1M. Features include Copeland compressors, R410a refrigerant, and robust cabinet design. |
![]() |
Comfort-Aire Century SAC1318S1A Split System Air Conditioner Parts List Detailed parts list for the Comfort-Aire Century SE Series SAC1318S1A Split System Air Conditioner, including part codes, names, quantities, and recommendations for storing spare parts. |
![]() |
Comfort-Aire Century SAC1418S1A Split System Air Conditioner Parts List Detailed parts list and diagram for the Comfort-Aire Century SE Series SAC1418S1A Split System Air Conditioner, including part codes, names, quantities, and visual component descriptions. |
![]() |
Comfort-Aire RSA14**S1A SE Series Split System Air Conditioner Specifications Detailed specifications, features, and dimensions for the Comfort-Aire RSA14**S1A SE Series split system air conditioners, covering models from 18,000 to 60,000 BTU/h. |
![]() |
Comfort-Aire CMA14**SG Series Horizontal Discharge Condensers | Specifications & Features Explore the Comfort-Aire CMA14**SG Series horizontal discharge condensers, offering 14 SEER efficiency, compact design, and quiet operation for residential and light commercial applications. View detailed specifications, capacities, and dimensions. |
![]() |
Comfort-Aire Century SAC1330S1A Split System Air Conditioner Parts List Detailed parts list for the Comfort-Aire Century SAC1330S1A Split System Air Conditioner, including part codes, names, and quantities. Includes information on product specifications, installer responsibilities, and contact details for Mars. |
![]() |
Comfort-Aire Heating and Cooling Products Catalog Comprehensive catalog of Comfort-Aire heating and cooling products, including residential and commercial HVAC systems, air handlers, coils, furnaces, heat pumps, and room air conditioners. |